Heart Axis Rotation Due to Exercise

  • Lee, Tae-Jun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.4 no.1
    • /
    • pp.1-18
    • /
    • 1971
  • Eleven nonathletes and eleven athletes were exercised on a standardised Harvard step test, and the average rate of change in QRS amplitude in lead III of the electocardiogram associated with heart rotation and the average change in rate of heart beat were observed. 1. After the Harvard step exercise, the average rate of change in QRS amplitude in lead III of both groups increased. This was due to the clockwise rotation of the heart and was associated with respiratory movement. The diaphragm was inferred to remain for a while in a relatively more inspiratory position. 2. After the Halved step exercise, a high correlation between the recovery of the average rate of change in QRS amplitude in lead III and the average change in rate of heart beat was observed in the athletic group. 3. In the nonathletic group there was no significant correlation between the average rate of QRS amplitude change and the average rate of change of heart beat. 4. Athletes were assumed to be trained to ventilate quickly at their maximum ability, using deep descending movements of the diaphragm and other respiratory musclature. Consequently, the average in rate of heart beat also recovered quickly. 5. Nonathletes were inferred not to have been trained to adjust quickly to ventilate so efficiently with their diaphragm movement and other respiratory musculature, and are characterised by their longer time to complete recovery.

  • PDF

Filtration Performance Evaluation of Various Respiratory Face Masks Against Sub-Micron Particles (다양한 호흡기 보호용 면체 마스크의 서브 마이크론 입자에 대한 여과 성능 평가)

  • Zainul Alim Ali Murtadlo;Cho Hee-Joo;Park Hyun-Seol
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Respiratory face masks are protective facepieces that are designed to filter inhaled air. They are easy-to-use devices that can protect the wearer against various hazardous particles in the air. Respiratory face masks also prevent the spread of viruses and bacteria-containing droplets that are released from the coughing or sneezing of the infected people. During the COVID-19 pandemic, various types of face masks have circulated on the market. Their ability to filter sub-micron particles, which are the sizes of harmful particulate matter and airborne viruses, needs to be investigated. Their breathability, the easiness of breath through the mask, also needs to be considered. In this study, wwe evaluated the performance of filters used for different types of face masks certified by different standards including Korean (KF94, KF80, KF-AD), USA (N95), and Chinese (KN95) standards. We also tested the filters of nanofiber masks and surgical masks for which there are no standards for filtration test. The N95 mask filters showed the highest quality factor for capturing virus-sized particles. The other types of mask filters have acceptable performance except for nanofiber mask filters whose performance is very low.

DILD (diffuse infiltrative lung disease); Radiologic Diagnostic Approach According to High-Resolution CT Pattern (미만성 침윤성 폐질환; 고해상 전산화 단층촬영상 병변의 유형에 따른 방사선학적 진단접근)

  • Lee, Ki-Nam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.111-119
    • /
    • 2005
  • The introduction of high-resolution CT (HRCT) in recent years has improved the ability of radiologists to detect and characterize the diffuse infiltrative lung disease (DILD). The detection and diagnosis of diffuse lung disease using HRCT are based on the recognition of specific abnormal findings. In this article, pattern recognition of HRCT findings is reviewed in the differential diagnosis of diffuse infiltrative lung disease. In general, HRCT findings of lung disease can be classified into four categories based on their appearances. These categories consist of (1) nodules and nodular opacities, (2) linear and reticular opacities, (3) increased lung opacity, and (4) decreased lung opacity, including cystic lesions.

Production of Phagocyte Activating Supernatants by Olive Flounder (Paralichthys olivaceus) Leucocytes Stimulated with Genomic DNA of Escherichia coli

  • Lee Chan Hwei;Kim Dong Soo;Kim Ki Hong
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.4
    • /
    • pp.258-262
    • /
    • 2002
  • Effects of Escherichia coli genomic DNA on the production of phagocyte activating supernatants by the head kidney leucocytes isolated from olive flounder (Paralichthys olivaceus) were investigated. Phagocyte activating activity of the supernatants was estimated by. measuring reactive oxygen species (ROS) production in target head kidney phagocytes. All supernatants from olive flounder head kidney leucocytes-stimulated with E. coli DNA induced significantly (P<0.01) higher ROS production from target pagocytes than the unstimulated control supernatant. Maximum enhancement of chemiluminescent response was observed $5.0-10.0{\mu}g\;mL^{-1}$ of bacterial DNA while the increment ability was decreased significantly (P<0.01) at the concentration of $20.0{\mu}mL^{-1}$. The results demonstrate that olive flounder head-kidney leucocytes stimulated with bacterial DNA release a soluble phagocyte activating cytokines capable of enhancing the respiratory burst activity from target phagocytes.

