• Title/Summary/Keyword: right-sensitivity

Search Result 209, Processing Time 0.023 seconds

Correlation between Magnetic Resonance Image Signal Changes and Electromyographic Findings after Sciatic Nerve Transection in the Rat (백서의 좌골신경 절단 후 비복근의 자기공명영상 신호강도 변화와 근전도 소견의 관계)

  • Lee, Joo Hwan;Lee, Jang Chul;Kim, Dong Won;Park, Ki Young;Lee, Sung Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.101-107
    • /
    • 2000
  • Objectives : The evaluation of peripheral nerve injuries has traditionally relied on a clinical history, physical examination, and electrodiagnostic studies. The purpose of the present study was to examine serial magnetic resonance image(MRI) changes following acute muscle denervation under experimental conditions and to identify potential advantages and disadvantages of this use of MRI. Methods : An experimental transection of right sciatic nerve on Spargue-Dawley rats was performed. MRI was performed with T1-weighted spin-echo and STIR sequences. The imaging findings were compared with EMG in order to determine its sensitivity relative to this standard procedure. A simultaneous histopathological study provided information about the morphological basis of the imaging findings. Signal intensities were expressed as a ratio of abnormal to normal. Results : The signal intensity ratio of muscles with the STIR sequence was increased significantly at 2 weeks after sciatic nerve transection(p<0.05), although definite signal change was seen as early as 4 days postdenervation in one. EMG revealed significant denervation potential from 3 days after nerve transection. Diffuse cell atrophy was revealed hostologically at 2 weeks after transection, which was at the same time of significant signal change in MRI. Conclusion : MRI signal changes in denervated muscles secondary to nerve injury correlate with the degree of muscle atrophy on histologic examination. In addition to EMG, MRI can document the course of muscle atrophy and mesenchymal abnormalities in denervation. These results indicate that MRI can play a complementary role in the evaluation of patients with denervation.

  • PDF

An Analysis of Economic Effects of Korean Fisheries using Input, Output Analysis (산업연관분석을 이용한 수산업의 경제적 파급효과 추이 분석)

  • Park, Kyoung-Il;Park, Joon-Soon;Seo, Ju-Nam
    • The Journal of Fisheries Business Administration
    • /
    • v.43 no.3
    • /
    • pp.75-87
    • /
    • 2012
  • Today, the Korean fisheries is undergoing significant hardships, both domestically and internationally. While declining amount of catch, ascending international oil prices and others pose a compelling challenge to the fishing sector, the ever strengthening influence of international institutions related to fisheries and international trade organizations also compel to bring about myriad of changes in the realm of fishery products. Against the backdrop, this study attempted to examine the fisheries catch, aquaculture, service, processing fields in terms of its rippling effect and of how the industry has been changed by analyzing the past and present through an input-output analysis. As for research methods, 168 items of the input-output tables in 2000, 2005, 2009, and 2010 were integrated to form and classify 32 sectors (28 basic sectors + catch, aquaculture, fishery service, processed fishery products) so as to generate production inducement coefficient, sensitivity coefficient, and impact coefficient. The analysis results revealed that : though the linkage effect of fishery industry was not very sizable, the impact coefficient of the processed fishery products was high; the consumption and investment coefficient sector among production inducement coefficient was on an upturn trend ; the export coefficient was tended to decline. In the future research, it is necessary to carry out a study based on the integration of detailed classification (404 sector) and a study and analysis of fishery industry by different regions through the inter-regional input-output tables. The fishery industry is one of the crucial industries in Korea. The fishery industry is not only important in its own right but also significant as it exerts influence over other industries. Therefore, it is required that there should be more investment and supports for the development of the fishery industry, and pay efforts to ensure that the investment and development could lead to mutual growth for both the fishery and other various industries.

A Secure Personal Health Record System for Handling of Emergency Situations (응급 상황 처리를 위한 안전한 개인건강기록 시스템)

  • Yi, Myung-Kyu;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.117-123
    • /
    • 2016
  • In recent years, Personal Health Record (PHR) has emerged as a patient-centric model of health information exchange. The Personal Health Record (PHR) owners enjoy the full right of accessing their records anywhere and anytime making storage and retrieval more efficient. Due to the sensitivity and confidential nature of the PHR, however, the PHR is maintained in a secure and private environment with the individual determining rights of access. In this paper, we propose a system which enables access to the user's PHR in the event of emergency. In emergency situation where the user is unconscious, the emergency staff can use the PHR information to request a emergency access to the PHR server based on the predefined rights of access for PHR. Under the proposed system, the PHR owner can specify a fine grain access control policy during emergency situations.

