• Title/Summary/Keyword: respirator

Search Result 116, Processing Time 0.032 seconds

Mobility and Thermal Comfort Assessment of Personal Protective Equipment for Female Healthcare Workers: Impact of Protective Levels and Body Mass Index (감염병 대응 개인보호복의 동작성 및 열적 쾌적성: 보호 수준 및 여성 착용자 체격의 영향)

  • Do-Hee Kim;Youngmin Jun;Ho-Joon Lee;Gyeongri Kang;Cho-Eun Lee;Joo-Young Lee
    • Fashion & Textile Research Journal
    • /
    • v.26 no.1
    • /
    • pp.123-136
    • /
    • 2024
  • This study aimed to assess the mobility and thermal comfort of personal protective equipment (PPE) among female healthcare workers, taking into account wearers' physique and PPE protection levels. A total of 16 participants (age: 26.3 ± 8.3 y, height: 161.5 ± 7.3 cm, body weight: 57.1 ± 11.0 kg, BMI: 21.9 ± 3.6), representing diverse body types, underwent four PPE conditions: L (Low_Plastic gown ensemble), M (Medium_Tyvek 400), H (High_Tyvek 800J with Powered Air Purifying Respirator [PAPR]), and E (Extremely high_Tychem 2000 with PAPR, Bib apron, and Chemical-resistant gloves). The mobility protocol consisted of 10 different tasks in addition to donning and doffing. The 10 tasks were repeated twice at an air temperature of 24.3 ± 0.1℃, 59±4%RH. Findings revealed a disproportionate relationship between PPE protection and wearer discomfort. Significant differences in clothing microclimate and total sweat rate were observed between the lowest (L) and highest (E) protection levels (p < 0.01), while distinctions among medium levels were inconclusive. Subjective evaluations favored conditions H and L over M and E (p < 0.05), indicating reduced heat, and humidity, increased comfort, and lower exertion. Instances of mobility discomfort, specially in the small body type group, underscored the need for a suitable PPE size system for Korean adult female medical workers. Furthermore, enhancements in gloves, shoe cover, and PAPR hood designs are essential for improving ease of movement and preventing hindrance.

Development of Korean Representative Headforms for the Total Inward Leakage Testing on Filtering Facepiece Respirators

  • Ah Lam Lee;Xin Cui;Hayoung Jung;Hee Eun Kim;Eun Jin Jeon;Hyungjin Na;Eunmi Kim;Heecheon You
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.42-52
    • /
    • 2024
  • Background: The lack of headforms that accurately reflect the head characteristics of Koreans and the demographic composition of the Korean population can lead to inadequate FFR testing and reduced effectiveness of FFRs. Method: Direct measurements of 5,110 individuals and 3D measurements of 2,044 individuals, aged between 9 and 69 years, were sampled from the data pool of Size Korea surveys based on the age and gender ratios of the Korean resident demographics. Seven head dimensions were selected based on the ISO 16976-2, availability of Size Korea measurements, and their relevance to the fit performance of FFRs. A principal component analysis (PCA) was performed using the direct measurements to extract the main factors explaining the head characteristics and then the main factors were standardized and remapped to 3D measurements, creating five size categories representing Korean head shapes. Lastly, representative 3D headforms were constructed by averaging five head shapes for each size category. Results: The study identified two main factors explaining Korean head characteristics by the PCA procedure specified in ISO 16976-2 and developed five representative headforms reflecting the anthropometric features of Korean heads: medium, small, large, short & wide, and long & narrow. Conclusion: This study developed representative headforms tailored to the Korean population for conducting total inward leakage (TIL) tests on filtering facepiece respirators (FFRs). The representative headforms can be used for TIL testing by employing robotic headforms to enhance the performance of FFRs for the Korean target population.

