• 제목/요약/키워드: response modification factors

검색결과 111건 처리시간 0.023초

결합형 유한요소-경계요소 기법을 사용한 심해저용 압전형 유연성 쏘나 변환기의 시뮬레이션 (Simulation of a piezoelectric flextentional deep-water sonar transducer using a coupled FE-BEM)

  • 장순석;이제형;안흥구;최현호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.218-223
    • /
    • 1999
  • A piezoelectric flextentional deep-water sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with extern리 electrical excitation conditions as well as external acoustic pressure loading conditions. Different results are available such as steady-state frequency response for RX and TX, displacement modes, directivity patterns, back-scattering patterns, resonant frequencies, bandwidths, quality factors, transmitting voltage (TV) responses, input receiving sensitivity (RS) responses. White the present barrel-stave typed sonar transducer of the piezoelectric material is being simulated, the external surface of the transducer is modified in order to allow the same water pressure to be applied to the inner and the outer surfaces of the transducer. With this modification for deep-water application, the resonance frequency of the modified flextentional sonar transducer becomes much lower than that of the unmodified flextentional sonar transducer. The results of the present sonar transducer modelling are also compared with those of a commercial package such as ATILA.

  • PDF

토양.지하수오염원 분류체계 구축방안: 2. 분류체계 구축 및 속성자료 활용방안 (Building a Classification Scheme of Soil and Groundwater Contamination Sources in Korea: 2. Construction of Classification System and Applications of Attribute Data)

  • 안정이;신경희;황상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권6호
    • /
    • pp.122-127
    • /
    • 2010
  • Constructing the national inventory that can be used as a tool to identify and assess existing or potential contamination is necessary for efficiently managing the soil and groundwater contamination. In order to start this construction, the first step is how we define and classify potential contamination sources of soil and groundwater. After selecting the basic classification model of contamination sources from developed countries, we suggested the classification and list of the potential contamination sources of soil and groundwater which are appropriate for specific conditions of South Korea. In addition, we investigated several databases to confirm the existence of available data sources and then examined established attribute data through chemical accident response information system (CARIS) and water information system (WIS) in National Institute of Environmental Research and mine geographic information system (MGIS) in Mine Reclamation Corporation. All sorts of attribute data in the existing databases can be utilized as significant assessment factors for determining the management priority of potential contamination sources in the future. Therefore, it is required the expanded investigation of additional database sources and the continual modification so that the classification system of potential contamination sources can be improved.

Application of tuned liquid dampers in controlling the torsional vibration of high rise buildings

  • Ross, Andrew S.;El Damatty, Ashraf A.;El Ansary, Ayman M.
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.537-564
    • /
    • 2015
  • Excessive motions in buildings cause occupants to become uncomfortable and nervous. This is particularly detrimental to the tenants and ultimately the owner of the building, with respect to financial considerations. Serviceability issues, such as excessive accelerations and inter-story drifts, are more prevalent today due to advancements in the structural systems, strength of materials, and design practices. These factors allow buildings to be taller, lighter, and more flexible, thereby exacerbating the impact of dynamic responses. There is a growing need for innovative and effective techniques to reduce the serviceability responses of these tall buildings. The current study considers a case study of a real building to show the effectiveness and robustness of the TLD in reducing the coupled lateral-torsional motion of this high-rise building under wind loading. Three unique multi-modal TLD systems are designed specifically to mitigate the torsional response of the building. A procedure is developed to analyze a structure-TLD system using High Frequency Force Balance (HFFB) test data from the Boundary Layer Wind Tunnel Laboratory (BLWTL) at the University of Western Ontario. The effectiveness of the unique TLD systems is investigated. In addition, a parametric study is conducted to determine the robustness of the systems in reducing the serviceability responses. Three practical parameters are varied to investigate the robustness of the TLD system: the height of water inside the tanks, the amplitude modification factor, and the structural modal frequencies.

