• Title/Summary/Keyword: results of inspection

Search Result 3,620, Processing Time 0.049 seconds

Development of an Accuracy-improved Vision Inspection System for BGA Solder Ball (정확도를 향상시킨 BGA 솔더볼 외관검사 기법 개발)

  • Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.6
    • /
    • pp.80-85
    • /
    • 2010
  • BGA 409 chip currently the most as a visual inspection of the exterior inspection is conducted. Human depending on visual inspection of the exterior inspection of the current state of testers, depending on how the test results because the change is difficult to expect reliable results. Therefore, the challenges of visual inspection of BGA solder balls to improve the visual inspection technique was developed. However, BGA solder ball size of the microstructure and the characteristics of the distinction between hard test the accuracy of the fall orientation error has a problem. In this paper BGA solder balls exterior inspection of the accuracy to improve the edge detection algorithm, the complement of features and only the comparison proposed a pattern-matching techniques, based on the characteristics of spatial configuration of the area by improving the standard error of the orientation proposed improvements.

Usefulness estimating of Time of flight(TOF) during Carotid angio inspection including Aortic arch (Aortic arch를 포함한 Carotid angio 검사 시 Time of flight(TOF)의 유용성 평가)

  • Yoo, Yeong-Jun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose : The Carotid Angio inspection including Aortic arch applied to wide area is conducted as the Contrast Enhance MR Angiography(CEA) which is using a contrast medium. However it is a burden not only for someone such as infants, pregnant women and patients suffering from kidney failure but continuous use of contrast medium also can be a burden for patients who has been taken follow up inspection since diagnose lesion already. The purpose of this study is to estimate a usefulness of the Time of Flight (TOF) by comparing with CEA. Materials and methods : 10 patients with an average age of 58 (from 45 to 75) who had MRA inspection in our hospital were studied using 3.0 Tesla Aachieva (Philips, Netherland) MRI system and Sense Neuro-Vascular 16 Channels Coil. The same patient was inspected both TOF and CEA simultaneously. The TOF inspection included from Aortic arch to Willis Circle by connecting 3 TOF stacks and so did CEA inspection. The quantitative analysis was conducted through signal to noise ratio(SNR) and contrast to noise ratio(CNR) with soft tissue by setting up an area of interest on CCA bifurcatoin, ICA, ECA, MCA and VA concerning obtained image. In case of qualitative analysis, 3 radiological technologists and 1 radiologist evaluated 4 items (1: Visibility of the blood vessel, 2: Image distortion measure, 3: Overlapping measure with vein, 4: Peripheral blood vessel description measure) into five points scale (1: Very bad, 2: Bad, 3: Normal 4: Good, 5: Very good). Results : Results for the quantitative analysis was obtained by calculating the average of 5 ROIs in case of SNR and CNR separately. Results of SNR, TOF were generally measured higher than CEA (In case of TOF were 166.1, 205.2, 154.39, 172.23, 161.95, and CEA were 92.05, 95.43, 84.76, 73.69, 88.3). But according to the result of CNR, both TOF and CEA were measured similarly as 67.62, 106.71, 55.9, 73.74, 63.46 for TOF and 67.82, 71.19, 60.52, 49.45, 64.07 for CEA. Throughout every results of each ROI, SNR showed statistically meaningful consequence (0.050.05). In case of qualitative analysis the average of each evaluated item was 4.2points and 4.28points in the item1, 2.93points and 4.55points in the item2, 4.6points and 3.13points in the item3, 2.88points and 4.6points in the item4. According to the results TOF was measured higher in the item3 while in the item2 and item4 CEA was higher and in case of the item1, both CEA and TOF were similar. To sum up statistically meaningful results (p<0.05) were shown in the item2, item3 and item4 but not in the item1 (p>0.05). Conclusions : Both TOF and CEA are complementary because each inspection has pros and cons, but when inspect wide area including Aortic arch normally CEA is conducted. But TOF inspection also can be considered as alternative in terms of patients who has difficulty in the contrast medium such as infants, pregnant women and patients suffering from kidney failure and patients during follow up.

