• 제목/요약/키워드: rhodamine

검색결과 364건 처리시간 0.02초

Rhodamine 6G Based New Fluorophore Chemosensor Toward Hg2+

  • Son, Young-A;Park, June-Min
    • 한국염색가공학회지
    • /
    • 제24권3호
    • /
    • pp.158-164
    • /
    • 2012
  • Rhodamine dyes belong to xanthene family has excellent photostability and photophysical properties. In rhodamine dyes, Rhodamine 6G and its precursors also have xanthene chromophore and it shows high fluorescent quantum yield. Rhodamine 6G derivates are simple to synthesis and its high sensitivity and water solubility are suitable as good chemosensor. In this regard, Rhodamine 6G derivates which have selectivity to specific metal cation can used to detect various heavy metal ions. In this study, rhodamine 6G derivatives were synthesized by reaction of rhodamine 6G hydrazide and glyoxal and 4-phenyl thiosemicarbazide and it showed colorimetric and fluorescence sensing toward $Hg^{2+}$ ion. This novel chemosensor was analyzed and measured on UV-Vis and fluorescence spectrophotometer. HOMO/LUMO values were also calculated by computational calculation.

Rhodamine 560을 이용한 rhodamine 6G 색소 레이저의 출력 증가 (Output Enhancement of Rhodamine 6G Dye Laser by Rhodamine 560 Energy Transfer Dye)

  • 장원권;이민희
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.266-271
    • /
    • 1994
  • 형광 스펙트럼이 Rhodamine 6G의 흡수 스펙트럼과 일치하는 Rhodamine 560을 첨가 색소로 하여 Rhodamine 6G 색소 레이저의 에너지 전달에 의한 출력 증가를 조사하였다. 펌핑 광원으로 펄스형의 경우 아르곤 기체를 주입한 동축 섬광관을 실험실에서 제작하여 사용하였으며 연속형은 아르곤 레이저를 이용하였다. 펄스형의 경우 주색소인 Rhodamine 6G의 종도가 $1\times10^{-4}mol/l$일 때 첨가 색소인 Rhodamine 560의 농도가 Rhodamine 6G농도의 1% 정도에서 에너지 전달효율이 가장 높았다. 연속형의 경우는 Rhodamine 6G의 종도가 $2\times10^{-3}mol/l$ 일 때 Rhodamine 560의 농도가 Rhodamine 6G 농도의 2.5%에서 에너지 전달효율이 가장 높았다. 아르곤 레이저의 multiline발진에 의한 출력이 3.6W일 때 18% 정도 출력이 증가하였으며 488nm와 514.5nm의 단색광으로 펌핑할 경우 아르곤 레이저의 최대 출력이 1.6W일 때 각각 72%와 88%의 출력 증가율을 보였다.

  • PDF

Rhodamine 6G 용매에 따른 CA 훈증 지문 증강 효과에 관한 연구 (A study on Enhancement Effectiveness of Cyanoacrylate Fumed Fingermark by the Solvent of Rhodamine 6G)

  • 심예라;유제설
    • 한국콘텐츠학회논문지
    • /
    • 제17권7호
    • /
    • pp.294-302
    • /
    • 2017
  • 본 연구에서는 잠재지문이 유류되어 있는 비다공성 또는 반다공성 검체를 CA 훈증하여 지문을 현출한 후 현출된 지문을 증강하기 위해 Rhodamine 6G를 사용하였다. 각기 다른 용매를 기반으로 조제한 두 종류의 Rhodamine 6G 용액 중 어떤 것이 더욱 효과적으로 지문을 증강할 수 있는지 알아보고자 하였다. 실험에 사용한 일곱 종류의 표면 모두 유기용매 기반 Rhodamine 6G보다 수용성 기반 Rhodamine 6G를 사용하였을 때 지문이 잘 증강되고 배경 염색도 적었다. 그러나 실제 현장에서 수집되는 감식 대상은 다양한 표면 재질과 색상을 가지는 한계점이 있으므로 이를 바탕으로 추후 연구가 필요할 것으로 사료된다.

