• 제목/요약/키워드: reverberation chamber

검색결과 87건 처리시간 0.028초

전자파 잔향실의 교반기 매개변수에 따른 전계 균일도 향상 방안 (Improvement Scheme of Field Uniformity of Stirrer Parameter in Reverberation Chamber)

  • 김광용;홍주일;한승문;두진석;허창수;이기택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1583_1584
    • /
    • 2009
  • Reverberation chamber have become a common tool in radiated susceptibility and emission testing of electronic equipment. In a reverberation chamber, internal electromagnetic fields are mixed by metallic stirrer. Due to elimination of Polarization characteristic in reverberation chamber, electromagnetic wave reached to EUT all aspect angle. Hence, Field distribution in overmode reverberation chamber can be presented by chi-square distribution. Field uniformity in reverberation chamber have to satisfy standard deviation below 3dB and is influenced by mechanical stirrer. This paper investigates relationship between change of stirrer parameter and field uniformity in reverberation chamber.

  • PDF

투과손실 예측을 위한 유한요소 해석과 소형 잔향실 실험의 비교에 검증에 관한 연구 (Study of Sound Transmission Characteristics of using a Scale Reverberation Chamber and vibro acoustic FEM)

  • 이준헌;김범수;김관주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.92-95
    • /
    • 2011
  • The walls of modern train cars are required to have higher transmission loss since modern train have had high speed and light weight. The method based on Reverberation Chamber like KS F 2808 could be used to measure transmission loss. However, this method has difficulty in that constrained Standard of it requires extremely large facilities. Recently, the method based on Scale Reverberation Chamber is used as an alternative to Reverberation Chamber. The method of Scale Reverberation Chamber is known to be small and economical but it provides standing wave that directly influences measurement error. Therefore, this research is focus on predicting standing waves based on method of FFM and reducing measurement error by changing shape of chamber.

  • PDF

원통형 구조 전자파 잔향실 내 모드 및 필드 분포 특성 (The Characteristics of Field & Mode Distributions in a Cylindrical Reverberation Chamber)

  • 김정훈;이중근
    • 한국전자파학회논문지
    • /
    • 제14권5호
    • /
    • pp.431-436
    • /
    • 2003
  • 본 논문에서는 전자파 장해 및 복사내성 측정에 사용되는 준전자파 무반사실의 대용 방법으로 활용될 수 있는 전자파 잔향실 중에서 원통형 구조 전자파 잔향실의 전자기장 특성과 모드 분포를 연구하여 원통형 구조 전자파 잔향실의 모드 수 계산법을 제시하였으며, 이것을 사용하여 체적이 동일한 원통형 전자파 잔향실의 모드수를 반지름과 높이 비에 따라 비교 분석하였다. 또한 각각의 체적이 동일한 직사각형, 직각 이등변 삼각형, 원통형의 전자파 잔향실의 필드 균일도를 FDTD(Finite-Difference Time-Domain)를 이용하여 비교 해석하였다.

대형 잔향실의 방진 설계 및 검증 (Vibration Isolation System of a Large Reverberation Chamber)

  • 김영기;김홍배;이동우;우성현;문상무
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

2D CRD 수에 따른 전자파 잔향실 내의 필드 균일성 개선 (Improvement of Field Uniformity in a Reverberation Chamber with Various Numbers of a 2D CRD)

  • 김진복;이중근;김정훈;이유진
    • 대한전자공학회논문지TC
    • /
    • 제47권4호
    • /
    • pp.18-24
    • /
    • 2010
  • 본 논문은 전자파장해 및 복사 내성 측정에 사용되는 전자파 무반사실의 대용 방법으로 사용되는 전자파 잔향실 내의 필드 균일성에 관한 연구이다. 최근 Wireless LAN 이나 DMB 및 휴대 인터넷 사용량의 증가로 인해 전자기파 노이즈가 다른 기기나 장비에 악영향을 미칠 것으로 예상되는 2.3 GHz 대역에 초점을 맞추었다. 본 논문에서는 전자파 잔향실 내부의 전계강도 수치해석을 위하여 시간영역 유한 차분법이 사용되었으며, 전자파 잔향실의 특성과 내부 전계강도의 균일성 개선을 위하여 2D CRD의 배치와 개수를 변화시키면서 표준 편차, 공차 특성, 편파 특성을 비교분석하였다. 전자파 잔향실의 두 면에 확산기를 부착하였을 때 확산기를 사용하지 않은 전자파 잔향실에 비하여 표준 편차는 1.98 dB, 공차 특성은 3.6 dB 만큼 개선되었다.

