• 제목/요약/키워드: ribs

검색결과 807건 처리시간 0.033초

초기 횡방향 유동이 존재하는 충돌제트/유출냉각에서 요철이 설치된 유출면에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rib-roughened Surface for Impingement/Effusion Cooling System with Initial Crossflow)

  • 이동호;남용우;조형희
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.338-348
    • /
    • 2004
  • The present study is conducted to investigate the effect of rib arrangements on an impingement/effusion cooling system with initial crossflow. To simulate the impingement/effusion cooling system, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of tile hole diameter. Initial crossflow passes between the injection and effusion plates, and the square ribs (3mm) are installed on the effusion plate. Both the injection and effusion hole diameters are 10mmand Reynolds number based on the hole diameter and hole-to-hole pitch are fixed to 10,000 and 6 times of the hole diameter, respectively. To investigate the effects of rib arrangements, various rib arrangements, such as 90$^{\circ}$transverse and 45$^{\circ}$angled rib arrangements, are used. Also, the effects of flow rate ratio of crossflow to impinging jets are investigated. With the initial crossflow, locally low transfer regions are formed because the wall jets are swept away, and level of heat transfer rate get decreased with increasing flow rate of crossflow. When the ribs are installed on the effusion plate, the local distributions of heat/mass transfer coefficients around the effusion holes are changed. The local heat/mass transfer around the stagnation regions and the effusion holes are affected by the rib positions, angle of attack and rib spacing. For low blowing ratio, the ribs have adverse effects on heat/mass transfer, but for higher blowing ratios, higher and more uniform heat transfer coefficient distributions are obtained than the case without ribs because the ribs prevent the wall jets from being swept away by the crossflow and increase local turbulence of the flow near the surface. Average heat transfer coefficients with rib turbulators are approximately 10% higher than that without ribs, and the higher values are obtained with small pitch of ribs. However, the attack angle of the rib has little influence on the average heat/mass transfer.

아치 리브를 따라 작용하는 등분포 하중을 받는 포물선 아치 리브의 비탄성 면내좌굴 강도 (In-plane Inelastic Buckling Strength of Parabolic Arch Ribs Subjected Distributed Loading Along the Axis)

  • 윤기용;문지호;김성훈;이학은
    • 한국방재학회 논문집
    • /
    • 제5권1호
    • /
    • pp.55-62
    • /
    • 2005
  • 포물선 아치 리브는 원형 아치 리브와 더불어 실무에 폭넓게 적용되고 있는 아치 형상이다. 원형 아치 리브의 비탄성 면내 거동에 관한 연구는 1990년대 Trahair(1996)를 중심으로 연구가 진행되었으며, Yong-Lin Pi와 Bradford(2004)에 의하여 최근까지 연구가 활발히 진행 되고 있다. 포물선 아치 리브의 비탄성 면내 거동에 관한 연구는 일본의 연구자(Sinke, Kuranishi)을 중심으로 1970년대 후반부터 1980년대 초반에 이르기까지 많은 연구가 진행되었다. 이러한 포물선 아치 리브에 관한 일본에서의 연구는 대부분 라이즈비가 $0.1{\sim}0.2$에 국한 되어있다. 본 연구에서는 비탄성 유한요소해석을 이용하여 라이즈비가 0.1에서 0.4에 이르는 박스형태의 단면을 갖는 포물선 아치 리브의 면내 거동에 관하여 연구를 수행하였다. 연구 결과 라이즈비가 증가할수록 아치 단면에 휨모멘트가 증가하였으며, 압축력이 수직 등분포 하중을 받는 포물선 아치 리브의 면내 좌굴 안정성에 미치는 영향은 감소하였다. 마지막으로 본 연구에서는 아치 리브를 따라 작용하는 수직등분포 하중을 받는 포물선 아치의 좌굴 곡선을 제안하였다.

복합각도 요철을 가지는 사각 덕트 내의 열전달 및 압력강하 특성 (Characteristics of Heat/Mass Transfer and Pressure Drop in a Square Duct with Compound-Angled Rib Turbulaters)

  • 최청;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.325-333
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside the cooling passage of the gas-turbine blades. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. The square duct has compound-angled ribs with $60^{\circ},\;70^{\circ}$ and $90^{\circ}$ attack angles, which are installed on the test plate surfaces. a naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wall and the vertices near the side-wall. The local heat transfer and the secondary flow in the duct are changed largely according to the rib orientation. Therefore, geometry and arrangement of the ribs are important fur the advantageous cooling performance. The angled ribs increase the heat transfer discrepancy between the wall and center regions because of the interaction of the secondary flows. The average heat/mass transfer coefficient and pressure drop of the ribs with the $60^{\circ}$ $-90^{\circ}$ compound-angle are higher than those with the $60^{\circ}$ attack angle. Also, the thermal efficiency of the compound-angled rib is higher than that with the $60^{\circ}$ attack angle. The uniformity of heat/mass transfer coefficient on the cross ribs may is higher than that on the parallel ribs array.

