• 제목/요약/키워드: roof and floor

검색결과 213건 처리시간 0.023초

Evaluation on Low-floor Bus Package Layout from the Perspective of Universal Design

  • Kim, Sun-Woong;Kim, Ji-Yeon;HwangBo, Hwan;Hwang, Bong-Ha;Moon, Yong-Joo;Ji, Young-Gu
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.659-669
    • /
    • 2011
  • Objective: The aim of this study is to suggest a package layout guideline for low-floor bus by interview with passengers and observations of their behavior. Background: Increasing attention has been introduced the low-floor bus to be more suitable for use by transportation handicapped. Complex issues are involved in providing comfortable services to all people. We are going to suggest package layout guidelines for more comfortable and suitable travel to all people. Method: The two times of survey and video observation sessions were conducted on low-floor buses in Seoul; (1) a finding of potential issues in the first session, (2) a confirming of issues from the last session. Results: The three of major issues were founded in this study; (1) difficulties in supporting body when standing, (2) difficulties in sitting on front wheel pan seat, (3) difficulties in passing through the aisle. Conclusion: There were clear differences between public and transportation handicapped in using some tools which are used for support body such as roof hand rails, side hand rails, and hand rail rings. Some of design problems were founded to improve from the perspective of ergonomics and universal design. Such differences and design guidelines have to be considered in bus design as well as commercial vehicle. Application: The proposed design guidelines can be used to development of low-floor bus and other public transportations.

공동주택 최대난방부하 계산법의 분석 (An analysis of the Design heating load calculation in multi-family houses)

  • 조동우
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.26-32
    • /
    • 2000
  • Design load calculations which depend on the thermal characteristics of the building structure such as the wall, roof, and fenestration provide the basic data for selecting an HVAC system and its equipment. Most of domestic multi-family houses include a high thermal storage layer like massive concrete structure and a floor heating structure. This study is to compare the results of the design heating load between steady state and unsteady state calculation in order to comprehend the thermal storage effect in multi-family houses. The design heating load under the steady state calculation is estimated from 5.4% to 7.8% larger than that under the unsteady state in the typical floor of a multi-family house model. The design heating load considered the safety factors like a orientation and location factor also is 21.4% to 26.5% larger than that by the unsteady state calculation. So, the safety factors for use of the practicing engineer are analyzed as the main factor of a heating plant oversizing.

  • PDF

Establishment of Service Life of Educational Facilities - Focused on the rooftop waterproofing and floor finishing -

  • Lee, KangHee;Chae, ChangU
    • KIEAE Journal
    • /
    • 제14권5호
    • /
    • pp.5-12
    • /
    • 2014
  • Building has been deteriorated gradually owing to geographic, physical complex and other factors. School living condition has a key role to improve the learning ability, life attitude and qualifications to adopt to social life. Therefore, it is important for school environment to keep the living condition. Repair time and scope of school facilities are required to maintain the function and performance to plan the long term repair. But there are little information about the school maintenance such as repair time and function. In this paper, it aimed at providing the service life to suggest the repair time and scope in the roof-proofing and floor finishing which used the three estimation method in probabilistic approach. The service life has a key role to decide the repair time and to make the plan for the repair maintenance. Results of this study are as follows ; First, the 1st repair time were taken through three methods in probabilistic and deterministic functions to eliminate the estimation bias. Second, the service life is suggested 36 years of an elementary school, 34 years of a middle school and 41 years of a high school. Third, the service life of a floor finishing is 43 years of an elementary, 39 years of a middle school and 41 years of a high school. The above study could not include the detailed information about the materials and repair works. Therefore it needs a further study to reflect the detailed information and to make a repair strategy.

Research on reinforcement mechanism of soft coal pillar anchor cable

  • Li, Ang;Ji, Bingnan;Zhou, Haifeng;Wang, Feng;Liu, Yingjie;Mu, Pengfei;Yang, Jian;Xu, Ganggang;Zhao, Chunhu
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.697-706
    • /
    • 2022
  • In order to explore the stable anchoring conditions of coal side under the mining disturbance of soft section coal pillar in Wangcun Coal Mine of Chenghe Mining Area, the distribution model of the anchoring support pressure at the coal pillar side was established, using the strain-softening characteristics of the coal to study the distribution law of anchoring coal side support pressure. The analytical solution for the reinforcement anchorage stress in the coal pillar side was derived with the inelastic state mechanical model. The results show that the deformation angle of the roadway side and roof increases with the roof subsidence due to the mining influence at the adjacent working face, the plastic deformation zone extends to the depth of the coal side, and the increase of anchorage stress can effectively control the roof subsidence and further deterioration of plastic zone. The roadway height and the peak support pressure have a certain influence on the anchorage stress, the required anchorage stress of the coal side rises with the roadway height and the peak support pressure. The required anchorage stress of the coal pillar side decreases as the cohesion between the coal seam and the roof and floor and the anchor length increases. Then, applied the research result to Wangcun coal mine in Chenghe mining area, the design of anchor cable reinforcement support was proposed for the section of coal pillars side that has been anchored and deformed, which achieved great results and effectively controlled the convergence and deformation of the side, providing a safety guarantee for the roadway excavation and mining.