시간 상관 단일 광자 계수법에 의한 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관한 연구 (Study for energy transfer from Rhodamime 6G to Rhodamine B using time correlated single photon counting method)

  • 엄효순
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1991년도 제6회 파동 및 레이저 학술발표회 Prodeedings of 6th Conference on Waves and Lasers
    • /
    • pp.69-73
    • /
    • 1991
  • 모드 동기된 아르곤 이온 레이저를 여기광원으로 사용한 시간상관 단일 광자 계수장치를 이용하여 에탄올 용액 내에서 Rhodamine 6G에서 Rhodamine B로의 에너지 전달에 관하여 연구하였다. 측정된 형광 소멸 곡선은 본 실험실에서 개발한 full-fit program으로 deconvolution 하여 reduced concentration 과 critical transfer distance를 구했다. donor 의 농도가 acceptor의 농도보다 작을 경우에는 Foster 모델이 클 경우에는 Huber 모델이 잘 맞음을 확인하였다.

  • PDF

Rhodamine B 염료의 토끼 망막 뮬러세포에 대한 선택적 염색 (Selective Accumulation of Rhodamine B in Müller cells in Rabbit Retina)

  • 권오주;이은실;전창진
    • 한국안광학회지
    • /
    • 제16권1호
    • /
    • pp.91-95
    • /
    • 2011
  • 목적: 본 연구는 토끼 망막에서 특정 신경 세포 염색이 가능한 염료를 조사하였다. 방법: Rhodamine B를 토끼의 안구내 유리체강에 주입하였다. 24시간 후, 망막을 분리하여 현미경으로 염색 상태를 관찰하였다. 염색 된 세포는 그 종류를 알아보기 위하여 면역조직화학적방법을 실시하였다. 결과: 망막 내핵층 중간 위치에서 선명하게 염색된 핵들이 관찰되었다. 염색된 세포의 분포도와 수가 뮬러세포와 비슷한 양상을 보였다. 뮬러세포인지 확인하기 위하여 vimentin 항체를 사용하였다. Rhodamine B에 의해 염색된 핵들은 vimentin 항체로 감싸져 있어 뮬러세포임을 확인하였다. 결론: Rhodamine B를 살아있는 망막에 넣을 경우 토끼 망막에 신경교세포의 특이적 염색이 나타났다.

Design and Synthesis of Novel Rhodamine-based Chemosensor Probe Toward Cu2+ Cation

  • Son, Young-A
    • 한국염색가공학회지
    • /
    • 제26권1호
    • /
    • pp.7-12
    • /
    • 2014
  • Nowdays, fluorescent rhodamine chemosensors have attracted a worldwide interest due to its ability to selectively detect heavy and transition metal cations. Due to the importance in environmental and biological toxic effects, the developments of fluorescent chemosensors have been received considerable attention in recent. Especially, a rhodamine-based chemosensor probes have been proved to be useful by exhibiting the efficient "off-on" fluorescence switching toward selected metal cations. This fluorophore can undergo the transformation from non-fluorescent and colorless spirolactam derivative to fluorescent ring-open form. In this study, a new fluorescent chemosensor was synthesized using rhodamine B through two-step procedures, and its selectivity and related optical property were characterized. Selectivity and sensitivity was found toward $Cu^{2+}$ guest molecules and then related optical properties of rhodamine B based fluorescent chemosensor compound were characterized using discussed. In addition, computational calculation was used to determine the HOMO/LUMO values.

리포솜 봉입이 로다민 123의 소장 흡수에 미치는 영향 (Effect of Liposome Encapsulation on Intestinal Absorption of Rhodamine 123)

