• 제목/요약/키워드: retrofitting method

검색결과 182건 처리시간 0.029초

Investigation of damaged formwork timber beam retrofitting with anchoraged CFRP strip under different loading

  • Abdullah TURER;Ozgur ANIL;Abdulkadir CEVIK;R. Tugrul Erdem
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.689-703
    • /
    • 2024
  • Construction of high-rise structures, formwork systems that can be installed quickly, resistant to external loads, can be used more than once, have become a necessity. Timber and composite timber materials are preferred in the formation of such formwork systems due to their durability, ease of assembly, light weight and easy to use more than one time. Formwork beams are the most commonly used structural component in the formation of such formwork systems, and these beams can be damaged for different reasons during their lifetime. In this study, H20 top P type timber formwork beams with 1800 and 2450 mm length which is among the products of DOKA(c) company is damaged under the effect of static loading up to a high load level of 85% of the maximum ultimate capacity and after being retrofitted using anchored CFRP strips, performance and behavior of the beams under the influence of various loading types such as static, fatigue and impact are investigated experimentally. Two different lengths of retrofitted timber formwork beams were tested by applying monotonic static, fatigue and impact loading and comments were made about the effects of the retrofit method on performance under different loading types.

긴급시공이 가능한 FRP 복합재료 보강재로 보강된 기둥의 내진성능평가 (An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting)

  • 김진섭;서현수;임정희;권민호
    • 콘크리트학회논문집
    • /
    • 제26권1호
    • /
    • pp.47-55
    • /
    • 2014
  • 최근 빈번하게 발생하는 대규모의 지진으로 구조물의 내진보강에 관심이 높아지고 있다. 내진설계가 반영되지 않은 기둥의 취성파괴는 구조물 전체 붕괴를 유발하기 때문에 내진보강이 필수적이다. 기존에는 단면증설법, 강판보강법, 섬유보강법이 내진보강법으로 주로 이용되었다. 하지만 이 보강법들은 구조물의 물리적 손상과 넓은 작업공간, 오랜 시간이 소요되는 단점이 있다. 이에 이 연구에서는 기존에 개발된 FRP 보강재의 보강 성능을 평가하였다. 대상 시험체는 학교건물을 실험실 여건에 맞춰 80% 축소하여 제작하였다. 보강재의 재료를 유리섬유와 알루미늄 다공판을 사용하여 보강재를 제작하였다. 평가 결과 두 종류의 보강재를 사용한 모두에서 시험체의 내진성능이 증가하였다.

콘크리트 보강재 박리 검사를 위한 전자파 모델링 (Modeling of Electromagnetic Wave Propagation for Detection of Bond Delamination in Concrete)

  • 남연수;임홍철
    • 한국전산구조공학회논문집
    • /
    • 제17권3호
    • /
    • pp.261-269
    • /
    • 2004
  • 콘크리트 보의 내력 증강을 위해, 탄소 섬유시트와 유리 섬유시트 등의 보강재를 보의 하부에 접착시킴으로써, 기존 콘크리트 부재를 보강할 수 있다. 이러한 보강법에 대한 다양한 설계 방법 및 적용 기법들이 개발되고 있지만, 보강 후 접착 성능을 포함한 건전도 평가는 아직 실용화되지 않은 상태이다. 본 연구에서는 콘크리트 보에 부착된 보강재의 박리 여부를 검사하기 위해 전자기파의 모델링 기법을 적용하였고, 이는 박리검사용 실험 장치를 개발하기 위한 토대를 마련하는데 그 목적이 있다. 이를 위해 3GHz와 5GHz의 가우스 파와 사인 파를 입사파로 사용하여, 박리 두께가 각각 1mm와 3mm 인 콘크리트 시편에 전자파를 보내는 경우를 유한차분 시간영역법(FD-TD method)으로 모델링 하였다. 그 결과, 파형과 중심 주파수에 따라 정확도의 차이는 있었으나 박리의 유무와 위치를 찾아 낼 수 있었다.

철골 모멘트골조로 보강된 철근콘크리트 건물의 내진성능 평가 (Seismic Performance Evaluation of Non-Seismic Reinforced Concrete Buildings Strengthened by Perimeter Steel Moment Frame)

  • 김선웅
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.233-241
    • /
    • 2020
  • This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.

