• Title/Summary/Keyword: risk

Search Result 31,988, Processing Time 0.074 seconds

Nutritional Risks Analysis Based on the Food Intake Frequency and Health-related Behaviors of the Older Residents (50 Years and Over) in Andong Area (1) (안동주변 농촌지역 50세 이상 주민의 식품섭취빈도 및 건강행위에 따른 영양위험 분석 (1))

  • Lee, Hye-Sang;Kwun, In-Sook;Kwon, Chong-Suk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.8
    • /
    • pp.998-1008
    • /
    • 2008
  • This study aimed to assess the nutritional status and the nutritional risks based on the food intake frequency and health-related behaviors of middle-aged and elderly people living in Andong area. Interviews were conducted with 1,384 subjects (532 males, 852 females) aged 50 years and over. Nutrient intakes, food intake frequency, and health-related behaviors including smoking, drinking, and exercise were investigated. The average energy intakes were 1410.5 kcal for males and 1279.2 kcal for females, and the percentages of the subjects consuming below the estimated energy requirement (EER) were 92.5% and 88.4%, respectively. The least consumed nutrients compared to the estimated average requirement (EAR) were riboflavin (92.5% for males, 89.6% for females), folic acid (89.7%, 88.5%), and calcium (78.9%, 85.8%), in order. According to the food intake frequency survey, the intakes of meat, fish and vegetable (except kimchi) were very poor, and this low intakes of meat and fish showed as poor status of protein, niacin, vitamin $B_6$, and zinc intakes. Health-related behaviors data showed that the ratio of cigarette smokers, especially male, was higher, while the ratio of the person exercising regularly was lower than that of the nationwide statistics, respectively. Cigarette smoking and drinking were not significantly related to the poor nutrition intake, while regular exercise positively influenced nutrient intakes in female subjects. These results showed that the nutritional status of the subjects was likely to be severely deficient and the low intakes of meat and fish to be highly related to the increase of nutritional risk. Therefore, in order to prevent the occurrence of the secondary disease related to the food intake and health-related behaviors of the subjects, the proper educational program on balanced dietary intake and the correction of health-related behaviors should be developed and applied to this area.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Actual Conditions and Perception of Safety Accidents by School Foodservice Employees in Chungbuk (충북지역 학교급식 조리종사원의 안전사고 실태 및 인식)

  • Cho, Hyun A;Lee, Young Eun;Park, Eun Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1594-1606
    • /
    • 2014
  • The purpose of this study was to examine safety accidents related to school foodservice, working and operating environments of school foodservice, status and awareness of safety education, educational needs, and information on qualitative improvement of school foodservice. The subjects in this study were 234 cooks in charge of cooking at elementary and secondary schools in Chungbuk. A survey was conducted from July 30 to August 8, 2012, and among 202 questionnaires gathered, 194 completed questionnaires were analyzed. Statistical analyses were performed on data utilizing the SPSS version 19.0. The main results of this study were as follows: 44.3% of workers experienced safety accidents. The most frequent safety accident was 'once' (60.5%), and most safety accidents took place between June and August (31.4%). The time at which most safety accidents happened was between 8 and 11 am. Most safety accidents happened during cooking (52.3%) and while using a soup pot or frying pot (52.4%). The most common accidents were 'burns', 'wrist and arm pain', and 'slips and falls'. Respondents who experienced safety accidents replied that 57.6% of employees dealt with injuries at their own expense, and only 35.3% utilized industrial accident insurance. In terms of the operating environment, the score for 'offering information and application' was highest (3.76 points), whereas that for 'security of budget' was lowest (1.77 points). As for accident education, employees received safety education approximately 3.45 times and 5.10 hours per year. Improving the working environment of school foodservice cooks requires administrative and financial support. Furthermore, educational materials and guidelines based on the working environment and safety accident status of school foodservice cooks are required in order to minimize potential risk factors and control safety accidents in school foodservice.