  • 홍순선;이해리;이홍;정석재;김대덕;심창구
    • 약학회지
    • /
    • 제49권2호
    • /
    • pp.185-191
    • /
    • 2005
  • The absorption of a P-gp substrate, rhodamine 123, from a liposomal dosage form was investigated across Caco-2 cell monolayers, rat intestines and rat intestinal Peyer's patches in Ussing chamber, Rhodamine 123 was incorporated into liposomes according to the standard evaporation method, which led to a production of liposomes with a mean diameter of 71.3 nm. The permeability (Papp of rhodamine 123 from a water solution across the monolayer was $2.45{\times}10^{-6}$ cm/s for $A{\leftrightarrow}B$ (apical to basal) and $14.0{\times}10^{-6}$ cm/s for $B{\leftrightarrow}A$ (basal to apical) directions, consistent with the fact that rhodamine 123 is one of the P-gp substrates. The transport of rhodamine 123 from the liposomal dosage form was much lower for both directions compared to the solution of rhodamine 123. The transport of rhodamine 123 across the rat intestine was also significantly decreased for both directions, I.e., influx and efflux, by the liposomal incorporation of the compound. The transport of rhodamine 123 across the Peyer's patch was substantially reduced by liposomal incorporation. No difference was found in the transport between the Peyer's patch and non-Peyer's patch. These observations suggest that the contribution of transport via Peyer's patches in the uptake of liposomes may be minimal, especially for rapidly absorbed compounds like rhodamine 123. Therefore, the increased absorption of P-gp substrates does not appear to be feasible by incorporating the compounds in liposomes, due to negligible involvement of Peyer's patches in the uptake of particulate dosage forms like liposomes. Liposomes may rather represent a sustained release dosage form of incorporated compounds.

어두운 비다공성 표면에 유류된 혈지문 형광 증강에 관한 연구 (Fluorescent Enhancement of Bloody Fingermarks Deposited on Dark non-porous Surfaces)

  • 김지연;김채원;김주은;유제설
    • 한국콘텐츠학회논문지
    • /
    • 제18권2호
    • /
    • pp.124-131
    • /
    • 2018
  • 본 연구에서는 어두운 비다공성 표면에 혈지문을 유류한 후 혈지문 형광 증강 시약으로 알려진 acid yellow7(AY7), 혈흔증강용 rhodamine 6G(R6G), eosin Y의 효과성을 비교하였다. AY7과 eosin Y의 경우 혈지문 형광 증강 시약으로 국내에 소개된 바 있으나, 혈흔증강용 R6G의 경우는 그렇지 않다. 과학수사 요원이 실무에서 적용할 수 있는 방법을 제안하기 위해 각 형광 증강시약이 최적의 형광 증강 효과를 보일때 촬영을 실시하였다. 연구 결과, 혈흔증강용 R6G는 약하게 유류된 혈지문에 대한 증강 효과가 가장 뛰어난 것으로 나타났다. eosin Y는 다른 두 시약과 비교하여 모든 혈지문에 대해서 증강 효과가 약했으며, 혈액의 농담이 약한 혈지문일수록 효과가 급격하게 저하되었다. 따라서 경찰 과학수사요원이 효과적인 혈지문 증강 시약으로서 혈흔증강용 R6G를 사용해볼 것을 권장한다.

수중 플라즈마 공정을 이용한 Rhodamine B 염료의 제거 (Removal of Rhodamine B Dye Using a Water Plasma Process)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제37권3호
    • /
    • pp.218-225
    • /
    • 2011
  • Objectives: In this paper, a dielectric barrier discharge (DBD) plasma reactor was investigated for degrading the dye Rhodamine B (RhB) in aqueous solutions. Methods: The DBD plasma reactor system in this study consisted of a plasma component [titanium discharge (inner), ground (outer) electrode and quartz dielectric tube], power source, and gas supply. The effects of various parameters such as first voltage (input power), gas flow rate, second voltage (output power), conductivity and pH were investigated. Results: Experimental results showed that a 99% aqueous solution of 20 mg/l Rhodamine B is decolorized following an eleven minute plasma treatment. When comparing the performance of electrolysis and plasma treatment, the RhB degradation of the plasma process was higher that of the electrolysis. The optimum first voltage and air flow rate were 160 V (voltage of trans is 15 kV) and 3 l/min, respectively. With increased second voltage (4 kV to 15 kV), RhB degradation was increased. The higher the pH and the lower conductivity, the more Rhodamine B degradation was observed. Conclusions: OH radical generation of dielectric plasma process was identified by degradation of N, N-dimethyl-4-nitrosoaniline (RNO, indicator of OH radical generation). It was observed that the effect of UV light, which was generated as streamer discharge, on Rhodamine B degradation was not high. Rhodamine B removal was influenced by real second voltage regardless of initial first and second voltage. The effects of pH and conductivity were not high on the Rhodamine B degradation.