• Title/Summary/Keyword: retained stability

Search Result 197, Processing Time 0.028 seconds

Effect of Heat Treatment on Mechanical Properties of STD11 and STS3 (공구강의 열처리 조건에 빠른 기계적 성질)

  • 박지환;이종권;류근걸;이윤배
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.3
    • /
    • pp.204-209
    • /
    • 2004
  • Using STD11 and STS3 as a mold set, accuracy of a mold product could be improved by heat treatment. Results of Charpy impact test and measurement of retained austenite in STS3 and STD11, STD11 was superior than STS3 in effect of sub-zero treatment and stability of working and measure. Decrease of retain austenite by sub-zero treatment in STS3 did not occured.

  • PDF

Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient (상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례)

  • Hong, Mun Gi;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.321-328
    • /
    • 2017
  • Treatment options for edentulous patients are complete denture and implant prosthesis. A two implant-retained overdenture can be considered the first treatment in the edentulous mandible, but there is no clear consensus of treatment for edentulous maxilla. Implant-retention/support overdenture shows better retention and stability than complete denture and is less expensive and more esthetic than implant-supported fixed prosthesis. CM $LOC^{(R)}$ $Pekkton^{(R)}$ attachment is a solitary type attachment and evaluated to have excellent abrasion resistance and retention with a female part made of poly-ether-ketone-ketone. Meanwhile, SR Ivocap system is injection molding method and discussed to show few changes in the vertical dimension of denture and have excellent fracture resistance. In this case, we restored maxillary arch with a four implant-retained overdenture using CM $LOC^{(R)}$ $Pekkton^{(R)}$ and SR Ivocap system, and mandibular arch with a removable partial denture. Through this procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.

Formation of Retainted Austenite and Mechanical Properties of 4~8%Mn Hot Rolled TRIP Steels (4~8%Mn 열연 TRIP강의 잔류오스테나이트 생성과 기계적 성질)

  • Kim D. E.;Park Y. K.;Lee O. Y.;Jin K. G.;Kim S. J.
    • Korean Journal of Materials Research
    • /
    • v.15 no.2
    • /
    • pp.115-120
    • /
    • 2005
  • The aim of this research is to develop the TRIP aided high strength low carbon steels using reverse transformation process. The $4\~8\%$ Mn steel sheets were reversely transformed by slow heating to intercritical temperature region and furnace cooling to room temperature. The stability of retained austenite depends on the enrichment of carbon and manganese by diffusion during the reverse transformation. The amount of retained austenite formed after reversely transformed at $625^{\circ}C$ for 6 hrs was about $50\;vol.\%$ in the $8\%Mn$ steel. The change in volume fraction of retained austenite with a holding temperature was consistent with the changes in elongation and the strength-ductility combination. The maximum strength-ductility combination of 40,000 $MPa{\cdot}\%$ was obtained when the $8\%Mn$ steel reversely transformed at $625^{\circ}C$ for 12 hrs. However, it's property was significantly decreased at higher holding temperature of $675^{\circ}C$ resulting from the decrease of ductility.

Finite element analysis of stress distribution on supporting bone of cement retained implant by loading location (하중 위치에 따른 시멘트 유지형 임플란트 지지골의 유한요소법 응력 분석)

  • Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.143-149
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate the effect of two different oblique mechanical loading to occlusal surfaces of cement retained implant on the stress distributions in surrounding bone, using 3-dimensional finite element method. Methods: A 3-dimensional finite element model of a cement retained implant composed of three unit implants, simplified ceramic crown and supporting bone was developed according to the design of ement retained implant for this study. two kinds of surface distributed oblique loads(100 N) are applied to following occlusal surfaces in the single crowns; 1) oblique load on 2 occlusal points(50N for each buccal cusp, 2 buccal cusps exist), 2) oblique load on 4 occlusal points(25N for each buccal and lingual cusp, 2 buccal and 2 lingual cusps exist) Results: The results of the comparison of the stress distributions on surrounding bone are as follows. In the condition of oblique load on 2 occlusal points, VMS was 741.3 Mpa in the M1(Ø$4.0{\times}13mm$) model and 251.2 Mpa in the M2(Ø$5.0{\times}13mm$) model. It means the stress on the supporting bone is decreased. The results of oblique load on 4 occlusal points are similar to this one. Conclusion: Increasing the diameter of the implant fixture is helpful to distribute the stress on the supporting bone. Also, to obtain the structural stability of the supporting bone, it is effective to distribute the load evenly on the occlusal surface of crown in producing single crown implant.

