• Title/Summary/Keyword: rolled beam(H-beam)

Search Result 24, Processing Time 0.03 seconds

Behavior of Main Girder in Continuous Girder System using Cross Girder Method (가로거더공법에서 주형의 연속화 시점에 따른 주형의 거동)

  • Park, Jeong-Ung;Seo, Won-Ju;Lee, Son-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.533-536
    • /
    • 2008
  • It is on increasing trend to employ H-rolled beams as main flexural members of bridges and of temporary structures owing to their handiness for construction, maintenance, and management. But in the case of applying H-rolled beams to bridges, maximum length of bridge span is around 20m. Therefore, to develop simplified steel-concrete composite bridge having long span using H-rolled beam needs new cross girder system at internal supports, optimization of bridge system without cross beams between supports and steel-concrete composite bridge deck. This study performs mechanical analysis of cross girder system for H-rolled beam steel-concrete composite bridge with long span and verifies its usefulness.

  • PDF

Effect of Cross Beams on Live Load Distribution in Rolled H-beam Bridges (압연형강(H형강) 거더교의 가로보가 활하중 횡분배에 미치는 영향)

  • Yoon, Dong Yong;Eun, Sung Woon
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.535-542
    • /
    • 2006
  • In this study, the effects of cross beams on the lateral distribution of live loads in composite rolled H-beam girder bridges, were investigated through three-dimensional finite element analysis. The parameters considered in this study were the inertial moment ratio between the main girder and the cross beam, the presence of the cross beam, and the number of cross beams. The live load lateral distribution factors were investigated through finite element analysis and the customary grid method. The results show that there was no difference between the bridge models with and without a cross beam. The cross beam of the beam and frame types also showed almost the same live load lateral distribution factors. However, the finite element analysis showed that the concrete slab deck plays a major role in the lateral distribution of a live load, and consequently, the effect of the cross beam is not so insignificant that it can be neglected.

Analysis of Rolled Beam Bridge by means of Specially Orthotropic Laminates Theory (특별직교이방성 적층판이론에 의한 압연형교의 해석)

  • Han, Bong-Koo;Lee, Chang-Soo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.3
    • /
    • pp.35-40
    • /
    • 2010
  • The specially orthotropic plate theory is used for analysis of panels made of girders and cross-beams. The cross-sections of both girders and cross-beams are H-types. The results of application of this method to rolled beam bridge by using specially orthotropic plate theory is presented. The result is compared with that of the beam theory. Finite difference method is used for this purpose. The influence of the $D_{22}$ stiffness on the natural frequency is rigorously investigated. According to numerical examination given in this paper, the result by the plate theory is 2.43 times stiffer than that of beam theory.

  • PDF

A Experimental Study on Bending Behaviors of Prestressed Hot-rolled H-Beam (프리스트레스된 압연강재보(H-BEAM)의 휨 거동에 대한 실험적 연구)

  • Yhim, Sung Soon;Jeong, Chan Haek
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.239-250
    • /
    • 2006
  • In this study, the experimental bending behaviors of an H-secti on-steel-beam-attached high-strength steel plate or steel beam were analyzed. Its structural performance was verified by comparing the results of the experiment and the analysis that were conducted. In fabricating an unprestressed composite beam using two members that have different strengths, the generated slip on the joint in proport problem because of the redistribution of force caused by the lose state of the joint. Therefore, when fabricating composite beams, it is important to load them with prestressed forces. Based on the results of the experiment that was conducted, the prestressed composite-steel-beam-attached steel plate or beam has a higher bending resistance and load-carrying capacit

An Experimental Study on the Fire Resistance Capacity of Asymmetric Slimflor Beam (비대칭 H형강 슬림플로어 보의 내화 성능에 관한 실험적 연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Asymmetric Slimflor Beam had been unveiled with Thor beam (Hat beam) in Sweden since the late 1970s and had been developed by British Steen and SCI. In the major advanced countries in Europe after the early 1990s have interested in and developed this method, it has been concrened as the absence of hot-rolled section steel in the United Kingdom and welded of asymmetric section steel in Finland in the 2000s. It can be increase total floor area about 10%, save the interior and exterior materials, reduce the waste through reduction of the floor height. And it has more excellent fire resistance performance because less exposed than a regular composite steel beam in fire. This study is purpose that, a fire resistance performance of the Asymmetric Slimflor Beam in fire, it compared the temperature range with deflection of structure by fire behavior and load ratio of structure through change the shape of the steel cross-section in standard fire condition.

OPTIMAL PROCESSING AND SYSTEM MANUFACTURING OF A LASER WELDED TUBE FOR AN AUTOMOBILE BUMPER BEAM

  • Suh, J.;Lee, J.H.;Kang, H.S.;Park, K.T.;Kim, J.S.;Lee, M.Y.;Jung, B.H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.2
    • /
    • pp.209-216
    • /
    • 2006
  • A study has been conducted for an optimal processing and an apparatus for manufacturing a laser welded tube for one-body formed bumper beam. The tube dimensions used in calculation were the thickness of 1.4 mm, the diameter of 105.4 mm and the length of 2000 mm. The tube was formed of a cold rolled high strength steel plate(tensile strength of 600 MPa). The two-roll bending method was the optimal tube forming process in comparison with the UO-bending method, the bending method on the press brake, the multi-step continuous roll-forming method and the 3-roll bending method. Monitoring of the welding quality was conducted and the seam tracking along the butt-joint lengthwise to the tube axis was also examined. The longitudinal butt-joint was welded by using a $CO_2$ laser welding machine equipped with a seam tracker and a plasma sensor. The $CO_2$ laser tube welding machine could be used for precise seam tracking and real-time monitoring of the welding quality. As a result, the developed laser welded tube could be used for a one-body formed automobile bumper beam.

