• 제목/요약/키워드: robot surgery

검색결과 130건 처리시간 0.034초

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권1호
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.

Effects of Gait Training Using a Robot for Balance in Total Hip Arthroplasty Patients after Bilateral Avascular Necrosis: A Case Study

  • Kim, So-Yeong;Kim, Byeong-Geun;Cho, Woon-Su;Park, Chi-Bok
    • The Journal of Korean Physical Therapy
    • /
    • 제33권5호
    • /
    • pp.231-237
    • /
    • 2021
  • Purpose: This study sought to investigate the effects of robot-assisted gait training on balance in total hip arthroplasty (THA) patients after bilateral avascular necrosis (AVN). Methods: This case study in two patients utilized an 'A-B-A' single-subject experimental design that included five days of pre-intervention, followed by five days of intervention, and five days of post-intervention. The intervention involved the use of a standing inclined robot (R-bot) for 15 minutes. The outcome measures were evaluated using the Functional Reaching Test (FRT), Time Up to Go (TUG), and the Modified One Leg Standing Test (OLST). Results: Patient 1 showed improvement based on data gathered from baseline A to intervention period B, with results as follows: FRT improved from 27.7 cm to 41.28 cm, OLST LT from 14.03 seconds to 67.37 seconds, OLST RT from 2.94 seconds to 35.97 seconds, and TUG from 12.96 seconds to 7.82 seconds. Patient 2 also showed improvement from baseline A to intervention period B, with results as follows: FRT improved from 17.18 cm to 24.3 cm, OLST LT from 11.53 seconds to 52.01 seconds, OLST RT from 12.99 seconds to 62.19 seconds, and TUG from 27.31 seconds to 12.99 seconds. Conclusion: Based on the results of this study, robotic rehabilitation during the early stages after surgery is effective for promoting balance in patients who have undergone THA due to bilateral AVN.

미세수술용 매니퓰레이터의 개발을 위한 미세수술 작업 분석 (Analysis of microsurgery task for developing microsurgery manipulator)

  • 송세경;김완수;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1631-1634
    • /
    • 1997
  • Since surgery is usually a difficult task because of physiological tremor, eye strain, and tremor, contagious and radioactive hazard, it is necessary to develop micro-surgery telerobotic system using improved tools suitable for their specific tasks. Nowadays the growth of interest on microsurgery and medical applications of robotics has been so rapid. But the medical robots are only practical applications of the industrial robots. This paper identifies five general areas of advanced microsurgery based on the current technological background and expertise, and analyzes the motion, tool and accuracy with respect to microsurgery task, and proposed the criteria to evaluate micro-surgical manipulator. The analysis of microusrgery can be heplful to clarify some basic concept and design of micro-surgical manipulators. With these data we will alos propose an efficient in-parallel-platform manipulator having special kinematic structrue structure suitable for microsurgery.

  • PDF

척추 융합 수술을 위한 삼차원 척추경 모델을 이용한 자동 수술 계획 시스템 (Automated Surgical Planning System for Spinal Fusion Surgery with Three-Dimensional Pedicle Model)

  • 이종원;김성민;김영수;정완균
    • 제어로봇시스템학회논문지
    • /
    • 제17권8호
    • /
    • pp.807-813
    • /
    • 2011
  • High precision of planning in the preoperative phase can contribute to increase operational safety during computer-aided spinal fusion surgery, which requires extreme caution on the part of the surgeon, due to the complexity and delicacy of the procedure. In this paper, an advanced preoperative planning framework for spinal fusion is presented. The framework is based on spinal pedicle data obtained from CT (Computed Tomography) images, and provides optimal insertion trajectories and pedicle screw sizes. The proposed approach begins with safety margin estimation for each potential insertion trajectory that passes through the pedicle volume, followed by procedures to collect a set of insertion trajectories that satisfy operation safety objectives. The radius of a pedicle screw was chosen as 70% of the pedicle radius. This framework has been tested on 68 spinal pedicles of 8 patients requiring spinal fusion. It was successfully applied, resulting in an average success rate of 100% and a final safety margin of $2.44{\pm}0.51mm$.