Assessment of Occupational Health Risks for Maintenance Work in Fabrication Facilities: Brief Review and Recommendations

  • Dong-Uk Park;Kyung Ehi Zoh;Eun Kyo Jeong;Dong-Hee Koh;Kyong-Hui Lee;Naroo Lee;Kwonchul Ha
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.87-95
    • /
    • 2024
  • Background: This study focuses on assessing occupational risk for the health hazards encountered during maintenance works (MW) in semiconductor fabrication (FAB) facilities. Objectives: The objectives of this study include: 1) identifying the primary health hazards during MW in semiconductor FAB facilities; 2) reviewing the methods used in evaluating the likelihood and severity of health hazards through occupational health risk assessment (OHRA); and 3) suggesting variables for the categorization of likelihood of exposures to health hazards and the severity of health effects associated with MW in FAB facilities. Methods: A literature review was undertaken on OHRA methodology and health hazards resulting from MW in FAB facilities. Based on this review, approaches for categorizing the exposure to health hazards and the severity of health effects related to MW were recommended. Results: Maintenance workers in FAB facilities face exposure to hazards such as debris, machinery entanglement, and airborne particles laden with various chemical components. The level of engineering and administrative control measures is suggested to assess the likelihood of simultaneous chemical and dust exposure. Qualitative key factors for mixed exposure estimation during MW include the presence of safe operational protocols, the use of air-jet machines, the presence and effectiveness of local exhaust ventilation system, chamber post-purge and cooling, and proper respirator use. Using the risk (R) and hazard (H) codes of the Globally Harmonized System alongside carcinogenic, mutagenic, or reprotoxic classifications aid in categorizing health effect severity for OHRA. Conclusion: Further research is needed to apply our proposed variables in OHRA for MW in FAB facilities and subsequently validate the findings.

ICU nurses' ethical attitudes about DNR (중환자실 간호사들의 DNR에 대한 윤리적 태도)

  • Yu, Eun-Yeong;Yang, Yu-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2691-2703
    • /
    • 2015
  • This research aims to provide basic materials for assisting DNR patient cares by understanding ICU nurses' awareness and ethical attitude regarding DNR. A total of 154 results were analyzed which were collected from Aug. 1st to Sep. 5th in 2014 by surveying nurses working in ICU (from 1 advanced general hospital in G metropolitan city and other general hospitals of more than 700 beds in Cheolla provinces). (1) For the decision attitudes of DNR, there were both consent and objection. Consent for the patient's opinion of rejecting further treatment and life extension despite of bad prognosis. And objection for no conducting DNR in the case of the patient's wish, treatment requested by the guardian, and CPR for the patient who has no chance. (2) Objection for artificial respirator and other treatment requested by the patient's family and the entrance of guardians into ICU. Consent for the passive use of artificial respirator by the doctor and the decrease of basic care to stabilize patients physically and mentally. No specific opinion for treatment not following aseptic techniques. Objection for frequent reports to primary care physician requested by the family. (3) Acknowledging less interest by the doctor, while supporting the health care team in the case of the guardian's complaint, objection for the DNR decision mede by the primary care physician. Objection for the DNR decision by the guideline. Objection or neutrality for straightforward explanation to the patient of bad prognosis. Objection for straightforward explanation of the patient's status (even near to death) to the patient him/herself or the guardian. In conclusion, the subject of DNR is the patient and the patient's opinion should be fully reflected. The conflict arising from the scope of medical practice and decision processes should be minimized. The standard and guideline for DNR decision is required for the ethical decision making for the patient along with agreements based on full explanations.

