• Title/Summary/Keyword: risk of radiation exposure

Search Result 222, Processing Time 0.024 seconds

Radiological Impact on Decommissioning Workers of Operating Multi-unit NPP (다수호기 원전 운영에 따른 원전 해체 작업자에 대한 방사선학적 영향)

  • Lee, Eun-hee;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.107-120
    • /
    • 2019
  • The decommissioning of one nuclear power plant in a multi-unit nuclear power plant (multi-unit NPP) site may pose radiation exposure risk to decommissioning workers. Thus, it is essentially required to evaluate the exposure dose of decommissioning workers of operating multi-unit NPPs nearby. The ENDOS program is a dose evaluation code developed by the Korea Atomic Energy Research Institute (KAERI). As two sub-programs of ENDOS, ENDOS-ATM to anticipate atmospheric transport and ENDOS-G to calculate exposure dose by gaseous radioactive effluents are used in this study. As a result, the annual maximum individual dose for decommissioning workers is estimated to be $2.31{\times}10^{-3}mSv{\cdot}y^{-1}$, which is insignificant compared with the effective dose limit of $1mSv{\cdot}y^{-1}$ for the public. Although it is revealed that the exposure dose of operating multi-unit NPPs does not result in a significant impact on decommissioning workers, closer examination of the effect of additional exposure due to actual demolition work is required. The calculation method of this study is expected to be utilized in the future for planned decommissioning projects in Korea. Because domestic NPPs are located in multi-unit sites, similar situations may occur.

Evaluation of the Usefulness for VMAT of multiple brain metastasis using jaw tracking (Jaw tracking을 이용한 다발성 뇌 전이의 용적세기조절회전치료에 대한 유용성 평가)

  • Kim, Tae Won;Yoo, Soon Mi;Jeon, Soo Dong;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.73-81
    • /
    • 2018
  • Purpose : The aims of this study were to compare and assess the effectiveness of Volumetric Modulated Arc Therapy(VMAT) using jaw tracking(JT) and fixed jaw(FJ) in radiation therapy of multiple brain metastasis. Methode and material : Among the patients with Multiple Brain Metastasis treated with jaw tracking, 10 patients with more than 6 tumors and with the size of radiation field $14{\times}14cm^2$ or more were included. Each Treatment plans with jaw tracking(JT) and fixed jaw(FJ) was established with Eclipse (Ver. 13.6 Varian, USA). Gamma Index (3 mm, 3 % confidence interval - 95 %) and maximum dose difference were measured with an electronic portal imaging device(EPID). The $D_{max}$ and $D_{mean}$ of Organ At Risk(OAR) were assessed and compared, and the Conformity Index(CI) and Homogeneity Index(HI) were evaluated. Result : Evaluating jaw tracking(JT) and fixed jaw(FJ) outcomes, in all cases, Gamma Index met the permissible standard of 3 mm, 3 % confidence intervals of 95 %. The maximum dose difference value from the areas with leaf end transmission was measured at a maximum of 98.4 % and an average of 43.6 % in clockwise(CW), and 67.9 % and 41.0 % for each in Counter-Clockwise(CCW). With jaw tracking, the maximum value of $D_{max}$ for each normal organ in OAR decreased in 15.36 %~74.59 % with the average value decreasing in 2.84 %~39.80 %. The maximum value of $D_{mean}$ in OAR decreased in 27.90 %~65.23 %, with the average value decreasing in 7.70 %~41.71 %. No change has been found in Conformity Index and Homogeneity Index values. Conclusion : When Jaw tracking is used in treating patients with multiple brain metastasis with VMAT, the unnecessary exposure due to leakage and transmission of radiation in unspecified areas was reduced, without affecting the dose distribution of the planning target volume(PTV), and the availability of radiation therapy with lower doses in normal organs is expected.