Usefulness of Tuberculin Skin Test by Tuberculin PPD RT23 2 TU (Tuberculin PPD RT23 2 TU를 이용한 투베르쿨린 피부반응 검사의 의의)

  • Yang, Jong-Wuk;Jeon, Man-Jo;Kim, Sung-Jung;Lee, Hyang-Lim;Lee, Seung-Jun;Lee, Myoung-Goo;Kim, Dong-Gyu;Park, Myoung-Jae;Kang, Min-Jong;Hyoen, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.401-408
    • /
    • 2002
  • Background : Tuberculin skin test is a method to examine M. tuberculosis infection and has been used all over the world. But various factors make it difficult to understand testing results. In 2000, the American Thoracic Society recommended that skin test results should be decided by considering risk factors of the tested. In Korea, high tuberculosis infection rate and BCG vaccination rate make it difficult to differentiate current infection, past infection, and no infection by the skin test. This study was attempted to examine a negative predictive value of the skin test to understand how the skin test acts on deciding administration of anti-tuberculosis drug. Methods : From Mar. 1 to Jul. 31 in 2001, the test was performed for patients hospitalized in Department of Internal Medicine, Hallym University College of Medicine, Chunchon, Korea by administering Tuberculin PPD RT23 2 TU (0.1 ml)to them that has been currently used in Korea based on Mantoux method. They were decided to be infected with tuberculosis bacilli by following diagnostic standard: 1) tuberculosis bacilli was cultured in sputum by microbiological diagnostic standard or Acid-fast bacilli was proven on a microscopic examination or 2) tuberculosis bacilli was not proven in the aforesaid microbiological test by clinical diagnostic standard, while there was opinion or symptom suitable for tuberculosis by radiographic or histological standard so the doctor decided to apply the tuberculosis treatment. Results : In this study, total 210 patients except 20 patients (8.7%) among 230 hospitalized patients were evaluated. Their average age was 60±16.8 years, and male-female rate was 1.28 : 1 (male: 118, female: 92). Number of patient, who was diagnosed and decided as tuberculosis, was 53(25.2%). Pulmonary tuberculosis was found in 45 patients (84.9%); 22 patients were decided to be positive in the Acid-fast bacilli smear test by microbiological examination (culture positive: 13, culture negative: 9), and 23 patients were decided to be tuberculosis patients by clinical diagnosis standard. Tuberculosis pleuritis was found in 8 patients (15.1%); 4 patients were diagnosed and decided by histological standard, and 4 patients were decided and treated by clinical standard. In differentiating patients into 'Negative' and 'Positive' by the skin test standard of the American Thoracic Society, negative predictive value 92.3%, positive predictive value 47.3%, sensitivity and specificity were 83%, 68.8%, respectively. Conclusion : In hospitalized respiratory patients, there was high negative predictive vlaue 92.3% by tuberculin skin test, therefore skin test would be a important factor for deciding administration of anti-tuberculosis drug on negative skin test patient.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Epidemiological Studies of Clonorchiasis - II. Current Status and Natural Transition of the Endemicity of Clonorchis sinensis in Goyang Gun, a Low Endemic Area in Korea (간흡충증(肝吸虫症) 역학(疫學) - II. 저도유행지(低度流行地) 고양지방(高陽地方)에 있어서의 간흡충감염(肝吸虫感染)의 현황(現況)과 자연추이(自然推移))