비정형 Diagrid System의 내진성능 평가 (Seismic Performance Evaluation of Freeform Diagrid System)

  • 고창균;주영규;김상대
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.189-198
    • /
    • 2011
  • 최근 건축물들이 미적인 아름다움을 추구하며 점차 비정형화 되어감에 따라 이를 실현시켜 주기 위한 새로운 구조시스템들이 개발되고 있다. Diagrid system은 외각에 배치 된 경사진 기둥을 통해 구조물의 중력하중과 횡력을 모두 저항하는 시스템으로 건물 내부에 기둥이 없어 비교적 평면 변화에 유리한 시스템이다. 하지만 현행의 내진설계 기준에는 이와 같은 새로운 구조시스템에 대한 내진성능계수가 명시되어 있지 않다. 이에 새로운 내진성능 평가 방법인 ATC-63이 제안되었다. 본 논문에서는 구조물의 비정형성을 고려해주기 위해 3D 비선형 해석 모델에 각각 작용하는 하중의 방향을 달리하며 ATC-63에서 제시하고 있는 절차에 따라 비정형 Diagrid system의 내진성능을 평가하였다.

N2 Method를 이용한 RC 중간모멘트 연성골조의 반응수정계수 및 내진성능 평가 (Estimation of R-factor and Seismic Performance for RC IMRFs using N2 Method)

  • 윤정배;이철호;최정욱;송진규
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.33-39
    • /
    • 2002
  • 반응수정계수는 구조물의 비탄성 거동을 설계에 반영하고 설계지진력 산정시 설계강도를 탄성범위 이내로 저감시키기 위한 목적으로 사용하고 있다. 그러나 설계코드에서 채택하고 있는 반응수정계수는 과거의 지진피해로부터 관찰된 보편적 구조성능에 기인한 경험치이므로, 주기에 따른 동적성능과 구조 시스템의 구성에 따른 내진성능을 정확히 대변하지 못하고 있다. 본 연구에서는 중간모멘트 연성골조를 대상으로 N2 Method를 이용하여 반응수정계수와 내진성능을 평가하였으며, 그 결과를 미국의 IBC 2000 코드와 비교하여 이론적 타당성을 검증하였다. 해석결과 코드에 제시된 반응수정계수와 잘 부합되는 것으로 나타났으나, 동일한 구조시스템의 경우에도 주기에 따라 비교적 큰 차이를 보였다. 성능목표에 따른 사용성 기준을 설정하여 IDI를 평가한 결과, 설계지진에 대한 성능목표가 건물에 대한 내진성능을 대변하기는 어려우며 PBD(Performance Based Design)에 의거한 합리적인 접근이 필요한 것으로 판단된다.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.

교량의 지진응답해석을 위한 말뚝기초의 등가 선형 강도행렬 (Equivalent Linear Stiffness Matrix of Pile Foundation for the Seismic Response Analysis of Bridges)

  • 박형기;조양희
    • 한국지진공학회논문집
    • /
    • 제5권3호
    • /
    • pp.1-8
    • /
    • 2001
  • 교량 구성요소의 설계지진력은 현행 국내 도로교설계기준에 의하면 설계지진을 가하여 얻어진 탄성지진력을 구조형식에 따른 응답수정계수로 나눔으로써 결정되어진다. 말뚝기초가 채택된 교량시스템의 탄성지진력의 크기는 말뚝기초의 모형화 방법에 따라 크게 달라질 수 있다. 이 논문에서는 근사적이고 실용적인 말뚝기초의 모형화 기법을 제시하였다. 이 모형화 기법에서는 말뚝기초의 강도를 횡방향으로 반복하중을 가진 현장시험으로 얻은 말뚝-지반의 상호작용이 고려된 지반반력-변위 곡선을 이용한 말뚝의 수평방향 강도와 탄성 축변형은 물론 선단지지력 및 주변마찰력을 고려한 말뚝의 수직방향 강도로 나타내는 것이다. 예제 교량의 해석을 수행하여 제시된 절차가 타당성있고 적용 가능한 교량의 지진응답해석용 말뚝기초의 모형화 기법임을 검증하였다.