A Study for Application of Standard and Performance Test According to Purpose and Subject of Respiratory Medical Device (호흡보조의료기기의 사용목적 및 대상에 따른 규격적용 방안 및 성능에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.215-221
    • /
    • 2019
  • The respiratory medical device is a medical device that delivers optimal oxygen or a certain amount of humidification to a patient by delivering artificial respiration to a patient through a machine when the patient has lost the ability to breathe spontaneously. These include respirators for use in chronic obstructive pulmonary disease and anesthesia or emergency situations, and positive airway pressure devices for treating sleep apnea, and as the population of COPD (chronic obstructive pulmonary disease) and elderly people worldwide surge, the market for the respiratory medical devices it is getting bigger. As the demand for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, the boundaries between the items are blurred due to the purpose, intended use, and method of use overlapping similar items in a respiratory medical device. In addition, for both airway pressure devices, there is a problem that the ventilator standard is applied because the reference standard has not been established. Therefore, in this study, we propose clear classification criteria for the respiratory medical devices according to the purpose, intended use, and method of use and provide safety and performance evaluation guidelines for those items to help quality control of the medical devices. And to contribute to the rapid regulating and improvement of public health. This study investigated the safety and performance test methods through the principles of the respiratory medical device, national and international standards, domestic and international licensing status, and related literature surveys. The results of this study are derived from the safety and performance test items in the individual ventilator(ISO 80601-2-72), the International Standard for positive airway pressure device (ISO 80601-2-70), The safety and performance of humidifiers (ISO 80601-2-74) and the safety evaluation items related to home healthcare environment (IEC 60601-1-11), In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers and importers, certified test inspection institutions, academia, etc., the final guidelines were established through revision and supplementation. Therefore, in this study, we propose guidelines for evaluating the safety and performance of the respiratory medical device in accordance with growing technology development.

Parallel Network Model of Abnormal Respiratory Sound Classification with Stacking Ensemble

  • Nam, Myung-woo;Choi, Young-Jin;Choi, Hoe-Ryeon;Lee, Hong-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.11
    • /
    • pp.21-31
    • /
    • 2021
  • As the COVID-19 pandemic rapidly changes healthcare around the globe, the need for smart healthcare that allows for remote diagnosis is increasing. The current classification of respiratory diseases cost high and requires a face-to-face visit with a skilled medical professional, thus the pandemic significantly hinders monitoring and early diagnosis. Therefore, the ability to accurately classify and diagnose respiratory sound using deep learning-based AI models is essential to modern medicine as a remote alternative to the current stethoscope. In this study, we propose a deep learning-based respiratory sound classification model using data collected from medical experts. The sound data were preprocessed with BandPassFilter, and the relevant respiratory audio features were extracted with Log-Mel Spectrogram and Mel Frequency Cepstral Coefficient (MFCC). Subsequently, a Parallel CNN network model was trained on these two inputs using stacking ensemble techniques combined with various machine learning classifiers to efficiently classify and detect abnormal respiratory sounds with high accuracy. The model proposed in this paper classified abnormal respiratory sounds with an accuracy of 96.9%, which is approximately 6.1% higher than the classification accuracy of baseline model.