  • PDF

Induced Activity and Space Dose Distribution from Medical Linear Accelerator (의료용(醫療用) 선형가속기(線型加速器)에 의한 산난공간(散亂空間) 선량분포(線量分布)와 유도방사능(誘導放射能))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • It is important to measure and protect from the radiation space dose and induced activity at the high energy medical linear accelerator facilities. These are to consider the additional risk to patients undergoing treatment, machine operators and staff members. Measurements of the space dose distribution and induced radioactivity at the 18 MeV medical linear accelerator facility in the Yonsei Cancer Center. 1. Exposure space dose for 300 rads monitor doses of 18 MeV electron are measured as 50 mR at 1 meter from patients. 2. Exposure space dose for 300 rads monitor doses of 10 MV X-ray are detected as 350 mR at 1 meter from phantom. 3. Induced radioactivity by photonuclear reaction was measured as 0.65 mR/hr from collimater after 30 Gy(3,000 rads) irradiated. 4. Analyzing the decay curves and energy spectrum of induced radioactivity, detected a few materials to be activated by photoneutron reaction, $^{65}Cu({\gamma}{\cdot}n)\;^{64}Cu,\;^{186}W({\gamma}{\cdot}n)\;^{185}W,\;^{181}Ta({\gamma}{\cdot}n)\;^{180}Ta,\;^{199}Au({\gamma}{\cdot}n)\;^{198}Au$.

  • PDF

Quality Control Tests and Acceptance Criteria of Diagnostic Radiopharmaceuticals (진단용 방사성의약품의 품질관리시험 및 기준)

  • Park, Jun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Radiopharmaceuticals are drugs that contain radioisotopes and are used in the diagnosis, treatment, or investigation of diseases. Radiopharmaceuticals must be manufactured in compliance with good manufacturing practice regulations and subjected to quality control before they are administered to patients to ensure the safety of the drug. Radiopharmaceuticals for administration to humans need to be sterile and pyrogen-free. Hence, sterility tests and membrane filter integrity tests are carried out to confirm the asepticity of the finished drug product, and a bacterial endotoxin test conducted to assess contamination, if any, by pyrogens. The physical appearance and the absence of foreign insoluble substances should be confirmed by a visual inspection. The chemical purity, residual solvents, and pH should be evaluated because residual by-products and impurities in the finished product can be harmful to patients. The half-life, radiochemical purity, radionuclidic purity, and strength need to be assessed by analyzing the radiation emitted from radiopharmaceuticals to verify that the radioisotope contents are properly labeled on pharmaceuticals. Radiopharmaceuticals always carry the risk of radiation exposure. Therefore, the time taken for quality control tests should be minimized and care should be taken to prevent radiation exposure during handling. This review discusses the quality control procedures and acceptance criteria for a diagnostic radiopharmaceutical.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Survival Rate and Prognostic Factors of Esophageal Cancer in East Azerbaijan Province, North-west of Iran

  • Mirinezhad, Seyed Kazem;Somi, Mohammad Hossein;Jangjoo, Amir Ghasemi;Seyednezhad, Farshad;Dastgiri, Saeed;Mohammadzadeh, Mohammad;Naseri, Ali Reza;Nasiri, Behnam
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3451-3454
    • /
    • 2012
  • Background: Esophageal cancer in Iran is the sixth most common cancer and is particularly important in east Azerbaijan. The aim of this study was to calculate survival rates and define prognostic factors in esophageal cancer patients. Methods: In this study, all patients with esophageal cancer registered in the Radiation Therapy Center, during March 2006 to March 2011, were analyzed and followed up for vital status. Data were analyzed using the Kaplan-Meier method and the Cox proportional hazard models. Results: Out of 532 patients, survival information was available for 460, including 205 (44/ 5%) females and 255 (55/4%) males. The mean age was $65.8{\pm}12.2$, ranging from 29 to 90 years at the time of diagnosis. 1-, 3- and 5-year survival rates after diagnosis were 55%, 18% and 12%, respectively, with a median survival time of $13.2{\pm}.7$ (CI 95% =11.8-14.6) months. In the univariate analysis, age (P=0/001), education (P=0/001), smoking status (P= 0/001), surgery (P= 0/001), tumor differentiation (P= 0/003) and tumor stage (P= 0/001) were significant prognostic factors. Tumor morphology, sex, place of residence, tumor histology and tumor location did not show any significant effects on the survival rate. In multivariate analysis, age (P = 0/003), smoking (P= 0/01) and tumor stage (P= 0/001) were significant independent predictors of survival. Conclusion: In summary, prognosis of esophageal cancer in North West of Iran is poor. Therefore, reduction in exposure to risk factors and early detection should be emphasized to improve survival.

