• 제목/요약/키워드: results of inspection

검색결과 3,603건 처리시간 0.03초

TV용 패널 검사대 최적조명설계에 관한 연구

  • 조항준;김성환;정의승
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.3-14
    • /
    • 1995
  • To investigate the effect of illumination conditions on visual inspection performance for TV panel glasses, three dependent variables, inspection time, error, and preference , were measured and analyzed through two consecutive experiments. The first experiment for reflection inspection was conducted using two independent variables, position and brightness. The second experiment for transparent inspection was made using two independent variables, height and brightness. The summary of the results of the experiment for reflection inspection are as follows ; The inspection performance of the position right above the subject (Position 1) was the best among the conditions in terms of errors, while the performance of the position slightly in front of and above the subject(Position 2) was the best in terms of inspection times. Inspection time was statistically different according to the brightness conditions specifically at the position in front of the subject(Position 3). The results of the second experimen for transparent inspection are that the inspection performance at medium height (Height 2) was the best among the three conditions in terms of errors while the performance at lower height(Height 3) was the best in subject preference. Based upon both results with respect to actual field conditions, two alternative inspection station designs were proposed for each lighting conditon.

  • PDF

교량의 외관 조사에 의한 상태평가기준 개선안 (Improved Criteria for Condition Assessment of Bridges Based on Visual Inspection)

  • 오병환;신경준;김광수;김지상;이상철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권4호
    • /
    • pp.205-213
    • /
    • 2001
  • The condition assessment of bridges is one of the important procedures in the safety evaluation of the structures. The current inspection guideline is rather ambiguous and vague so that the inspection results based on the existing guidelines are highly subjective and varing from person to person and even day to day for a given person. It is therefore, necessary to improve the current inspection criteria in order to provide consistent results in safety assessment. To circumvent possible inconsistencies in inspection and rating of bridge components, the revised criteria have been proposed in this study. The proposed guideline and criteria may be efficiently used for the realistic and consistent assessment of bridge structures.

  • PDF

블록체인 기반 선박검사 서비스의 신뢰성 향상에 관한 연구 (A Study on the Reliability Improvement of Blockchain-based Ship Inspection Service)

  • 장춘원;강영수;이승민;박준모
    • 융합신호처리학회논문지
    • /
    • 제25권1호
    • /
    • pp.15-20
    • /
    • 2024
  • 국내 선박검사 분야는 노후화된 업무 처리 프로세스로 인해 검사 결과에 대한 위, 변조 발생 가능성을 차단하지 못하고 있다. 그에 따라 실시간으로 데이터를 추적하고 공유할 수 있는 블록체인 기술과 클라우드 기반의 시스템을 도입함으로써 검사 결과의 위변조를 방지하고, 투명하고 효율적인 의사소통 체계를 구축하기 위한 연구가 진행되고 있다. 본 연구에서는 선박검사 관련된 전체 데이터 관리 및 검사 수행에 대한 단위 및 통합 프로세스를 구현하여 선박검사 과정에서 발생하는 각종 검사 결과를 자동으로 수집하고 관리, 추적하는 체계를 구축하였다. 이를 통해 선박검사 프로세스 전반의 효율성을 높여 선박검사 산업 전반의 성장을 유도하고자 하였다. 구현된 웹 포털은 선박별 검사 결과를 토대로 결과 추이 분석과 타 선박과의 비교분석 등이 가능한 수준에 도달하였으며 후속 연구를 통해 시스템의 우수성을 실증하고자 한다.

조명과 해상도에 강인한 자동 결함 검사를 위한 향상된 히스토그램 정합 방법 (An Enhanced Histogram Matching Method for Automatic Visual Defect Inspection robust to Illumination and Resolution)

  • 강수민;박세혁;허경무
    • 제어로봇시스템학회논문지
    • /
    • 제20권10호
    • /
    • pp.1030-1035
    • /
    • 2014
  • Machine vision inspection systems have replaced human inspectors in defect inspection fields for several decades. However, the inspection results of machine vision are often affected by small changes of illumination. When small changes of illumination appear in image histograms, the influence of illumination can be decreased by transformation of the histogram. In this paper, we propose an enhanced histogram matching algorithm which corrects distorted histograms by variations of illumination. We use the resolution resizing method for an optimal matching of input and reference histograms and reduction of quantization errors from the digitizing process. The proposed algorithm aims not only for improvement of the accuracy of defect detection, but also robustness against variations of illumination in machine vision inspection. The experimental results show that the proposed method maintains uniform inspection error rates under dramatic illumination changes whereas the conventional inspection method reveals inconsistent inspection results in the same illumination conditions.

크레인 설비의 검사에 따른 기초연구 (Basic research, according to the inspection of crane equipment)

  • 안태건;심규형;이동호
    • 대한안전경영과학회지
    • /
    • 제14권4호
    • /
    • pp.169-175
    • /
    • 2012
  • Self-Inspection is being used in the workplace hazardous, dangerous machinery and equipment to build capacity for the voluntary safety risks due to use of machinery and prevention of industrial accidents that inspect facilities for safety issues, is to check. However, December 31, 2008 as part of Article 36 of the Occupational Safety and Health Act (safety inspection), the financial vanish as the self-test, Safety inspection program has been changed., In each individual workplace that creates its own standards and regulations to use the existing inspection system is in some cases. This study is located in the southeast industrial complex as a risk reducer manufacturer, machine-based target zones in S Corp owns most of the crane based on the results of the tests is to analyze the problem. Then check the results - to bring its measures and information you need to know for sure is to propose.