  • PDF

NATM 터널에서 강지보와 숏크리트 합성부재의 하중지지력에 관한 연구 (A Study on Load Bearing Capacity of Composite Member with Steel Rib and Shotcrete in NATM Tunnel)

  • 문상화;신영완;김승환;유한규
    • 대한토목학회논문집
    • /
    • 제32권5C호
    • /
    • pp.221-229
    • /
    • 2012
  • NATM터널의 안정성 확보를 위해 지반조건이 불량한 경우 숏크리트에 격자지보나 H형강 등의 강지보를 보강하는 경우가 많다. 그러나 설계 시 강지보를 숏크리트가 경화되기 전 임시지보재로 간주하여 수치해석 시 고려하지 않는 것이 일반적이며, 수치해석에 고려하더라도 모델링 방법이 다양하다. 본 연구에서는 휨강도실험, 압축강도실험, 그리고 실대형실험을 통하여 강지보와 숏크리트 합성부재의 거동과 하중 부담률을 분석하였다. 또한 실험과 같은 조건에서 숏크리트와 강지보의 고려방법을 달리하여 수치해석을 실시하여 실험결과와 비교분석하였다. 연구결과 숏크리트와 강지보는 경계면에서의 미끄러짐(slip)으로 인하여 일체로 거동하지 않으며, 수치해석 시 휨모멘트는 강지보가 모두 부담하고 축력은 숏크리트와 강지보가 압축강성비에 따라 분담하는 것으로 고려하는 것이 적절한 것으로 평가되었다.

PDP 격벽 성형용 몰드 제작과 성형에 대한 연구 (A Study on Mold Fabrication and Forming for PDP Barrier Ribs)

  • 조인호;정상철;정해도;손재혁
    • 한국정밀공학회지
    • /
    • 제18권5호
    • /
    • pp.171-176
    • /
    • 2001
  • Plasma Display Panel(PDP) is a type of flat panel display utilizing the light emission produced by gas discharge. Barrier Ribs of PDP separating each sub-pixel prevents optical and electrical crosstalks from adjacent sub-pixels. Mold for forming barrier ribs has been newly researched to overcome the disadvantages of conventional manufacturing process such as screen printing, sand-blasting and photosensitive glass methods. Mold for PDP barrier ribs have stripes of micro grooves transferring glass-material wall. In this paper, Stripes of grooves of which width 48${\mu}{\textrm}{m}$ and 270${\mu}{\textrm}{m}$, depth 124${\mu}{\textrm}{m}$, pitch 274${\mu}{\textrm}{m}$ was acquired by machining hard and brittle materials of WC, Silicon, Alumina with dicing saw blade. Maximum roughness of the bottom and sidewall of the grooves was respectively 120nm, 287nm in grooving WC. Maximum tilt angle caused by difference between upper-most width and lower-most width was 2$^{\circ}$. Maximum Radius of bottom curvatures was 7.75${\mu}{\textrm}{m}$. This results satisfies the specification for barrier ribs of 50 inch XGA PDP if the groove form of mold was fully transferred to the barrier ribs. Barrier ribs were formed with Silicone rubber mold, which is transferred from grooved hard materials. Silicone rubber mold has elasticity accommodating the waveness of lower glass plate of PDP.

  • PDF

Thoracic Epidural Anesthesia and Analgesia (TEA) in Patients with Rib Fractures

  • Kim, Young-Jin;Cho, Hyun-Min;Yoon, Chee-Soon;Lee, Chan-Kyu;Lee, Tae-Yeon;Seok, June-Pill
    • Journal of Chest Surgery
    • /
    • 제44권2호
    • /
    • pp.178-182
    • /
    • 2011
  • Background: We analyzed the results of surgical reduction and fixation of ribs under thoracic epidural anesthesia and analgesia (TEA) in patients who had no more than 3 consecutive rib fractures with severe displacement to examine the clinical usefulness of this method. Materials and Methods: From May 2008 to March 2010, 35 patients underwent surgical reduction and fixation of ribs under TEA. We reviewed the indications for this technique, number of fixed ribs, combined surgical procedures for thoracic trauma, intraoperative cardiopulmonary events, postoperative complications, reestablishment of enteral nutrition, and ambulation. Results: The indications of TEA were malunion or nonunion of fractured ribs in 29 (82.9%; first operation) and incompletely ribs under previous general anesthesia in 6 (17.1%; second operation). The average number of fixed ribs per patient was 1.7 (range: 1~3). As a combined operation for thoracic trauma, 17 patients (48.6%) underwent removal of intrathoracic hematomas, and we performed repair of lung parenchyma (2), wedge resection of lung (1) for accompanying lung injury and pericardiostomy (1) for delayed hemopericardium. No patient had any intraoperative cardiopulmonary event nor did any need to switch to general anesthesia. We experienced 3 postoperative complications (8.6%): 2 extrapleural hematomas that spontaneously resolved without treatment and 1 wound infection treated with secondary closure of the wound. All patients reestablished oral feeding immediately after awakening and resumed walking ambulation the day after operation. Conclusion: Thoracic epidural anesthesia and analgesia (TEA) may positively affect cardiopulmonary function in the perioperative period. Moreover, this technique leads to an earlier return of gastrointestinal function and early ambulation without severe postoperative complications, resulting in a shortened hospital stay and lowered costs.