Effectiveness of a 5-year Community Oral Health Program for the Elderly in Korea

  • Song, Eun-Joo;Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.17 no.3
    • /
    • pp.202-208
    • /
    • 2017
  • Korea has been running the community oral health program for the elderly, including topical fluoride application and scaling. The aim of this study was to compare the subjective and objective oral health status of 345 participants according to the number of participants in the program and of 37 participants before and after the 5-year program. The survey consisted of an interview questionnaire and oral examinations. Analysis of variance was used to compare the variables of the 345 participants according to the numbers of participants. Paired t-test was used to compare the oral health statuses before and after the 5-year program in 37 subjects. There was no difference in subjective oral health status according to the number of participants in the oral health program in the elderly, including subjective health status, subjective oral health status, satisfaction with oral health, concern about oral health, need of dental treatment, oral pain, tooth sensitivity, subjective periodontal health, and subjective symptoms of periodontitis. The community periodontal index (CPI) of the 1 time participants was significantly higher than that of 3 times, 4 times or 5 times participants in the upper center, lower left, lower center, and lower right areas. There was a significant improvement in CPI from $2.59{\pm}1.14$ to $1.41{\pm}1.54$ (p<0.001) and positive oral behavioral change (daily tooth brushing frequency from $2.27{\pm}0.73$ to $2.54{\pm}0.90$) before and 5 years after the program. However, the program did not prevent tooth loss as the numbers of the remaining teeth significantly reduced from $23.77{\pm}1.84$ to $21.95{\pm}2.03$ over 5 years. We showed that running the community oral health program for the elderly for more than three years might have positive effects on the periodontal health of participants.

A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging

  • Hernandez, Daniel;Kim, Kyoung-Nam
    • Investigative Magnetic Resonance Imaging
    • /
    • v.24 no.3
    • /
    • pp.95-122
    • /
    • 2020
  • In this article, we evaluated the performance of radiofrequency (RF) coils in terms of the signal-to-noise ratio (S/N) and homogeneity of magnetic resonance images when used for ultrahigh-frequency (UHF) 7T magnetic resonance imaging (MRI). High-quality MRI can be obtained when these two basic requirements are met. However, because of the dielectric effect, 7T magnetic resonance imaging still produces essentially a non-uniform magnetic flux (|B1|) density distribution. In general, heterogeneous and homogeneous RF coils may be designed using electromagnetic (EM) modeling. Heterogeneous coils, which are surface coils, are used in consideration of scalability in the |B1| region with a high S/N as multichannel loop coils rather than selecting a single loop. Loop coils are considered state of the art for their simplicity yet effective |B1|-field distribution and intensity. In addition, combining multiple loop coils allows phase arrays (PA). PA coils have gained great interest for use in receiving signals because of parallel imaging (PI) techniques, such as sensitivity encoding (SENSE) and generalized autocalibrating partial parallel acquisition (GRAPPA), which drastically reduce the acquisition time. With the introduction of a parallel transmit coil (pTx) system, a form of transceiver loop arrays has also been proposed. In this article, we discussed the applications and proposed designs of loop coils. RF homogeneous coils for volume imaging include Alderman-Grant resonators, birdcage coils, saddle coils, traveling wave coils, transmission line arrays, composite right-/left-handed arrays, and fusion coils. In this article, we also discussed the basic operation, design, and applications of these coils.

Altered Electrophysiological Properties of Coronary Artery in Iso-prenaline-Induced Cardiac Hypertrophy

  • Kim, Na-Ri;Han, Jin;Kim, Eui-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.5
    • /
    • pp.413-421
    • /
    • 2001
  • An impaired smooth muscle cell (SMC) relaxation of coronary artery by alteration of $K^+$ channels would be the most potential explanation for reduced coronary reserve in left ventricular hypertrophy (LVH), however, this possibility has not been investigated. We performed morphometrical analysis of the coronary artery under electron microscopy and measured $Ca^{2+}-activated\;K\;(K_{Ca})$ currents and delayed rectifier K $(K_{dr})$ currents by whole-cell and inside-out patch-clamp technique in single coronary arterial SMCs from rabbits subjected to isoprenaline-induced cardiac hypertrophy. Coronary arterial SMCs underwent significant changes in ultrastructure. The unitary current amplitude and the open-state probability of $K_{Ca}$ channel were significantly reduced in hypertrophy without open-time and closed-time kinetic. The concentration-response curve of $K_{Ca}$ channel to $Ca^{2+}$ is shifted to the right in hypertrophy. The reduction in the mean single channel current and increase in the open channel noise of $K_{Ca}$ channel by TEA were more sensitive in hypertrophy. $K_{dr}$ current density is significantly reduced in hypertrophy without activation and inactivation kinetics. The sensitivity of $K_{dr}$ current on 4-AP is significantly increased in hypertrophy. This is the first study to report evidence for alterations of $K_{Ca}$ channels and $K_{dr}$ channels in coronary SMCs with LVH. The findings may provide some insight into mechanism of the reduced coronary reserve in LVH.