하나로의 안전성 관련 가동 중 검사 (In-Service Inspection for Safety Rotated Piping in HANARO)

  • 박용철
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.14-18
    • /
    • 2001
  • The primary cooling piping of HANARO is classified as safety class 3, seismic class 1 and quality class Q. This piping as safety related feature has been designed, manufactured and tested in accordance with ASME SEC. Ⅲ, DIV 1, Class 3. In October of 2000, the first step of the in-service inspection for this piping was carried out in accordance with ASME SEC. XI. This describes the results of the Inspection including the preparation of inservice inspection plan and inspection method. It is verified through the results that the safety related piping is maintained the mechanical and structural Integrities.

  • PDF

A Sampling Inspection Plan with Human Error: Considering the Relationship between Visual Inspection Time and Human Error Rate

  • Lee, Yong-Hwa;Hong, Seung-Kweon
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.645-650
    • /
    • 2011
  • Objective: The aim of this study is to design a sampling inspection plan with human error which is changing according to inspection time. Background: Typical sampling inspection plans have been established typically based on an assumption of the perfect inspection without human error. However, most of all inspection tasks include human errors in the process of inspection. Therefore, a sampling inspection plan should be designed with consideration of imperfect inspection. Method: A model for single sampling inspection plans were proposed for the cases that visual inspection error rate is changing according to inspection time. Additionally, a sampling inspection plan for an optimal inspection time was proposed. In order to show an applied example of the proposed model, an experiment for visual inspection task was performed and the inspection error rates were measured according to the inspection time. Results: Inspection error rates changed according to inspection time. The inspection error rate could be reflected on the single sampling inspection plans for attribute. In particular, inspection error rate in an optimal inspection time may be used for a reasonable single sampling plan in a practical view. Conclusion: Human error rate in inspection tasks should be reflected on typical single sampling inspection plans. A sampling inspection plan with consideration of human error requires more sampling number than a typical sampling plan with perfect inspection. Application: The result of this research may help to determine more practical sampling inspection plan rather than typical one.

교량의 외관상태평가 기준 정립에 대한 연구 (Condition Assessment Criteria for Bridges)

  • 오병환;신경준;이상철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1285-1290
    • /
    • 2000
  • The inspection of bridge condition is of extreme importance. Current inspection codes for bridge inspection are vague and uncertain. So, the results are highly subjective and different from person to person and even day to day for a given person. To circumvent possible inconsistencies in inspection and rating of bridge components, the revised inspection guidelines have been proposed.

  • PDF

Authentication Technologies of X-ray Inspection Image for Container Terminal Automation

  • Kim, Jong-Nam;Hwang, Jin-Ho;Ryu, Tae-Kyung;Moon, Kwang-Seok;Jung, Gwang-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1684-1688
    • /
    • 2005
  • In this paper, authentication technologies for X-ray inspection images in container merchandises are introduced and a method of authentication for X-ray inspection images is proposed. Until now, X-ray images of container merchandises have been managed without any authentication of inspection results and environments, it means that there was no any action for protection of illegal copy and counterfeiting of X-ray images from inspection results. Here, authentication identifies that who did inspect container X-ray images and, whether the container X-ray images were counterfeited or not. Our proposed algorithm indicates to put important information about X-ray inspection results on an X-ray image without affecting quality of the original image. Therefore, this paper will be useful in determining an appropriate technology and system specification for authentication of X-ray inspection images. As a result of experiment, we find that the information can be embedded to X-ray image without large degradation of image quality. Our proposed algorithm has high detection ratio by Quality 20 of JPEG attack.

  • PDF

Optimal Operation for Reverse Supply Chain Incorporating Inspection Policy into Remanufacturing of Used Products

  • Yamaguchi, Shin;Kusukawa, Etsuko
    • Industrial Engineering and Management Systems
    • /
    • 제16권1호
    • /
    • pp.1-21
    • /
    • 2017
  • This paper discusses a reverse supply chain (RSC) which consists of the process flows from procurement of used products collected from a market, through remanufacturing products from the used products, to sales of the products in a market. In general, it is conceivable for the RSC to face the uncertainty in quality of used products collected from a market. Inspection is one of efficient methods to deal with the problem regarding quality of used products. However, there is a trade-off between inspection cost and inspection accuracy. This paper focuses on the following five types of inspection: (1) 100% inspection, (2) sampling inspection, (3) sampling inspection with screening of rejected lots, (4) sampling inspection with screening of acceptable lots, and (5) no inspection, and determines the optimal operation consisting of the optimal number of procured used products and the optimal inspection policy. Numerical analysis clarifies not only how changes of conditions of the RSC affect the manufacturer's optimal operation but also features of each inspection type. In addition, from the results of numerical analysis, this paper shows the usability to add the proposed inspection in this paper, the sampling inspection with screening of acceptable lots, to choices of inspection type.