Retrofitted built-up steel angle members for enhancing bearing capacity of latticed towers: Experiment

  • Wang, Jian-Tao;Wu, Xiao-Hong;Yang, Bin;Sun, Qing
    • Steel and Composite Structures
    • /
    • 제41권5호
    • /
    • pp.681-695
    • /
    • 2021
  • Many existing transmission or communication towers designed several decades ago have undergone nonreversible performance degradation, making it hardly meet the additional requirements from upgrades in wind load design codes and extra services of electricity and communication. Therefore, a new-type non-destructive reinforcement method was proposed to reduce the on-site operation of drilling and welding for improving the quality and efficiency of reinforcement. Six built-up steel angle members were tested under compression to examine the reinforcement performance. Subsequently, the cyclic loading test was conducted on a pair of steel angle tower sub-structures to investigate the reinforcement effect, and a simplified prediction method was finally established for calculating the buckling bearing capacity of those new-type retrofitted built-up steel angles. The results indicates that: no apparent difference exists in the initial stiffness for the built-up specimens compared to the unreinforced steel angles; retrofitting the steel angles by single-bolt clamps can guarantee a relatively reasonable reinforcement effect and is suggested for the reduced additional weight and higher construction efficiency; for the substructure test, the latticed substructure retrofitted by the proposed reinforcement method significantly improves the lateral stiffness, the non-deformability and energy dissipation capacity; moreover, an apparent pinching behavior exists in the hysteretic loops, and there is no obvious yield plateau in the skeleton curves; finally, the accuracy validation result indicates that the proposed theoretical model achieves a reasonable agreement with the test results. Accordingly, this study can provide valuable references for the design and application of the non-destructive upgrading project of steel angle towers.

성능스펙트럼법을 이용한 기존 학교 건축물의 내진성능평가 및 보강효과 검증 (An Evaluation of Seismic Performance for Existing School Building Using Capacity Spectrum Method)

  • 장정현;황지훈;양경석;;최재혁
    • 공학기술논문지
    • /
    • 제5권1호
    • /
    • pp.11-18
    • /
    • 2012
  • Large scale earthquake was occurred in different parts of the world like Japan (in 1995), Republic of Pakistan (2005), in China (2008) etc and enormous structures were damaged. As a result of collapse of school buildings structures numerous students are died and it had a big impact on the international community. Therefore, the interest of preparing the seismic resistant school building structures in our country is increases as school building are used as emergency shelter for local residents. But the current standard of seismic design ratio of 3.7% is applied for school building in Korea which is only significant earthquake damage is expected. In order to overcome the current situation, seismic performance evaluation is carried out for the existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear analysis on existing school buildings for ATC-40(Applied Technology Council, ATC) and FEMA-356(Federal Emergency Management Agency, FEMA) are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effectiveness of seismic retrofit.

보강기법에 따른 개구부가 있는 전단벽의 보강효과 규명 (Retrofit Performance of Artificially Perforated Shearwall by Retrofit Method)

  • 최현기;이진아;최윤철;최창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.29-32
    • /
    • 2008
  • 리모델링은 친환경적 접근 방법으로써 현재 수요가 증가하고 있는 추세이다. 리모델링 사업시 구조 부재를 동반한다. 그러므로 리모델링시에 구조적인 안정성을 확보하기 위해서는 적절한 보강 방법이 요구된다. 이 연구의 목적은 전단벽에 개구부가 발생하였을 경우 Passive 보강 방식과 Active 보강 방식을 이용하였을 때의 거동 특성을 파악하는 것이다. Passive 보강 방식은 CFS나 강판 등을 부착하여 손상 부재를 보강하는 방식이고, Active 보강 방식은 프리스트레싱을 이용한 균열 제어를 통해 보강력을 도입하는 방식이다. 실험 결과 각 실험체들은 전단 파괴 형태를 보여주었고 두 가지의 다른 보강 방식은 강도나 연성에 있어서 다른 결과를 보여주었다.