Research on the longitudinal stress distribution in steel box girder with large cantilever

  • HONG, Yu;LI, ShengYu;WU, Yining;XU, Dailing;PU, QianHui
    • Steel and Composite Structures
    • /
    • 제44권5호
    • /
    • pp.619-632
    • /
    • 2022
  • There are numerous structural details (Longitudinal beam, web plate, U-ribs and I-ribs) in the top and bottom plates of steel box girders, which have significant influences on the longitudinal stress (normal stress) distribution. Clarifying the influence of these structural details on the normal stress distribution is important. In this paper, the ultra-wide steel box girder with large cantilevers of the Jinhai Bridge in China, which is the widest cable-stayed bridge in the world, has been analyzed. A 1:4.5 scale laboratory model of the steel box girder has been manufactured, and the influence of structural details on the normal stress distribution in the top and bottom plates for four different load cases has been analyzed in detail. Furthermore, a three-dimensional finite element model has been established to further investigate the influence regularity of structural details on the normal stress. The experimental and finite element analysis (FEA) results have shown that different structural details of the top and bottom plates have varying effects on the normal stress distribution. Notably, the U-ribs and I-ribs of the top and bottom plates introduce periodicity to the normal stress distribution. The period of the influence of U-ribs on the normal stress distribution is the sum of the single U-rib width and the U-rib spacing, and that of the influence of I-ribs on the normal stress distribution is equal to the spacing of the I-ribs. Furthermore, the same structural details but located at different positions, will have a different effect on the normal stress distribution.

알카리저항 초단유리섬유를 리브에 사용한 유리섬유 보강근의 내구성능 (Durability of GFRP Rebar with Ribs Containing Milled Alkaline Resistant Glass Fibers)

  • 문도영;오홍섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.281-287
    • /
    • 2011
  • GFRP 보강근은 콘크리트의 알칼리성분에 의해 손상 받을 수 있다. 본 논문은 이형 GFRP 보강근의 알칼리에 대한 내구성을 증진시키기 위한 방법에 대한 실험적 연구이다. 기존 개발된 이형 GFRP 보강근의 표면물질에 삽입되는 초단유리섬유는 콘크리트와의 부착성능을 향상시키는 것으로 알려져 있다. 본 논문에서는 초단 알칼리저항섬유(AR-glass)와 E-glass 섬유를 표면이형의 구성물질로 활용하였을 때, 보강근의 내구성능에 미치는 영향을 흡습시험과 ISS 실험을 통하여 규명하고자 하였다. 혹독한 실내실험조건을 위하여 $40^{\circ}C$의 온도가 적용되었다. 실험결과, 표면성형을 위한 레진과의 합성물로써, E-glass와 AR-glass를 사용하였을 때, 내구성능에 큰 차이는 없는 것을 확인하였다. 오히려, 레진과 섬유의 혼합비가 작업성과 성형성에 영향을 미치고, 이것이 표면 이형부에 공극을 만들게 됨으로써, 큰 영향을 미치는 것으로 나타났다. 따라서, 장기적인 내구성능 확보를 위해서 혼입률의 결정에 주의를 기울여야 한다.

Characteristics of Heat Transfer in the Channel with Twisted Tape

  • Ahn, Soo-Whan;Kang, Ho-Keun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.122-128
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The rib height-to-channel hydraulic diameter ratio, $e/D_h$, is kept at 0.067 and test section length-to-hydraulic diameter ratio, $L/D_h$ is 30. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Two heating conditions are investigated for test channels with twisted tape inserts and rib turbulators: (1) electric heat uniformly applied to four side walls of the square duct, and (2) electric heat uniformly applied to two opposite ribbed walls of the square channel. Results show that the twisted tape with interrupted ribs provides a higher overall heat transfer performance over the twisted tape with no ribs.

테이프가 있는 거친 사각채널에서 가열벽면의 수가 열전달에 미치는 효과 (Effects of Number of Heating Walls on Heat Transfer in the Rough Square Channel with Twisted Tape)

  • 안수환;김명호;배성택;강호근
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.17-22
    • /
    • 2006
  • Surface modifications like rib-roughening and displaced insert devices like the twisted tape are commonly used in applications such as compact heat exchangers and cooling systems. In this paper, regionally averaged heat transfer distributions in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. Regionally averaged Nusselt number and channel averaged Nusselt number in turbulent air flows are presented for Reynold numbers from 8,900 to 29,000. We have obtained the following conclusions from the experimental study: 1) The local Nusselt number in the two-sided heated case is higher than that in the four-sided heated condition. 2) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 3) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer coefficient.

  • PDF