The improve of hemiplegic patients functional ambulation profile by forceful respiratory exercise (노력성 호흡운동을 통한 편마비환자의 기능적 보행지수 개선)

  • Kim Byung-jo;Bae Sung-soo;Hwang-bo Gak
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.32-48
    • /
    • 2004
  • The purpose of this study was to evaluate the change of functional ambulation profile(FAP) and temporal-spatial gait parameters in hemiplegic patient by forceful respiratory exercise. 28 Hemiplegic patients due to stroke was randomized in 3 groups, forceful expiratory training(FET), forceful inspiratory training(FIT) and control group. In the experimental groups, ordinary physical therapy with forceful expiratory training and forceful inspiratory training for 20 minutes duration 3 times per week for 6 weeks were respectively performed. In the control group, only ordinary physical therapy was done. FAP and temporal-spatial gait parameters was measured at before and after experiments. The results of this experimental study were as follows : 1. In comparison of FAP before and after experiment, the FAP was significantly increased in the FET and FIT group (p<.01). In comparison of difference of FAP among 3 groups, there was the significant difference between the FIT group and the control group (p<.05). 2. The results of temporal-spatial gait parameters are as follows : 1) In comparison of gait velocity before and after experiment, the gait velocity was significantly increased in the FET and FIT group (p<.05). In comparison of difference of the gait velocity among 3 groups, there was the significantly difference between the FIT group and the control group (p<.05). 2) In comparison of gait cadence before and after experiment, the gait cadence was significantly increased in FIT group (p<.05). In comparison of the difference of the gait cadence among 3 groups, there was no significant difference between the FIT group and the control group (p>.05). Based on these results, it is concluded that the forced respiratory exercise program for 6 weeks can be improve the FAP and temporal-spatial gait parameters in hemiplegic patients. Therefore, the forced respiratory exercise is useful to improve the walking ability in hemiplegic patients.

  • PDF

Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology

  • Kim, Chul Hang;Choi, Hoon Sik;Kang, Ki Mun;Jeong, Bae Kwon;Jeong, Hojin;Ha, In Bong;Song, Jin Ho
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.8-15
    • /
    • 2022
  • Background: We developed a machine vision technology program that tracks patients' real-time breathing and automatically analyzes their breathing patterns. Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance. Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers. Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient's breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology.

Immunostaining patterns reveal potential morphogenetic role of Toll-like receptors 4 and 7 in the development of mouse respiratory system, liver and pancreas

  • Michele Sommariva;Marco Busnelli;Elena Menegola;Francesca Di Renzo;Serena Indino;Alessandra Menon;Isabella Barajon;Francesca Arnaboldi
    • Anatomy and Cell Biology
    • /
    • v.56 no.2
    • /
    • pp.228-235
    • /
    • 2023
  • Toll-like receptors (TLRs) are the mammalian ortholog of Drosophila melanogaster protein Toll, originally identified for its involvement in embryonic development. In mammals, TLRs are mainly known for their ability to recognize pathogen- or damage-associated molecular patterns and, consequently, to initiate the immune response. However, it is becoming clear that TLRs can play a role also in mammal embryo development. We have previously described TLR4 and TLR7 expression in developing mouse peripheral nervous system and gastrointestinal tract. In the present study, we extended the investigation of TLR4 and TLR7 to the respiratory system and to the two main accessory organs of the digestive system, the liver and pancreas. TLR4 and TLR7 immunostaining was performed on mouse conceptuses collected at different stages, from E12 to E18. TLR4 and TLR7 immunoreactivity was evident in the embryo pancreas and liver at E12, while, in the respiratory apparatus, appeared at E14 and E17, respectively. Although further studies are required to elucidate the specific role of these TLRs in embryo development, the differential spatiotemporal TLR4 and TLR7 appearance may suggest that TLR expression in developing embryos is highly regulated for a possible their direct involvement in the formation of the organs and in the acquisition of immune-related features in preparation for the birth.

The Use of Graphic Monitoring during Mechanical Ventilation (기계적 환기기 사용중 그래픽 모니터링의 활용)

  • Son, Dong-Woo
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Graphic monitoring assists the clinician at the bedside in several ways. It can be helpful in fine-tuning or adjusting ventilator parameters. Graphic monitoring may help to determine the patient's response to pharmacologic agents. The clinician also has the ability to trend monitored events over a prolonged period of time. The neonatal patient's self respiration, synchrony to ventilator and respiratory efforts can be well recognized with graphic monitoring. Of all, it may enable detection of complications before they become clinically apparent. This article introduces the basics of real-time graphics.