Risk of Breast Cancer among Young Women and Importance of Early Screening

  • Memon, Zahid Ali;Kanwal, Noureen;Sami, Munam;Larik, Parsa Azam;Farooq, Mohammad Zain
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7485-7489
    • /
    • 2015
  • Background: Breast cancer is the most common type of cancer in women throughout the world. However, in comparison with Western women, it presents relatively early in women of Asian ethnicity. Early menarche, late menopause, use of OCP's, family history of benign or malignant breast disease, exposure to radiation and BMI in the under-weight range are well known risk factors for the development of breast cancer in premenopausal women. Early detection with the use of breast self-examination (BSE) and breast cancer screening programs can lead to a reduction in the mortality rates due to breast cancer. The aim of our study was to assess the risk factors for breast cancer among young women and to emphasize the importance of early screening among them. Materials and Methods: We conducted a cross-sectional study among women aged 18 to 25 using a self-administered questionnaire. Data was collected over a period of 6 months from June to December, 2014. A total of 300 young women selected randomly from Dow Medical College and various departments of Karachi University successfully completed the survey. Results: Respondents were 18-25 years of age (mean age=21.5). Out of the 300 young females, 90 (30%) had at least one risk factor, 90 (30%) had two, 40 (13%) had three, 8 (2.7%) had four, 2 (0.7%) had five while one female was found to have six positive risk factors for breast cancer. Some 66 women (22%) experienced symptoms of breast cancer such as non-cyclical pain and lumps. While 222 women (74%) had never performed breast self-examination, 22 (7.3%) had had a breast examination done by a health professional while 32 (10.7%) had participated in breast screening programs. A total of 223 (74.3%) women considered breast cancer screening important for young women. Conclusions: The percentage of young women with risk factors for breast cancer was found to be alarmingly high. Therefore, screening for breast cancer should start at an early age especially in high risk groups. Awareness about breast self-examination should be emphasized. Moreover, screening programs should be started to ensure early detection and reduction of mortality rates caused by breast cancer also in young Pakistani females.

Chromosome Aberrations and Sister Chromatid Exchanges of Hospital Workers Exposed to Radiation (방사선취급 병원근무자들의 염색체이상 및 자매염색분체교환 빈도)

  • Cha, Ae-Ri;Kim, Mi-Sun;Hwang, In-Kyung;Lee, Su-Ill;Cho, Byung-Mann;Kim, Don-Kyoun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.616-627
    • /
    • 1998
  • In order to evaluate the cytogenetic hazard among hospital workers potentially exposed to low dose of radiation, the analysis of chromosome aberrations(CA) and sister chromatid exchanges(SCE) in lymphocytes were performed in 79 hospital workers and 79 non-exposed workers. The mean frequency of chromosomal exchange and deletion(respectively, $0.20\times10^{-2}/cell\;and\;0.39\times10^{-2}/cell$) in the exposed group were significantly higher than those$(0.07\times10^{-2}/cell\;and\;0.23\times10^{-2}/cell)$ in control group. The frequency of sister chromatid exchanges was 5.04/cell in the control vs. 6.57/cell in the exposed group. There were also significant differences in the mean frequencies of CA and SCE adjusted for age, sex, smoking, drinking between two groups. There were no evidence of significant increase of CA and SCE according to the department or duration of employment. But the frequency of cells having chromosome aberration was significantly higher in the exposed group than in the control group related to duration of employment. There was no dose-effect relationship between the cumulative doses and the frequency of CA and SCE. But in the case of last 1 yr cumulative dose, there were evidence of significant dose-dependant increase of chromosome type CA and percentage of cells with aberration. The result suggest that there is cytogenetic hazard in risk group like hospital workers handling low dose radiation. And the analysis CA and SCE are useful biological indicators for the exposure of low dose level of radiation.

