• Title/Summary/Keyword: retention behavior

Search Result 258, Processing Time 0.021 seconds

Volatile Retention during Freeze Drying of Fruit Juices (과실쥬스의 동결건조 중 휘발성분 보유력)

  • 심기환;최진상;주옥수;강갑석
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.6
    • /
    • pp.555-564
    • /
    • 1990
  • The headspace gas chromatographic(analytical) technique was used to evaluate the retention of volatiles in fruit juices during freeze drying as a function of freezing rate, the content of initial solid and chamber pressure. The effects of freezing rate and drying time on the volatile retention under the experimental conditions were marked, particulary at long freezing time. The retention of volatiles in the freeze dried was largely affected by the freezing rate. The highest volatile loss under the freeze drying conditions was observed during the first stage of drying. The behavior during freeze drying of the volatile substances was affected by high content of initial solid. The volatile retention was higher in quick freeze drying than slow freeze drying and low pressure than high.

  • PDF

Separate and integral effect tests of aerosol retention in steam generator during tube rupture accident

  • Lee, Byeonghee;Kim, Sung-Il;Ha, Kwang Soon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2702-2713
    • /
    • 2022
  • A steam generator tube rupture accompanying a core damage may cause the fission product to be released to environment bypassing the containment. In such an accident, the steam generator is the major path of the radioactive aerosol release. AEOLUS facility, the scaled-down model of Korean type steam generator, was built to examine the aerosol removal in the steam generator during the steam generator tube rupture accident. Integral and separate effect tests were performed with the facility for the dry and flooded conditions, and the decontamination factors were presented for different tube configurations and submergences. The dry test results were compared with the existing test results and with the analyses to investigate the aerosol retention physics by the tube bundle, with respect to the particle size and the bundle geometry. In the flooded tests, the effect of submergence were shown and the retention in the jet injection region were presented with respect to the Stokes number. The test results are planned to be used to constitute the aerosol retention model, specifically applicable for the analysis of the steam generator tube rupture accident in Korean nuclear power plants to evaluate realistic fission product behavior.

Cycling Performance of Li4Ti5O12 Electrodes in Ionic Liquid-Based Gel Polymer Electrolytes

  • Kim, Jin-Hee;Kang, Yong-Ku;Kim, Dong-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.608-612
    • /
    • 2012
  • We investigated the cycling behavior of $Li_4Ti_5O_{12}$ electrode in a cross-linked gel polymer electrolyte based on non-flammable ionic liquid consisting of 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl) imide and vinylene carbonate. The $Li_4Ti_5O_{12}$ electrodes in ionic liquid-based gel polymer electrolytes exhibited reversible cycling behavior with good capacity retention. Cycling data and electrochemical impedance spectroscopy analyses revealed that the optimum content of the cross-linking agent necessary to ensure both acceptable initial discharge capacity and good capacity retention was about 8 wt %.

Organic Bistable Switching Memory Devices with MeH-PPV and Graphene Oxide Composite

  • Senthilkumar, V.;Kim, Yong Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.290-292
    • /
    • 2015
  • We have reported about bipolar resistive switching effect on Poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene]:Graphene oxide composite films, which are sandwiched between aluminum and indium tin oxide electrodes. In this case, I-V sweep curve showed a hysteretic behavior, which varied according to the polarity of the applied voltage bias. The device exhibited excellent switching characteristics, with the ON/OFF ratio being approximately two orders in magnitude. The device had good endurance (105 cycles without degradation) and long retention time (5 × 103 s) at room temperature. The bistable switching behavior varied according to the trapping and de-trapping of charges on GO sites; the carrier transport was described using the space-charge-limited current (SCLC) model.

Synthesis of modified polyacrylamides and their applications for the retention system of papermaking (변성 폴리아크릴 아미드의 합성 및 제지공정의 보류시스템에 응용)

  • Son, Dong-Jin;Yoon, Ji-Hyun;Choi, Eun-Jeong;Kim, Bong-Yong
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2009.04a
    • /
    • pp.23-28
    • /
    • 2009
  • The purpose of this study was to improve not only wet-end performances but also paper characteristics by the modification of various factors like molecular design and ionic characteristics of polyacrylamides First of all physical characteristics were observed after modify molecular design of the cationic polyacrylamides to linear, branched and cross-linked. In addition it was found analysis method to confirm branch degree of cationic polyacrylamides to combine ionic titration characteristics and spectroscopic behavior, After application of these structure modified polyacrylamides to the multiple retention systems with inorganic microparticles, it was found adjusting of branch degree of polyacrylamides was very important to optimize wet-end improvement. Second, After polymerization of amphoteric polyacrylamide to have both of cationic and anionic functional group in the polymer, we observed not only physical characteristics but also wet-end improvement to apply recycled pulp and found that the improvement of solution stability to prevent hydrolysis and increase of ash retention dramatically to compare traditional cationic polyacrylamide retention aid, Finally, After polymerization of anionic polyacrylamide, we observed not only wet-end improvement but also paper characteristics to apply preflocculation of PCC and it was found the improvements of flocculation efficiency, retention, ash retention, optical properties of the paper and bursting strength to compare traditional preflocculant of cationic polyacrylamide.