  • Kim, D.C.;Lee, O.Y.;Lee, J.S.;Ahn, J.S.;Chang, Y.M.;Son, S.C.;See, S.H.
    • Journal of agricultural medicine and community health
    • /
    • v.8 no.1
    • /
    • pp.66-80
    • /
    • 1983
  • As a part of the epidemiological studies of clonorchiasis in Korea, this study was conducted to evaluate the current endemicity and the natural transition of the Clonorchis infection in Goyang Gun a low endemic area in recent years, prior to the introduction of praziquantel which will eventually influence to the status of the prevalence. The data obtained in this study in 1983 were evaluated for natural transition of the infection in comparison with those obtained 16 years ago in 1967 by the author (Kim, 1974). The areas of investigation, villages and schools surveyed, methods and techniques used in this study were the same as in 1967, except for the contents of the questionnaire for raw freshwater fish consumption by the local inhabitants. 1) The current prevalence rate of Clonorchis infection among the inhabitants was 7.5% on the average out of a total of 479 persons examined. The prevalence rate was 9.0% in the riverside area and 4.2% in the inland area. Among the schoolchildren, the prevalence rate was 1.1% out of a total of 1 319 examined. By area, it was 1.4% in the riverside area and 0.7% in the inland area. By sex, the prevalence rate was 13.3% in the male and 1.3% in the female in the inhabitants and no difference was seen in the schoolchildren. 2) In the natural transition of the infection, the prevalence rate in the inhabitants has decreased from 22.5% in 1967 to 7.5% in 1983, and in the schoolchildren, from 9.5% in 1967 to 1.1% in 1983. The reduction rate was higher in the riverside area than in the inland area. 3) In the prevalence rate by age, 1.2% was seen in the 10-14 age group and gradually increased to 8.1% in the 30-39 age group and reached peak 18.1% in the 40-49 age group. By sex, in the male, the prevalence rates have increased to 31.9% and 33.3% in the 40-49 and 50-59 age groups, respectively and decreased thereafter. In the female, the prevalence rate less than 5% was seen only in between the 10-14 and 30-39 age groups. 4) In the natural transition of the prevalence rate by age, sharp decrease was seen in the male from around 50% in 1967 between 15-19 and 30-39 age groups. The generation over 40s showed less decrease. In the female, the prevalence rate has decreased from 13% in 1967 to 5% in 1983 in the middle age groups and dropped to 0% in the rest of the age groups. 5) The intensity of the infection among clonorchiasis cases by mean EPmg (number of eggs per mg feces) value was 1.4. In the inhabitants, the value was 2.0 in the riverside area and 0.4 in the inland area. While in the schoolchildren, the value was 0.2 in both riverside and inland areas. 6) In the transition of the intensity of the infection, EPmg among the inhabitants has decreased from 3.9 in 1967 to 2.0 in 1983 in the riverside area, and from 2.9 to 0.4 in the inland area. In the schoolchildren, the reduction was similar in both riverside and inland areas resulting from 1.0-1.1 in 1967 to 0.2 in 1983. 7) In the intensity of the infection by age, EPmg 3.4 was peak at the 40-49 age group and 0.2-1.0 was seen in the rest of the age groups. The mean value was 1.5 in the male and 0.6 in the female. 8) In the natural transition of the intensity of the infection, the EPmg has decreased from 2.7 in 1967 to 1.4 in 1983. By age, reduction was seen in all of the age groups, particularly in the young and the old age groups of 50s and over, except in the 40-49 age group in which reverse phenomenon was seen. By sex, it has decreased from 3.5 in 1967 to 1.5 in 1983 in the male and from 1.0 to 0.6 in the female. 9) In the distribution of the clonorchiasis cases by the range of EPmg value, 70.3% of the cases were placed in the range of 0.1-0.9 as the most and 16.2% in 1.0-4.9 as the next. With such figures, those included in the range less than 0.9 as light infection were 78.4% and under 5.0-9.9 up to moderate infection 99.3% of the cases were covered. The cases were distributed up to 20.0-39.9 in the male and to 1.0-4.9 in the female. 10) In the transition of the distribution of the clonorchiasis cases by EPmg, the highest intensity reached up to 60.0-79.9 in 1967 and to 20.0-39.9 in 1983. In the range of light infection, under 0.1-0.9, the distribution in rate was 64.5% in 1967 and 78.4% in 1983. Up to the range of moderate infection, under 5.0-9.9, 91.7% in 1967 and 97.3% in 1983 were seen respectively. 11) In a survey for raw freshwater fish consumption among the local inhabitants,78.3 of the clonorchiasis cases interviewed admitted their experience of the raw consumption. However, those who practised in the past two years were 34.8% 55.6% of those who have such experience in the past professed that they did not practise raw freshwater fish consumption in the past two years. 12) The major cause of the reduction of the raw freshwater fish consumption among the inhabitants were the wide spread water pollution in the locality. The most common reason professed for stopping raw freshwater fish consumption among the inhabitants was the risk of the fluke infection. 13) In animal survey, 3.1% of dogs were found infected with Clonorchis, decreasing from 21.6% in 1967. 14) The distribution of the first intermediate host, Parafossarulus manchouricus has greatly diminished in this locality and found only in two localized ponds. No Clonorchis infection was found from the snails examined. 15) The second intermediate freshwater fish host has been further limited by extended water pollution. No susceptible fish host could be examined. 16) In conclusion, the endemicity of Clonorchis infection in Croyang Gun, low endemic area, has significantly decreased during the past 16 years. The major cause of the regressive transition of the infection was the water pollution of the freshwater system of this locality. This has upset the ecosystems of the intermediate host of Clonorchis sinensis in many areas of waterbodies and further discouraged to a significant extent the local inhabitants from raw freshwater fish consumption.

