• Title/Summary/Keyword: response chart

Search Result 105, Processing Time 0.027 seconds

A Comparative Study of Density Compensation in Gamma-Gamma Log in PVC Casings between above and below Ground Water Tables (지하수면 상.하부 환경에서의 PVC 케이싱 이격보정 비교 연구)

  • Kim, Yeong-Hwa;Hwang, Byong-Chol;Park, Sung-Geun;Kim, Jong-Man
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.217-225
    • /
    • 2009
  • A series of model borehole experiments and analyses for density compensation were performed to achieve the effective density correction of gamma-gamma log obtained from PVC cased boreholes. A follow-up survey was made for clarifying the variation property of detector responses depending on casing types, the presence of borehole fluid, and the degree of separation between probe and borehole wall. A special emphasis was placed on the comparison of gamma responses obtained from above and below ground water tables. Finally, we could quantify the detector responses as a function of separation between the probe and borehole wall, construct standoff compensation charts, and the limitations of the compensation have been discussed for the environments of both above and below ground water tables.

Robust Air-to-fuel Ratio Control Algorithm of Passenger Car Diesel Engines Using Quantitative Feedback Theory (QFT 기법을 이용한 승용디젤엔진 공연비 제어 알고리즘 설계 연구)

  • Park, Inseok;Hong, Seungwoo;Shin, Jaewook;Sunwoo, Myoungho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.88-97
    • /
    • 2013
  • This paper presents a robust air-to-fuel ratio (AFR) control algorithm for managing exhaust gas recirculation (EGR) systems. In order to handle production tolerance, deterioration and parameter-varying characteristics of the EGR system, quantitative feedback theory (QFT) is applied for designing the robust AFR control algorithm. A plant model of EGR system is approximated by the first order transfer function plus time-delay (FOPTD) model. EGR valve position and AFR of exhaust gas are used as input/output variables of the plant model. Through engine experiments, parameter uncertainty of the plant model is identified in a fixed engine operating point. Requirement specifications of robust stability and reference tracking performance are defined and these are fulfilled by the following steps: during loop shaping process, a PID controller is designed by using a nominal loop transmission function represented on Nichols chart. Then, the frequency response of closed-loop transfer function is used for designing a prefilter. It is validated that the proposed QFT-based AFR control algorithm successfully satisfy the requirements through experiments of various engine operating points.

Automatic identification of ARPA radar tracking vessels by CCTV camera system (CCTV 카메라 시스템에 의한 ARPA 레이더 추적선박의 자동식별)

  • Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.45 no.3
    • /
    • pp.177-187
    • /
    • 2009
  • This paper describes a automatic video surveillance system(AVSS) with long range and 360$^{\circ}$ coverage that is automatically rotated in an elevation over azimuth mode in response to the TTM(tracked target message) signal of vessels tracked by ARPA(automatic radar plotting aids) radar. This AVSS that is a video security and tracking system supported by ARPA radar, CCTV(closed-circuit television) camera system and other sensors to automatically identify and track, detect the potential dangerous situations such as collision accidents at sea and berthing/deberthing accidents in harbor, can be used in monitoring the illegal fishing vessels in inshore and offshore fishing ground, and in more improving the security and safety of domestic fishing vessels in EEZ(exclusive economic zone) area. The movement of the target vessel chosen by the ARPA radar operator in the AVSS can be automatically tracked by a CCTV camera system interfaced to the ECDIS(electronic chart display and information system) with the special functions such as graphic presentation of CCTV image, camera position, camera azimuth and angle of view on the ENC, automatic and manual controls of pan and tilt angles for CCTV system, and the capability that can replay and record continuously all information of a selected target. The test results showed that the AVSS developed experimentally in this study can be used as an extra navigation aid for the operator on the bridge under the confusing traffic situations, to improve the detection efficiency of small targets in sea clutter, to enhance greatly an operator s ability to identify visually vessels tracked by ARPA radar and to provide a recorded history for reference or evidentiary purposes in EEZ area.

Handling Deflection Limit in Open-Loop-Onset-Point PIO Analysis (Open-Loop-Onset-Point PIO 해석의 변위한계)

  • Park, Sang-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2010
  • A new treatment is proposed to handle a deflection limit in the open-loop-onset-point (OLOP), which is commonly used in the prediction of pilot in-the-loop oscillation (PIO) due to a rate saturation. The new approach is motivated by the frequency response of a stand-alone actuator in that, unlike the suggestion by the original OLOP procedure, the rate limit onset is not delayed to a higher frequency by a deflection limit. Indeed, if a feedback control loop is closed, the rate limit onset can be shifted to a lower frequency since the controller tends to react with larger commands when deflection limited. The amplitude of the command at this onset frequency is combined with the deflection limit to estimate the associated gain reduction in the open-loop-onset-point in the final step of the OLOP process. The comparison of the new approach with the previous method reveals that an inaccurate optimism which can occur in the previous method is corrected by the proposed treatment.

