• Title/Summary/Keyword: risk management standard

Search Result 462, Processing Time 0.029 seconds

APPLICATION OF CONTRACTORS' RISK PREFERENCE ON THE EVALUATION OF THE PHILIPPINE GOVERNMENT STANDARD CONTRACT

  • Visuth Chovichien;Joel Cesarius V. Reyes
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.144-152
    • /
    • 2009
  • Construction contracts involve the allocation or distribution of the risks inherent to a construction project between or among contracting parties. However, it has been a common practice that only one party drafts the contract due to practical reasons and particular policies of various organizations. Interviews were conducted on some local contractors to gain their meaningful insights and standpoints on the allocation of each risk. These results were compared with the actual risk allocation using the Philippine government standard contract and risk principles from the literature to determine if their considered opinions provide a plausible alternative. A sample application of this evaluation is presented for construction-related risks and risk allocation recommendations are provided in the end.

  • PDF

Estimating Relative Risk Level of Construction Work (건설공사 상대적 위험도 산정)

  • Son, Ki-Sang;Yang, Hak-Soo;Gal, Won-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.53-59
    • /
    • 2006
  • Standard safety management costs can not be applied to each site with same rate, it is very difficult, because it depends on the experience, work method, work kind, work progress schedule, and hazard level of each construction company. Therefore, this study is to find out hazard level of each work kinds through questionnaire and interview and investigate analyze the status which standard safety management costs have been used. Also, this study is to show reasonable rates of standard safety management costs in construction industry and to set up countermeasures against those problem after reviewing its status in korea with in Japan and Europe. The domestic system of standard safety management costs is not considered in the foreign country, while only related subjective items have been investigated and evaluated for this study. This study is to investigate eleven project kinds of domestic system, first, and to investigate eleven items of apartment bldg, office, civil work such as bridge, tunnel, dam, plant etc, secondly. Additionally, three items of gymnasium, railway, particular steel tower are investigated in this study. Also this study is to investigate and analyze performed costs of presently processing worker finished work so that it shows a new reasonable rate against standard safety management costs in construction industry, in order to make basial data and material to be systemized.

A Study on Intellgence Emergency Guide Line System (지능형 피난유도선 시스템에 대한 연구)

  • Park, Yong-Gyu;Kim, Suk-Eun;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.04a
    • /
    • pp.107-116
    • /
    • 2010
  • Government and company are unfolding greenhouse gas reduction activity to prevent the effects of global warming. Also, verification business through greenhouse gas inventory construction is spreaded variously. Greenhouse gas verification proceeds by document examination, risk analysis, field survey. Document investigates emission information, calculation standard, emission report, data management system. And through risk assessment result, establish field verification plan. Through study on risk assessment of greenhouse gas inventory verification, wish to reduce risk of verification.

  • PDF

Deriving Ecological Protective Concentration of Cadmium for Korean Soil Environment

  • Lee, Woo-Mi;Nam, Sun-Hwa;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.241-246
    • /
    • 2013
  • For effective and efficient environmental management, developed countries, such as the Netherlands, UK, Australia, Canada, and United States apply ecological risk assessment, and they have an autonomous risk assessment methodology to protect native receptors. In this study, soil ecological protective concentration (EPC) of cadmium in Korea was derived using Korean ecological risk assessment methodology. The soil EPC of cadmium was calculated using probabilistic ecological risk assessment based on species sensitivity distribution. The soil EPC was calculated according to land use for residential/agricultural and industrial/commercial purposes. The chronic soil EPCs for residential/agricultural and industrial/commercial lands were derived to be 1.58 and 9.60 mg/kg, respectively. These values were similar to soil EPC of European Commission, the Netherlands, UK, and Canada. However, these values were lower than the established Korean soil standard, because the current soil standard was based on human risk. Therefore, the impact on an ecosystem when establishing environmental standard should be considered.

A Study on the Management Criteria of Chemiclas Impurities for Drinking Water Treatment by Risk Assessment (건강위해성 평가에 의한 정수용 수처리제의 불순물 관리 기준 설정 방법에 관한 연구)

  • Chung, Yong;Beck, Young-seog;Kwon, Dong-sik;Lee, Ki-gong;Kang, Hyeong-seok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.432-436
    • /
    • 2004
  • The principle and methodology of risk assessment was applied to establish the quality standard of potential impurities of drinking water treatment chemicals. The impurities(arsenic, lead, cadmium, chromium, mercury, etc.) are regulated as the contained quantity of chemicals in Korea while they are regulated as the quality standard with the idea of 10% of the national safety drinking water standard in U.S.A(NSF) and Japan(JWWA). According to risk assessment of the current standard implemented in Korea, the excess cancer risk of arsenic and lead were determined in around $10^{-5}$ and the hazard quotient(HQ) of cadmium and chromium were below $10^{-2}$, respectively. And the standard concentration of the impurities are regulated as much as 2%~6% of the national drinking water quality standard. The values are more enforced rather than the standards in U.S.A(NSF) and Japan(JWWA) regulating the concentration of impurities the 10% of the national drinking water quality standard. We conclude that the impurities standard of drinking water treatment chemicals should be reconsidered comprehensively concerning the national safety drinking water quality standard and risk assessment.

