A Study on Selection of Target Performance for Performance Evaluation and Maintenance of Retaining Wall in Korea (국내 옹벽의 성능평가와 유지관리를 위한 목표 성능 선정에 관한 연구)

  • Choi, Jae Soon
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.111-121
    • /
    • 2019
  • In the revised 2019 Guidelines for Facility Safety and Maintenance, the existing safety-oriented facility evaluations have expanded from performance evaluations to added durability and serviceability. This expansion reflects the life cycle of facilities and the service abilities of facilities, which are becoming a global issue. However, since the performance evaluation of facilities is linked to repairing and reinforcement, the related researches such as the correlation of each performance and the target performance related to the decision on priority are necessary. In this study, through the analysis of historical data of existing facility safety evaluation results centered on the retaining earth wall installed in domestic road facilities, the appropriate target performance was suggested for the maintenance of the facility based on the revised performance evaluation. Also, the performances on the actual two retaining walls were evaluated for example and analyzed the verification of the target performance. Besides, new indicators were presented to add serviceability to the performance evaluation of retaining earth walls consisting of safety and durability.

Analysis of the Behavior of Tiered Reinforced Soil Retaining Wall Considering the Offset Distance by Surcharge Load (상재하중 이격거리에 따른 다단식 보강토옹벽의 거동특성 분석)

  • Han, Jung-Geun;Kim, Ji-Sun;Hong, Ki-Kwon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.4
    • /
    • pp.31-40
    • /
    • 2007
  • Recently, the scale in the field of reinforced soil retaining wall has been grown up like tiered reinforced soil retaining wall. However, there have been increasing number of collapse accidents and large scale of collapse. The design manual adopted in the construction fields have been inconsistent in tiered reinforced soil retaining wall. Therefore, this study performed finite element analysis on 90 cases and analyzed characteristic behavior of lower wall which was one of the effect factors on the stability of tiered reinforced soil retaining wall. The facing displacement of each walls and the behavior of the whole ground were interpreted by the numerical analysis depending on the lower offset distance by the upper wall as well as the upper offset distance by the surcharge load. The results showed that the behavior of tiered reinforced soil retaining wall was differed by condition of surcharge load and each offset distance was found to be important factor.

Feasibility study of an earth-retaining structure using in-situ soil with dual sheet piles

  • An, Joon-Sang;Yoon, Yeo-Won;Song, Ki-Il
    • Geomechanics and Engineering
    • /
    • v.16 no.3
    • /
    • pp.321-329
    • /
    • 2018
  • Classic braced walls use struts and wales to minimize ground movements induced by deep excavation. However, the installation of struts and wales is a time-consuming process and confines the work space. To secure a work space around the retaining structure, an anchoring system works in conjunction with a braced wall. However, anchoring cannot perform well when the shear strength of soil is low. In such a case, innovative retaining systems are required in excavation. This study proposes an innovative earth-retaining wall that uses in situ soil confined in dual sheet piles as a structural component. A numerical study was conducted to evaluate the stability of the proposed structure in cohesionless dry soil and establish a design chart. The displacement and factor of safety of the structural member were monitored and evaluated. According to the results, an increase in the clearance distance increases the depth of safe excavation. For a conservative design to secure the stability of the earth-retaining structure in cohesionless dry soil, the clearance distance should exceed 2 m, and the embedded depth should exceed 40% of the wall height. The results suggest that the proposed method can be used for 14 m of excavation without any internal support structure. The design chart can be used for the preliminary design of an earth-retaining structure using in situ soil with dual steel sheet piles in cohesionless dry soil.

Lateral Pressure on ,anchored Excavation Retention walls (앵카지지 굴착흙막이벽에 작용하는 측방토압)

  • 홍원표;이기준
    • Geotechnical Engineering
    • /
    • v.8 no.4
    • /
    • pp.81-98
    • /
    • 1992
  • Deep excavation increases utility of underground spaces for high buildings. subways etc. To excavate vertically the underground, safe earth retaining walls and supporting systems should be prepared. Recently anchors have been used to support the excavation wall. The anchored excavation has some advantages toprovide working space for underground construction. In this paper the prestressed anchor loads were measured by load cells which attacted to the anchors to support the excavation walls at eight construction fields. where under-ground deep excavation was performed on cohesionless soils. The lateral pressures on the retaining walls, which are estimated from the measured anchor forces, shows a trapezoidal distribution that the pressure increases linearly with depth from the ground surface to 30% of the excavation depth and then keeps constant value regardless of the stiffness of the walls. The maximum lateral pressure was same to 63% of the Ranking active earth pressure or 17% of the vertical overburden pressure at the final depth The investigation of the measured lateral pressure on the anchored excavation walls shows that empirical earth pressure diagram presented by Terzaghi-Peck and Tschebotarioff could be applied with some modifications to determine anchor loads for the anchored excavation in cohesionless soils.

