• Title/Summary/Keyword: roof materials

Search Result 285, Processing Time 0.03 seconds

The Planning of Micro-climate Control by Complex Types (단지 유형에 따른 도시의 미기후 조절 계획에 관한 연구)

  • Jeong, Juri;Chung, Min Hee
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • Purpose: Temperature in urban areas increase much more than suburban areas and it is called urban heat island (UHI) phenomenon. There are several solutions to control UHI phenomenon such as green roof system, water space construction, and cool roof system. However, application of green roof system and cool roof system to some of the buildings which compose the city has a critical limit. Therefore, in order to diminish the temperature rising and UHI phenomenon due to climate change of the city, it needs to approach from the viewpoint of site or city, rather than the viewpoint of individual buildings. This study is aims at analyzing UHI phenomenon by characteristics of surface materials and suggesting the solutions to reduce UHI phenomenon by types of complex. Method: Literature reviews were conducted to analyze the cause, mitigating plan, and recent trends of UHI phenomenon. For the simulation analysis, the type of complex was classified 3 representative complex. Based on measured reflectivity, simulation about UHI phenomenon was conducted by setting 4 strategies; albedo of roof, road pavement, green roof system, and vegetating around buildings. Result: As the results of simulating the UHI reduction factor by types of complex, it showed that the effect of temperature reduction on the building roof layer is more effective than adjusting the reflectivity of buildings such as green roof system, planting near the buildings in both the detached house complex, apartment complex, and commercial complex.

The Roof Construction Method of Urban Hanok in Bukchon, Seoul (북촌도시한옥의 지붕가구(架構) 특징에 관한 연구)

  • Song, In-He;Kim, Young-Soo
    • Journal of architectural history
    • /
    • v.14 no.4 s.44
    • /
    • pp.87-100
    • /
    • 2005
  • We have focused on the roof construction method of Urban Hanok in Bukchon, Seoul. The Urban Hanok, urban traditional housing type, had been evolved In modern context from 1930's to 1960's. We have confused Urban Hanok with traditional Hanok, because they have similar figures. But Urban Hanok have the characteristics as a result of the roof construction method. The purpose of this paper is to define Urban Hanok more concretely, thus we payed attention to the roof structure, specially to the comer that each roof structure meets. So we got some characteristics of the roof construction method of Urban Hanok in Bukchon. First, the roof construction methods of the roof are transformed at the corner parts, where three purlin structure and five purlin structure meet. The collision of the different roof structure has made a lot of types. Second, the roof slope of Urban Hanok is more gentle than traditional Hanok, that is caused by ornamental double eaves and awnings. Finally these characteristics are results of the compact lot size in urban neighborhood. The construction method is a inclusive word that contain materials, composition, ornament and social common sense. With the understanding on the roof construction method of Urban Hanok, we can define the identity and the value of Urban Hanok, And we can suggest the policy and the design guidelines for the reservation and rehabilitation for Urban Hanok of Bukchon, Seoul.

  • PDF

A Studyof Materials and Structural Designs in the Glulam Architecture -Focusing in the Roof Structure- (집성재건축의 자재특성과 구조디자인 연구 -지붕구조를 중심으로-)

  • 김란기
    • Korean Institute of Interior Design Journal
    • /
    • no.13
    • /
    • pp.203-215
    • /
    • 1997
  • This Study typed the roof-design in analysis of structural design of the glulam architecture, developed worldwidely, nowaday. For this, it is studied the characters of glulam as the history of glulam architectures, manufacture of glulam, shapes and section of glulam, fireproof and combution of glulam. And it is studied roof-design according to structural type of glulam roof-structure. Conclusively, types of glulam roof design typied as 1)the Simple Beam str., 2)the Multi-Joints continous Beam str. 3)the Hinge str. 4)the Rahmen str. 5)the Archi str. 6)the Grid str. 7)etc str. (Folded-plate str., Radial str., Cylinder Shell str., Ring Dome str., Geodesic Dome str., Conic Coloid Shell str., H.P Shell str. Cantilever Shell str.)

  • PDF

Experimental and Numerical Assessment of the Service Behaviour of an Innovative Long-Span Precast Roof Element

  • Lago, Bruno Dal
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.261-273
    • /
    • 2017
  • The control of the deformative behaviour of pre-stressed concrete roof elements for a satisfactory service performance is a main issue of their structural design. Slender light-weight wing-shaped roof elements, typical of the European heritage, are particularly sensitive to this problem. The paper presents the results of deformation measurements during storage and of both torsional-flexural and purely flexural load tests carried out on a full-scale 40.5 m long innovative wing-shaped roof element. An element-based simplified integral procedure that de-couples the evolution of the deflection profile with the progressive shortening of the beam is adopted to catch the experimental visco-elastic behaviour of the element and the predictions are compared with normative close-form solutions. A linear 3D fem model is developed to investigate the torsional-flexural behaviour of the member. A mechanical non-linear beam model is used to predict the purely flexural behaviour of the roof member in the pre- and post-cracking phases and to validate the loss prediction of the adopted procedure. Both experimental and numerical results highlight that the adopted analysis method is viable and sound for an accurate simulation of the service behaviour of precast roof elements.

