• Title/Summary/Keyword: rods

Search Result 1,114, Processing Time 0.026 seconds

A Study on the Permanent Design of Rods Each Number (Rod 호수에 따른 Permanent Design 연구)

  • Lee, Su-Hee;Cho, Koh-Mi
    • Journal of Fashion Business
    • /
    • v.12 no.2
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study is to explore to determine the maximum volume with doing permanent waving in flat crown of the head. The method was like this. First of all, the diameter, the ratio of the circumference of a circle to its diameter and the number of rotations were analyzed same hair using permanent waving rods each number of 1$\sim$10. Secondly, the increasing rate of volume of curls number of 1$\sim$10 was analyzed. According to the result of the experiment, as the number of permanent waving rods were bigger, the ratio of the circumference of a circle to its diameter constant was increasing but the number of rotations was decreased. When the permanent waving rods of each number 1-3(Big diameter) were used, the volume was decreased. That's because there was fewer rotation compared to the diameter and was no ample combed dried hair. Due to this kind of reason, there was no perfect curling. Once number 10 permanent waving rods (most small size) was used, the shape of curling was strong and the stability was made after combed dried hair. But volume was decreased by 9% because of the cohesive power. In case of number of 4$\sim$9 rods used, volume was increased. Volume was highest when permanent waving rods was number 5 which was used combing on base both morphology and numerical value.

Possibility of curium as a fuel for VVER-1200 reactor

  • Shelley, Afroza;Ovi, Mahmud Hasan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.11-18
    • /
    • 2022
  • In this research, curium oxide (CmO2) is studied as fuel for VVER-1200 reactor to get an attention to its energy value and possibilities. For this purpose, CmO2 is used in fuel rods or integrated burnable absorber (IBA) rods with and without UO2 and then compared with the conventional fuel assembly of VVER-1200 reactor. It is burned to 60 GWd/t by using SRAC-2006 code and JENDL-4.0 data library. From these studies, it is found that CmO2 is competent like UO2 as a fuel due to higher fission cross-section of 243Cm and 245Cm isotopes and neutron capture cross-section of 244Cm and 246Cm isotopes. As a result, when some or all of the UO2 of fuel rods or IBA rods are replaced by CmO2, we get a similar k-inf like the reference even with lower enrichment UO2 fuels. These studies show that the use of CmO2 as IBA rods is more effective than the fuel rods considering the initially loaded amount, power peaking factor (PPF), fuel temperature and void coefficient, and the quality of spent fuel. From a detailed study, 3% CmO2 with inert material ZrO2 in IBA rods are recommended for the VVER-1200 reactor assembly from the once through concept.

The Comparasion of the Dynamic Stereoacuity with Two-Rods Test and Three-Rods Test (이간계와 삼간계를 이용한 동적 입체시의 비교)

  • Shim, Hyun-Suk;Kim, Sang-Moon;Kim, Sang-Hyun;Kim, Young-Cheong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.377-384
    • /
    • 2015
  • Purpose: On this study, we measured and compared the dynamic stereoacuity by two-rods test (Howard-Dolman Test) and three-rods test. And we analyzed the correlation between PD and refractive error with dynamic stereoacuity. Methods: Dynamic stereoacuity of two-rods test and three-rods test at 2.5 m distance for 93 adults 93 (50 males, 43 females), mean age of $21.27{\pm}2.32$ (19~32) years old, were measured 5 times for two tests. Results: The mean of dynamic stereoacuity measured by two-rods test and three-rods test were $29.91{\pm}23.03sec$ of arc and $23.75{\pm}21.65sec$ of arc for total subjects, respectively. The mean of male and female were $36{\pm}22.38sec$ of arc and $22.28{\pm}23.79$, respectively. Three-rods test showed better dynamic stereoacuity than two-rods test, but there was no statistically significant difference (p>0.05). For the average standard deviation of PD between 60.63 mm~66.19 mm, dynamic stereoacuity fo two-rod test and three-rod test were $31.48{\pm}24.87sec$ of arc and $31.48{\pm}24.87sec$ of arc, respectively. The results showed statistically significant difference (p<0.05), but the relationship between dynamic stereoacuity and PD was not great. Comparison between two tests on the basis of refractive error, dynamic stereoacuity by three-rods test was better than by two-rods test with no significant difference between both tests (p>0.05) and there was little correlation between refractive error and two dynamic stereoacuity. Conclusions: Three-rods test showing lower stereoacuity than two-rods tests could measure the lower minimum threshold of dynamic stereoacuity. It was found that both tests can be applied to dynamic stereoacuity test as a standard test, and PD and refractive error was found that little effect upon the dynamic stereoacuity. PD and refractive error was found that little effect upon the dynamic stereoacuity.

Darkfield microscopic study of the bacterial morphotypes in the periodontal pockets of Korean adult periodontitis patients (한국 성인형 치주염 환자의 치주낭 내 세균분포에 관한 암시야현미경적 연구)

  • Park, Jung-Min;Nam, Ki-Yoon;Lee, In-Kyeong;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.2
    • /
    • pp.247-257
    • /
    • 2003
  • The purpose of this study was to evaluate the difference of subgingival bacterial compositions between periodontally healthy and diseased sites. Subgingival plaque samples were obtained from 100 sites in 20 untreated adult periodontitis patients(experimental group), and 100 sites in healthy individuals(contro1 group). Before sampling, probing pocket depth(PPD) and clinical level of attachment(CAL), Plaque Index(PI), and Sulcus Bleeding Index(SBI) were recorded for each sampled sites. Microbial samples were collected from the bases of gingival sulci or periodontal pockets with sterile curettes. The samples were examined under darkfield microscope(${\times}$400). At least 150 bacteria were evaluated and categorized on the basis of bacterial morphology and motility, i.e. cocci, non-motile rods, motile rods, and spirochetes. In control group, subgingival microbial flora consisted of 73.7% of cocci, 20.0% of non-motile rods, 4.3% of motile rods, and 2.0% of spirochetes. The microbial samples from experimental group consisted of 51.5% of cocci, 19.4% of non-motile rods, 17.6% of motile rods, and 11.6% of spirochetes. The proportion of cocci was higher in control group than in experimental group. Proportions of motile rods and spirochetes were higher in experimental group than in control group. The proportion of nonmotile rods in experimental group and control group was not significantly different. Sulcus Bleeding Index and Plaque Index showed high correlation with the bacterial composition. These findings suggests that examination of subgingival bacterial proportion may serve as more sensitive mirror of the local periodontal status than clinical parameters.