교반기 매개변수에 따른 교반형 전자파 잔향실의 특성 및 유용성 평가 (Mode-Stirred Reverberation Chamber Characteristic to Stirrer Parameter and Usefulness Evaluation)

  • 김광용;홍주일;허창수
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1652-1657
    • /
    • 2010
  • This paper analyzes optimal stirrer parameter to improve field uniformity in a mode-stirred reverberation chamber. Stirrer parameter is varied about stirrer height and stirrer angle. Also we analyze quality factor, number of excited modes and stirrer efficiency that affect field uniformity. The results show good performance as higher as stirrer height. Isotropic field distribution is formed at $45^{\circ}$ stirrer angle. When stirrer angle varies, scattering characteristic of incident wave are changed. So electric field distribution in a mode-stirred reverberation chamber is also changed. Therefore, it affect field uniformity. The results expect to help that designs stirrer for get better field uniformity. Immunity test performed designed mode-stirred reverberation chamber for semiconductor that categorized by technology. Test result shows that good recurrence compared wave-guide immunity test.

소형잔향실을 이용한 고속철도 차량 구조재의 투과손실 연구 (A Study to Estimate Transmission Loss of HST using a Small Scale Reverberation Chamber)

  • 김태민;김정태
    • 한국철도학회논문집
    • /
    • 제14권1호
    • /
    • pp.19-23
    • /
    • 2011
  • 고속철도 차량의 고속화, 경량화와 더불어 승객의 실내 소음을 줄이기 위한 많은 연구가 진행되고 있다. 고속철도 차량의 실내 소음을 줄이는 방법으로 차량 구조물의 차음 성능을 향상시키는 연구가 중요시 되고 있으나 투과손실 연구는 많은 경제적 비용이 요구된다. 따라서 본 연구에서는 소형 잔향실을 이용하여 고속철도 차량의 투과손실을 측정할 수 있는 방법을 연구 하였다. 연구 결과 소형 잔향실을 이용한 차음성능 연구가 대형 잔향공간을 이용한 투과손실 결과 대비 신뢰성 있는 결과를 도출 하였다.

경사진 QRD를 이용한 전자파 잔향실 내 전자기장 균일도 향상을 위한 연구 (An Improvement of the Field Uniformity inside the Reverberation Chamber with Inclined QRD Set)

  • 이병준;김혜광;이중근
    • 한국전자파학회논문지
    • /
    • 제18권6호
    • /
    • pp.577-583
    • /
    • 2007
  • Schroeder 방식의 QRD(quadratic Residue Diffuser) 구조에서 더욱 진화한 경사진 QRD를 사용하여 전자파 잔향실(reverberation chamber) 내의 전자기장 균일도를 향상시켰다. FDTD(Finite-Difference Time-Domain) 수치 해석방식을 이용하여 $2{\sim}3GHz$ 대역에서의 전자파 잔향실 내의 전자기장의 분포를 해석하였다. QRD 경사 각도의 조절과 경사 방향을 전환하여 전자파 잔향실 내부의 시험 공간에서의 E_x,\;E_y,\;E_z$ 샘플의 표준편차 및 공차가 각각 0.3 dB, 2.5 dB 향상되고 전체적으로 전자기장 분포의 균일성이 확보되었다.

송신 안테나에 의한 5 GHz 이차 잔류 디퓨저를 적용한 전자파 잔향실의 내부 필드 균일도 변화 (Electric Field Uniformity in Reverberation Chamber with 5 GHz Diffuser by Transmission Antenna)

  • 이유진
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.83-86
    • /
    • 2021
  • In this paper, electric fields in electromagnetic reverberation chambers, which are used as a substitute facility for EM-free anechoic chambers, are analyzed. This paper focused on the 4-5 GHz band, which is expected to adversely affect equipment. To analyze the field uniformity inside the electromagnetic reverberation chamber, electric field strengths are sampled and finite-difference time-domain method was used for numerical analysis. Moreover, Quadratic residue diffuser was used to improve the characteristics of the electromagnetic reverberation chamber and the uniformity of the internal field strength. Standard deviation, tolerance characteristics, and partiality characteristics were compared while varying the aiming point of transmission antenna.

대형 잔향실의 방진 구조 설계 및 검증시험 (Design and Verification of a Large Reverberation Chamber's Isolation System)

  • 김홍배;이득웅
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1066-1074
    • /
    • 2004
  • A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.