• Title/Summary/Keyword: restorative

Search Result 2,666, Processing Time 0.026 seconds

Antibacterial properties of composite resins incorporating silver and zinc oxide nanoparticles on Streptococcus mutans and Lactobacillus

  • Kasraei, Shahin;Sami, Lida;Hendi, Sareh;AliKhani, Mohammad-Yousef;Rezaei-Soufi, Loghman;Khamverdi, Zahra
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.109-114
    • /
    • 2014
  • Objectives: Recurrent caries was partly ascribed to lack of antibacterial properties in composite resin. Silver and zinc nanoparticles are considered to be broad-spectrum antibacterial agents. The aim of the present study was to evaluate the antibacterial properties of composite resins containing 1% silver and zinc-oxide nanoparticles on Streptococcus mutans and Lactobacillus. Materials and Methods: Ninety discoid tablets containing 0%, 1% nano-silver and 1% nano zinc-oxide particles were prepared from flowable composite resin (n = 30). The antibacterial properties of composite resin discs were evaluated by direct contact test. Diluted solutions of Streptococcus mutans (PTCC 1683) and Lactobacillus (PTCC 1643) were prepared. 0.01 mL of each bacterial species was separately placed on the discs. The discs were transferred to liquid culture media and were incubated at $37^{\circ}C$ for 8 hr. 0.01 mL of each solution was cultured on blood agar and the colonies were counted. Data was analyzed with Kruskall-Wallis and Mann-Whitney U tests. Results: Composites containing nano zinc-oxide particles or silver nanoparticles exhibited higher antibacterial activity against Streptococcus mutans and Lactobacillus compared to the control group (p < 0.05). The effect of zinc-oxide on Streptococcus mutans was significantly higher than that of silver (p < 0.05). There were no significant differences in the antibacterial activity against Lactobacillus between composites containing silver nanoparticles and those containing zinc-oxide nanoparticles. Conclusions: Composite resins containing silver or zinc-oxide nanoparticles exhibited antibacterial activity against Streptococcus mutans and Lactobacillus.

Microhybrid versus nanofill composite in combination with a three step etch and rinse adhesive in occlusal cavities: five year results

  • Tuncer, Safa;Demirci, Mustafa;Oztas, Evren;Tekce, Neslihan;Uysal, Omer
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.253-263
    • /
    • 2017
  • Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

INFLUENCE OF MICROHARDNESS AND FLUORIDE CONTENT OF TOOTH STRUCTURE BY FLUORIDE-CONTAINING RESTORATIVE MATERIALS (수복재에 함유된 불소가 치질의 미세경도와 불소 함유량에 미치는 영향)

  • Lee, Su-Jong;Cho, Young-Gon;Kim, Jong-Uk;Park, Byung-Cheul
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this study was to compare the microhardness and the fluoride content of enamel and dentin around fluoride- or non fluoride-containing restorations. Forty extracted human teeth were used and prepared cervical cavities on proximal surface. Experimental teeth were divided into five groups . Group 1 : Prime & Bond NT and Z100, Group 2 Prime & Bond NT and F2000, Group 3 : Scotchbond Multi-purpose and Z100, Group 4 : Scothcbond Multi-purpose and F2000, Group 5 : Fuji II LC. The cavities were filled with dentin adhesives and restorative materials. After each tooth was bisected, one half was tested microharaness and the other half was analyzed the fluoride at the enamel and dentin by an EPMA-WDX device. The results were as follows; 1. There was no statistical difference among the microhardness of enamel surface in all group. 2. The microhardness at dentin of $100{\;}\mu\textrm{m}$ point in Group 2 and $20{\;}\mu\textrm{m}$ point in Grocup 4 was lower than that of normal dentin (p>0.05). 3. There was no statistical difference among the fluoride content of enamel surface in all group. 4. The fluoride content at the dentin of $30{\;}\mu\textrm{m}$ point in Group 2 and 5 were higher than those at $100{\;}\mu\textrm{m}{\;}and{\;}200{\;}\mu\textrm{m}$ point in Group 2 and normal dentin (p<0.05). 5. At the dentin of $30{\;}\mu\textrm{m}$ point, Group 2 showed higher fluoride content than Group 1 and 3, and Group 5 showed higher fluoride content than other groups.