중층형 생활한옥 모델시안 연구 - 청주 서운동의 사례를 중심으로 - (The Tentative Plans of Middle-rise Traditional Houses (Han-ok) Located on Seoun-dong in Urban Area of Cheongju, Korea)

  • 김찬구;김태영
    • 한국농촌건축학회논문집
    • /
    • 제24권2호
    • /
    • pp.21-28
    • /
    • 2022
  • Focusing on the creation of a new han ok, especially a mid-rise hybrid-structured Han-ok, this study proposes a middle-rise (four-story) Han-ok on one and two lots located in Seoun-dong, the existing Han-ok intensive housing site in downtown Cheongju. 1) In terms of layout and function, according to the existing L-shaped Han-ok corresponding to the road and the direction, the parking lots and shops on the 1st floor, the business facility on the 2nd floor, the Han-ok on the 3rd and 4th floors are placed. There are yards, open roof yards, and semi-open Daecheong(大廳, main hall), which can be shared by residents. 2) In terms of structure and form, one or two floors (some 3 floors) are 5.4m square and 5.4×6.6m modules of the RC(Reinforced Concrete) group, and the upper floor reflects the 2.7m module, size and shape of the existing Han-ok. By extending the outer wall of the RC group in the lower floors (1st to 3rd floors) to the wooden exterior of the upper floors (2nd to 4th floors), it is attempted to avoid the awkward appearance of the RC group being exposed to wooden structures. And it is also attempted to reflect the wooden shape and design elements through the elevation elements such as horizontal windows, corner windows, picture frames, and vertical slits. 3) In environmental control and facilities, it is attempted to smooth the ventilation of the building by forming a vertical upward airflow from the dark space of the low floor to the positive of the upper floor. This doubles the effect through a vertical rise of cold air generated in a narrow alleyway, piloti parking lot, and the various voids. In addition to the Daecheong and Numaru(loft) of Han ok, the rooftop yard, the terrace, and the balcony, horizontal natural ventilation is generated through divided doors and transom windows.

New approaches to testing and evaluating the impact capability of coal seam with hard roof and/or floor in coal mines

  • Tan, Y.L.;Liu, X.S.;Shen, B.;Ning, J.G.;Gu, Q.H.
    • Geomechanics and Engineering
    • /
    • 제14권4호
    • /
    • pp.367-376
    • /
    • 2018
  • Samples composed of coal and rock show different mechanical properties of the pure coal or rock mass. For the same coal seam with different surrounding rocks, the frequency and intensity of rock burst can be significantly different in. First, a method of measuring the strain variation of coal in the coal-rock combined sample was proposed. Second, laboratory tests have been conducted to investigate the influences of rock lithologies, combined forms and coal-rock height ratios on the deformation and failure characteristics of the coal section using this method. Third, a new bursting liability index named combined coal-rock impact energy speed index (CRIES) was proposed. This index considers not only the time effect of energy, but also the influence of surrounding rocks. At last, a new approach considering the influences of roof and/or floor was proposed to evaluate the impact capability of coal seam. Results show that the strength and elastic modulus of coal section increase significantly with the coal-rock height ratio decreasing. In addition, the values of bursting liability indexes of the same coal seam vary greatly when using the new approach. This study not only provides a new approach to measuring the strain of the coal section in coal-rock combined sample, but also improves the evaluation system for evaluating the impact capability of coal.

Ground response of a gob-side gateroad suffering mining-induced stress in an extra thick coal seam

  • He, Fulian;Gao, Sheng;Zhang, Guangchao;Jiang, Bangyou
    • Geomechanics and Engineering
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2020
  • This paper presents an investigation of the ground response of a gob-side gateroad suffering mining stress induced by a 21 m-thick coal seam extraction. A field observation, including entry convergence and stress changes monitoring, was first conducted in the tailgate 8209. The observation results of entry convergence showed that, during the adjacent panel 8210 retreating period, the deformation of the gob-side gateroad experienced a continuous increase stage, subsequently, an accelerating increase stage, and finally, a slow increase stage. However, strong ground response, including roof bending deflection, rib extrusion and floor heave, occurred during the current panel 8209 retreating period, and the maximum floor heave reached 1530 mm. The stress changes within coal mass of the two ribs demonstrated that the gateroad was always located in the stress concentrated area, which responsible for the strong response of the tailgate 8209. Subsequently, a hydraulic fracture technique was proposed to pre-fracture the two hard roofs above the tailgate 8209, thus decreasing the induced disturbance on the tailgate. The validity of the above roof treatment was verified via field application. The finding of this study could be a reference for understanding the stability control of the gob-side gateroad in extra thick coal seams mining.

