• Title/Summary/Keyword: ripple reduction

Search Result 375, Processing Time 0.028 seconds

Online Turn-Off Angle Contro1 for Performance Optimization of the Switched Reluctance Motor (온라인 턴 오프각제어를 통한 SRM의 성능최적화)

  • Jeong, Byeong-Ho;Choi, Youn-Ok;Lee, Kang-Yeon;Cho, Geum-Bae;Chung, Soo-Bok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • This paper represent improved on-line turn off angle control schemes for switched reluctance motors based on current control. For the purpose of finding the optimal commutation switching angle point with improved controller, it is utilized turn on and turn off position calculation with inductance vs. current vs. not linkage analysis method. The goal of proposed paper is the maximization of the energy conversion per stroke and torque ripple reduction and obtaining approximately flat-topped current waveform. The proposed control scheme is demonstrated simulation and on a prototype experimental system.

Dead time Compensation of Single-phase Grid-connected Inverter Using SOGI (SOGI를 이용한 단상 계통연계형 인버터의 데드타임 보상)

  • Seong, Ui-Seok;Lee, Jae-Suk;Hwang, Seon-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.166-174
    • /
    • 2017
  • This study proposes a compensation method for the dead-time effects on a single-phase grid-connected inverter. Dead time should be considered in the pulse-width modulation gating signals to prevent the simultaneous conduction of switching devices, considering that a switching device has a finite switching time. Consequently, the output current of the grid-connected inverter contains odd-numbered harmonics because of the dead time and the nonlinear characteristics of the switching devices. The effects of dead time on output voltage and current are analyzed in this study. A new compensation algorithm based on second-order generalized integrator is also proposed to reduce the dead-time effect. Simulation and experimental results validate the effectiveness of the proposed compensation algorithm.

Torque Ripple Reduction Algorithm of PMSM at High Speed Operation (PMSM 고속운전 시 토크리플 저감 알고리즘)

  • Kim, Jong-Hyun;Cho, Kwan-Yuhl;Kim, Hag-Wone;Nam, Myung-Joon;Lim, Byung-Kuk;Jin, Jong-Hag;Lee, Jong-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.118-119
    • /
    • 2014
  • 왜곡된 역기전력을 갖는 매입형 영구자석동기전동기를 정현파 전류로 제어할 경우 역기전력의 왜곡으로 인해 발생하는 토크리플은 전동기의 진동, 소음, 효율 저하의 요인이 된다. 저속운전의 경우 토크리플을 상쇄할 수 있는 고조파전류를 인가하여 전류제어에 의해 토크리플을 줄일 수 있다. 그러나 고조파 전류제어에 의한 토크리플 저감은 전류제어기의 대역폭에 의해 전류제어 특성이 좌우되므로 고조파 보상전류의 주파수가 높은 경우 적절한 보상이 되지 않는다. 본 논문에서는 전동기의 고속운전 시 고조파 전류에 해당되는 고조파 전압을 보상함으로써 역기전력에 의한 토크리플을 저감한다. 제안된 토크리플 저감 알고리즘은 시뮬레이션을 통해 검증한다.

  • PDF

Fault Tolerance Operation and Characteristics Analysis of Asymmetric Six-phase Permanent Magnet Synchronous Motor According to Switch Open (비대칭 6상 영구자석 동기 전동기의 스위치 개방에 따른 특성 분석 및 고장허용운전)

  • Jun, So-Young;Hwang, Seon-Hwan;Park, Jong-Won
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1003-1008
    • /
    • 2022
  • This paper proposes a method related to fault tolerance operation and characteristic analysis of asymmetric 6-phase permanent magnet synchronous motor. In general, motor drive systems with multi-phase structures can be continuously operated despite a reduction of power and speed by using a phase changeover or control techniques according to the failures. As a result, it is widely used in industrial fields such as aviation and defense, which require high efficiency and high reliability. In this paper, the second order ripple of the electrical fundamental freuqnecy occurs in the dq-axis currents of the synchronous coordinate system through mathematical analysis according to the switch open of the dual 3-phase inverter. Therefore, the fault tolerant operation method is presented by applying the fault detection method with a constant cycle for continuous operations. The effectiveness of the proposed fault tolerance operation method is verified through the several experiments.

Capacitor Failure Detection Technique for Microgrid Power Converter (마이크로그리드 전력변환장치용 커패시터 고장 검출 기법)

  • Woo-Hyun Lee;Gyang-Cheol Song;Jun-Jae An;Seong-Mi Park;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1117-1125
    • /
    • 2023
  • The DC part of the DC microgrid power conversion system uses capacitors for buffers of charge and discharge energy for smoothing voltage and plays important roles such as high frequency component absorption, power balancing, and voltage ripple reduction. The capacitor uses an aluminum electrolytic capacitor, which has advantages of capacity, low price, and relatively fast charging/discharging characteristics. Aluminum electrolytic capacitors(AEC) have previous advantages, but over time, the capacity of the capacitors decreases due to deterioration and an increase in internal temperature, resulting in a decrease in use efficiency or an accident such as steam extraction due to electrolyte evaporation. It is necessary to take measures to prevent accidents because the failure diagnosis and detection of such capacitors are a very important part of the long-term operation, safety of use, and reliability of the power conversion system because the failure of the capacitor leads to not only a single problem but also a short circuit accident of the power conversion system.