Comparative study of the radiopacity of resin cements used in aesthetic dentistry

  • Montes-Fariza, Raquel;Monterde-Hernandez, Manuel;Cabanillas-Casabella, Cristina;Pallares-Sabater, Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the radiopacity of 6 modern resin cements with that of human enamel and dentine using the Digora digital radiography system, to verify whether they meet the requirements of ANSI/ADA specification no. 27/1993 and the ISO 4049/2000 standard and assess whether their radiopacity is influenced by the thickness of the cement employed. MATERIALS AND METHODS. Three 3-thickness samples (0.5, 1 and 1.5 mm) were fabricated for each material. The individual cement samples were radiographed on the CCD sensor next to the aluminium wedge and the tooth samples. Five radiographs were made of each sample and therefore five readings of radiographic density were taken for each thickness of the materials. The radiopacity was measured in pixels using Digora 2.6 software. The calibration curve obtained from the mean values of each step of the wedge made it possible to obtain the equivalent in mm of aluminium for each mm of the luting material. RESULTS. With the exception of Variolink Veneer Medium Value 0, all the cements studied were more radiopaque than enamel and dentin (P<.05) and complied with the ISO and ANSI/ADA requirements (P<.001). The radiopacity of all the cements examined depended on their thickness: the thicker the material, the greater its radiopacity. CONCLUSION. All materials except Variolink Veneer Medium Value 0 yielded radiopacity values that complied with the recommendations of the ISO and ANSI/ADA. Variolink Veneer Medium Value 0 showed less radiopacity than enamel and dentin.

FULL COVERAGE RESTORATION OF PRIMARY ANTERIOR TEETH : A CASE REPORT (유전치의 전장피개수복 : 증례보고)

  • Hong, Kee-Sang;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.240-247
    • /
    • 1999
  • Primary anterior teeth requiring extensive restorative therapy due to caries, trauma or developmental defects can present a particularly challenging problem for the pediatric dentist. The ideal restorative technique would combine strength, durability esthetics and efficiency in placement. Couple these concerns with the technical difficulties of operating on children with behavior management problems, and the dentist is left with the difficult task of choosing from a variety of restorative options. Restorative modalities currently in use to treat primary anterior teeth include bonding with composite resin as in celluloid strip crowns, conventional stainless steel crowns, open-faced stainless steel crowns, commercially and chairside veneered stainless steel crowns and epoxy-coated stainless steel crowns. Each of these techniques presents technical, functional or esthetic compromises that complicate their efficient and effective usage. This is a report of the results obtained at the Department of Pediatric Dentistry, College of Dentistry Seoul National University, through the use of these various methods of treating primary anterior teeth.

  • PDF

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

An Experimental Study on the Durability Properties of Repair Mortar for Sewer Spread with Liquefied Antibiotic (액상 항균제를 도포한 하수시설용 단면복구재의 내구특성에 관한 실험적 연구)

  • Lee Dong-Heck;Jang Jae-bong;Na Chul-Sung;Cho Bong-Suk;Kim Jae-hwan;Kim Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.211-214
    • /
    • 2005
  • Recently, Deterioration of the concrete sewer concrete structures by biochemical corrosion has been issued and a development of the inhibition system of corrosion that has been demanded. The sulfuric acid may react with the hardened cement paste and originate expansive products which can induce swelling and breakless of concrete. Also, a sulphuric acid reacts with calcium hydroxide to from $CaSO_4\;\cdot\;2H_2O$. This reaction accounts for consumption of the calcium hydroxide present in hardened cement paste. In this study, To present from biochemical corrosion of the sewer repair mortar that was spread with liquefied antibiotic and then its experimental properties were experimentally investigated and to estimate the effect of absorbed condition of restorative mortar, the number of coating times and coating contents with antibiotic on the durability properties of restorative mortar spread with antibiotics. Also, testing items such as carbonation depth, choloride ion penetration depth and chemical resistance was tested to estimate the durability properties in third study. In results, the novellus bacillus inhabiting in sewer concrete structures was restrained by antibiotics developed in this study. And carbonation depth, choloride ion penetration depth and chemical resistance of restorative mortar spread with antibiotics was superior to that of plain mortar.

  • PDF