Acknowledgement
This research was supported by a grant from the Institute of Health Sciences (No. IHS GNU-2018-02).
References
- Chen QS, Weinhous MS, Deibel FC, Ciezki JP, Macklis RM. Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. Med Phys. 2001;28(9):1850-1856. https://doi.org/10.1118/1.1398037
- Vedam SS, Kini VR, Keall PJ, Ramakrishnan V, Mostafavi H, Mohan R. Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. Med Phys. 2003;30(4):505-513. https://doi.org/10.1118/1.1558675
- Webb S. Motion effects in (intensity modulated) radiation therapy: a review. Phys Med Biol. 2006;51(13):R403-425. https://doi.org/10.1088/0031-9155/51/13/R23
- Shirato H, Shimizu S, Kitamura K, Nishioka T, Kagei K, Hashimoto S, et al. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. Int J Radiat Oncol Biol Phys. 2000;48(2):435-442. https://doi.org/10.1016/S0360-3016(00)00625-8
- Murphy MJ. Tracking moving organs in real time. Semin Radiat Oncol. 2004;14(1):91-100. https://doi.org/10.1053/j.semradonc.2003.10.005
- Gagel B, Demirel C, Kientopf A, Pinkawa M, Piroth M, Stanzel S, et al. Active breathing control (ABC): determination and reduction of breathing-induced organ motion in the chest. Int J Radiat Oncol Biol Phys. 2007;67(3):742-749. https://doi.org/10.1016/j.ijrobp.2006.09.052
- Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76. Med Phys. 2006;33(10):3874-3900. https://doi.org/10.1118/1.2349696
- Neicu T, Berbeco R, Wolfgang J, Jiang SB. Synchronized moving aperture radiation therapy (SMART): improvement of breathing pattern reproducibility using respiratory coaching. Phys Med Biol. 2006;51(3):617-636. https://doi.org/10.1088/0031-9155/51/3/010
- Prunaretty J, Boisselier P, Ailleres N, Riou O, Simeon S, Bedos L, et al. Tracking, gating, free-breathing, which technique to use for lung stereotactic treatments? A dosimetric comparison. Rep Pract Oncol Radiother. 2019;24(1):97-104. https://doi.org/10.1016/j.rpor.2018.11.003
- Suramo I, Paivansalo M, Myllyla V. Cranio-caudal movements of the liver, pancreas and kidneys in respiration. Acta Radiol Diagn (Stockh). 1984;25(2):129-131. https://doi.org/10.1177/028418518402500208
- Mageras GS, Pevsner A, Yorke ED, Rosenzweig KE, Ford EC, Hertanto A, et al. Measurement of lung tumor motion using respiration-correlated CT. Int J Radiat Oncol Biol Phys. 2004;60(3):933-941. https://doi.org/10.1016/S0360-3016(04)01078-8
- Shimizu S, Shirato H, Ogura S, Akita-Dosaka H, Kitamura K, Nishioka T, et al. Detection of lung tumor movement in real-time tumor-tracking radiotherapy. Int J Radiat Oncol Biol Phys. 2001;51(2):304-310. https://doi.org/10.1016/S0360-3016(01)01641-8
- Shi C, Tang X, Chan M. Evaluation of the new respiratory gating system. Precis Radiat Oncol. 2017;1(4):127-133. https://doi.org/10.1002/pro6.34
- Moore D. Guidelines for using the ABC system on the Elekta for respiratory gating treatment. Cancer Ther Oncol Int J. 2018:9(3):61-71.
- Li XA, Stepaniak C, Gore E. Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system. Med Phys. 2006;33(1):145-154. https://doi.org/10.1118/1.2147743
- Marks MK, South M, Carter BG. Measurement of respiratory rate and timing using a nasal thermocouple. J Clin Monit. 1995;11(3):159-164. https://doi.org/10.1007/BF01617716
- Storck K, Karlsson M, Ask P, Loyd D. Heat transfer evaluation of the nasal thermistor technique. IEEE Trans Biomed Eng. 1996;43(12):1187-1191. https://doi.org/10.1109/10.544342
- Sharma G, Sood S, Gaba GS, Gupta N. Image recognition system using geometric matching and contour detection. Int J Comput Appl. 2012;51(17):48-53. https://doi.org/10.5120/8138-1905
- Yoshitake T, Nakamura K, Shioyama Y, Nomoto S, Ohga S, Toba T, et al. Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: system development and feasibility. Radiat Med. 2008;26(1):50-55. https://doi.org/10.1007/s11604-007-0189-4
- Yoshitake T, Shioyama Y, Nakamura K, Ohga S, Nonoshita T, Ohnishi K, et al. A clinical evaluation of visual feedback-guided breath-hold reproducibility of tumor location. Phys Med Biol. 2009;54(23):7171-7182. https://doi.org/10.1088/0031-9155/54/23/009
- Stock M, Kontrisova K, Dieckmann K, Bogner J, Poetter R, Georg D. Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking. Med Phys. 2006;33(8):2868-2877. https://doi.org/10.1118/1.2219775
- George R, Chung TD, Vedam SS, Ramakrishnan V, Mohan R, Weiss E, et al. Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. Int J Radiat Oncol Biol Phys. 2006;65(3):924-933. https://doi.org/10.1016/j.ijrobp.2006.02.035
- He P, Li Q, Liu X, Dai Z, Zhao T, Fu T, et al. Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery. Med Phys. 2014;41(11):111708. https://doi.org/10.1118/1.4897391
- Linthout N, Bral S, Van de Vondel I, Verellen D, Tournel K, Gevaert T, et al. Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback. Radiother Oncol. 2009;91(3):330-335. https://doi.org/10.1016/j.radonc.2009.03.019
- Nelson C, Starkschall G, Balter P, Fitzpatrick MJ, Antolak JA, Tolani N, et al. Respiration-correlated treatment delivery using feedback-guided breath hold: a technical study. Med Phys. 2005;32(1):175-181. https://doi.org/10.1118/1.1836332