  • PDF

An improvement plan for a workplace monitoring system through random selection of workplaces and unnoticed measurement inspection (사업장 무작위 선정 및 불시측정 방식을 통한 작업환경측정제도 신뢰성 제고 방안)

  • Jeong, Jee Yeon;Kang, Tae Sun;Lee, Seung Gill;Park, Hae Dong;Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.105-114
    • /
    • 2017
  • Objectives: The Ministry of Employment and Labor's enforcement programs, such as workplace monitoring inspection, are one of the major public efforts to protect worker's health. Therefore, a more effective inspection method is required for workplace monitoring, which is helpful for controlling health hazards in the workplace. Methods: For this study, we investigated the related safety and health laws, regulations, and inspection guidelines from the USA, Japan, and Korea. We also analyzed the provisions of industrial safety and health acts, which are related to enhancing the reliability of workplace monitoring. We applied the process of opinion convergence through an experts meeting for our research. Results: We proposed an efficient inspection scheme for workplace monitoring that includes how to select companies(mainly randomized inspections by using a workplace measurement database and workers' compensation insurance database), how to proceed with the inspection process(mainly unannounced visits), and who should carry out this project. Conclusions: We conclude that our proposal for the inspection of workplace monitoring could be a very effective tool for reducing the numbers of companies that do not undertake workplace monitoring and could produce reliable monitoring results.

Integrated Object Detection and Blockchain Framework for Remote Safety Inspection at Construction Sites

  • Kim, Dohyeong;Yang, Jaehun;Anjum, Sharjeel;Lee, Dongmin;Pyeon, Jae-ho;Park, Chansik;Lee, Doyeop
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.136-144
    • /
    • 2022
  • Construction sites are characterized by dangerous situations and environments that cause fatal accidents. Potential risk detection needs to be improved by continuously monitoring site conditions. However, the current labor-intensive inspection practice has many limitations in monitoring dangerous conditions at construction sites. Computer vision technology that can quickly analyze and collect site conditions from images has been in the spotlight as a solution. Nonetheless, inspection results obtained via computer vision are still stored and managed in centralized systems vulnerable to tampering with information by the central node. Blockchain has been used as a reliable and efficient decentralized information management system. Despite its potential, only limited research has been conducted integrating computer vision and blockchain. Therefore, to solve the current safety management problems, the authors propose a framework for construction site inspection that integrates object detection and blockchain network, enabling efficient and reliable remote inspection. Object detection is applied to enable the automatic analysis of site safety conditions. As a result, the workload of safety managers can be reduced with inspection results stored and distributed reliably through the blockchain network. In addition, errors or forgery in the inspection process can be automatically prevented and verified through a smart contract. As site safety conditions are reliably shared with project participants, project participants can remotely inspect site conditions and make safety-related decisions in trust.

  • PDF

Availability evaluation of automatic inspection equipment using line scan camera for concrete lining (라인스캔 카메라를 이용한 콘크리트 라이닝 자동점검진단 장비 활용성 평가)

  • Lee, Gyu-Phil;Lim, Hyung-Joon;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.6
    • /
    • pp.643-653
    • /
    • 2020
  • The concrete lining inspection by inspector after traffic control poses various problems such as congestion caused by traffic control and social loss costs resulting from it, and risks of traffic accidents and safety accidents for inspectors et al. To solve the problems, the concrete lining inspection has been carried out using automatic inspection equipment and image analysis that can be objectively and quantitatively investigated in overseas. In this study, to solve the problems of concrete lining inspection by inspector and to review improvement plan for inspection, inspection was carried out using automatic inspection equipment for ◯◯ tunnel that precision safety diagnosis has been conducted in 2019. Analysis was carried out for both inspection results. Automatic inspection equipment investigated defects in concrete lining such as cracks more accurately than precision safety diagnosis.

IMPROVED POD METHODOLOGY USING MONTE CARLO SIMULATION

  • Park, Ik-Keun;Yoon, Jong-Hak;Ro, Sing-Nam;Seo, Seong-Won;Namkoong, Chai-Kwan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.73-78
    • /
    • 2003
  • Ultrasonic measurement is one of important technologies in the lift-time maintenance of nuclear poler plant. Ultrasonic inspection system is consisted of the operator, equipment and procedure. The reliability of ultrasonic inspection system is affected by its ability. The performance demonstration round robin was conducted to quantify the capability of ultrasonic inspection for in-service. The small number of teams who employed procedures that met or exceeded ASME Sec. XI Code requirements detected the piping of nuclear power plant with various cracks to evaluate the capability of detection and sizing. In this paper, the statistical reliability assessment of ultrasonic nondestructive inspection data using Monte Carlo simulation is presented. The results of the probability of detection (POD) analysis using Monte Carlo simulation are compared to these of logistic probability model. In these results, Monte Carlo simulation was found to be very useful to the reliability assessment f3r the small hit/miss data sets.

