• 제목/요약/키워드: rigid

검색결과 4,480건 처리시간 0.03초

250 km/h급 고속용 강체전차선 및 이행장치 I : 구조설계 (Overhead Rigid Conductor and Transition Structure for High-Speed (Over 250 km/h) I : Structural Design)

  • 김봉석;원용희;박설희;배상준;장광동
    • 한국생산제조학회지
    • /
    • 제25권1호
    • /
    • pp.7-13
    • /
    • 2016
  • With the increasing running speed of trains, new railway lines in metropolitan areas, and the rising demand for green transportations, the number of underground and tunnel sections are constantly becoming larger, and installations of overhead rigid conductor systems are becoming wider. However, domestic commercial products for overhead rigid conductors are limited to 120 km/h train speeds. In this study, to develop a high-speed (250 km/h) overhead rigid conductor, R-Bar (Rigid Bar), the electrical and mechanical stability was enhanced through the improvement of the cross sectional shape of the R-Bar; the transition structure was also designed for flexibility and natural frequency isolation. In addition, the evaluation of contact forces between a pantograph and the overhead rigid conductor system for 250 km/h train speeds was performed using dynamic analysis.

Modelling and experiment of semi rigid joint between composite beam and square CFDST column

  • Guo, Lei;Wang, Jingfeng;Zhang, Meng
    • Steel and Composite Structures
    • /
    • 제34권6호
    • /
    • pp.803-818
    • /
    • 2020
  • Semi-rigid connections with blind bolts could solve the difficulty that traditional high strength bolts were unavailable to splice a steel/composite beam to a closed section column. However, insufficient investigations have focused on the performance of semi-rigid connection to square concrete filled double-skin steel tubular (CFDST) columns. In this paper, a component model was developed to evaluate the mechanical behavior of semi-rigid composite connections to CFDST columns considering the stiffness and strength of column face in compression and column web in shear which were determined by the load transfer mechanism and superstition method. Then, experimental investigations on blind bolted composite joints to square CFDST columns were conducted to validate the accuracy of the component model. Dominant failure modes of the connections were analyzed and this type of joint behaved semi-rigid manner. More importantly, strain responses of CFDST column web and tubes verified that stiffness and strength of column face in compression and column web in shear significantly affected the connection mechanical behavior owing to the hollow part of the cross-section for CFDST column. The experimental and analytical results showed that the CFDST column to steel-concrete composite beam semi-rigid joints could be employed for the assembled structures in high intensity seismic regions.

단조하중을 받는 철골구조물의 접합부 연성도에 관한 연구 (A Study on Connection Ductility of Steel Structures Subjected to Monotonic Loading)

  • 강석봉;김진형
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.375-385
    • /
    • 2000
  • 6층 비가새 및 20층 가새 철골구조물에서 기하 비선형, 재료 비선형, 접합부 비선형을 고려할 때 극한 횡하중에 대해 요구되는 접합부 연성도를 파악하였다. 재료 비선형을 고려하기 위하여 단면 모멘트-곡률 관계는 Fiber 모델을 이용하고 부재 강성행렬은 유연도 선형분포 해석모델을 이용하여 유도하였다. 강접합부를 반강접합부로 대체한 6층 구조물의 접합부 연성도는 강접합부인 경우 보다 적었고 20층 구조물에서 요구되는 반강접합부 연성도는 전단접합부의 경우와 거의 같고 강접합부는 전단접합부나 반강접합부에 비하여 큰 연성도가 필요하였다.

  • PDF

Molecular Dynamics Simulation Studies of Zeolite A. Ⅶ. Structure and Dynamics of $H^+$ ions in a Nom-Rigid Dehydrated H12-A Zeolite Framework

  • 이송희;최상구
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권3호
    • /
    • pp.285-290
    • /
    • 1999
  • In the present paper, we report a molecular dynamics (MD) simulation study for the structure and dynamics of H+ ions in non-rigid dehydrated H12-A zeolite framework at 298.15 K, using the same method we used in our previous studies of rigid and non-rigid zeolite-A frameworks. It is found that two different structures appear, depending on the choice of the Lennard-Jones parameter (σ) for the H+ ion, as is also observed in the study of rigid dehydrated H12-A zeolite framework, but the ranges of σ are different for the two structures. It is also found that some of the H+ ions exchanged their sites without changing the number of H+ ions at each site. The agreement between experimental and calculated structural parameters for non-rigid dehydrated H12-A zeolite is generally quite good. The calculated IR spectrum by Fourier transform of the total dipole moment auto-correlation function shows two major peaks, one around 2700 cm-1 and the other around 7000 cm-1. The former appears in the calculated IR spectra of non-rigid zeolite-A framework only system and the latter remains unexplained except, perhaps, as an indication of a new formation of a vibrational mode of the framework due to the adsorption of the H+ ions.