Comprehensive Bioinformation Analysis of the MRNA Profile of Fascin Knockdown in Esophageal Squamous Cell Carcinoma

  • Wu, Bing-Li;Luo, Lie-Wei;Li, Chun-Quan;Xie, Jian-Jun;Du, Ze-Peng;Wu, Jian-Yi;Zhang, Pi-Xian;Xu, Li-Yan;Li, En-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7221-7227
    • /
    • 2013
  • Background: Fascin, an actin-bundling protein forming actin bundles including filopodia and stress fibers, is overexpressed in multiple human epithelial cancers including esophageal squamous cell carcinoma (ESCC). Previously we conducted a microarray experiment to analyze fascin knockdown by RNAi in ESCC. Method: In this study, the differentially expressed genes from mRNA expression profilomg of fascin knockdown were analyzed by multiple bioinformatics methods for a comprehensive understanding of the role of fascin. Results: Gene Ontology enrichment found terms associated with cytoskeleton organization, including cell adhesion, actin filament binding and actin cytoskeleton, which might be related to fascin function. Except GO categories, the differentially expressed genes were annotated by 45 functional categories from the Functional Annotation Chart of DAVID. Subpathway analysis showed thirty-nine pathways were disturbed by the differentially expressed genes, providing more detailed information than traditional pathway enrichment analysis. Two subpathways derivated from regulation of the actin cytoskeleton were shown. Promoter analysis results indicated distinguishing sequence patterns and transcription factors in response to the co-expression of downregulated or upregulated differentially expressed genes. MNB1A, c-ETS, GATA2 and Prrx2 potentially regulate the transcription of the downregulated gene set, while Arnt-Ahr, ZNF42, Ubx and TCF11-MafG might co-regulate the upregulated genes. Conclusions: This multiple bioinformatic analysis helps provide a comprehensive understanding of the roles of fascin after its knockdown in ESCC.

Validation of a Modified Early Warning Score to Predict ICU Transfer for Patients with Severe Sepsis or Septic Shock on General Wards (일반병동 내 중증 패혈증 또는 패혈성 쇼크 환자의 중환자실 전동 예측에 대한 수정조기경고점수(Modified Early Warning Score)의 타당성)

  • Lee, Ju Ry;Choi, Hye Ran
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.219-227
    • /
    • 2014
  • Purpose: To assess whether the Modified Early Warning Score (MEWS) predicts the need for intensive care unit (ICU) transfer for patients with severe sepsis or septic shock admitted to general wards. Methods: A retrospective chart review of 100 general ward patients with severe sepsis or septic shock was implemented. Clinical information and MEWS according to point of time between ICU group and general ward group were reviewed. Data were analyzed using multivariate logistic regression and the area under the receiver operating characteristic curves with SPSS/WIN 18.0 program. Results: Thirty-eight ICU patients and sixty-two general ward patients were included. In multivariate logistic regression, MEWS (odds ratio [OR] 2.02, 95% confidence interval [CI] 1.43-2.85), lactic acid (OR 1.83, 95% CI 1.22-2.73) and diastolic blood pressure (OR 0.89, 95% CI 0.80-1.00) were predictive of ICU transfer. The sensitivity and the specificity of MEWS used with cut-off value of six were 89.5% and 67.7% for ICU transfer. Conclusion: MEWS is an effective predictor of ICU transfer. A clinical algorithm could be created to respond to high MEWS and intervene with appropriate changes in clinical management.

An Analysis of Bias-Dependent S11-Parameter in Multi-Finger MOSFETs (Multi-Finger MOSFET의 바이어스 종속 S11-파라미터 분석)

  • Ahn, Jahyun;Lee, Seonghearn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.15-19
    • /
    • 2016
  • The gate bias dependence of kink phenomenon with a large deviation from the resistance circle in Smith chart is observed in the frequency response of $S_{11}$-parameter for large multi-finger RF MOSFETs. For the first time, this bias dependence is analyzed by measuring magnitude and phase of $S_{11}$-parameter, input resistance and input capacitance. As a result, $V_{gs}$ dependent $S_{11}$-parameter is largely changed by the magnitude of input capacitance as well as dominant pole and zero frequencies of input resistance. At $V_{gs}=0V$, the kink phenomenon occurs in the high frequency region because of very small phase difference of $S_{11}$-parameter and high pole frequency of input resistance. However, the kink phenomenon at higher $V_{gs}$ is generated in the low frequency region owing to large phase difference and low pole frequency.