Design of a CCM/DCM dual mode DC-DC Buck Converter with Capacitor Multiplier (커패시터 멀티플라이어를 갖는 CCM/DCM 이중모드 DC-DC 벅 컨버터의 설계)

  • Choi, Jin-Woong;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.21-26
    • /
    • 2016
  • This paper presents a step-down DC-DC buck converter with a CCM/DCM dual-mode function for the internal power stage of portable electronic device. The proposed converter that is operated with a high frequency of 1 MHz consists of a power stage and a control block. The power stage has a power MOS transistor, inductor, capacitor, and feedback resistors for the control loop. The control part has a pulse width modulation (PWM) block, error amplifier, ramp generator, and oscillator. In this paper, an external capacitor for compensation has been replaced with a multiplier equivalent CMOS circuit for area reduction of integrated circuits. In addition, the circuit includes protection block, such as over voltage protection (OVP), under voltage lock out (UVLO), and thermal shutdown (TSD) block. The proposed circuit was designed and verified using a $0.18{\mu}m$ CMOS process parameter by Cadence Spectra circuit design program. The SPICE simulation results showed a peak efficiency of 94.8 %, a ripple voltage of 3.29 mV ripple, and a 1.8 V output voltage with supply voltages ranging from 2.7 to 3.3 V.

Housing Market Participants' Decision Process and The Dynamics of Ripple Effect on Korean Housing Market - Focusing on The Cause of Housing Market Stagnation and Housing Policies After 2008 Global Financial Crisis - (국내 주택시장 참여자의 거래의사 결정과정 및 시장 파급효과의 동태적 분석 - 금융위기 이후의 주택시장 침체원인 및 주택정책을 중심으로 -)

  • Hyun, Hosang;Lee, Hyun-Soo;Park, Moonseo;Hwang, Sungjoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.5
    • /
    • pp.147-159
    • /
    • 2014
  • After 2008 global financial crisis, Korean housing market has experienced stagnation. So it caused housing market problems like housing price reduction, rising rent cost and so on. For housing market normalization government announced policies but Korean housing market didn't recover from stagnation. So, to understand why Korean housing market couldn't overcome the recession and why the policies didn't be effective, this research analyzed housing market participants (home owner, housing demand) based on the law of supply and demand and the psychological effect on their transaction intention based on behavioral economics(behavioral finance). Based on the analysis this research tested the effectiveness of announced policies using System Dynamics. The result showed that the amount of transaction and mortgage loan was influenced by the length of time to draft policies.

The Analysis of Skewed Armature Effect for Reduction of End Edge Cogging Force of Stationary Discontinuous Armature PMLSM (전기자 분산배치 PMLSM의 단부 코깅력 저감을 위한 전기자 스큐각의 영향 분석)

  • Kim, Yong-Jae;Kim, Jae-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.2
    • /
    • pp.243-248
    • /
    • 2014
  • The permanent magnet linear synchronous motors facilitate maintenance, for it is structurally simple compare to rotating machine and has lots of advantage such as a precision control, high speed, high thrust and so on. However, it causes an increase of material cost because of structural characteristics that need to arranges the armature on the full length of transportation lines. Thus, in order to resolve this problem, we propose the discontinuous arrangement method of the armature but the edge always exists due to the structure when the armature is arranged discontinuously. Due to this edge, the cogging force is greatly generated and it causes thrust force ripple generating noise, vibration and decline of performance. Therefore, in this paper, we examined the characteristic of end edge according to the skew angle through 3-D numerical analysis using finite element method(FEM) and improved the operation characteristics.

Current Sensorless Three Phase PWM AC/DC Boost Converter with Unity Power Factor (전류센서리스 단위역률 3상 PWM AC/DC Boost 컨버터)

  • 천창근;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.105-112
    • /
    • 2003
  • Diode rectifier which can't be controlled output voltage and phase control converter as AC/DC converter have low power factor and harmonics of lower order in the line current. In this paper, three phase PWM(Pulse Width Modulation) AC/DC boost converter is studied to solve these problems. The characteristics of a proposed converter are to control the phase of current without current sensor as a very simple control algorithm using circuit parameters only and to apply sinusoidal PWM method with fixed switching frequency due to a difficult design of input filter and switching device. We simulate for the proposed algorithm that high power factor is achieved and DC link voltage has fast dynamic response without ripple in rectifying and regenerating operation. As a result of experiment with circuit parameter(inductor, capacitor) decided in simulation, the proposed converter had high power factor and reduction of low order harmonics as against diode rectifier.

Design of Wideband Cascode Amplifiers Using a Feedback Structure (피드백 구조를 갖는 광대역 캐스코드 증폭기의 설계)

  • Lee, Jaehoon;Lim, Jongsik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.720-725
    • /
    • 2015
  • This paper describes the design of a wideband cascode amplifier using a feedback network and microwave small-signal transistors. The adopted cascode structure enables the miller effect to be lessened, cutoff frequency to increase, and reduction of gain in the mid-band to be mitigated. In addition, a feedback network is added to the cascode structure to improve the input matching and ripple performances over the wide operating band. The designed cascode amplifier contains a feedback network for small size and broadband amplification, whereas balanced amplifiers and distributed amplifiers have been used widely. The measurement shows $8.5dB{\pm}1.5dB$ of gain over 1000-2000MHz. The fabricated cascode amplifier has more than 8dB of gain over a 1000MHz bandwidth with a good flatness. The measured performances agree with the predicted ones even a minor shift in operating frequency is observed.