• Title/Summary/Keyword: reverberation room

Search Result 153, Processing Time 0.023 seconds

Characteristics of Absorption Performance of Sound Absorptive Materials according to Test Conditions (흡음재의 시험조건에 따른 흡음성능 특성)

  • Kang, Dae-Joon;Lee, W.S.;Lee, J.W.;Hong, J.K.;Jo, Y.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.683-689
    • /
    • 2006
  • The sound absorption materials have been used to enhance the performance of a noise barrier and improve the room acoustics. In this study, 6 products of sound absorption materials generally used in Korea were chosen, and their absorption performance was tested in various conditions, that is, it was measured while changing thickness, density and air-gap in their back, and measured with or without facing on their face.

Proposing a simple procedure for predicting the acoustical conditions in occupied classrooms from the measured unoccupied values (공석 시 측정값을 활용한 만석 시 강의실의 음향상태 예측법)

  • Ahn, Jae-Young;Choi, Young-Ji
    • Journal of Industrial Technology
    • /
    • v.41 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • This work proposes a simple method to use the added absorption per person values to predict the expected values of the acoustical conditions in occupied classrooms. This method is based on the effects of the values of added absorption per person on the unoccupied total absorption values of the classrooms and on other room acoustical parameters. The total sound absorption in an unoccupied classroom can be calculated from measured reverberation times in the classroom. The expected occupied absorption can be calculated using equation which was obtained in a previous study (Choi, 2017) by fitting a linear regression line to a plot of total occupied absorption versus the corresponding unoccupied total absorption values measured in 12 university classrooms. The ratios of occupied-to-unoccupied sound absorption are used to predict increments in the values of acoustical parameters that result when occupants are added to the rooms.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Effects of changes in banner size on acoustic environments in multipurpose halls for broadcasting (방송용 다목적 홀에서 배너 가변에 따른 음향 환경 변화)

  • Park, Ho-Cheul;Seo, Rosa;Seo, Chun-Ki;Jeon, Jin Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.5
    • /
    • pp.558-567
    • /
    • 2019
  • When used for broadcasting, multipurpose halls need to accommodate various types of programs such as speeches, Korean traditional music, musicals, pop music, and concerts. Therefore, multipurpose halls must meet a wide range of electric and architectural acoustic demands. However, there are few ways to alter acoustic environments for multipurpose halls, given these different demands. The current study investigates the effects of banners on acoustic environments in the presence of an acoustic shell or electric acoustic system. The results indicate that the installation of a 15% banner of wall area could vary the range of reverberation time ($T_{30}$) by 0.12 s, EDT (Early Decay Time) by 0.15 s, clarity of music ($C_{80}$) by 0.76 dB, and clarity of speech ($D_{50}$) by 6.43 % under different measurement circumstances. A computer simulation that enlarges the banner size to 40 % of the wall area varies the reverberation time from 0.11 s to 0.55 s depending on the room environment.

Sound Absorption and Thermal Insulation Characteristics of Membrane Used for Sound Field Control (음장제어용 막재료의 음향 및 단열특성)

  • Jeong, Jeong-Ho;Kim, Jeong-Uk;Jeong, Jae-Gun;Cho, Byung-Wook
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.2
    • /
    • pp.103-114
    • /
    • 2012
  • Nowadays membrane material is widely used for large indoor spaces and long spaces such as traditional market. Thermal insulation and sound field control performance is considered as a main properties for design of such buildings. In this paper sound absorption and thermal insulation properties of membrane material was investigated. Firstly, normal incidence sound absorption coefficient of 10 kinds of glass wool textiles showed that sound absorption coefficient was increased in proportion of thickness and surface density of textile. Sound absorption coefficient of 4 kinds of sound absorptive inner membrane with outer membrane was tested in the reverberation chamber. Sound absorption coefficient of mid frequency range was about 0.4 ~ 0.6. Also, sound absorption coefficient was changed by the air space behind the membrane material. Secondly, sound field control performance was investigated using mock-up space. By the installation of sound absorption membrane material, reverberation time was decreased and speech intelligibility was increased. Finally, thermal resistance and room temperature in two kinds of mock-up rooms were tested, simultaneously. Results of thermal properties showed thermal insulation properties ware increased by adding inner membrane material underneath the outer membrane.