Bearing capacity and failure mechanism of skirted footings

  • Shukla, Rajesh P.;Jakka, Ravi S.
    • Geomechanics and Engineering
    • /
    • 제30권1호
    • /
    • pp.51-66
    • /
    • 2022
  • The article presents the results of finite element analyses carried out on skirted footings. The bearing capacity increases with the provision of the flexible and rigid skirt, but the effectiveness varies with various other factors. The skirts are more efficient in the case of cohesionless soils than cohesive and c-ϕ soils. Efficiency reduces with an increase in the soil strength and footing depth. The rigid skirt is relatively more efficient compared to the flexible skirt. In contrast, to the flexible skirt, the efficiency of the rigid skirt increases continuously with skirt length. The difference in the effectiveness of both skirts becomes more noticeable with an increase in the strength parameters, skirt length, and footing depth. The failure mechanism also changes significantly with the inclusion of a rigid skirt. The rigid skirt behaves as a solid embedded footing, and the failure mechanism becomes confined with an increase in the skirt length. Few small-scale laboratory tests were carried out to study the flexible and rigid skirt and verify the numerical study results. The numerical analysis results are further used to develop nonlinear equations to predict the enhancement in bearing capacity with the provision of the rigid and flexible skirts.

불연속체 구조물의 해석을 위한 강체-고체 복합모델의 개발 (A Development of the Coupled Model by Rigid and Solid Bodies for Discontinuous Structures)

  • 김승덕;정하선
    • 전산구조공학
    • /
    • 제11권4호
    • /
    • pp.169-176
    • /
    • 1998
  • 불연속적 거동이 탁월한 벽식 프리캐스트 구조물을 해석하기 위한 방법으로 유한요소법과 강체요소법 등이 있으나, 이들 해석법은 접합부의 거동을 정확히 반영하지 못하고 있다. 본 연구에서는 패널은 강체적 거동을 하고, 판널과 판널 사이의 접합부는 고체적 거동을 가정하는 강체-고체 복합모델(Coupled Model by Rigid and Solid bodies)에 의한 해석법을 제안하며, 간단한 모델의 예를 통해 검증하였다.

  • PDF

반강접 접합부를 적용한 초대형 부유식 구조물 상부구조체에 대한 동적해석 (Dynamic Analysis of Superstructures on Very Large Floating Structure with Semi-Rigid Connections)

  • 송화철;김우년
    • 한국항해항만학회지
    • /
    • 제29권5호
    • /
    • pp.389-394
    • /
    • 2005
  • 초대형 부유식 구조물의 경우 지진하중보다 파랑하중에 의한 영향이 크게 작용하기 때문에 파랑하중에 의한 하부부체의 변형이 상부구조물에 부가모멘트를 발생시키는 요인이 된다. 이러한 부가모멘트를 저감시키기 위해 본 연구에서는 강접합과 핀접합 사이의 거동을 하는 반강접 접합부를 적용하였다. 초대형 부유식 구조물의 상부구조체에 반강접 접합부를 적용할 경우 보의 부가모멘트를 감소시킬 수 있으며, 더욱 경제적인 설계가 가능하다. 본 논문에서는 4경간 3층 예제구조물에 대하여 파랑하중에 의한 영향을 분석하고, 구조물의 반강접 접합부 적용에 따른 효율성을 검토하였다. 접합부는 각형강관 외-다이아프램 접합부를 적용하였으며 파랑하중에 의한 동적 특성을 분석하기 위하여 시간 이력해석을 수행하였다. 초대형 부유식 구조물의 상부구조물의 경우 파랑하중에 의해서 정하중의 최대모멘트 응답이 강접 구조물에서는 $33\%$ 증가하였으며, 스프링 모델을 이용한 반강접 구조물에서는 $26\%$ 증가하였다.