최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상 (Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery)

  • 박현준;원종석;박재흥
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

Pelvic floor muscle exercise with biofeedback helps regain urinary continence after robot-assisted radical prostatectomy

  • Kim, Yeong Uk;Lee, Dong Gyu;Ko, Young Hwii
    • Journal of Yeungnam Medical Science
    • /
    • 제38권1호
    • /
    • pp.39-46
    • /
    • 2021
  • Background: To determine the benefit of pelvic floor muscle exercise (PFME) with visual biofeedback on promoting patient recovery from incontinence, we investigated variables associated with the early restoration of continence for patients who underwent robot-assisted radical prostatectomy (RARP). Methods: Of the 83 patients enrolled, 41 consecutive patients completed PFME (the exercise group), and the other 42 consecutive patients just before the PFME program commenced (the control group). The primary outcome was whether PFME engagement was associated with zero pad continence restoration within 3 months of surgery. Results: Continence restoration percentages (defined as zero pads used per day) at 1, 3, and 6 months after surgery were 49.4%, 77.1%, and 94.0%, respectively. The exercise group achieved significantly higher recovery rates at 1 month (p=0.037), 3 months (p<0.001), and 6 months (p=023). Cox regression analysis demonstrated that a lower Gleason score (<8; hazard ratio [HR], 2.167), lower prostate specific antigen (<20 ng/dL; HR, 2.909), and engagement in PFME (HR, 3.731) were independent predictors of early recovery from postprostatectomy incontinence. Stratification by age showed that those younger than 65 years did not benefit significantly from exercise (log-rank test, p=0.08), but that their elderly counterparts, aged 65-70 years (p=0.007) and >70 years old (p=0.002) benefited significantly. Conclusion: This study suggests that postoperative engagement in PFME with biofeedback speeds up the recovery of continence in elderly patients (≥65 years old) that undergo RARP.

승모판 성형술에 있어 최초 침습적 수술방식과 고전적 정중 흉골 절개술을 통한 접근방식의 비교 (Comparison of Mitral Valve Repair between a Minimally Invasive Approach and a Conventional Sternotomy Approach)

  • 조원철;제형곤;김정원;이재원
    • Journal of Chest Surgery
    • /
    • 제40권12호
    • /
    • pp.825-830
    • /
    • 2007
  • 배경: 최소 침습적 심장 수술은 전통적인 정중 흉골 절개술에 비해 수술 후 조기 회복 및 우수한 미용적 효과 등의 장점이 있지만 승모판막 성형술과 같이 복잡한 개심술에서의 성적은 아직 국내에 보고된 바 없다. 본 연구에서는 승모판 폐쇄 부전증의 환자군에서 로봇을 이용한 최소 침습적 승모판 성형수술의 유용성에 관해 정중 흉골 절개술과 비교하여 알아보고자 하였다. 대상 및 방법: 1993년 12월부터 2005년 12월까지 승모판막 폐쇄 부전으로 승모판막 성형술을 시행받은 520명의 환자를 연구대상으로 하였다. 이 중 정중 흉골 절개술을 통하여 승모판 성형술을 시행한 군을 S군(n=432), 최소 침습적 우측 개흉술을 이용한 환자군을 M군(n=88)으로 하여 임상 결과를 비교하였다. 우측 개흉술시에는 AESOP (Automated Endoscopic System for Optimal Positioning) 3000이라는 로봇을 이용하여 5 cm 이하의 절개로 수술을 시행하였다. 결과: 양 군 간의 나이, 성별, 수술 전 좌심실 구출률 등은 양 군 간의 차이는 없었다. S군에서 2예의 조기 사망이 있었으나 M군에서는 수술 사망예가 없었다. M군이 대동맥 차단 시간과 심폐기 가동 시간은 S군에 비해 유의하게 길었지만, 중환자실 재원기간과 수술 후 재원 일수는 S군에 비해 유의하게 짧았다. 제한된 절개에도 M군에서 승모판막 성형술식에 사용된 수술 술기는 제한이 없었으며, 술 후 의미있는 잔존 승모판막 폐쇄부전증의 빈도는 양 군에서 유사하였다 결론: 최소 침습적 우측 개흉술을 통한 승모판막 성형술을 시행하더라도 조기 성적은 차이가 없었다. 향후 최소 침습적 승모판막 성형술의 중-장기 성적의 관찰을 요하며 본 연구를 바탕으로 승모판막 성형술의 일차적인 접근 방법으로 최소 침습적 개흉술이 보다 폭넓게 시행될 수 있을 것으로 기대한다.