  • PDF

도로교의 GIS 기반 지진피해평가체계 구축을 위한 데이터베이스 설계 (Database Design for Development of the GIS-based Earthquake Damage Evaluation System of Highway Bridges)

  • 이상호;김봉근;정동균
    • 한국지진공학회논문집
    • /
    • 제10권3호
    • /
    • pp.135-147
    • /
    • 2006
  • 본 연구에서는 도로교의 지진피해평가체계를 구축하기 위해 필요한 정보항목들을 정의하고 우리나라 실정에 맞는 데이터 베이스 구축방법을 제시하였다. 도로교 지진피해평가를 위한 정보요소는 크게 구조물 관련 정보와 위치관련 정보로 구분하였다. 구조물 관련정보는 도로망에 위치한 교량의 지진피해를 예측하는데 필요한 도로교의 취약도 곡선 정보항목으로 구성하였다. 위치관련 정보항목인 도로망의 데이터구조는 상세한 교차로 모델링이 가능하도록 기존의 GIS 데이터구조를 보다 세분화하여 정의하였다. 고속도로망에 위치한 110개의 교량을 대상으로 시범 시스템을 개발하였으며, 제시된 데이터베이스 구축 방법은 도로망의 신속한 피해복구를 위한 의사결정 지원체계 구축에 효과적으로 활용이 가능함을 보였다.

L형 GFRP 외부부착 보강된 보의 휨 실험을 통한 보강 거동분석 (Evaluation of Beam Behavior with External Bonded L-type GFRP Plate through bending Test)

  • 정영석;권민호;김진섭;남광식
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.86-93
    • /
    • 2020
  • 국내 사회기반 시설물의 경우 70년대 이후로 건설되어 향후 신규건설에 대한 수요보다 유지보수에 대한 수요가 크게 증가할 것으로 전망된다. 더욱이 경주지진과 포항지진 이후로 과거 시공된 시설물의 내진성능에 대한 평가 및 보수 보강 사업이 이루어지고 있다. 본 연구에서는 보강공법 중 L형 GFRP 외부부착공법을 대상으로 하여 시험체를 설계하고, 에폭시와 화약식 타정 총으로 압력 핀을 시공하는 방법으로 외부부착된 L형 GFRP Plate의 보강효과를 확인하기 위하여 4점 휨 시험을 수행하였다. 실험결과를 바탕으로 L형 GFRP Plate의 보강효과를 확인하고, 국내의 "복합신소재시스템에 의한 철근콘크리트구조물의 보강설계 및 시공 지침서"에 따라 L형 GFRP 외부부착공법이 적용된 보의 거동에 대하여 평가하고 에폭시와 압력 핀을 조합하여 시공하는 부착방법의 효용성을 평가하였다. 실험 결과를 분석한 결과 지침에 따른 설계는 부재의 강도를 잘 예측하는 것으로 나타났으나, GFRP Plate 보강재의 손상을 동반하는 고정법의 사용으로 인하여 설계가정의 조건을 만족하는 파괴가 일어나지 않는 것으로 분석하였다.

단부 증타 보강된 RC 전단벽체의 전단강도 (Shear Strength of Retrofitted RC Squat Wall by Additional Boundary Element)

  • 이유선;홍성걸;박영미
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.489-499
    • /
    • 2015
  • 내진 보강 공법의 보강효과 파악을 위해선 이에 대한 이론적 규명이 필요하다. 이에 본 연구는 단부에 기둥 부재를 증타한 단근 배근된 전단벽체를 대상으로 해 보강되는 기둥의 상세와 일체화 거동을 고려한 전단강도 모델을 제안했다. 이 모델은 증타된 기둥부재의 전단변형이 집중되는 길이를 가정해 이를 일체화된 벽체 내에 발생하는 스트럿 두께 산정에 이용했다. 뿐만 아니라 이 길이 내에 집중 발생하는 전단변형률을 유도, 이를 일체화 거동을 고려한 적합성 조건을 기존 전단벽체의 해석 알고리즘에 도입함으로써 증타 보강된 벽체의 해석 알고리즘을 새로이 제안했다. 또한 제안된 알고리즘을 통해 계산된 전단강도로 횡력 저항 메커니즘을 단일 스트럿 화 시켜줌으로써 보강부재의 초기강성을 제안하였다. 본 연구에서 제안한 방법의 타당성을 확인하기 위해 해석 결과 값을 본 연구에서 수행한 증타 보강된 벽체를 대상으로 한 실험뿐만 아니라 기존 RC 골조 내에 RC 전단벽체를 신설해 보강한 실험의 결과와 비교해 본 결과, 기둥부재의 상세를 고려하면서 동시에 기존 기준들에 비해 실험결과에 가깝게 예측할 수 있음을 확인했다.