Hydrolysis of Egg Yolk Protein in a Packed Bed Reactor by Immobilized Enzyme (충진층 반응기에서 고정화 효소에 의한 난황 단백질의 가수분해)

  • Kang, Byung-Chul
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1656-1661
    • /
    • 2010
  • Alkaline protease for the hydrolysis of egg yolk protein was immobilized on five carriers - Duolite A568, Celite R640, Dowex-1, Dowex 50W and Silica gel R60. Duolite A568 showed a maximum immobilization yield of 24.7%. Optimum pH for the free and immobilized enzyme was pH 8 and 9, respectively. However, no change was observed in optimum temperature ($50^{\circ}C$). Thermal stability was observed in immobilized enzymes compared to free enzymes. The immobilized enzyme retained 86% activity after 10 cycle operations in a repeated batch process. The effect of flow rate on the stability of enzyme activity in continuous packed-bed reactor was investigated. Lowering flow rate increased the stability of the immobilized enzyme. After 96 hr of continuous operation in a packed-bed reactor, the immobilized enzyme retained 83 and 61% activity when casein and egg yolk were used as a raw materials, respectively.

Evaluation of stability of interface between CCM (Co-Cr-Mo) UCLA abutment and external hex implant

  • Yoon, Ki-Joon;Park, Young-Bum;Choi, Hyunmin;Cho, Youngsung;Lee, Jae-Hoon;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.465-471
    • /
    • 2016
  • PURPOSE. The purpose of this study is to evaluate the stability of interface between Co-Cr-Mo (CCM) UCLA abutment and external hex implant. MATERIALS AND METHODS. Sixteen external hex implant fixtures were assigned to two groups (CCM and Gold group) and were embedded in molds using clear acrylic resin. Screw-retained prostheses were constructed using CCM UCLA abutment and Gold UCLA abutment. The external implant fixture and screw-retained prostheses were connected using abutment screws. After the abutments were tightened to 30 Ncm torque, 5 kg thermocyclic functional loading was applied by chewing simulator. A target of $1.0{\times}10^6$cycles was applied. After cyclic loading, removal torque values were recorded using a driving torque tester, and the interface between implant fixture and abutment was evaluated by scanning electronic microscope (SEM). The means and standard deviations (SD) between the CCM and Gold groups were analyzed with independent t-test at the significance level of 0.05. RESULTS. Fractures of crowns, abutments, abutment screws, and fixtures and loosening of abutment screws were not observed after thermocyclic loading. There were no statistically significant differences at the recorded removal torque values between CCM and Gold groups (P>.05). SEM analysis revealed that remarkable wear patterns were observed at the abutment interface only for Gold UCLA abutments. Those patterns were not observed for other specimens. CONCLUSION. Within the limit of this study, CCM UCLA abutment has no statistically significant difference in the stability of interface with external hex implant, compared with Gold UCLA abutment.

Evaluation for Long-term Stability of EGCG Rich Green Tea Extract (EGTE) (신규 건강기능식품소재 'EGCG 고함유 녹차추출물(EGTE)'의 장기안정성 평가)

  • Cheon, Se In;Heo, Eun Ji;Yoon, Min Ji;Choi, Sang Un;Ryu, Geon-Seek;Ryu, Shi Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.4
    • /
    • pp.328-335
    • /
    • 2018
  • 'EGCG(epigallocatechin gallate) rich Green Tea extract(EGTE)' was prepared by a convenient chromatographical manner using water and alcohol which was regarded as the most suitable and appropriate process for food manufacturing. The EGCG content in EGTE was estimated above 97%. Analysis of polyphenol components in green tea, i.e., catechin(C), epigallocatechin(EGC), epicatechin(EC), epigallocatechin gallate(EGCG), epicatechin gallate(ECG) and caffeine was performed by HPLC. The optimized HPLC method exhibited a good linearity of calibration curve, accuracy and precision. The long-term stability evaluation of EGTE was carried out with a powdered formulation and solution formulation by estimating the color change and measuring the EGCG content by HPLC analysis for one year. The EGCG content of the powdered EGTE stored in a transparent bottle at room temperature was retained over 97% at the end of the experimental period. The EGCG content of 0.1% water solution of EGTE stored in a transparent bottle at RT were observed to decrease below 30%, whereas that stored at $2^{\circ}C$ retained over 70%, respectively. These results suggested that a powdered formulation could be recommended for the commercialized nutraceutical product of EGTE rather than a solution formulation.