An Experimental Study on Placements and Thickness of Damping Material for Vibration Control of Automotive Roof (자동차 루프의 진동제어를 위한 제진재의 위치 및 두께에 대한 실험적 연구)

  • Lee, Jeong-Kyun;Kim, Chan-Mook;Sa, Jong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.31-37
    • /
    • 2005
  • This paper presents an experimental study on vibration characteristics of an automotive roof with damping material. The goal of the study is to extract modal parameters(natural frequency, loss factor, and mode shape) of automotive roof with damping materials treatment. To determine the effective positions and thickness of the damping material on a roof, vibration tests have been carried out for six cases; an aluminum plate with damping material on maximum strain energy positions, and an aluminum plate with damping material on nodal lines. From the result of aluminum plate, it is found that the damping material should be placed on the location with maximum strain energy part. For the automotive roof, patches of constrained damping material, which has two different density, have been attached to the positions of the maximum strain energy with four kinds of thicknesses. This paper shows that the proper positioning of the damping material is very important and the effective thickness is about twice that of the roof panel.

A Study of Cooling and Heating Load Changes with Roof Type Solar Panels Installed on Factory Roof (지붕형 태양광발전 패널의 공장 지붕 설치에 따른 냉방 및 난방 부하 변화량 연구)

  • Jo, Ho-Hyeon;Kim, Jung-Min;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.9-15
    • /
    • 2020
  • In this study, effect of reinforced insulation on heating and cooling loads were studied due to installation of PV panels on factory building roof with a floor area of 12,960 m2. For PV panel installation, combination of aluminum, polyurethane, air, polystyrene and steel materials were added to the original roof, which increased thermal insulation performance. Half of the roof were covered with PV panel and the other half without. Temperature and relative humidity were measured for 8 days during summer season for both indoor spaces. PV panel showed the effect of lowering the indoor space temperature by 0.6℃. TRNSYS dynamic simulation showed that with PV panel, cooling load per area is reduced by 1.7 W/m2 and heating by 10.0 W/m2. PV panels installed on building roof not only generate electricity but also can save energy by reducing cooling and heating loads.

An Analysis of Energy Reduction Effects in Housing According to Green Roof (옥상녹화에 따른 공동주택 에너지 저감효과 분석 연구)

  • Kim, Ji-Hyeon;Son, Hyeong-Min;Kwon, Hyuck-Sam;Kim, Jong-Gon;Lee, Bum-Sik
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.299-305
    • /
    • 2016
  • This study aims to provide basic materials for expanding application of green roof afforestation by analyzing structures' energy consumption reduction effects according to green roof afforestation as a planning means to cope with climate change. As the subjects, recently completed apartment buildings and service facilities of apartment houses where green roof afforestation was applied were selected. green roof afforestation of Extensive Green Roof(soil depth: 20cm) and Semi-Intensive Green Roof(soil depth: 40cm) in construction types was applied and design builders were utilized in order to compare energy reduction amount according to the application of green roof afforestation. According to the analysis result, all the buildings had energy reduction effect when green roof afforestation was applied.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

A Study on the Characteristics by Design Component Elements of the Facade in Elementary School Buildings in the 2000's (2000 년대 초등학교 교사 입면의 디자인 구성요소에 의한 특성 연구)

  • Seo, Hee-Sook
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.38-47
    • /
    • 2010
  • The purpose of this study is to examine the characteristics by design component elements of the facade in elementary school buildings after the 7th educational curriculum. This study choose twenty five elementary school as the subjects of the study. And among many elevations of building, an elevation that is alongside of the schoolyard is chosen because this elevation has the highest visual influence on passers-by. To begin with, this elevation is divided into the roof and the surface of a wall, The roof is divided into roof styles, existence of roof and materials. The surface of a wall is divided into design principles(balance, contrast, rhythm), the formal organization(basic elements and form, and transformation of form), the ornamental composition, materials and colors. The results of the research are summarized as follows: First of all, motifs of classical architecture were well expressed in this period and postmodern tendency had been shown until 2005. After Build Transfer Lease(BTL), however, tendency of classical architecture, contrast by the size of the form and base element by point disappeared. Instead, asymmetrical and flat tendency is expressed. Also, emphasized design of the building elevation appear by basic colors of Munsell, not motifs of classical architecture.

Life cycle assessment (LCA) of roof-waterproofing systems for reinforced concrete building

  • Ji, Sukwon;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • v.3 no.4
    • /
    • pp.367-377
    • /
    • 2014
  • In this study, we investigated a life cycle assessment (LCA) of six roof-waterproofing systems [asphalt (C1), synthetic polymer-based sheet (C2), improved asphalt (C3), liquid applied membrane (C4), Metal sheet with asphalt sheet (N1), and liquid applied membrane with asphalt sheet (N2)]for reinforced concrete building using an architectural model. To acquire accurate and realistic LCA results, minimum units of material compositions for life cycle inventory and real data for compositions of waterproofing materials were used. Considering only materials and energy demands for waterproofing systems per square meter, higher greenhouse gas (GHG) emissions could be generated in the order of C1 > N2 > C4 > N1 > C2 > C3 during construction phase. However, the order was changed to C1 > C4 > C3 > N2 > N1 > C2, when the actual architecture model was applied to the roof based on each specifications. When an entire life cycle including construction, maintenance, and deconstruction were considered, the amount of GHG emission was in the order of C4 > C1 > C3 > N2 > C2 > N1. Consequently, N1 was the most environmental-friendly waterproofing system producing the lowest GHG emission. GHG emissions from maintenance phase accounted for 71.4%~78.3% among whole life cycle.