• Title/Summary/Keyword: river flow estimation

Search Result 247, Processing Time 0.029 seconds

Development of the Estimation Model on Daily Pollutant Loads for the Nakdong River Basin II. Application of the Model (낙동강 유역에 대한 일별 유달부하량 산정모델개발 II. 모델식의 활용)

  • Yoon, Young-Sam;Yu, Jae-Jeong;Kim, Moon-Soo;Lee, Hae-Jin;Lee, Jun-Bae;Yang, Sang-Yong
    • Journal of Environmental Science International
    • /
    • v.16 no.3
    • /
    • pp.333-345
    • /
    • 2007
  • As analyzed the estimated values of the daily delivery loads from thirteen major side streams such as Naesung-river, Keumho-river, Hwang-river, Nam-river during five years (from 1999 to 2003), the daily BOD inflow into the main stream of Nakdong river in 2003 shows the highest quantity as 31.1 ton and the daily BOD inflows in 1999, 2000, 2001, and 2002 are 26.7 ton, 22.5 ton, 21.0 ton, 25.8 ton, respectively. The daily TN in-flow into the main stream of Nakdong river in 2003 shows also the highest quantity as 64.9 ton and the daily TN inflows in 1999, 2000, 2001, and 2002 are 55.19 ton, 46.27 ton, 39.5 ton, 53.38 ton, respectively. The daily TP inflow into the main stream of Nakdong river in 2003 shows the highest quantity as 2.70 ton likewise and the daily TP inflows in 1999, 2000, 2001, and 2002 are 2.17 ton, 1.87 ton, 1.60 ton, 2.10 ton, respectively The rate of BOD loads from each side main stream into the main stream of Nakdong river shows that the BOD loads of Keumho-river are the highest as the values range from 32.8 % (2002) ${\sim}$ 35.1 % (2003) and the BOD loads of Nam-river, Naesung-river, Hwang-river are high in the order named. The rate of TN loads to the main stream is also similar to the trend of BOD loads. The contribution of the TN loads of Geumho-river to the contamination of the main stream is also the highest having a range from 27.0 % (2002) to 28.8 % (1999) among the main side streams and the TN loads of Naesung-river, Nam-river, and Heachun-river are high in the order named. The rate of TP loads is quite different from the trend of BOD and TN loads. The TP rate of Keumho-river, however, is still the highest as ranging 58.6 % (2002) to 61.7 % (2003) and the river has the biggest portion (over 50%) of the entire pollution to the main stream of Nakdong river.

Estimation of Habitats Suitability Index based on Hydraulic Conditions (수리조건을 이용한 생물서식처 적합도 지수 산정 -홍천강을 대상으로-)

  • Lee, Jae-Yil;Lee, Gyu-Sung;Ahn, Hong-Kyu;Ha, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.13 no.1
    • /
    • pp.149-160
    • /
    • 2011
  • This study developed a HSI for the creatures in Hongcheon River in order to analyze the conditions proper for habitats. For the index, the investigator identified a total of seven items encompassing hydraulic characteristics such as flow velocity and water depth, and water quality characteristics such as water temperature, BOD, DO, TN, and TP. The subject river was simulated, inspected, and revised with a two-dimensional river model (RMA-2) and water quality model (QUAL2E). Using GIS, the developed index was divided by section by reflecting river characteristics and compared and analyzed with the statistics. The river was divided into a total of 29 reaches by reflecting the basic characteristics and the features of the hydraulic coefficient on the cross-sections of the river. According to the analysis results, the fish scored the highest mean of the overall habitat suitability index of 0.769 at reach 27. Each of the variables had the following mean values: 0.122 m/s for flow velocity, 0.782m for water depth, $14.3^{\circ}C$ for water temperature, 0.68 mg/l for BOD, 10.3 mg/l for DO, 2.4 mg/l for TN, and 0.0121mg/l for TP.