Studies on Immobilized Alkaline Protease (고정화 Alkaline Protease 에 관한 연구)

  • 전문진;심상국;정동효
    • Microbiology and Biotechnology Letters
    • /
    • v.6 no.1
    • /
    • pp.33-40
    • /
    • 1978
  • Immobilization of alkaline protease was investigated by absorbing the enzyme on adsorbents. Alkaline protease was adsorbed on silica gel selected as a carrier to immobilize the enzyme. In this study, properties of the immobilized enzyme were compared with those of the soluble enzyme. 1) The optimum pH (10.0) of the enzyme was not changed, but the activity was increased at alkaline pH by immobilization. 2) The optimum temperature of the immobilized enzyme was shifted from 50$^{\circ}C$ to 45$^{\circ}C$, while the temperature-activity Profile became broader than those of the soluble enzyme. 3) The pH stability of the immobilized enzyme was significantely increased at pH 4.0, althouth it did not change in the neutral and alkaline pH region. 4) The heat stability of the enzyme was enhanced in the temperature range of 55$^{\circ}C$∼65$^{\circ}C$ by the immobilization. 5) The immobilized enzyme retained 40% of its original activity after repetitive use for 6 times. 6) The enzyme stability was greately improved for a prolonged storage at 4$^{\circ}C$.

  • PDF

Immobilization of Lysozyme from Hen Egg by Crosslinking Method onto Chitosan Non-woven (키토산 섬유를 담체로 이용한 라이소자임 효소의 고정화)

  • Lee, So Hee
    • Textile Coloration and Finishing
    • /
    • v.30 no.4
    • /
    • pp.264-274
    • /
    • 2018
  • Immobilization of lysozyme on chitosan non-woven using glutaraldehyde(GA) was investigated. For this, 100 % chitosan non-woven was prepared as novel support for the enzyme immobilization. In addition, free lysozyme activity was examined depending on various pH and temperature by measuring time. Moreover, the optimum immobilization conditions depending on various pH, temperature, immobilization time and lysozyme concentration was evaluated. In addition, thermal stability and storage stability of immobilized lysozyme were measured. The characteristics of immobilized lysozyme was examined by FT-IR, surface morphology, and MTT assay. The results are follows: the optimal immobilization of lysozyme were pH 7.0, $25^{\circ}C$, lysozyme concentration 1.5 mg/ml, immobilization time 240 min. The immobilized lysozyme showed higher thermal stability than the free trypsin. The immobilized lysozyme activity was retained 80 % of its initial activity at $4^{\circ}C$ over 30 days of storage. The lysozyme was immobilized effectively on chitosan non-woven by observation of surface morphology.

Full mouth rehabilitation of a partially edentulous patient with crossed occlusion using implant-retained RPD with zirconia occlusal table (엇갈린 교합을 가진 부분 무치악 환자에서 지르코니아 교합면을 가지는 Implant-Retained RPD 이용한 전악 수복 증례)

  • Kwon, Tae-Min;Seo, Chi-Won;Kim, Kyung-A;Ahn, Seung-Geun;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.314-321
    • /
    • 2016
  • Conventional removable partial dentures (RPDs) with distal extensions are associated with some problems, including lack of stability that calls for frequent relining, and cantilever actions of claps that can produce excessive loading to abutment teeth, and the need for unesthetic retentive arm clasps. Therefore, IARPDs (Implant-assisted RPD) that use implants to support or retain RPDs has been reported to improve stability, esthetics and masticatory performance of RPDs. Also, an IARPD that has zirconia occlusal table can prevent the incongruity of occlusal plane and the extrusion of antagonistic tooth. In this case of partially edentulous patient with crossed occlusion, each edentulous area was restored with implant fixed prosthesis and implant retained partial denture to suit each situation. Through the procedure, satisfactory outcomes were achieved both in functional and esthetic aspects.