판에 고속 충돌하는 봉의 동적 파괴에 관한 연구 (Study on the Dynamic Fracture of Rod Impacting on Plate at High Speed)

  • 조재웅;한문식
    • 한국공작기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.108-112
    • /
    • 2007
  • This study analyzes the dynamic fracture phenomenon that aluminum rod impacts aluminum plate or rigid plate and deforms. The value of von-Mises stress in the instance that aluminum rod deforms on rigid plate after contact becomes 1.3 times as large as that in the instance of contact. On the contrary, the value of von-Mises stress in the instance that aluminum rod goes through aluminum plate after contact becomes 0.7 times as small as that in the instance of contact. The value of internal energy in the instance that aluminum rod contacts aluminum plate becomes 2.3 times as large as that in the instance that aluminum rod contacts rigid plate. But the value of kinetic energy in the instance that aluminum rod contacts aluminum plate becomes 0.9 times as small as that in the instance that aluminum rod contacts rigid plate. The value of internal energy in the instance that aluminum rod goes through aluminum plate after contact becomes 0.7 times as small as that in the instance that aluminum rod impacts rigid plate and deforms. And the value of sliding energy in the instance that aluminum rod contacts aluminum plate becomes 0.2 times as small as that in the instance that aluminum rod contacts rigid plate. The value of total energy in case that aluminum rod impacts aluminum plate becomes 0.9 times as small as that in the case that aluminum rod impacts rigid plate.

어태치먼트를 이용한 IMZ 임플랜트와 자연치의 연결시 고정유무의 연결형태에 따른 광탄성 응력분석에 관한 연구 (A STUDY OF PHOTOELASTIC STRESS ANALYSIS IN THE IMZ IMPLANT-NATURAL 700TH SUPPORTED FIXED PARTIAL DENTURE USING ATTACHMENT WITH OR WITHOUT RIGID CONNECTION)

  • 김정선;황영필;계기성
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.130-143
    • /
    • 1995
  • The purpose of this study was to analyze the magnitude and distribution of stress using photoelastic model with the rigid connection using T-block attachment and non-rigid connection using key & keyway attachment. The vertical load of 16 Kg was applied on the central fossa of the tooth, the pontic and the implant, and the pattern and distribution under each condition was analyzed. The following results were obtained : 1. In case of vertical load on the central fossa of the implant, the stress was concentrated at the apex of the implant involving the mesial alveolar bone in both fixed partial denture with the rigid connection and that with the nonrigid connection and the stress concentration at the mesial cervical area of the implant was a little more in the nonrigid connection than in the rigid connection. 2. In case of vertical load on the central fossa of the pontic, the stress was concentrated at the apex of 2nd bicuspid in both 3 unit fixed partial denture with nonrigid connection and that with the rigid connection. The stress was more concentrated at the mesial alveolar bone of the implant, but the stress distribution at the natural teeth more favorable at the rigid connection than at the non-rigid connection in case of 4 unit fixed partial denture. 3. In case of vertical load of the central fossa of the 2nd bicuspid, much stress with 3 fringe order was observed at the apex of the 2nd bicuspid in the 3 unit fixed partial denture, but relatively even stress distribution was observed at the apex of the implant, the 1st and 2nd bicuspid, and the adjacent cuspid in the 4 unit fixed partial denture.

  • PDF

Conformation이 고정된 Sulfonylurea 유도체의 혈당상승작용 (Hyperglycemic Effect of Conformationally Rigid Sulfonylurea Derivatives)

  • 박혜영;김연경;권진숙;김화정
    • Biomolecules & Therapeutics
    • /
    • 제4권4호
    • /
    • pp.408-410
    • /
    • 1996
  • 3, 4-Dihydro-3-oxo-2H-1, 2, 4-benzothiadiazine-1, 1-dioxides were synthesized as conformationally rigid analogues of sulfonylurea hypoglycemic agents. All the compounds prepared showed hyperglycemic activity. The hyperglycemic activity was enhanced for the diabetic rats in which the blood glucose level was increased by 30-70%.

  • PDF