• 제목/요약/키워드: restorative

검색결과 2,651건 처리시간 0.031초

디지털 광원 처리 프린터로 제작된 임시수복용 레진의 후경화 기계에 따른 굴곡강도 연구 (Comparative analysis of the flexural strength of provisional restorative resins using a digital light processing printer according to the post-curing method)

  • 박영대;강월
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.341-347
    • /
    • 2020
  • Purpose: This study aimed to evaluate the effect of post-curing method on the flexural strength of provisional restorative resins produced by a digital light processing printer. Methods: A total of 20 specimens were produced, with a length of 64 mm, width of 10 mm, and thickness of 3.3 mm using a digital light processing printer. Two types of provisional restorative resins made with different post-curing methods were investigated and divided into conventional and vacuum groups. For the flexural strength test, each group was prepared by each method according to ISO 10477, and the flexural strength was measured with a universal testing machine. For statistical analysis, data were analyzed by independent t-test and Mann-Whitney U test. Results: The flexural strengths of the conventional and vacuum groups were 151.89 MPa and 131.94 MPa, respectively, showing a statistically significant difference (p<0.05). Conclusion: Within the limitation of this study, provisional restorative resins produced with vacuum demonstrated lower flexural strength than those produced with conventional postcuring method.

Outcomes of the GentleWave system on root canal treatment: a narrative review

  • Hernan Coaguila-Llerena;Eduarda Gaeta;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.11.1-11.11
    • /
    • 2022
  • This study aimed to describe the outcomes of the GentleWave system (GW) (Sonendo) on root canal treatment. Published articles were collected from scientific databases (MEDLINE/PubMed platform, Web of Science, Scopus, Science Direct and Embase). A total of 24 studies were collected from August/2014 to July/2021, 20 in vitro and 4 clinical. GW System was not associated with extrusion of the irrigant, promoted faster organic dissolution than conventional syringe irrigation (CSI), passive ultrasonic irrigation (PUI) continuous ultrasonic irrigation (CUI) and EndoVac, reduced more bacterial DNA and biofilm than PUI and CUI, promoted higher penetration of sodium hypochlorite into dentinal tubules than PUI and CUI in vitro, and removed more intracanal medication than CSI and PUI. GW was able to remove pulp tissue and calcifications. Moreover, its ability to remove hard-tissue debris and smear layer was better than that of CSI, and its ability to remove root canal obturation residues was lower or similar to that of PUI, and similar to that of CSI and EndoVac. Regarding root canal obturation of minimally instrumented molar canals, GW was associated with high-quality obturation. Clinically, the success rate of endodontic treatment using GW was 97.3%, and the short-term postoperative pain in the GW group was not different from CSI. Further research, mainly clinical, is needed to establish whether GW has any advantages over other available irrigation methods.

In vitro apical pressure created by 2 irrigation needles and a multisonic system in mandibular molars

  • Ronald Ordinola-Zapata;Joseph T. Crepps;Ana Arias;Fei Lin
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.14.1-14.7
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the apical pressure generated by 2 endodontic irrigation needles and the GentleWave system in mandibular molars. Materials and Methods: The mesial and distal root canals of 12 mandibular molars were irrigated with a 30-gauge close-end needle or with a 30-gauge open-end needle. Procedures were performed in the mesial and distal canals. The GentleWave procedure and irrigation at 1 mm from the apex in the distal roots using an open-end needle were used, respectively, as negative and positive controls. The apical pressure was measured using a data acquisition pressure setup. Apical pressure exerted by the different needles in the 2 different canal types was statistically compared using 2-way analysis of variance. Results: Significant differences were found in the apical pressure for both needles and the canal type. The lowest values were obtained with close-end needles and in mesial canals. Negative apical pressure values were obtained using GentleWave. Conclusions: The needle and the canal type influenced the apical pressure. The GentleWave procedure produced negative apical pressure.