  • PDF

저선량 방사선 노출에 대한 생물학적 지표로서 Glycophorin A 변이발현율 측정의 유용성 평가 (Assessment of the Glycophorin A Mutant Assay as a Biologic Marker for Low Dose Radiation Exposure)

  • 하미나;유근영;하성환;김동현;조수헌
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권2호
    • /
    • pp.165-173
    • /
    • 2000
  • Objectives : To assess the availability of the glycophorin A (GPA) assay to detect the biological effect of ionizing radiation in workers exposed to low-doses of radiation. Methods : Information on confounding factors, such as age and cigarette smoking was obtained on 144 nuclear power plant workers and 32 hospital workers, by a self-administered questionnaire. Information on physical exposure levels was obtained from the registries of radiation exposure monitoring and control at each facility. The GPA mutant assay was performed using the BR6 method with modification by using a FACScan flow cytometer. Results : As confounders, age and cigarette smoking habits showed increasing trends with GPA variants, but these were of no statistical significance. Hospital workers showed a higher frequency of the GPA variant than nuclear power plant workers in terms of the NO variant. Significant dose-response relationships were obtained from in simple and multiple linear regression models. The slope of the regression equation for nuclear power plant workers was much smaller than that of hospital workers. These findings suggest that there may be apparent dose-rate effects. Conclusion : In population exposed to chronic low-dose radiation, the GPA assay has a potential to be used as an effective biologic marker for assessing the bone marrow cumulative exposure dose.

  • PDF

Seismic evaluation of vertically irregular building frames with stiffness, strength, combined-stiffness-and-strength and mass irregularities

  • Nezhad, Moosa Ebrahimi;Poursha, Mehdi
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.353-373
    • /
    • 2015
  • In this paper, the effects of different types of irregularity along the height on the seismic responses of moment resisting frames are investigated using nonlinear dynamic analysis. Furthermore, the applicability of consecutive modal pushover (CMP) procedure for computing the seismic demands of vertically irregular frames is studied and the advantages and limitations of the procedure are elaborated. For this purpose, a special moment resisting steel frame of 10-storey height was selected as reference regular frame for which the effect of higher modes is important. Forty vertically irregular frames with stiffness, strength, combined-stiffness-and-strength and mass irregularities are created by applying two modification factors (MF=2 and 4) in four different locations along the height of the reference frame. Seismic demands of irregular frames are computed by using the nonlinear response history analysis (NL-RHA) and CMP procedure. Modal pushover analysis (MPA) method is also carried out for the sake of comparison. The effect of different types of irregularity along the height on the seismic demands of vertically irregular frames is investigated by studying the results obtained from the NL-RHA. To demonstrate the accuracy of the enhanced pushover analysis methods, the results derived from the CMP and MPA are compared with those obtained by benchmark solution, i.e., NL-RHA. The results show that the CMP and MPA methods can accurately compute the seismic demands of vertically irregular buildings. The methods may be, however, less accurate especially in estimating plastic hinge rotations for weak or weak-and-soft top and middle storeys of vertically irregular frames.

A Study on Grain Yield Response and Limitations of CERES-Barley Model According to Soil Types

  • Sang, Wan-Gyu;Kim, Jun-Hwan;Shin, Pyeong;Cho, Hyeoun-Suk;Seo, Myung-Chul;Lee, Geon-Hwi
    • 한국토양비료학회지
    • /
    • 제50권6호
    • /
    • pp.509-519
    • /
    • 2017
  • Crop simulation models are valuable tools for estimating crop yield, environmental factors and management practices. The objective of this study was to evaluate the effect of soil types on barley productivity using CERES (Crop Environment REsource Synthesis)-barley, cropping system model. So the behavior of the model under various soil types and climatic conditions was evaluated. The results of the sensitivity analysis in temperature, $CO_2$, and precipitation showed that soil types had a direct impact on the simulated yield of CERES-barley model. We found that barley yield in clay soils would be more sensitive to precipitation and $CO_2$ in comparison with temperature. And the model showed limited accuracy in simulating water and nitrogen stress index for soil types. In general, the barley grown on clay soils were less sensitive to water stress than those grown on sandy soils. Especially it was found that the CERES model underestimated the effect of water stress in high precipitation which led to overprediction of crop yield in clay soils. In order to solve these problems and successfully forecast grain yield, further studies on the modification of the water stress response of crops should be considered prior to use of the CERES-barley model for yield forecasting.