Education Needs for Home Care Nurse (가정간호 교육요구도 조사 연구)

  • Kim Cho-Ja;Kang Kyu-Sook;Baek Hee-Chon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.2
    • /
    • pp.228-239
    • /
    • 1999
  • In 1990 Home Care Education Programs started when legislation established certification for Home Care Nurses. The Ministry of Health and Welfare proposed a home care education curriculum which has 352 class hours and 248 hours of 'family nursing and practice'. Though Home Care Education Programs have been offered in 11 home care educational institutes, there has been no formal revision for the home care education programs. Also a first and second home care demonstration projects have been carried out, but there has been no research on outcomes for home care education as applied in home care practice. The purposes of this study were to identify the important content areas for home care nursing as perceived by home care nurses, and to identify their clinical competence in each of these areas, and from these to identify the education needs. The sample was 107 home care nurses who were working in home care demonstration hospitals and community-based institutions which have been offering home care services. Responses were received from 88 nurses, comprising a 82.2% return rate, and 86 were included in the final analysis. The instrument used was a modification of the instrument developed by Caie-Lawrence et(1995) and Moon's(1991) instrument on home care knowledge. The instrument's Cronbach's coefficient was 0.982. Among the respondents, 64% were working at home care demonstration hospitals and 36% were working at community-based institutions. Their home care experiences were from one month to six years, with a mean of 20.6 months. The importance rating for home care education content was 3.42 0.325, which means importance was rated relatively high. Technical aspects of home care were identified the most important. Five items 'education skill', 'counseling skill', 'interview skill', 'wound care skill', 'bed sore care skill' received 100% importance ratings. The competency rating was 2.87 0.367 and 'technical aspects of home care' was the highest, and 'application to home care skill' was the lowest. Home care nurses' education needs were identified and compared to the importance ratings and competency ratings. Eleven items were identified as the highest in the importance areas and eleven items were in the lowest competency areas. High importance ratings matched with low competency ratings determined training needs, but there was no matching items in this study. In the lowest competency areas four items were excluded, because of not being applicable in current home care practice. Therefore total eighteen items were identified as home care education needs. These items are 'bed sore care skill', 'malpractice', 'wound care skill', 'general infection control', 'change and management of tracheostomy tubes', 'CVA patient care', 'Hospice care', 'pain management', 'urinary catheterization and management', 'L-tube insertion and managements', 'Respirator use and management skill', 'infant care', 'prevention to burnout', 'child assessment', 'CAPD', 'infant assessment', 'computer literacy', and 'psychiatry patient care'.

  • PDF

The Arterial Blood Pressure Response to the Stimulation of Peripheral Afferent Nerves in Cats (말초감각신경 자극이 동맥혈압변화에 미치는 영향에 관한 연구)

  • Lim, Seung-Pyung;Kim, Jun;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.439-450
    • /
    • 1987
  • The arterial blood pressure response elicited by stimulating the peripheral afferent fibers of different groups and origins was studied in cats. Experimental animals were anesthetized with a-chloralose [60mg/kg] and artificially ventilated with a respirator. The lumbosacral spinal cord was exposed through a laminectomy and L7 ventral root was isolated. The sural, medial gastrocnemius and common peroneal nerves were also exposed in the hindlimb. The arterial blood pressure was monitored continuously while the exposed peripheral nerves and L7 ventral root were being stimulated. Then, spinal lesions were made on the dorsolateral sulcus area, dorsolateral funiculus and other areas at the thoracolumbar junction. The arterial blood pressure responses were compared before and after making spinal lesions. The following results were obtained. 1. The mean arterial blood pressure was elevated from 103*7.3 to 129*8, 1 [mean*S.E.] mmHg [p<0.001] during stimulation of the sural nerve with C-strength [1000T], 20Hz. Stimulation with Ad-strength, 1Hz resulted in the depression of the arterial pressure by 8 mmHg [p<0.01]. 2. Stimulation of the medial gastrocnemius nerve with Ad-strength did not elicit any significant change in arterial blood pressure. Stimulation with C-strength, 20 Hz induced a pressor response from 102*6.2 to 117*6.4 mmHg [p<0.01] while that with C-strength, 1Hz induced a depressor response from 104*6.1 to 93*4.9 mmHg [p<0.001]. 3. A pressor response by 56 [from 107*7 5 to 163*9.4] mmHg [p<0.001] was induced during stimulation of the common peroneal nerve with C-strength, 20Hz stimuli. Stimulation with A4-strength, 1Hz depressed the arterial blood pressure from 111~9.3 to 94*7.8 mmHg [P<0.005]. The activation of the ventral root afferent fibers with C-strength, 20 Hz stimuli induced a pressor response by 22 mmHg [from 115*9.4 to 137*8.6 mmHg] [p<0.001]. 4. The pressor response elicited during stimulation of the sural nerve was abolished by making lesions on the dorsolateral sulcus area bilaterally. With the medial gastrocnemius nerve, the pressor response had not been abolished completely by the dorsolateral sulcus lesions. The pressor response disappeared completely with addition of the bilateral dorsolateral funiculus lesions. 5. The depressor response induced by stimulation of the sciatic nerve with Ad-strength, 1Hz was decreased by making lesions on the dorsolateral funiculus. 6. From the above results it is concluded that the difference in the blood pressure responses to the activation of the muscular afferent and the cutaneous afferent fibers is responsible for the groups of afferent fibers and the spinal ascending pathways.