  • PDF

Automatic Optical Inspection of PCB PADs for AFVI (AFVI를 위한 PCB PAD의 자동 광학 검사)

  • Mun, Sun-Hwan
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2006.07a
    • /
    • pp.469-471
    • /
    • 2006
  • This paper describes a efficient insepction method of PCB PADs for AFVI. The methods for PCB inspection have been tried to detect the defects in PCB PADs, but their low detection rate results from pattern variations that are originating from etching, printing and handling processes. The adaptive inspection method has been newly proposed to extract minute defects based on dynamic segments and filters. The vertexes are extracted from CAM master images of PCB and then a lot of segments are constructed in master data. The proposed method moves these segments to optimal directions of a PAD contour and so adaptively matches segments to PAD contours of inspected images, irrespectively of various pattern variations. It makes a fast, accurate and reliable inspection of PCB patterns. Experimental results show that proposed methods are found to be effective for flexible defects detection.

  • PDF

Development of a VTR head inspection system (비데오 헤드 형상 검사 장치 개발)

  • 유영기;노병옥;오춘석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.8-11
    • /
    • 1996
  • In one VTR(Video Tape Recorder), two or more heads are used to record or reproduce video signals. To obtain a uniform quality of a VTR, video heads should have similar charcteristics such as geometrical shapes and electro-magnetic performances. This research is aimed to develop a visual inspection system that can measure four geoemtrical parameters;HO, HI, Tw and Cw. To obtain a high realable results, DSP based image board and target based image processing algorithms were used. A series of experiments was performed for one thousands of video heads. From observation of the experimental results, the system is found to show good performance for inspection of video heads.

  • PDF

Improvement of Predictive and Corrective Inspection Methods to Control Nosema bombycis Infection in the Silkworm, Bombyx mori

  • Nguyen, Mau-Tuan;Jon
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.2
    • /
    • pp.146-153
    • /
    • 1997
  • The microsporidian infection with Nosema bombycis, reconfirmed its high virulence and transovarial tranmissibility, however, the characteristic symptom of the spots like pepper grains on the diseased larval skin was no more recognized by present varieties of the silkworm. Transovarial transmission rate detected from moth was above 90% in dead eggs or dead larvae in the rearing by mulberry leaves, 80% in the newly hatched larvae starved to death. Transovarially transmitted N. bombycis was easily observed from dead eggs and larvae, and were suggested an individual inspection of a few of dead eggs for detection of the pathogenic spores. The progeny population provided indicative factors on the sampling of predictive and corrective inspection. The higher concentration of N. bombycis spores included in the hindabdormal part of infected moth, applicative on the simple method of indivisual moth inspection. For the predictive inspection of growned 5th-instar larvae, N. bombycis infection was detectable without microscopic observation by the unique symptom of turbid milky-white spots on the silk gland. Inspection of the meconia artificially discharged from silkworm moth, was also succesful of microscopic observation before crossing, without killing or homogenize the moths. The results provided a basis of rational methods for the inspection of N. bombycis infection of the silkworm.

  • PDF

Development of Chatbot Self-Inspection Scenario for Structural Safety of Existing Reinforced Concrete Buildings (챗봇 활용 철근콘크리트 건축물 구조안전 자가점검 시나리오 개발에 관한 연구)

  • Yang, Jaekwang;Kang, Taewook;Shin, Jiuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.331-337
    • /
    • 2023
  • Due to the aging of a building, 38.8% (about 2.82 million buildings) of the total buildings are old for more than 30 years after completion and are located in a blind spot for an inspection, except for buildings subject to regular legal inspection (about 3%). Such existing buildings require users to self-inspect themselves and make efforts to take preemptive risks. The scope of this study was defined as the general public's visual self-inspection of buildings and was limited to structural members that affect the structural stability of old buildings. This study categorized possible damage to reinforced concrete to check the structural safety of buildings and proposed a checklist to prevent the damage. A damage assessment methodology was presented during the inspection, and a self-inspection scenario was tested through a chatbot connection. It is believed that it can increase the accessibility and convenience of non-experts and induce equalized results when performing inspections, according to the chatbot guide.