An Evaluation on the Shear Strength of New Type Shear Connectors for a Simple Steel-Concrete Composite Deck (초간편 강합성 바닥판 신형식 전단연결재의 전단내력 평가)

  • Yoon, Ki Yong;Kim, Sang Seup;Han, Deuk Cheon
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.519-528
    • /
    • 2008
  • A simple steel-concrete composite deck is developed for preventing the lateral torsional buckling of girders that are under construction and for reducing the term of works using H-shaped rolled beams as bridge girders. A new type of shear connectors is also developed for the composite behavior between a simple steel-concrete composite deck and the rolled beams by the connecting conditions between the deck and the girders. One is a connector bolt that is lengthened and split or tightened with two nuts and the other is an I-shaped rolled beam welded on a steel plate with a number of holes punched through the web. In this study, to estimate the shear strength of those shear connectors the push-out tests are performed and the test results are compared with that of the previous studies and the codes. The result of the push-out tests of the connector bolts showed that the shear performance is similar to that of the stud connector and revealed that the equation for the shear strength in the Korean Specification of Highway Bridge overestimates the shear capacity of the connector bolt whose diameter is larger than 19mm. From the push-out tests of punched I-shaped rolled beams with varying welding amounts, with the small amount of welding, shear capacity is governed by the shear capacity of welding. On the other hand, shear capacity is governed by the size of the punched I-shaped rolled beams, regardless of the amount of welding.

A Study on Resisting Force of H-Shaped Beam Using Glass Web Plate (유리 웨브를 사용한 H형 합성보의 내력에 관한 연구)

  • Son, Ki-Sang;Jeon, Chang-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.73-80
    • /
    • 2006
  • Generally beam design depends on the yielding and maximum strength of each member varying with its section shape. Web plate of H-shape beam has not been substituted with glass plate, because it is known that its strength and heat properties are different and it is limited to substitute the existing steel web with glass element. Ceiling height of each room should be decreased with more than 60-80cm due to the beam. Differently from this condition, glass web beam has a good point to see through it and sunshine can be penetrate into the other size especially when it is installed as of outside wall. And also, it can be safer due to controlling room inside easier, if the strength is applicate. This study is to show some applicability after finding out the properties using the test. The test members with a size of $1,600{\times}200{\times}300{\times}9mm$ being SS41 rolled steel having THK 9mm flange while having 8,10mm and reinforced glass 12mm thickness is bonded with epoxy bond under the condition of temperature $28^{\circ}C$, humidity 50%, bonding power 24Mpa. It is show reinforced glass has 5 times of fracture stress more than the common glass but $50{\sim}150%$ difference between these 2 kinds of glass was shown. Reinforce glass did not support the original upper flange after fracture but the common glass did the upper flange after unloading. Generally reinforced glass is stronger than the common one but the common glass having a part of crack on it, compared with reinforced glass having the overall fracture could be more useful in case of needing ductility.

Solution for the Improvement in Structural Design & Application of PEB System for the Standard Livestock Housing(2008) (표준축사 모델에서 PEB시스템의 적용 및 구조설계 개선방안)

  • Park, Man-Woo;Do, Byung-Ho;Song, Jun-Ik
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.17-28
    • /
    • 2009
  • PEB system is more economical when compared with structures commonly used Hot rolled and welded light H-beam was introduced in the Standard Livestock Housing. This study suggested more economical technology for structural design by the reduction of live load, relief of deflection limit and reduction of importance factor. And, when applying wind Load as a result of examination with Low Rise Building Systems Manual considering open model, we can know that when the wind load is big, enclosed model is more stable than open model. In short, Suggesting more economical model and providing the method to reduce natural disaster, by the application of PEB system and the development of technology for structural design, are considered to strengthen the competitive power of farmhouse.

  • PDF

Welding Characteristics of 400MPa Grade Hot Rolled H-beam(SHN400) for Building Structure (400MPa급 건축구조용 열간압연 H형강(SHN400)의 용접특성)

  • Kim, Hee-Dong;Yang, Jae-Geun;Lee, Eun-Taik;Kim, Woo-Bum;Oh, Young-Suk
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.129-136
    • /
    • 2012
  • This study seeks to evaluate the welding characteristics of SHN400 steel, which is suitable for the steel material used in building structures in KS. For this purpose, the Y-groove weld crack test and hardness, tensile, bending, cross tensile, and charpy V notch tests at the welding point were conducted with specimens taken from the highest, the thickest and the commonly used H-beams for girder or beam members. Each test was conducted under the KS test conditions. All tests results satisfied the requirements of KS and the welding requirements for the proper inelastic behavior of structure, indicating that SHN400 can be used for the building structure as a structural material.