Estimation of the Parameters for the Clark Model through the Rainfall-Runoff Events (강우 유출사상을 통한 Clark 모형의 매개변수 평가)

  • Ahn, Tae-Jin;Baek, Chun-Woo;Kim, Min-Hyuk;Choi, Kwang-Hoon;Kang, In-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.770-774
    • /
    • 2006
  • The determination of feasible design flood is the most important to control flood damage in river management. Model parameters should be calibrated using observed discharge but due to deficiency of observed data the parameters have been adopted by engineer's empirical sense. Storage coefficient in the Clark unit hydrograph method mainly affects magnitude of peak flood. This study is to estimate the storage coefficients based on the observed rainfall-runoff events at the four stage stations in the Hantan river basin. Model calibration is the process of adjusting model parameter values until model results match historical data. An objective function which is the percent difference between the observed and computed peak flows is available for measuring the goodness-of-fit between computed and observed hydrographs. By sensitivity analysis for the storage coefficient, it has been shown that the storage coefficients affect the peak flows. The Clark parameters adopted in the River Rectification Basic Plan have been estimated through an iterative process designed to produce a hydrograph with the peak flow.

  • PDF

Development of Topological Correction Algorithms for ADCP Multibeam Bathymetry Measurements (ADCP 다중빔 수심계측자료의 위상학적 보정 알고리즘 개발)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.22 no.5
    • /
    • pp.543-554
    • /
    • 2013
  • Acoustic Doppler Current Profilers (ADCPs) are increasingly popular in the river research and management communities being primarily used for estimation of stream flows. ADCPs capabilities, however, entail additional features that are not fully explored, such as morphological representation of river or reservoir bed based upon multi-beam depth measurements. In addition to flow velocity, ADCP measurements include river bathymetry information through the depth measurements acquired in individual 4 or 5 beams with a given oblique angle. Such sounding capability indicates that multi-beam ADCPs can be utilized as an efficient depth-sounder to be more capable than the conventional single-beam eco-sounders. The paper introduces the post-processing algorithms required to deal with raw ADCP bathymetry measurements including the following aspects: a) correcting the individual beam depths for tilt (pitch and roll); b) filtering outliers using SMART filters; d) transforming the corrected depths into geographical coordinates by UTM conversion; and, e) tag the beam detecting locations with the concurrent GPS information; f) spatial representation in a GIS package. The developed algorithms are applied for the ADCP bathymetric dataset acquired from Han-Cheon in Jeju Island to validate themselves applicability.

Comparative Evaluation of the Pollutant Load Estimation Method in the Water Quality Data Missing Intervals (수질자료 결측구간의 오염부하 추정기법 비교평가)

  • Cho, Beom-Jun;Cho, Hong-Yeon;Kahng, Sung-Hyun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.45-56
    • /
    • 2007
  • Direct estimation of the pollutant load(PL) should be carried out by the data filling in the missing intervals using an appropriate method because it is impossible in which the flow discharge(water quantity) or water quality(WQ) time-series data set have the missing intervals. In this study, the several methods estimating the water quality in the missing periods are suggested and the WQ and pollutants load change patterns are compared and evaluated based on the reproducible degree of the available data change patterns. The most appropriate method is finally suggested and the contribution factor deciding the influence degree and the PL characteristics of the river estuary is also suggested. Based on the PL estimation results using the several methods, the interpolation method considering the fluctuation of the available WQ data is shown to be most efficient. The PL patterns of the Han river estuary is classified as the discharge-dominated type. The data filling process is inevitable and the WQ estimation using the efficient and effective method should be carried out in order to estimate reasonable PL.

Estimation of Upstream Ungauged Watershed Streamflow using Downstream Discharge Data (하류 유량자료를 이용한 상류유역의 미계측 유출량 추정)

  • Jung, Young Hun;Jung, Chung Gil;Jung, Sung Won;Park, Jong Yoon;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.169-176
    • /
    • 2012
  • This study describes the estimation of upstream ungauged watershed streamflow using downstream discharge data. For downstream Dongchon (DC) and upstream Kumho (KH) water level stations in Kumho river basin ($2,087.9km^2$), three methods of Soil and Water Assessment Tool (SWAT) modeling, drainage-area ratio method and regional regression equation were evaluated. The SWAT was calibrated at DC with the determination coefficient ($R^2$) of 0.70 and validated at KH with $R^2$ of 0.60. The drainage-area ratio method showed $R^2$ of 0.93. For the regional regression, the watershed area, average slope, and stream length were used as variables. Using the derived equation at DC, the KH could estimate the flow with maximum 41.2 % error for the observed streamflow.