  • PDF

Effects of Wearing between Respirators and Glasses Simultaneously on Physical and Visual Discomforts and Quantitative Fit Factors (안면부 여과식 방진마스크와 안경 동시 착용 시 불편감과 밀착계수 비교)

  • Eoh, Won Souk;Choi, Youngbo;Shin, Chang Sub
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.52-60
    • /
    • 2018
  • This study compares the differences of the fit factor by the order of wearing preference between Particulate filtering facepiece respirators(PFFR) and glasses when participants wore simultaneously and a survey of physical and visual complaint. Recognition level about fit of respirators was investigated and the educational (before- and after-) effect of the fit factor. When participants wore PFFR and glasses, physical complaints were nose pressure, slipping, nose and ear pressure, ear pressure and rim loosen, the most highly physical complaints were nose pressure. Visual complaints were demister, blurry vision, dizziness, visual field, and lens dirty, the most highly visual complaints were demister. But, there was significant difference in physical complaint such as nose pressure(10.3%), slipping (23.0%), nose and ear pressure(14.3%), and rim loosen(16.2%), visual complaint such as visual field(13.8%) and lens dirty(32.4%). For the recognition of fit of respirators, respirators fitness, leak site, an initial point and an object, faulty factor, recognition level was higher. Fit factor was increased after education of proper wearing of respirator. Change of the fit factor was smaller compared to the normal breathing and after 6 actions in case of after education. Questionnaire consisted of general characteristics and physical/visual complaint, recognition of fit. Complaints were measured after the QNFT with multiple choices. Quantitative fit factor was measured by device and compared the result of (before- and after-) educational effect. Also, we selected to 6 actions (Normal breathing, Deep breathing, Bending over, Turning head side to side, Moving head up and down, Normal breathing) among 8 actions OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The fit factor was higher after the training (p=0.000). Descriptive statistics, paired t-test, and Wilcoxon analysis were performed to describe the result of questionnaire and fit test. (P=0.05) Therefore, it is necessary to investigate the quantitative research such as training program and glasses fitting factor about the wearing of PFFR and glasses simultaneously.

Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion (상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

Effect of Blood Pressure on Contractility of Vascular Smooth Muscle and Endothelium-Dependent Relaxation