Emerging Role of Robot-assisted Gastrectomy: Analysis of Consecutive 200 Cases

  • Park, Ji Yeon;Kim, Young-Woo;Ryu, Keun Won;Eom, Bang Wool;Yoon, Hong Man;Reim, Daniel
    • Journal of Gastric Cancer
    • /
    • 제13권4호
    • /
    • pp.255-262
    • /
    • 2013
  • Purpose: Robotic surgery for gastric cancer is a promising alternative to laparoscopic surgery, but the data are limited. We aimed to evaluate whether gaining experience in robotic gastrectomy could improve surgical outcomes in the treatment of gastric cancer. Materials and Methods: Two hundred and seven consecutive cases of patients with clinical stage I gastric cancer who underwent robotic surgery at the National Cancer Center of Korea between February 2009 and February 2012 were retrospectively reviewed. Surgical outcomes were analyzed and compared between the initial 100 and later 100 cases. Results: Seven patients required conversion to open surgery and were excluded from further analysis. The mean operating time for all patients was 248.8 minutes, and mean length of hospitalization was 8.0 days. Twenty patients developed postoperative complications. Thirteen were managed conservatively, while 6 had major complications requiring invasive procedures. One mortality occurred owing to myocardial infarction. Operating time was significantly shorter in the latter 100 cases than in the initial 100 cases (269.9 versus 233.5 minutes, P<0.001). The number of retrieved lymph nodes was significantly greater in the latter cases (35.9 versus 39.9, P=0.032). The hospital stay of patients with complications was significantly longer in the initial cases than in the latter cases (16 versus 7 days, P=0.005). Conclusions: Increased experience with the robotic procedure for gastric cancer was associated with improved outcomes, especially in operating time, lymph node retrieval, and shortened hospital stay of complicated patients. Further development of surgical techniques and technology might enhance the role of robotic surgery for gastric cancer.

Successful Robotic Gastrectomy Does Not Require Extensive Laparoscopic Experience

  • An, Ji Yeong;Kim, Su Mi;Ahn, Soohyun;Choi, Min-Gew;Lee, Jun-Ho;Sohn, Tae Sung;Bae, Jae-Moon;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • 제18권1호
    • /
    • pp.90-98
    • /
    • 2018
  • Purpose: We evaluated the learning curve and short-term surgical outcomes of robot-assisted distal gastrectomy (RADG) performed by a single surgeon experienced in open, but not laparoscopic, gastrectomy. We aimed to verify the feasibility of performing RADG without extensive laparoscopic experience. Materials and Methods: Between July 2012 and December 2016, 60 RADG procedures were performed by a single surgeon using the da $Vinci^{(R)}$ Surgical System (Intuitive Surgical). Patient characteristics, the length of the learning curve, surgical parameters, and short-term postoperative outcomes were analyzed and compared before and after the learning curve had been overcome. Results: The duration of surgery rapidly decreased from the first to the fourth case; after 25 procedures, the duration of surgery was stabilized, suggesting that the learning curve had been overcome. Cases were divided into 2 groups: 25 cases before the learning curve had been overcome (early cases) and 35 later cases. The mean duration of surgery was 420.8 minutes for the initial cases and 281.7 minutes for the later cases (P<0.001). The console time was significantly shorter during the later cases (168.6 minutes) than during the early cases (247.1 minutes) (P<0.001). Although the volume of blood loss during surgery declined over time, there was no significant difference between the early and later cases. No other postoperative outcomes differed between the 2 groups. Pathology reports revealed the presence of mucosal invasion in 58 patients and submucosal invasion in 2 patients. Conclusions: RADG can be performed safely with acceptable surgical outcomes by experts in open gastrectomy.