• 제목/요약/키워드: respiration curve

검색결과 34건 처리시간 0.027초

완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로- (Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate-)

  • 박영배;강성길;김창환;고형균;김용석;이윤호;김성운;허웅;윤충화
    • 대한한의학회지
    • /
    • 제18권1호
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

Assessment of Greenhouse Gas Emissions from Poultry Enteric Fermentation

  • Wang, Shu-Yin;Huang, Da-Ji
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권6호
    • /
    • pp.873-878
    • /
    • 2005
  • Emissions of nitrous oxide (N$_2$O) and methane (CH$_4$) from poultry enteric fermentation were investigated using a respiration chamber. Birds were placed in a respiration chamber for certain intervals during their growing period or for the whole life cycle. The accumulated gas inside the chamber was sampled and analyzed for N$_2$O and CH$_4$ production. A curve for gas production during a life cycle was fitted. The calculated area under the curve estimated the emission factor of poultry enteric fermentation on a life cycle basis (mg bird$^{-1}$ life cycle$^{-1}$). This method can be used to estimate CH$_4$ or N$_2$O emissions from different types of avian species taking into account factors such as diet, season or thermal effects. The CH$_4$/N$_2$O emission factors estimated for commercial broiler chickens, Taiwan country chickens and White Roman Geese were 15.87/0.03, 84.8/16.4 and 1,500/49 (mg bird$^{-1}$ life cycle$^{-1}$), respectively, while the calculated CH$_4$/N$_2$O emission from enteric fermentations were 3.03/0.006, 14.73/2.84 and 9.5/0.31 (Mg year$^{-1}$), respectively in Taiwan in the year of 2000. The described method is applicable to most poultry species and the reported emission factors were applicable to meat type poultry only.

Measurement of Variation in Water Equivalent Path Length by Respiratory Organ Movement

  • Minohara, Shinichi;Kanai, Tatsuaki;Endo, Masahiro;Kato, Hirotoshi;Miyamoto, Tadaaki;Tsujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.90-93
    • /
    • 2002
  • In particle radiotherapy, a shape of the beam to conform the irradiation field is statically defined by the compensator, collimator and potal devices at the outside of the patient body. However the target such as lung or liver cancer moves along with respiration. This increases the irradiated volume of normal tissue. Prior discussions about organ motions along with respiration have been mainly focused on inferior-superior movement that was usually perpendicular to beam axis. On the other hand, the change of the target depth along the beam axis is very important especially in particle radiotherapy, because the range end of beam (Bragg peak) is so sharp as to be matched to distal edge of the target. In treatment planning, the range of the particle beam inside the body is calculated using a calibration curve relating CT number and water equivalent path length (WEL) to correct the inhomogeneities of tissues. The variation in CT number along the beam path would cause the uncertainties of range calculation at treatment planning for particle radiotherapy. To estimate the uncertainties of the range calculation associated with patient breathing, we proposed the method using sequential CT images with respiration waveform, and analyzed organ motions and WELs at patients that had lung or liver cancer. The variation of the depth along the beam path was presented in WEL rather than geometrical length. In analyzed cases, WELs around the diaphragm were remarkably changed depending on the respiration, and the magnitude of these WEL variations was almost comparable to inferior-superior movement of diaphragm. The variation of WEL around the lung was influenced by heartbeat.

  • PDF

미생물의 세포생리에 미치는 전이방사선의 영향에 관한 연구 (제 2보) - 효모균의 산소호흡기및 탈수소효소능에 대한 $\gamma$-ray 의 영향 (Studies on the Cellular Metabolism in Microorganisms as Influenced by Gamma-irradiation.(II) - On the Respiration Rate and Dehydrogenase Actibity in Yeast Cells Irradiated by $\gamma$-ray.)

  • 김종협
    • 미생물학회지
    • /
    • 제5권2호
    • /
    • pp.69-78
    • /
    • 1967
  • Kim, Jong Hyup, (Div. of Biology, Atomic Energy Research Institute.) Studies on the Cellular Metabolism in Microorganisms as influenced by Gamma-irradiation(II). On respiration rate and dehydrogenase activity of yeast cells irradiated by gamma ray from cobalt-60. 1. Oxygen uptake rate of the gamma irraiated yeast cells had been measured with Warburg's manometer, and the $O_{2}$-uptake was compared with those of normal cells. The rate of endogetious respiration increases in its $O_2$-uptake at 150, 000 rentgen dose, and at higher rentoen doses it was decreased. Exogenous respiration begin to decrease in its O_2$-uptake at 5, 000r. doses of irradiation, further decrease with increasing of doses unproportionally. 2. It appears that plasma-membrane and nuclear membrane of yeast cells have changed and denatured by gamma-irradiation, as exogenous respiration of glucose had been decreased at a dose of 200, 000r's irradiation. 3. The activity of glucose, alcoholic, lactic, succinic and glutamic deliydrogenase (G.D.H., A.D.H., L.D.H., S.D.11., and GL.D.H.) in the gamma irradaited cells had been assayed by T.T.C.(Triphenyl tetrazolium chloride) method and spectrophotometry, the obtained results were compared with those of normal cells. 4. At a dose of and 10, 000 rentgens' irradiation of gamma ray, the activty of each debydrogenase (G.D.H., A.D.H., L.D.H., ) shows a sharp and highest peak in optical absorbalicy, but each abtivity of S.D.H and Gl.D.H shows its' maximum peak at a dose of 30, 000r. 5. The curve of each dehydrogenase activity was found to be rhythmical according to dose-rate of gamma irradiation. 6. Comparing with activity of debydrogenase each other, the maximum peak in optical absorbency can be arranged according to order as follows; glucose > alcoholoic > lactic > glutamic > succinic, this order is identical to the order of breakdown utility in respiration of normal yeast cells. 7. The activity of dehydrogenase experimented exhibit a resistance against gamma irradiation at lethal dose of cells, and the activity of dehydrogenase are found to be much resistant than those of respiratory system. We may assume that the membrane substrate of mitochondria or cytoplasm had been destructed by gamma-irradiation much more than that of dehydronase system.