  • PDF

The effects of intra-articular resiniferatoxin on monosodium iodoacetate-induced osteoarthritic pain in rats

  • Kim, Youngkyung;Kim, Eun-hye;Lee, Kyu Sang;Lee, Koeun;Park, Sung Ho;Na, Sook Hyun;Ko, Cheolwoong;Kim, Junesun;Yooon, Young Wook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.1
    • /
    • pp.129-136
    • /
    • 2016
  • This study was performed to investigate whether an intra-articular injection of transient receptor potential vanilloid 1 (TRPV1) receptor agonist, resiniferatoxin (RTX) would alleviate behavioral signs of arthritic pain in a rat model of osteoarthritis (OA). We also sought to determine the effect of RTX treatment on calcitonin gene-related peptide (CGRP) expression in the spinal cord. Knee joint inflammation was induced by intra-articular injection of monosodium iodoacetate (MIA, $8mg/50{\mu}l$) and weight bearing percentage on right and left hindpaws during walking, paw withdrawal threshold to mechanical stimulation, and paw withdrawal latency to heat were measured to evaluate pain behavior. Intra-articular administration of RTX (0.03, 0.003 and 0.0003%) at 2 weeks after the induction of knee joint inflammation significantly improved reduction of weight bearing on the ipsilateral hindlimb and increased paw withdrawal sensitivity to mechanical and heat stimuli. The reduction of pain behavior persisted for 3~10 days according to each behavioral test. The MIA-induced increase in CGRP immunoreactivity in the spinal cord was decreased by RTX treatment in a dose-dependent manner. The present study demonstrated that a single intra-articular administration of RTX reduced pain behaviors for a relatively long time in an experimental model of OA and could normalize OA-associated changes in peptide expression in the spinal cord.

Design and Analysis of A New Type of the Motor-Driven Blood Pump for Artificial Heart (인공심장용 전동기구동형 혈액 펌프의 설계 및 해석에 관한 연구)

  • 천길정;김희찬
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.139-150
    • /
    • 1989
  • A new motor-driven blood pump for artificial heart was developed. In this blood pump, a small size, high torque brushless DC motor was used as an energy converter and the motor rolls back and forth on a circular track. This movement of the "rolling-cyliner" causes blood ejection by alternately pushing left or right polyurethane blood sacs. This moving-actuator mechanism could be eliminate two potential problems of other motor-driven artificial hearts such as large size and poor anastomosis for the implantation. Theoretical analyses on the pump efficiency, the temperature rise, and the inflow mechanism were also performed. In a series of mock circulation tests, the theoretical analyses were compared to the measured hemodynamic and mechanical values. The pump system was shown to have sufficient cardiac output (upto 9 L/min), sensitivity to preload, and mechanical stability to be tested as an implantable total artificial heart.ial heart.

  • PDF

A Study of a Decay Parameter for the Dark Adaptation Function on the retina (망막에서 암순응 함수의 Decay parameter 연구)

  • Kim, Yong Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.145-150
    • /
    • 2000
  • The adaptation for a right source on the retina consists of the light-dark adaptation's two curves for a time by the rod-cone receptor. We obtained the adaptation for a time to measure the threshold intensities, it was two decay curves by the center of a rod-cone break. It could be represented the dark adaptation by a exponential decay function consisting of $T_{min}$, $a_r$, $a_c$, $T_{0(r)}$, $T_{0(c)}$, $t_b$, $t_c$'s parameters. The curves of a $t_b$ below and a $t_b$ above showed the adaptation sensitivity of the cone and the rod. The exponential decay function was well applied to the dark adaptation in difference retinal positions, in contrally fixated fields, in luminous, as age etc. It could be used the decay parameter as the index because of representing the properties of the dark adaptation's function.

  • PDF

An Effect of the Prefrontal Lobe Influenced by Game Music Mixed with White Noise (백색잡음을 혼합한 게임음악이 전전두엽에 미치는 영향)

  • Choi, Jong-Yun;Rhee, Dae-Woong
    • Journal of Korea Game Society
    • /
    • v.11 no.6
    • /
    • pp.3-11
    • /
    • 2011
  • The sound of digital media would be able to perform communication by stimulating body's senses. Because the sound stimuli could arouse a person into the physiological excitement and sensitivity, which appear as the changes of heartbeat, blood pressure, brain waves(EEG) signals. In this paper, we would like to examine whether the game music mixed with relaxing white noises has an effect to relax game player or not through the EEG changes of game players. For the experiment, we divided game players into group A that plays game while hearing game music mixed with white noises, and group B that plays game while hearing game music not mixed. And we measured the EEG changes of the prefrontal lobe between two groups. The result shows that the game music mixed with white noises has an relaxing effect for the left brain, but fall short of the expectations for the right brain. It would be a basic research which will contribute to the development of serious games for psychotherapy using relaxing white noises.