A Study on the Acoustical Characteristics of Pistol Impluse and MLS Source Measurements in Room Types (음향측정시 실의 종류와 음원에 따르는 음향인자 측정분석에 관한 연구)

  • Kim, Jeong-Jung;Son, Jang-Ryeol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1028-1031
    • /
    • 2004
  • Last target of architectural acoustics is that people wish to convey voice effectively from the space adaptively in use purpose in building. But, to how exactly through space sound source that wish to deliver from indoor can be passed does quantification sound estimation method is proposing various kinds physical parameter to estimate degree of voice definition (Speech articulation) and reverberation. Result that evaluate sound source about MLS signal and Impluse signal by pistol in this treatise could know that converge in MLS and measurement error extent about reverberation time(RT) of sound benevolent person. And value is thought there is problem showing change irregularly about sound benevolent person of D50, C80 etc. Finally, in case is spread sound field in difference of sound pressure level, when measure about change of sound pressure level, sound benevolent person could know that there is no different effect.

  • PDF

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

An Experimental Study on the Temperature and Humidity Evaluation in the Summer and Winter Season of the Korean Traditional Houses in Chonnam Province (전남지방 전통주택 하절기와 동절기의 온습도 평가에 관한 실험적 연구)

  • Lee, Tai-Kang;Choi, Eun-Seok;Kim, Hang;Kim, Hyung-Ryul;Gi, No-Gab;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.6 no.1
    • /
    • pp.57-62
    • /
    • 2006
  • Korean Traditional houses has been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various passive system of using natural materials, considering micro climate, building lay out, and these system are more natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed control performance of outdoor environment of five Korean traditional houses during the summer and winter. These houses are varied with lay out and floor plan to reflect the way of control for environmental condition, surveyed the reverberation time and sound level difference between rooms of the main living room and other main floored room, master room and kitchen. Especially air temperature and humidity have been measured simultaneously in each rooms to compare with outdoor condition. As a result, the variation of air temperature and humidity of most rooms are considerably static while condition of outdoors are much varied, it is showed that indoor climate has been controled with traditional soiled walls.

Introduction of Floor Impact Sound Insulation Performance Test Lab. of T Company (T사 바닥충격음 실험동 소개)

  • Baek, Geon-Jong;Shin, Hoon;Song, Min-Jeong;Jang, Gil-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.17-20
    • /
    • 2008
  • To develop floor impact sound resilient materials of apartment house effectively, floor impact sound insulation performance test lab. was designed and constructed in T company. Introducing specification and basic performance of this lab. could be helpful in plan and design of another lab. Floor space size of this lab. is $4.2m{\times}5.5m$ and this size is similar with that of living room of usual apartment house's (about $100m^2$) and the height of lab. is 2.4m. Slab thickness is designed by 180mm. Frequency characteristics is similar to general apartment house. Reverberation time of sound receiving room displays 1.26sec in 125Hz by establishing sound-absorbing materials. For light weight impact sound insulation performance of concrete bare floor structure is estimated by $L_{i,AW}\;=\;73$ and for heavy weight is estimated by $L_{i,Fmax,AW}\;=\;50$. Sound pressure level distribution of sound receiving room is ranged very uniformly. With these results, floor impact sound resilient materials could be evaluated and the results could be trusted by comparison tests.

  • PDF

Factors for Speech Signal Time Delay Estimation (음성 신호를 이용한 시간지연 추정에 미치는 영향들에 관한 연구)

  • Kwon, Byoung-Ho;Park, Young-Jin;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.823-831
    • /
    • 2008
  • Since it needs the light computational load and small database, sound source localization method using time delay of arrival(TDOA method) is applied at many research fields such as a robot auditory system, teleconferencing and so on. Researches for time delay estimation, which is the most important thing of TDOA method, had been studied broadly. However studies about factors for time delay estimation are insufficient, especially in case of real environment application. In 1997, Brandstein and Silverman announced that performance of time delay estimation deteriorates as reverberant time of room increases. Even though reverberant time of room is same, performance of estimation is different as the specific part of signals. In order to know that reason, we studied and analyzed the factors for time delay estimation using speech signal and room impulse response. In result, we can know that performance of time delay estimation is changed by different R/D ratio and signal characteristics in spite of same reverberant time. Also, we define the performance index(PI) to show a similar tendency to R/D ratio, and propose the method to improve the performance of time delay estimation with PI.