A study on hot extru-pressure welding of aluminum rods (알루미늄 봉재의 열간 압출압접에 관한 연구)

  • Lee, Kyeng-Kook;Jin, In-Tai
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.34-38
    • /
    • 2008
  • It was investigated that two rods of aluminium can be welded by hot extru-pressure welding method with stepped welding dies, and that the welding pressure on the welding surface were analyzed by computer simulation according to the stepped shapes of welding dies. It was known by computer simulation that welding pressure on the welding section of rods welded using stepped welding dies. And it was known by experime- nts that two rods of aluminium can be welded on the end sections by hot pressure welding method using stepped welding dies without relative rotational movement of contacted aluminium rods needed for the purpose of friction heating and pressure.

  • PDF

A Study on the Driving of Rods in Hydraulic Bent-axis-type Axial Piston Pump Part 1: The Theoretical Analysis of Driving Mechanism (유압 사축식 액셜 피스톤 펌프의 로드 구동에 관한 연구 제1보: 구동 메카니즘의 이론해석)

  • 김종기;오석형;정재연
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.51-57
    • /
    • 1998
  • Recently, bent-axis-type axial piston pumps driven by rods being in extensively used in the world, because of simple design, lightweight, effective cost. So, to guarantee the quality of bent-axis-type axial piston pumps driven by rods, it is necessary to know characteristics of the driving mechanism of rods. But, as they perform both reciprocating and spinning motions, it is difficult to understand driving mechanism. In this paper, I studied the theoretical driving mechanisms of cylinder block driven by rods through geometric method. I found that the cylinder block was driven by one rod in limited area and the driving area was changed by rod's tilting angle and cylinder block's swivel angle.

Cyclic test of buckling restrained braces composed of square steel rods and steel tube

  • Park, Junhee;Lee, Junho;Kim, Jinkoo
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.423-436
    • /
    • 2012
  • In this study total of six buckling-restrained braces (BRBs) were manufactured using a square steel rod as a load-resisting core member and a hollow steel tube as restrainer to prevent global buckling of the core. The gap between the core and the tube was filled with steel rods as filler material. The performances of the proposed BRB from uniaxial and subassemblage tests were compared with those of the specimens filled with mortar. The test results showed that the performance of the BRB with discontinuous steel rods as filler material was not satisfactory, whereas the BRBs with continuous steel rods as filler material showed good performance when the external tubes were strong enough against buckling. It was observed that the buckling strength of the external tube of the BRBs filled with steel rods needs to be at least twice as high as that of the BRBs filled with mortar to ensure high cumulative plastic deformation of the BRB.

Effect of Turbulence Promoter Width on Heat Transfer Augmentation in Impinging Air Jet System (충돌공기분류계(衝突空氣噴流系)에서 난류촉진체(亂流促進體)의 폭변화(幅變化)가 전열증진(傳熱增進)에 미치는 영향(影響))

  • Kum, S.M.;Seo, J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.427-438
    • /
    • 1994
  • This experimental study was earned out to examine the heat transfer characteristics of a 2-dimensional impinging air jet on a flat plate with a set of square rods. The objectives of the study were to investigate the flow and heat transfer characteristics caused by the square rods and to find out the optimum rods arrangement. Experiment was carried out first without using the rods to establish the baseline heat transfer performance. Then, rods of different widths and clearances were installed to cause the turbulence on the fluid flow.

  • PDF

The analysis of driving mechanism of rods in bent-axis-type axial piston pump (사축식 Axial Piston Pump의 Rod 구동 메카니즘 해석)

  • 김종기;정재연
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.76-85
    • /
    • 1997
  • Recently, bent-axis-type axial piston pumps drived by rod being in extensively used in the world, because of simple design, lightweight, effective cost. So, to guarantee the quality of bent-axis-type axial piston pumps drived by rods, it is necessary to know chracteristics of the forces applied to rods and the driving mechanism of rods. But, as they perform both reciprocating and spinning motions, it is difficult to understand driving mechanism. In this paper, I explained the theoretical driving mechanisms of cylinder block drived by rods through geometric method and the characteristics of the forces applied to them.

  • PDF

The preparation of Al-Si alloy welding rod by the horizontal continuous casting process with the heating mold (가열주형 수평식연속주조법에 의한 Al-Si 합금 용접봉 제조)

  • 김원태;김명한;이보영
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.101-108
    • /
    • 1994
  • The horizontal continuous casting process with the heating mold was adopted for fabricating defect-free 4043 Al alloy rods of 3.2m dia. with mirror surfaces. These rods were drawn into 2.4mm dia. rods for GTAW welding. The GTAW welding tests were carried out by use of these welding rods with 6061 Al alloy as a base metal. After welding, the X-ray tests, tensile strength tests, bending tests, and microstructural analysis of welded zone and HAZ were carried out. The results represented that the welding rods with good surfaces and welding properties could be made by the horizontal continuous casting, and followed by the drawing process.

  • PDF