  • Suh, Suk-Hyo;Park, Yee-Tae;Lee, Dong-Chul;Seo, Pil-Won;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.29 no.2
    • /
    • pp.279-289
    • /
    • 1995
  • This study was designed 1) to develop a hypertensive animal model in which the blood pressures (BPs) of symmetric regions (right and left upper extremities) are significantly different and 2) to test the effect of BP per se on the contractility and endothelium-dependent relaxation of vascular smooth muscle. Rabbits were anesthetized with sodium pentobarbital and ventilated with room air via animal respirator. The transverse aorta was exposed through the left second intercostal space and the lumen of the aorta was narrowed partially by ligation using 3-0 silk and a probe at a point between the origins of the brachiocephalic trunk and the left subclavian artery. Four to eight weeks postoperatively, BPs were measured in the carotid artery as the high BP area (proximal to coactation site) and in the femoral artery as the low BP area (distal to coarctation site). In the animal model, pressure-overload hypertension was developed and the BP of the right subclavian artery was higher than that of the left subclavian artery. The concentrations of circulating epinephrine, norepinephrine, angiotensin I, and angiotensin II were measured. The right and left subclavian arteries and their branches were used for isometric tension recording in organ baths and their responsiveness to phenylephrine, serotonin, acetylcholine, and sodium nitroprusside were examined. The BPs of carotid and femoral artery in control animals were $116{\pm} 12/75{\pm}9\;mmHg (mean ${\pm}SEM$) and $130{\pm}16/68{\pm}9\;mmHg$ respectively, while those of carotid and femoral artery in the hypetensive animals were $172{\pm}6/111{\pm}10\;mmHg$ and 136{\pm} 4/100 {\pm}9\;mmHg$ respectively. There were no significant differences in the concentrations of circulating epinephrine, norepinephrine, angiotensin I, and angiotensin II between controls and the animal models. No significant differences were found in the vascular sensitivities to phenylephrine and serotonin between the high pressure-exposed vessels and the low pressure-exposed vessels. However, the endothelium-dependent relaxation to acetylcholine and nitroprusside-induced relaxation showed significant differences between the high pressure-exposed and the low pressure-exposed subclavian arteries. From the above results, we suggest that the contractility of vascular smooth muscle is unchanged by the elevated pressure per se. However, the endothelium-dependent relaxation to acetylcholine and the nitroprusside-induced relaxation are attenuated by pressure.

  • PDF

Effect of Carbamazepine on the Ouabain-Induced Arrhythmia in Rabbits (가토의 Quabain-Induced Arrhythmia에 미치는 Carbamzepine의 효과)

  • Kim, Eui-Hong;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.3 no.1
    • /
    • pp.279-285
    • /
    • 1986
  • Carbamazepine is a derivative of iminostilbene with carbamyl group and related chemically to the tricyclic antidepressants. Carbamazepine has been introduced for treatment of trigeminal neuralgia. Recently it is used as an antiepileptic agent such as diphenylhydantoin. Antiepileptic drugs are known to affect experimentally induced cardiac arrhythmia and are now widely used clinically for treatment of ventricular tachyarrhythmias, particularly those produced by digitalis intoxication. Steiner et al.(1970) reported that carbamazepine was found to be very effective in converting ventricular tachycardia due to digitalis toxicity to normal sinus rhythm. Clinically bradycardia, complete heart block, ventricular standstill and Adams-stokes attack were reported in the course of carbamazepine treatment. The purpose of this study was to investigate the effects of carbamazepine on the ouabain-induced arrhythmia in vivo. The rabbits of either sex, weighing from 1.6 to 3.2kg were anesthesized by urethane. After the trachea was cannulated, the rabbits were ventilated with room air using a respirator. Drugs were given into polyethylene cannula in the femoral vein. Blood pressure were recorded by physiograph via pressure tranducer connected with the cannula in the femoral artery. EKG were recorded by Physiograph via electrode implanted in both fore leg and left hind leg. The results are summarized as follows; 1. Arrhythmia was induced by continuous infusion of ouabain.($64{\pm}8.8{\mu}g/kg$) 2. Single administration of ouabain($64{\mu}g/kg$) induced arrhythmia which was persisted for 7-8 min. 3. Ouabain induced arrhythmia was restored to normal sinus rhythm by administration of carbamazepine.(The more dosage, the less frequent and the longer duration) 4. Severe bradycardia, A-V block, atrial fibrillation were seen on the EKG after injection of carbamazepine alone. By the above results, it may be concluded that carbamazepine inhibits the ouabain-induced arrhythmia by dose-dependent.

  • PDF