A study on Standard Safety Operation Evaluation Method for Improving Safety Activity (안전활동 개선을 위한 표준 안전작업 평가기법 설계)

  • Yang, Kwang-Mo;Yang, Hyun-Hoo;Kang, Yun-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.39-47
    • /
    • 2007
  • An industrial injury prevention has a basis on fundamental spirit of human respect rather than only injury prevention in company. The employer should recognize employee as a core part of an industrial management and use as a starting point of safety and health management rather than means of production. There are many reason for unsafety action without safety operation. The reason is no standard safety operation in company or the workers never get a enough education. Standard safety operation is prepared by paper for accurate directions and orders and operators must read the paper to prevent an error of action. Also an essential particular is safety of equipment and machine must be assumed to establish standard safety operation then safety of operations will be possible.

Reliability Management of Mechanical Ventilator in Intensive Care Unit Using FMEA Based on ISO14971 (ISO14971 기반 FMEA를 이용한 중환자실내 인공호흡기 신뢰성 관리)

  • Hyun Joon, Kim;Won Kyu, Kim;Tae Jong, Kim;Gee Young, Suh
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.19-24
    • /
    • 2023
  • Due to the spread of COVID-19, many patients with severe respiratory diseases have occurred worldwide, and accordingly, the use of mechanical ventilators has exploded. However, hospitals do not have systematic risk management, and the Medical Device Regulation also provides medical device risk management standards for manufacturers, but does not apply to devices in use. In this paper, we applied the Failure Mode Effects Analysis (FMEA) risk analysis technique based on the International Standard ISO 14971 (Medical Devices-Application of risk management to medical devices) for 85 mechanical ventilators of a specific model in use in hospitals. Failure modes and effects of each parts were investigated, and risk priority was derived through multiplication of each score by preparing criteria for severity, occurrence, and detection for each failure mode. As a result, it was confirmed that the microprocessor-based Patient Unit/Monitoring board in charge of monitoring scored the highest score with 36 points, and that reliability management is possible through systematic risk management according to priority.

A Study on Priority Factor Analysis of Standard Method for Risk Measurement (위험성 측정을 위한 표준안전작업 중점사항 분석에 관한 연구)

  • Yang, Kwang-Mo;Kim, Min-Jun;Cho, Jung-Hyun;Park, Jae-Hyun
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.04a
    • /
    • pp.27-33
    • /
    • 2007
  • There are many reason for unsafety action without safety operation. The reason is no standard safety operation in company or the workers never get a enough education. Standard safety operation is prepared by paper for accurate directions and orders and operators must read the paper to prevent an error of action. Also an essential particular is safety of equipment and machine must be assumed to establish standard safety operation then safety of operations will be possible.

  • PDF

Technical Review on the QRA of Railway Safety Facilities (철도 안전 설비의 정량적 위험평가 기술)

  • Choi, Kwon-Hee;Kim, You-Ho;Lee, Jong-Woo;Song, Joong-Ho;Song, Kwang-Yeol
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2011
  • The overall goal of a safety based railroad system is either to eliminate hazards in designing or to minimize the possibility of it. In order to indicate system safety or low risk although it may not be possible to achieve zero risk conditions, first, it shall ensure that any disasters would occur due to system operation because the prescribed specifications are properly fulfilled and there are no failures of any kind. Second, the risk of faults or failures leading to a mishap must be eliminated or minimized by using fault-tolerance or fail-safe procedures. This paper will attempt to summarize the personal and social risk criterion at widely scattered points, presently used as a safety approach in all over EU, in order to establish the step by step procedures of the detailed standard for railway facilities. In addition, we present the new safety analysis method using the SIL-based evaluation standard and the Reachability Graph of the Petri Net.

A Study on the general direction of Fire-Fighting Safety management in high-rise buildings (초고층 건축물 소방안전관리의 기본방향에 관한 연구)

  • Choi, Man-Chul;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.