  • PDF

A Model Test of Earth Retention System with Prestressed Wale (프리스트레스트 띠장을 적용한 흙막이 시스템의 모형 시험)

  • Park, Jong-Sik;Kim, Sung-Kyu;Joo, Yong-Sun;Jang, Ho-June;Kim, Nak-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.27-36
    • /
    • 2007
  • A model test was performed to evaluate the stability of a new earth retention system with a prestressed wale. For the model test, the dimensional analysis of a full-scaled earth retention system with prestressed wales was performed. Details of the dimensional analysis of the new earth retention system were presented in this paper. Based on the results of the dimensional analysis, the model-scaled earth retention system with a prestressed wale was simulated. The lateral earth pressures on the wall, the lateral deflection of the prestressed wale, the sectional force on members of the prestressed wale system, and the loads of struts were measured during construction simulation. The measured results were evaluated and compared with those of the design criterion. From the measurements, the behavior of this earth retention system was investigated.

Back Analysis of Unsaturated Hydraulic Conductivities for Transient Water Release and Imbibitions Measurement (부정류 유출 및 흡입시험에 대한 불포화 투수계수의 역해석)

  • Oh, Seboong;Kim, Do-Hyung;Song, Young-Sug
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.3
    • /
    • pp.5-12
    • /
    • 2018
  • Tests for transient water release and imbibitions measurement were conducted to estimate the unsaturated hydraulic conductivities by using back analysis. By using transient hydraulic characteristics, both the soil water retention curve and hydraulic conductivity fuction can be evaluated effectively and accurately. In this study the experiment for three samples were conducted accurately to measure the change of water content with time for various steps of matric suction. The back analysis calculated the amount of transient flow reliably in comparison with the experimental results. In the soil water retention curve there was no significant difference between the result of back analysis and that of experiment. The hydraulic conductivity function from back analysis was compared with the theoretical relation based on retention curve but they showed much difference. However, the unsaturated hydraulic behavior obtained by the combination of experimental and analytical techniques are considered to agree with the actual behavior.

Retention Behavior of Lanthanide Complexes with $\alpha$ -hydroxyisobutyric Acid on Cation Exchanger (양이온 교환체에서 희토류원소와 $\alpha$-Hydroxyisobutyric Acid 착물들의 머무름 거동에 관한 연구)

  • Jo, Gi Su;Han, Seon Ho;Seo, Mu Yeol;Eom, Tae Yun;Kim, Yeon Du
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.582-592
    • /
    • 1990
  • Retention behavior of lanthanide-$\alpha$HiBA complexes was studied on the cation exchanger (LC-18 coated with $C_{20}H_{41}SO_4^-$). An equation predicting retention of lanthanides in isocratic or gradient elution with sodium ion and $\alpha$-HiBA concentration was derived from ion exchange equilibria of metal-ligand complex system, respectively. The relations between log k' and log [Na$^+$] /log [$\alpha$-HiBA) showed non-linearity in isocratic elution. In gradient elution a good linearity between log k' vs log R was obtained. The values of slopes (log k / log R) gave good agreements between calculation and experiment. Individual capacity factors ($k'_{Ln}^{3+}, k'_{LnL}^{2+}, k'{LnL2+}) and stability constant (${\beta}_1$, ${\beta}_2$, ${\beta}_3$) of lanthanide-$\alpha$HiBA complexes were calculated by the non-linear least square fittings using the retention equation. The correlation coefficients of lanthanides were shown better than 0.9996 between experiment and calculation.

  • PDF

The Relation of Peer Group Caring Interaction, Professional Self-concept, and Nurses' Retention (병원 간호사의 동료간 돌봄-배려행위, 전문직 자아개념, 재직의도의 관계)

  • Hong, Eunhee;Lee, Joo-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.3
    • /
    • pp.19-25
    • /
    • 2021
  • The purpose of this study is to understand the relation of peer group caring interaction, Professional self-concept, and Nurses' Retention. The subjects of this study are 133 nurses who have worked for more than three months at five general hospitals with more than 300 beds in S city. As a result of the study, nurses' retenstion was higher than those of under 25 years of age between 30 and 35(F=3.313, p=.039).The professional self-concept of hospital nurses has been identified as an influence factor of intent to serve. Professional self-concepts have been shown to be better with higher peer-care and consideration(r=.397, P=.004). The peer group caring interaction behavior can occur not only between colleagues but also between managers. Therefore, it is necessary to proceed with the manager's group caring interaction as a follow-up study.