The effect of glazing and aging on the surface properties of CAD/CAM resin blocks

  • Tekce, Neslihan;Fidan, Sinan;Tuncer, Safa;Kara, Dilan;Demirci, Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.50-57
    • /
    • 2018
  • PURPOSE. To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS AND METHODS. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad $S\ddot{a}ckingen$, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness ($R_a$ and $R_z$) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post- hoc test (P<.05). RESULTS. LAVA, VITA, and Cerasmart exhibited statistically similar $R_a$ and $R_z$ values for each group (P>.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher $R_a$ values than Group 2 (P<.05). Group 1 ($0.502R_a$), Group 2 ($0.384R_a$), and Group 3 ($0.431R_a$) exhibited statistically similar $R_a$ values for LAVA (P=.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart (P>.05). CONCLUSION. Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

수복재료에 대합되는 의치용 레진치의 마모저항성 비교 (COMPARISON OF WEAR RESISTANCE AMONG RESIN DENTURE TEETH OPPOSING VAR10US RESTORATIVE MATERIALS)

  • 이철영;정문규
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.313-327
    • /
    • 1999
  • The aim of this study was to compare wear resistance of resin denture teeth opposing various restorative materials. The wear resistance of conventional acrylic resin teeth(Trubyte Biotone) and three high-strength resin teeth(Bioform IPN, Endura, SR-Orthosit-PE) opposing different restorative materials(gold alloys, dental porcelain, composite resin) was compared. Wear tests were conducted with a sliding-induced wear testing apparatus which applied 100,000 strokes to the specimen in a mesio-distal direction under conditions of 100 stroke/min and constant loading of 1Kgf/tooth. Wear resistance of the resin denture teeth was evaluated by the following criteria : 1) wear depth, 2) weight loss, and 3) SEM observation. Results were as follows. 1. When opposed to gold alloys and composite resin, high-strength resin teeth showed superior wear resistance compared to acrylic resin teeth. But, in cases opposing dental porcelain, differences between the wear of the high-strength and acrylic resin teeth were not statistically significant (p<0.05). 2. When comparing wear resistance among high-strength resin teeth, opposing gold alloys, Endura was slightly more resistant and while in cases opposing dental porcelain, SR-Orthosit-PE was showed to be slightly resistant(p<0.05). 3. The wear of high-strength resin teeth was greater by 5 to 7 times when opposing porcelain and 2 to 3 times when opposing composite resin compared to gold alloys(p<0.05). 4. SEM observations of the wear surface showed that wear of resin teeth opposing gold alloys is a fatigue type of wear and wear of resin teeth opposing dental porcelain is fatigue and abrasion type of wear. Trubyte Biotone showed more severe fatigue type of wear than high-strength resin teeth. In conclusion, the use of dental porcelain should seriously be considered as restorative material in cases opposing resin denture teeth and improvement seems to be needed on resin teeth in the areas of wear resistance.

  • PDF

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.

Influence of different surface treatments on bond strength of novel CAD/CAM restorative materials to resin cement

  • Komurcuoglu, Meltem Bektas;Sagirkaya, Elcin;Tulga, Ayca
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.439-446
    • /
    • 2017
  • PURPOSE. To evaluate the effects of different surface treatments on the bond strength of novel CAD/CAM restorative materials to resin cement by four point bending test. MATERIALS AND METHODS. The CAD/CAM materials under investigation were e.max CAD, Mark II, Lava Ultimate, and Enamic. A total of 400 bar specimens ($4{\times}1.2{\times}12mm$) (n=10) milled from the CAD/CAM blocks underwent various pretreatments (no pretreatment (C), hydrofluoric acid (A), hydrofluoric acid + universal adhesive (Scotchbond) (AS), sandblasting (Sb), and sandblasting + universal adhesive (SbS)). The bars were luted end-to-end on the prepared surfaces with a dual curing adhesive resin cement (Variolink N, Ivoclar Vivadent) on the custom-made stainless steel mold. Ten test specimens for each treatment and material combination were performed with four point bending test method. Data were analyzed using ANOVA and Tukey's test. RESULTS. The surface treatment and type of CAD/CAM restorative material showed a significant effect on the four point bending strength (FPBS) (P<.001). For LDC, AS surface treatment showed the highest FPBS results ($100.31{\pm}10.7MPa$) and the lowest values were obtained in RNC ($23.63{\pm}9.0MPa$) for control group. SEM analyses showed that the surface topography of CAD/CAM restorative materials was modified after treatments. CONCLUSION. The surface treatment of sandblasting or HF acid etching in combination with a universal adhesive containing MDP can be suggested for the adhesive cementation of the novel CAD/CAM restorative materials.