  • PDF

Effect of the Suicide Prevention Program to the Impulsive Psychology of the Elementary School Student (자살예방 프로그램이 초등학교 충동심리에 미치는 영향)

  • Kang, Soo Jin;Kang, Ho Jung;Cho, Won Cheol;Lee, Tae Shik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.1
    • /
    • pp.65-72
    • /
    • 2013
  • In this study, the early suicide prevention program was applied to the elementary school students and compared the prior & post effect of the program, and verified the status of psychology change like emotional status, or temptation to take a suicide, and presented the possibility as a suicide prevention program. The period of adolescence is the very unstable period in the process of growth being cognitively immature, emotionally impulsive period. It is the period emotionally unstable and unpredictable possible to select the method of suicide as an extreme method to escape the reality, or impulsive problem solving against small conflict or dispute situation. Many stress of the student such as recent nuclear family, expectation of parents to their children, education problem, socio-environmental elements, individual psychological factor lead students to the extreme activity of suicide in recent days. In this study, the scope of stress experienced in the elementary school as well as idea and degree of temptation regarding suicide by the suicide prevention program were identified, and through prevention program such as meditation training, breath training and through experience of anger control, emotion-expression, self overcome and establish positive self-identity and make understanding Self-control, Self-esteem & preciousness of life based on which the effect to suicide prevention was analyzed. The study was made targeting 51 students of 2 classes of 6th grade of elementary school of Goyang-si and processed 30 minutes every morning focused on through experience & activity of the principle & method of brain science. The data was collected for 20 times before starting morning class by using Suicide Probability Scale(herein SPS-A) designed to predict effectively suicide Probability, suicide risk prediction scale, surveyed by 7 areas such as Positive outlook, Within the family closeness, Impulsivity, Interpersonal hostility, Hopelessness, Hopelessness syndrome, suicide accident. Analytical methods and validation was used the Wilcoxon's signed rank test using SPSS Program. Though the process of program in short period, but there was a effective and positive results in the 7 areas in the average comparison. But in the t-test result, there was a different outcome. It indicated changes in the 3 questionnaires (No.7, No.14, No.19) out of 31 SPS-A questionnaires, and there was a no change to the rest item. It also indicated more changes of the students in the class A than class B. And in case of the class A students, psychological changes were verified in the areas of Hopelessness syndrome, suicide accident among 7 areas after the program was processed. Through this study, it could be verified that different results could be derived depending on the Student tendency, program professional(teacher in charge, processing lecturer). The suicide prevention program presented in this article can be a help in learning and suicide prevention with consistent systematization, activation through emotion and impulse control based on emotional stress relief and positive self-identity recovery, stabilization of brain waves, and let the short period program not to be died out but to be continued connecting from childhood to adolescence capable to make surrounding environment for spiritual, physical healthy growth for which this could be an effective program for suicide prevention of the social problem.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF