• Title/Summary/Keyword: rods

Search Result 1,116, Processing Time 0.029 seconds

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Developing a Dental Unit Waterline Model Using General Laboratory Equipments (실험실 일반 장비를 이용한 치과용 유니트 수관 모델 개발)

  • Yoon, Hye Young;Lee, Si Young
    • Journal of dental hygiene science
    • /
    • v.16 no.4
    • /
    • pp.284-292
    • /
    • 2016
  • Water supplied through dental unit waterlines (DUWLs) has been shown to contain high number of bacteria. To reduce the contamination of DUWLs, it is essential to develop effective disinfectants. It is, however, difficulty to obtain proper DUWL samples for studies. The purpose of this study was to establish a simple laboratory model for reproducing DUWL biofilms. The bacteria obtained from DUWLs were cultured in R2A liquid medium for 10 days, and then stored at $-70^{\circ}C$. This stock was inoculated into R2A liquid medium and incubated in batch mode. After 5 days of culturing, it was inoculated into the biofilm formation model developed in this study. Our biofilm formation model comprised of a beaker containing R2A liquid medium and five glass rods attached to DUWL polyurethane tubing. Biofilm was allowed to form on the stir plate and the medium was replaced every 2 days. After 4 days of biofilm formation in the laboratory model, biofilm thickness, morphological characteristics and distribution of the composing bacteria were examined by confocal laser microscopy and scanning electron microscopy. The mean of biofilm accumulation was $4.68{\times}10^4$ colony forming unit/$cm^2$ and its thickness was $10{\sim}14{\mu}m$. In our laboratory model, thick bacterial lumps were observed in some parts of the tubing. To test the suitability of this biofilm model system, the effectiveness of disinfectants such as sodium hypochlorite, hydrogen peroxide, and chlorhexidine, was examined by their application to the biofilm formed in our model. Lower concentrations of disinfectants were less effective in reducing the count of bacteria constituting the biofilm. These results showed that our DUWL biofilm laboratory model was appropriate for comparison of disinfectant effects. Our laboratory model is expected to be useful for various other purposes in further studies.

Electrochemical Characteristics of LiMn2O4 Cathodes Synthesized from Various Precursors of Manganese Oxide and Manganese Hydroxide (다양한 형태 및 구조의 망간산화물 및 망간수산화물 전구체로부터 합성한 LiMn2O4양극의 전기화학적 특성 연구)

  • Lee, Jong-Moon;Kim, Joo-Seong;Hong, Soon-Kie;Lee, Jeong-Jin;Ahn, Han-Cheol;Cho, Won-Il;Mho, Sun-Il
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.172-180
    • /
    • 2012
  • The $LiMn_2O_4$ cathodes for lithium ion battery were synthesized from various precursors of manganese oxides and manganese hydroxides. As the first step, nanosized precursors such as ${\alpha}-MnO_2$ (nano-sticks), ${\beta}-MnO_2$ (nano-rods), $Mn_3O_4$ (nano-octahedra), amorphous $MnO_2$(nano-spheres), and $Mn(OH)_2$ (nano-plates) were prepared by a hydrothermal or a precipitation method. Spinel $LiMn_2O_4$ with various sizes and shapes were finally synthesized by a solid-state reaction method from the manganese precursors and LiOH. Nano-sized (500 nm) octahedron $LiMn_2O_4$ showed high capacities of 107 mAh $g^{-1}$ and 99 mAh $g^{-1}$ at 1 C- and 50 C-rate, respectively. Three dimensional octahedral crystallites exhibit superior electrochemical characteristics to the other one-dimensional and two-dimensional shaped $LiMn_2O_4$ nanoparticles. After 500 consecutive charge discharge battery cycles at 10 C-rate with the nano-octahedron $LiMn_2O_4$ cathode, the capacity retention of 95% was observed, which is far better than any other morphologies studied in this work.

Studies on the Nature and Pathogenicity of Nuclear Polyhedrosis Virus of the Fall Webworm, Hyphantria cunea (Drury) (흰불나방 핵다각체병바이러스의 성상과 병원성에 관한 연구)

  • Im Dae Joon;Hyun Jae Sun;Paik Woon Hah;Lim Jong Sung
    • Korean journal of applied entomology
    • /
    • v.18 no.1 s.38
    • /
    • pp.1-10
    • /
    • 1979
  • An inclusion forming virus isolated from a fan webworm, Hyphantria cunea, in 1975 was identified as a nuclear polyhedrosis virus. With the virus isolated in Korea, it was considered that the virus would be one of the valuable microorganism in microbial control. In this connection, 1) the shape and size of the virus for identification, 2) susceptibility of the various instar larvae to the virus, 3) the effects of storage condition on the pathogenicity and the cross infection of the virus to the larvae of Bombyx mori were examined. The results are summarized as follows; 1. The polyhedron was tetrahedron or hexahedron of $2\mu$ in size and the rod-shaped virus particles consisting of $2\~14$ rods in a bundle were $330m{\mu}\times35m{\mu}$ in size. 2. The hexagonal nuclear polyhedra were found only in the nucleus of the midgut cells but were variable in size. 3. The $LD_{50}$ values for the various instar larvae of H. cunea were $8.377\times10^4\;PIBs/ml$ for the second, $4.974\times10^5\;PIBs/ml$ for the fifth instar larvae. The $LT_{50}values$ for $10^6\;PIBs/ml$ were 9.6 days for the second, 11.5 days for the third, 12.0 days for the fourth and 17 days for the fifth instar larvae. 4. The susceptibility of H. cunea to the nuclear polyhedrosis virus was greater in the first generation than in the second generation. 5. The effect of the storage conditions on the pathogenicity of the nuclear polyhedra was less in refrigerator $(5^{\circ}C)$ and in freezing $(-80^{\circ}C)$ than in room temperature $(18.5^{\circ}C)$, especially as air-dried polyhedra than as suspension. The pathogenicity of the polyhedra seemed to decrease by sunlight during storage as cadavers, since rather greater decrease in pathogenicity was found in sunny condition than in shady condition. 6. The effective spray concentration was $6.4\times10^7\;PIBs/ml$ in the field and its $LT_50$ values for the third and the fifth instar larvae were 4.8 days and 14.2 days, respectively. 7. No cross infections were found in the nuclear polyhedrosis virus between H. cunea and B. mori. larvae.

  • PDF

Peritoneal Dialysis-related Peritonitis in Children: A Single Center's Experience Over 12 Years (소아 복막 투석 환자에서 발생한 복막염 : 단일기관에서 12년간의 경험)

  • Oh, Seong Hee;Lee, Yoon Jung;Lee, Jina;Lee, Joo Hoon;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.16 no.2
    • /
    • pp.80-88
    • /
    • 2012
  • Purpose: The aim of our study was to investigate the characteristics of the peritoneal dialysis (PD) - related peritonitis and to evaluate the effectiveness of the empirical antibiotics recommended by the International Society for Peritoneal Dialysis in Korean children. Methods: We retrospectively reviewed the medical records of 72 children on peritoneal dialysis at the Department of Pediatrics, Asan Medical Center over the period from March 2000 to February 2012. Results: Seventy-nine episodes of peritonitis occurred in 32 patients. The incidence of peritonitis was 0.43 episodes/patient year. There were no significant differences in the incidence of peritonitis in terms of dialysis modality (P=0.459). Twenty-one patients experienced 51 catheter exit-site infections (0.28 episode/patient year). There were no significant differences in the incidence of peritonitis between those with and without history of exit-site infections (P=0.721). Specific pathogens were isolated from 68.4% (54/79) of the patient with peritonitis episodes, including Gram-positive bacteria (n=34), Gram-negative bacteria (n=25) and fungus (n=1). Among Gram-positive bacteria, 85.3% of the isolates were susceptible to ${\beta}$-lactam antibiotics, among Gram-negative rods, 94.7% of the isolates were susceptible to ceftazidime. Among 25 cases with unknown etiologies, 92.0% of cases demonstrated satisfactory responses to cefazolin and ceftazidime. Conclusions: The incidence of peritonitis was 0.43 episodes/patient year. Initial empirical therapy consisting of cefazolin and ceftazidime was appropriate for 91.1% of the PD-related peritonitis treatment. Continuous monitoring for the emergence of the resistant organisms is an important part of the appropriate managements of PD-related peritonitis.

Evaluating applicability of metal artifact reduction algorithm for head & neck radiation treatment planning CT (Metal artifact reduction algorithm의 두경부 CT에 대한 적용 가능성 평가)

  • Son, Sang Jun;Park, Jang Pil;Kim, Min Jeong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • Purpose : The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head & neck radiation treatment planning CT with metal artifact created by dental implant. Materials and Methods : All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120kVp, 2mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). Results : In cases of head&neck phantom, the difference of dose distibution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. Conclusion : The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area even turned tissue HU by wrong correction was founded, too. Consequentially, It seems O-MAR algorithm is not perfect to distinguish air cavity and photon starvation artifact. Nevertheless, the differences of HU and dose distribution are not a huge that is not suitable for clinical use. And there are more advantages in clinic for improved quality of CT images and DRRs, precision of contouring OARs or tumors and correcting artifact area. So original and O-MAR CT must be used together in clinic for more accurate treatment plan.

Clinical Implication of Serum TNF-$\alpha$ and IL-1$\beta$ Measurement in Patients with Sepsis (패혈증환자에서 혈청 TNF-$\alpha$ 및 IL-1$\beta$)

  • Kim, Jae-Yeol;Choi, Hyung-Seok;Lee, Choon-Taek;Kim, Young-Whan;Han, Sung-Koo;Min, Kyung-Up;Kim, Yoo-Young;Shim, Young-Soo;Yoo, Chul-Gyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.2
    • /
    • pp.217-224
    • /
    • 2000
  • Background : It is well known that when macrophages are stimulated with endotoxin, they produce a wide variety of cytokine mediators, including TNF-$\alpha$ and IL-1$\beta$. However, there is an alteration in the macrophages' responsiveness when they are challenged with repeated bouts of endotoxin, termed "endotoxin tolerance" which is regarded as a self-protective phenomenon from continuous stimulation. In this study, endotoxin tolerance in the peripheral blood monocytes of sepsis patients was evaluated. Methods : Fourteen patients with organism-documented sepsis were included. The severity of illness was evaluated by APACHE II score. Peripheral blood monocytes were isolated from the patients and diluted to $1{\times}10^5$ well. After stimulation with endotoxin (LPS of E. coli O114 : B4, 100 ng/ml), they were incubated at $37^{\circ}C$ in 5% $CO_2$ incubator for 24 hours. Supernatant was collected for the measurement of TNF-$\alpha$ and IL-1$\beta$ with ELISA method. Peripheral blood monocytes of seven healthy volunteers were used as control. Results : The APACHE II score (mean$\pm$SD) of the patients at the time of blood sampling was 12.2$\pm$5.7. The primary infection foci were urinary tract infection, pneumonia, subacute bacterial endocarditis, and catheter related infection, etc. The causative organisms were gram negative rods (10 cases), gram positive cocci (6 cases) with two cases of mixed infection. Serum TNF-$\alpha$ could be measured in 4 cases with 29.9$\pm$27.7 pg/ml. Serum IL-1$\beta$was measurable in only one patient. The TNF-$\alpha$ level of supernatant of cultured peripheral blood monocytes was 2,703$\pm$2,066 pg/ml in patients and 2,102$\pm$1914 pg/ml in controls. The IL-1$\beta$level of supernatant was 884$\pm$1,050 pg/ml in patients and 575$\pm$558 pg/ml in controls. There was no difference of TNF-$\alpha$ and IL-1$\beta$ level between patients and controls. Conclusion : We cannot prove the phenomenon of endotoxin tolerance in this study. Future study needs to be focused on the more severe sepsis patients who were taken for sampling earlier. Addition of serum to the culture medium could be an another valuable option for the success of this study.

  • PDF

Experimental study on the ground subsidence due to the excavation of a shallow tunnel (경사지반에서 얕은터널의 굴착에 따른 지표침하에 대한 실험적 연구)

  • Park, Chan Hyuk;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.761-778
    • /
    • 2017
  • The need of the underground space for the infrastructures in urban area is increasing, and especially the demand for shallow tunnels increased drastically. It is very important that the shallow tunnel in the urban area should fulfill not only its own safety conditions but also the safety condition for the adjacent structures and the surrounding sub-structure. Most of the studies on the behavior of shallow tunnels concentrated only on their behaviors due to the local deformation of the tunnel, such as tunnel crown or tunnel sidewall. However, few studies have been performed for the behavior of the shallow tunnel due to the deformation of the entire tunnel. Therefore, in this study the behavior of the surrounding ground and the stability caused by deformation of the whole tunnel were studied. For that purpose, model tests were performed for the various ground surface slopes and the cover depth of the tunnel. The model tunnel (width 300 mm, height 200 mm) could be simulationally deformed in the vertical and horizontal direction. The model ground was built by using carbon rods of three types (4 mm, 6 mm, 8 mm), in various surface slopes and cover depth of the tunnel. The subsidence of ground surface, the load on the tunnel crown and the sidewall, and the transferred load near tunnel were measured. As results, the ground surface subsided above the tunnel, and its amount decreased as the distance from the tunnel increased. The influence of a tunnel ceased in a certain distance from the tunnel. At the inclined ground surface, the wider subsidence has been occurred. The loads on the crown and the sidewall were clearly visible, but there was no effect of the surface slope at a certain depth. The load transfer on the adjacent ground was larger when the cover depth (on the horizontal surface) was lager. The higher the level (on the inclined surface), the wider and smaller it appeared. On the shallow tunnel under inclined surface, the transfer of the ambient load on the tunnel sidewall (low side) was clearly visible.