Variance components estimation in the presence of drift

  • Kim, Jaehee;Ogden, Todd
    • Communications for Statistical Applications and Methods
    • /
    • v.23 no.1
    • /
    • pp.33-45
    • /
    • 2016
  • Variance components should be estimated based on mean change when the mean of the observations drift gradually over time. Consistent estimators for the variance components are studied for a particular modeling situation with some underlying functions or drift. We propose a new variance estimator with Fourier estimation of variations. The consistency of the proposed estimator is proved asymptotically. The proposed procedures are studied and compared empirically with the variance estimators removing trends. The result shows that our variance estimator has a smaller mean square error and depends on drift patterns. We estimate and apply the variance to Nile River flow data and resting state fMRI data.

An Estimation of River bed Profile of the Stream System based on the Potential Energy Concept (位置에너지 槪念에 依한 水系의 河川縱斷 推定)

  • Ahn, Sang-Jin;Kang, Kwan-Won;Kim, Chang-Su
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.2
    • /
    • pp.76-88
    • /
    • 1982
  • The stream morphological characteristics of a basin have important influence upon the analysis of runoff. In this study, the laws of stream morphology-the law of average stream fall and the law of least rate of potential energy expenditure-which were derived based on the analogy of entropy in thermodynamics are introduced and their validity is analysised with the data taken from the topographic maps covering the whole Geum River system. The first law is the Law of Average Stream Fall which states that under the dynamic equilibrium condition the ratio of average fall between any two different order stream in the same river basin in unity. The second law is the law of least rate of energy expenditure which states that all natural streams are intended to choose their own course of flow such that the rate of potential energy loss per unit mass of water this course is a minimum. The parameters representing the morphological characteristics of 13 tributaries in the Geum River system such as stream bifurcation ratio and stream concavity were Computed from the Horton-Strahler's laws and are used to check the law of average stream fall. The result showed that the law of average stream fall agrees reasonably well with law of Horton-Strahler. Concavity of a river basin is shown to be the determinative factor to the formation of a stream system. Concavity of a river basin is shown to be the determinative factor to the formation of a stream system. Based on Horton's Law and the law of average stream fall, longitudinal stream profiles can be calculated.

  • PDF

Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems. (소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰)

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.3
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF

Evaluation of SWAT Model Applicability for Runoff Estimation in Nam River Dam Watershed (남강댐 상류 소유역의 유출량 추정을 위한 SWAT 모형의 적용성 평가)

  • Kim, Dong-Hyeon;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.4
    • /
    • pp.9-19
    • /
    • 2016
  • The objective of this study was to evaluate the applicability of SWAT (Soil and Water Assessment Tool) model for runoff estimation in the Nam river dam watershed. Input data for the SWAT model were established using spatial data (land use, soil, digital elevation map) and weather data. The SWAT model was calibrated and validated using observed runoff data from 2003 to 2014 for three stations (Sancheong, Shinan, Changchon) within the study watershed. The $R^2$ (Determination Coefficient), RMSE (Root Mean Square Error), NSE (Nash-Sutcliffe efficiency coefficient), and RMAE (Relative Mean Absolute Error) were used to evaluate the model performance. Parameters for runoff calibration were selected based on user's manual and references and trial and error method was applied for parameter calibration. Calibration results showed that annual mean runoff were within ${\pm}5%$ error compared to observed. $R^2$ were ranged 0.64 ~ 0.75, RMSE were 2.51 ~ 4.97 mm/day, NSE were 0.48 ~ 0.65, and RMAE were 0.34 ~ 0.63 mm/day for daily runoff, respectively. The runoff comparison for three stations showed that annual runoff was higher in Changchon especially summer and winter seasons. The flow exceedance graph showed that Sancheong and Shinan stations were similar while Changchon was higher in entire fraction.