치과용 Glass Polyalkenoate cement의 방사선 불투과성에 관한 비교 연구 (RADIOPACITY OF DENTAL GLASS POLYALKENOATE CEMENTS)

  • 임영일;엄정문;이정식;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.464-469
    • /
    • 1997
  • The radiopacity of glass ionomer cements is quite variable. The use of a poorly radiopaque material as a base under other restorative materials can mislead the dentist to a diagnosis of recurrent decay. This study investigates the radiopacity of these materials and proposes a minimal radiopacity under which a material should not be used as a base or liner. It is important to determine the radiopacity of glass ionomer dental materials so that the clinician can appreciate the type of restorative materials used when radiographically evaluation the possibility of recurrent dental caries. In this study, radiopacity of Vitrement and Chemfil was compared with that of Cavalite, Miracle mix and polycarboxylate cement. Tooth model of artificial cavity preparation for diagnosis of recurrent caries was omitted. Radiopacity of each material was measured using relatives between thickness and radiopacity of Aluminium step wedge. The results were as follows : 1. Radiopacity of Vitrement was some higher than enamel. 2. Chemfil, restorative glass ionomer, was less radiopaque than enamel. 3. In order of higher radiopacity than enamel, Miracle mix was highest and was followed by polycarboxylate cement, Cavalite and Vitremer. 4. Vitremer, the Glass Ionomer Cement, is useful to detection of recurrent caries, because it is slightly higher radiopaque than enamel. So, it is suitable for restorative material and luting cement.

  • PDF

공초점레이저주사현미경을 이용한 심미수복재와 상아질의 접착계면에 관한 연구 (A CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE INTERFACE BETWEEN TOOTH COLORED RESTORATIVE MATERIALS AND DENTIN)

  • 박병철;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.313-320
    • /
    • 2000
  • The purpose of this study was to evaluate on the interfacial morphology between dentin and restorative materials. In this in vitro study, the cavity wall restorated with 3 different kinds of tooth colored restorative materials [resin-modified Glass Ionomer cement (Fuji II LC), composite resin (Z-100), compomer (Dyract)]. The thirty extracted human molar teeth without caries and/or restorations are used. The experimental teeth were randomly divided into three groups of ten teeth each. In each group, Wedge shaped cavities (width: 3mm, length: 2mm, depth: 1.5mm) were prepared at the cementoenamel junction on buccal and lingual surfaces. The adhesive of composite resin were mixed with rhodamine B. Primer of composite resin, Prime & Bond 2.1 of Dyract and liquid of Fuji II LC were mixed with fluorescein. In group 1, the cavity wall was treatment with dentin conditioner, and then restorated with Fuji II LC. In group 2, the cavity wall was treatment with Prime & Bond 2.1 and then restorated with Dyract. In group 3, the cavity wall was etching with 10% maleic acid, applied with primer and bonding agent and then restorated with Z-100. The interface between dentin and restorative materials was observed by fluoresence imaging with a confocal laser scanning microscope. The results were as follows : 1. In Glass ionomer group, adaptation of resin modified Glass-ionomer restoration against cavity wall is tight, but the crack formed inside of restoration were observed. 2. In Dyract group, the penetration of resin tag is shorter and the width of hybrid layer is narrower than composite resin group. 3. In Z-100 group, primer penetrated deeply through dentinal tubule. Also bonding agent was penetrated along the primer, but the penetration length is shorter than primer part, and in 3-D image, the resin tag is conical shape and lateral branch is observed.

  • PDF