  • PDF

Permanent Basement Wall Convergence Method Using a PHC Pile (PHC 파일을 이용한 영구벽체 융합 공법)

  • Ryu, Soo-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.6
    • /
    • pp.163-169
    • /
    • 2015
  • This study was intended to suggest a new-concept construction method of permanent basement wall combined with earth retaining wall by using PHC piles to overcome the disadvantages of conventional CIP methods or the like which have been used just for earth retaining walls during field construction, and to determine its applicability. PHC piles are characterized by the reliable quality attributed to prefabrication (shop fabrication) as well as superior concrete strength and prestressing steel strength to that of CIP in the aspect of materials, and also higher bending moment than that of CIP in the aspect of structure.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load by 3D Numerical Analysis (3차원 수치해석에 의한 표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Seo, Seunghwan;Jin, Hyunsik;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.75-85
    • /
    • 2019
  • The lateral load from traffic depends on standard truck's axle loads and locations, loading distance from the inner wall. The method of limit state design has been adopted and used for design of roads in the Republic of Korea since 2015. The concept of equivalent height of soil accounting for traffic loading is often used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the standard truck of the nation, based on the findings from analytical solutions using 3D finite element method. Compare to US, the standard truck loading has a structure where the axle load is concentrated so that the equivalent load height is estimated to be slightly larger than AASHTO for lower retaining wall height. It would be reasonable to present the equivalent load height in Korea more conservatively than AASHTO in terms of securing long term stability of the retaining wall structure.

Study on Bending and Shear Strength Setting of Full-scale Model Additional Walls for Additional Wall Test Bed Combined with PHC-W Pile Retaining Wall (PHC-W말뚝 흙막이와 결합된 지하증설벽체 테스트베드 구축을 위한 실대형 지하증설벽체의 휨강도 및 전단강도 설정 연구)

  • Woo, Jong Youl;Yoo, Choong Geon;Kim, Sung Su;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.12
    • /
    • pp.7-17
    • /
    • 2018
  • Test bed additional wall combined with PHC-W pile retaining wall has been constructed. To determine the dimensions of test bed additional wall, bending and shear tests of full scale core members of additional wall were tested. Basement additional walls utilizing PHC-W pile retaining wall, which were developed by modifying the cross-section of PHC piles, were classified into the composite additional wall and the non-composite additional wall. Their tests were conducted to obtain bending strength and shear strength of basement additional walls ultilizing PHC-W pile retaining wall. Since bending strengths and shear strengths of the composite additional wall and the non-composite additional wall were similar, it could be confirmed that the non-composite additional wall could be applied instead of the composite additional wall. Full-scale model additional wall was 200 mm thick, thus the thickness of additional wall combined with PHC-W pile retaining wall could be reduced by 100~200 mm.

A Consideration on Deformation Characteristics of Soil Nailed Retaining-Walls on Field Measurements (현장계측에 의한 쏘일네일링 보강벽체의 변형특성에 관한 고찰)

  • Yoon, Bae-Sic;Lee, Jong-Moon;Kang, In-Kyu;Kwon, Young-Ho;Kim, Hong-Taek
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.534-537
    • /
    • 2007
  • The soil nailing was generally using method in practical business, in application of the soil nailing, the analysis was primarily used to Beam-Colum Method, Finite Element Method and Limit Equilibrium Method. Beam-Colum Method and Finite Element Method were able to examine transformation but widely using Limit Equilibrium Method wasn't able to examine transformation and displacement Therefore, this study was focused on presenting stability in comparison with former study-results about horizontal displacement of the soil nailing retaining-walls satisfing a criterion safety factor of Limit Equilibrium. There were performing comparison field measurements and former study-results in first step.

  • PDF

Static Earth Pressure on Rigid Walls Backfilled by Cohesionless Soils (비점성토로 뒷채움한 강성옹벽에 작용하는 정적토압)

  • 정성교;백승훈
    • Geotechnical Engineering
    • /
    • v.9 no.1
    • /
    • pp.69-78
    • /
    • 1993
  • The Coulomb and Rankine theories have been usually used for design of retaining walls, in which the earth pressures have been assumed as a triangular distribution For the rigid retaining w리1 with inclined bacuace and horizontal surface backfilled by cohesionless soils, the analytical method of earth pressure distribution has been newly suggested by using the concept of the flat arch. The active thrust obtained by this method agrees well with those by the existing theories, except the Rankine solution. The analyzed results show that the height to the center of pressure depends mainly on the inclination of the back wall and the wall friction, instead of 0.33H, where H is the wall height.

  • PDF

Integral Bridge System with Geosynthetic-Reinforced Backfill

  • Tatsuoka, Fumio
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.39-52
    • /
    • 2007
  • A new type bridge combining an integral bridge and a pair of geosynthetic-reinforced soil (GRS) retaining walls having full-height rigid (FHR) facings, called the GRS integral bridge, is proposed. The geosynthetic reinforcement layers are connected to the FHR facings (i.e., RC parapets) that are integrated with a girder without using any girder-support. GRS integral bridges are basically much more cost-effective in construction and long-term maintenance while having a much higher seismic stability than conventional-type bridges having a girder via movable and fixed supports on a pair of cantilever abutments. GRS integral bridges are better than bridges using GRS retaining walls as abutments and also than conventional integral bridges with unreinforced backfill. To validate the above, a series of static cyclic lateral loading tests of the facing and a series of shaking table tests were performed on smallscaled models of different bridge types.

  • PDF