  • PDF

From Radon and Thoron Measurements, Inhalation Dose Assessment to National Regulation and Radon Action Plan in Cameroon

  • Saidou;Shinji Tokonami;Masahiro Hosoda;Augustin Simo;Joseph Victor Hell;Olga German;Esmel Gislere Oscar Meless
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.237-245
    • /
    • 2022
  • Background: The current study reports measurements of activity concentrations of radon (220Rn) and thoron (220Rn) in dwellings, followed by inhalation dose assessment of the public, and then by the development of regulation and the national radon action plan (NRAP) in Cameroon. Materials and Methods: Radon, thoron, and thoron progeny measurements were carried out from 2014 to 2017 using radon-thoron discriminative detectors (commercially RADUET) in 450 dwellings and thoron progeny monitors in 350 dwellings. From 2019 to 2020, radon track detectors (commercially RADTRAK) were deployed in 1,400 dwellings. It was found that activity concentrations of radon range in 1,850 houses from 10 to 2,620 Bq/㎥ with a geometric mean of 76 Bq/㎥. Results and Discussion: Activity concentrations of thoron range from 20 to 700 Bq/㎥ with a geometric mean of 107 Bq/㎥. Thoron equilibrium factor ranges from 0.01 to 0.6, with an arithmetic mean of 0.09 that is higher than the default value of 0.02 given by UNSCEAR. On average, 49%, 9%, and 2% of all surveyed houses have radon concentrations above 100, 200, and 300 Bq/㎥, respectively. The average contribution of thoron to the inhalation dose due to radon and thoron exposure is about 40%. Thus, thoron cannot be neglected in dose assessment to avoid biased results in radio-epidemiological studies. Only radon was considered in the drafted regulation and in the NRAP adopted in October 2020. Reference levels of 300 Bq/㎥ and 1,000 Bq/㎥ were recommended for dwellings and workplaces. Conclusion: Priority actions for the coming years include the following: radon risk mapping, promotion of a protection policy against radon in buildings, integration of the radon prevention and mitigation into the training of construction specialists, mitigation of dwellings and workplaces with high radon levels, increased public awareness of the health risks associated with radon, and development of programs on the scientific and technical aspects.

Draft List and Relative Importance of Principal Processes in the Geosphere to be Considered for the Radiological Safety Assessment of the Domestic Geological Disposal Facility through Analyzing FEPs for KBS-3 Type Disposal Repository of High-level Radioactive Waste(HLW) (KBS-3 방식 고준위방폐물 심층처분장 FEP 분석을 통한 국내 사용후핵연료 심층처분시설 방사선학적 안전성 평가용 지권영역 주요 프로세스 항목 및 상대적 중요도 도출)

  • Sukhoon Kim;Donghyun Lee;Dong-Keuk Park
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.33-44
    • /
    • 2023
  • The deep geological repository of high-level radioactive waste shall be designed to meet the safety objective set in the form of radiation dose or corresponding risk to protect human and the environment from radiation exposure. Engineering feasibility and conformity with the safety objective of the facility conceptual design can be demonstrated by comparing the assessment result using the computational model for scenario(s) describing the radionuclide release and transport from repository to biosphere system. In this study, as the preliminary study for developing the high-level radioactive waste disposal facility in Korea, we reviewed and analyzed the entire list of FEPs and how to handle each FEP from a general point of view, which are selected for the geosphere region in the radiological safety assessment performed for the license application of the KBS-3 type deep geological repository in Finland and Sweden. In Finland, five FEPs (i.e., stress redistribution, creep, stress redistribution, erosion and sedimentation in fractures, methane hydrate formation, and salt exclusion) were excluded or ignored in the radionuclide release and transport assessment. And, in Sweden, six FEPs (i.e., creep, surface weathering and erosion, erosion/sedimentation in fractures, methane hydrate formation, radiation effects (rock and grout), and earth current) were not considered for all time frames and earthquake out of a total of 25 FEPs for the geosphere. Based on these results, an FEP list (draft) for the geosphere was derived, and the relative importance of each item was evaluated for conducting the radiological safety assessment of the domestic deep geological disposal facility. Since most of information on the disposal facility in Korea has not been determined as of now, it is judged that all FEP items presented in Table 3 should be considered for the radiological safety assessment, and the relative importance derived from this study can be used in determining whether to apply each item in the future.