인태아(人胎兒) 척추(脊椎) 중심관(中心管) 상의층(上衣層)의 발육(發育)에 관한 전자현미경적(電子顯微鏡的) 연구(硏究) (Ultrastructural Study on the Development of the Ependyma of the Central Canal in Human Fetal Spinal Cord)

  • 윤재룡;최영주;오창석
    • Applied Microscopy
    • /
    • 제23권1호
    • /
    • pp.109-124
    • /
    • 1993
  • The prenatal development of thoracic spinal cord was studied by electron microscope in human embryos and fetuses ranging from 9mm to 260mm crown-rump length (5-30 weeks of gestational age). Ependymal cells in all fetal ages had conspicuous junctional complexes close to the lumen of the central canal into which microvilli and cilia projected. The ependymal cells contained numerous longitudinally arranged mitochondria, flattened cisternae of endoplasmic reticulum and Golgi complex. At 20 mm embryo, the floor and roof plates were composed of ependymoglial cells and undifferentiated neuroepithelial cells. The neuroepithelia of the sacral spinal cord were delineated from central medullary cord. By 100 mm fetus few undifferentiated neuroepithelial cells remained in the floor and roof plates. At 150 mm fetus, the whole central canal was formed by ciliated columnar epithelial cells containing cilia with basal bodies. The microvilli became tangled and club-shaped and formed a matted surface. The canal was filled with areas of dark and pale amorphous materials bounded by membrane-like structure. These two types of material were found throughout the whole central canal from 100 mm fetus onwards. By 260 mm fetus, microfibrils were first observed in the ependymal cells. In conclusion, it seems that early development and differentiation of central canal ependyma are simlar to that in other part of the brain ventricular system although ependymoglial cells are more prominent.

  • PDF

석조유구(石造遺構)를 통한 한국(韓國) 고대건축(古代建築)에 관한 연구(硏究) -삼국시대와 통일신라시대를 중심으로- (A Study on the Ancient Architecture in view of the Stone Remains (focused on the 3 Kingdom Period and Unificated Shilla Period))

  • 천득염;박지민
    • 건축역사연구
    • /
    • 제8권3호
    • /
    • pp.23-38
    • /
    • 1999
  • The purpose of this study is to analogize the appearance of Korean Ancient Architecture in view of the Stone Remains from 3 Kingdom Period to Unificated Shilla Period. But in these period, there is no building remains but some stupas and fine arts. Especially, there are many architectural appearance and revealing signature in these Historical Stone remains. Architectural elements which are analogized by stone remains what has value as historical materials by preservation of original form from 3 Kingdom Preiod to Unificated Shilla Period are as follows : 1) Platform, the representative characteristic of Korean traditional architecture, was frame structure and accumulate structure. And circular or square footing stood a same shape column on it is put on the platform. 2) In the case of column, there used entasis column and inclined column and circular chamfer technique was applied on the top side of it. Upper side of column, capital and head pentrating tie that small bearing block was put on the center of it was joined. And longitu야nal rest(長舌) supported a cross beam. Capital and small bearing block had no bottom heel, and heel side was curved and straight. Centered bracket structure was often used, and multi bracket structure is not used yet. Inward incline technique was used. 3) Inward opening pair door which had lintel, threshold, doorjamb was usually used, Fixing stone was used for structural safety, and circular handle and lock was used for decoration. Handrail was used on the edge of wooden floor for decorative effect and safety. 4) Square rafter and circular rafter were used in the same period and so did flying rafter. Double eaves and single eave were used in the same period but, single eave was usually used. In this period, square rafter was usually used. This would be studied more by comparing with Japanese wooden architecture. 5) Hipped roof was used and half-hipped roof was not used yet. In front of th hip, there are small sculpture called Jap-Sang(雜像), and windbell was hang on the end of the hip rafter. Concave roof tile, convex roof tile, round eaver tile, decorative tile at end of roof ridge were used. Lotus style was well used on the face of roof tile for decoration. From the results of this study, wooden architecture of Unificated Shilla period was simple compare to Koryo dynasty and Chosun dynasty but, it had some brilliant character. It was hard work that analogized the form of non-existent wood architecture of Ancient Korean period by restricted stone remains. But, in addition to the results of this study and research of old documentations, more study should be go on.

  • PDF

바로셀로나 파빌리온의 구축적 공간 특성에 관한 연구 (A Study on the Spatial Characteristics in the Tectonic of the Barcelona Pavilion)

  • 양재혁
    • 한국실내디자인학회논문집
    • /
    • 제33호
    • /
    • pp.19-26
    • /
    • 2002
  • This study analyzed the characteristics of spatial expression in the Barcelona Pavilion to be based on tectonics. Mies pointed out the image of materiality about the material rather than the process of tectonics using the material, and he also expressed demateriality in the image of each material through the reflection. To be liberated from structural matters, the wall has been introduced. He intended to show the design plan as the independent structural system, however, the wall actually seems to be supporting the roof that shows rather clearly self-contradictory because of the expression of materiality in the material. In terms of architectural elements; wall, roof, column, floor, and so forth, tectonic expression and abstract aesthetics stands face to face, because of hiding the productional process and transforming to line and surface in the image of materiality. The interior of the glass wall seems fairly closed space from the exterior, because materiality and reflection of materials of columns and podium. The character of experiential space is inconsistent and fragmentary because of the splendid images from maternality and reflection on the wall, and collision with the reality and the image the wall reflects, even though the geometrical space of the Pavilion's plan has the mutual penetrability and organic character.