Structural health monitoring of a high-speed railway bridge: five years review and lessons learned

  • Ding, Youliang;Ren, Pu;Zhao, Hanwei;Miao, Changqing
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.695-703
    • /
    • 2018
  • Based on monitoring data collected from the Nanjing Dashengguan Bridge over the last five years, this paper systematically investigates the effects of temperature field and train loadings on the structural responses of this long-span high-speed railway bridge, and establishes the early warning thresholds for various structural responses. Then, some lessons drawn from the structural health monitoring system of this bridge are summarized. The main context includes: (1) Polynomial regression models are established for monitoring temperature effects on modal frequencies of the main girder and hangers, longitudinal displacements of the bearings, and static strains of the truss members; (2) The correlation between structural vibration accelerations and train speeds is investigated, focusing on the resonance characteristics of the bridge at the specific train speeds; (3) With regard to various static and dynamic responses of the bridge, early warning thresholds are established by using mean control chart analysis and probabilistic analysis; (4) Two lessons are drawn from the experiences in the bridge operation, which involves the lacks of the health monitoring for telescopic devices on the beam-end and bolt fractures in key members of the main truss.

Reconstruction of Ankle and Heel Defects with Peroneal Artery Perforator-Based Pedicled Flaps

  • Ahn, Deok Ki;Lew, Dae Hyun;Roh, Tai Suk;Lee, Won Jai
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.619-625
    • /
    • 2015
  • Background The reconstruction of ankle and heel defects remains a significant problem for plastic surgeons. The following options exist for reconstructing such defects: local random flaps, reverse flow island flaps, and free flaps. However, each of these methods has certain drawbacks. Peroneal artery perforators have many advantages; in particular, they are predictable and reliable for ankle and heel reconstructions. In this study, we report our clinical experience with peroneal artery perforator-based pedicled flaps in ankle and heel reconstructions. Methods From July 2005 to October 2012, 12 patients underwent the reconstruction of soft tissue defects in the ankle and heel using a peroneal artery perforator-based pedicled flap. These 12 cases were classified according to the anatomical area involved. The cause of the wound, comorbidities, flap size, operative results, and complications were analyzed through retrospective chart review. Results The mean age of the patients was 52.4 years. The size of the flaps ranged from $5{\times}4$ to $20{\times}8cm^2$. The defects were classified into two groups based on whether they occurred in the Achilles tendon (n=9) or heel pad (n=3). In all 12 patients, complete flap survival was achieved without significant complications; however, two patients experienced minor wound dehiscence. Nevertheless, these wounds healed in response to subsequent debridement and conservative management. No patient had any functional deficits of the lower extremities. Conclusions Peroneal artery perforator-based pedicled flaps were found to be a useful option for the reconstruction of soft tissue defects of the ankle and heel.

Modeling of a linear GMR Isolator Utilizing Spin Valves (스핀밸브를 이용한 선형 GMR 아이솔레이터의 모델링)

  • Park, S.;Jo, S.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.232-235
    • /
    • 2004
  • Linear GMR isolator which is profitable for transmitting analog signal was modeled and the output voltage and current in relation to the input current were investigated. GMR isolator modeling was divided into two parts, namely magnetic and electric parts. The flow chart of the modeling was drawn in which the MR curve of the spin valves were incorporated to obtain the electrical voltage output. For magnetic modeling, 3-dimensional model of planar coil was analyzed by FEM method to obtain the magnetic field strength corresponding to the input current. Coil efficiency of the planar coil having magnetic core layer was shown to have about 1.5 times larger than that of the coil without the magnetic core layer. The feedback coil current(output current) corresponding to the input coil current was calculated to be within ${\pm}$0.25 mA of the linear fitting function of I$\_$out/= I$\_$in/-5 mA. Also, the response time and output waveforms were obtained when the coil current was a rectangular waveform. The rise time and fall time was 6 ${\mu}\textrm{s}$, respectively when the slew rate of the op-amp was 0.3 V/${\mu}\textrm{s}$.