  • PDF

Evaluation of sensitivity of soil respiration to temperature in different forest types and developmental stages of maturity using the incubation method

  • Lee, Eun-Hye;Suh, Sang-Uk;Lee, Chang-Seok;Lee, Jae-Seok
    • Journal of Ecology and Environment
    • /
    • 제35권1호
    • /
    • pp.1-7
    • /
    • 2012
  • To calculate and predict soil carbon budget and cycle, it is important to understand the complex interrelationships involved in soil respiration rate (Rs). We attempted to reveal relationships between Rs and key environmental factors, such as soil temperature, using a laboratory incubation method. Soil samples were collected from mature deciduous (MD), mature coniferous (MC), immature deciduous (ID), and immature coniferous (IC) forests. Prior to measure, soils were pre-incubated for 3 days at $25^{\circ}C$ and 60% of maximum water holding capacity (WHC). Samples of gasses were collected with 0, 2, and 4 h interval after the beginning of the measurement at soil temperatures of 5, 15, 25, and $35^{\circ}C$ (at 60% WHC). Air samples were collected using a syringe attached to the cap of closed bottles that contained the soil samples. The $CO_2$ concentration of each gas sample was measured by gas chromatography. Rs was strongly correlated with soil temperature (r, 0.93 to 0.96; P < 0.001). For MD, MC, ID, and IC soils taken from 0-5 cm below the surface, exponential functions explained 90%, 82%, 92%, and 86% of the respective data plots. The temperature and Rs data for soil taken from 5-10 cm beneath the surface at MD, MC, ID, and IC sites also closely fit exponential functions, with 83%, 95%, 87%, and 89% of the data points, respectively, fitting an exponential curve. The soil organic content in mature forests was significantly higher than in soils from immature forests (P < 0.001 at 0-5 cm and P < 0.005 at 5-10 cm) and surface layer (P = 0.04 at 0-5 cm and P = 0.12). High soil organic matter content is clearly associated with high Rs, especially in the surface layer. We determined that the incubation method used in this study have the possibility for comprehending complex characteristic of Rs.

미생물 호흡속도에 기초한 혼합배양중의 생균수 측정 (Measurement of Viable Cell Number in Mixed Culture Based on Microbial Respiration Rate)

  • ;권윤중
    • 한국미생물·생명공학회지
    • /
    • 제20권6호
    • /
    • pp.687-692
    • /
    • 1992
  • 혼합배양중의 각 미생물의 생균수 측정은 순수배양보다 훨씬 복잡하다. 특히 두 균주의 크기가 비슷한 경우에는 사용할 수 있는 방법이 더 제한된다. 본 연구에서는 두 균의 크기가 비슷한 경우에도 적용될 수 있는 간단한 생균수 측정방법을 개발하였다. 미생물 배양액의 산소흡수속도(OUR)는 세포수에 비례하며 이때의 비례상수인 최대 비산소흡수속도( maximum specific OUR)를 알고 있으면 배양액의 OUR을 측정함으로써 간접적으로 생균수를 구할 수 있게된다. 혼합배양의 경우 산소흡수속도는 각 미생물의 호흡속도의 합이 되며, 각 미생물의 호흡속도가 서로 다르고 또한 온도의존성이 다르다면 호흡속도의 측정을 이용하여 각 생균수를 간접적으로 측정할 수 있다.

  • PDF

열전쌍마스크를 이용한 호흡모사팬톰 연구 (Study of Respiration Simulating Phantom using Thermocouple-based Respiration Monitoring Mask)

  • 임상욱;박성호;이병용;이상훈;조삼주;허현도;신성수;김종훈;이상욱;권수일;최은경;안승도
    • Radiation Oncology Journal
    • /
    • 제23권4호
    • /
    • pp.217-222
    • /
    • 2005
  • 목적: 호흡동기치료, 호흡조절 방사선치료 등 호흡에 관련된 치료법의 연구를 위해 열전쌍마스크(Respiration Monitoring Mask: ReMM)를 이용한 호흡모사팬톰을 개발하였다. 대상 및 방법: 호흡신호에 따라 실시간으로 움직이는 호흡모사팬톰을 제작하였다. 열전쌍으로 환자의 호흡을 측정하고, 측정된 호흡 신호와 장기의 움직임을 비교 분석하여 팬톰의 성능을 평가하였다. 환자의 호흡 측정에는 본 원에서 개발한 ReMM을 사용하였으며, 호흡모사팬톰의 운동은 $RPM^{(R)}$(Real-time Position Management, Varian, USA)으로 측정하였다. 횡격막 부위의 장기 운동을 확인하기 위하여 X-선 투시기를 사용하였다. 결과: X-선 투시영상과 $RPM^{(R)}$으로 관찰한 장기의 움직임을 ReMM으로 측정한 호흡 신호와 비교했을 경우, 각각 표준편차 9.68% 및 8.53% 이내에서 일치하였다. 호흡 신호에 따른 팬톰 운동의 오차는 호흡진폭에 대하여 표준편차 8.52%이내에서 일치하였다. 결론: ReMM은 환자가 호흡을 하는데 불편함이 없었고, 열전쌍에서 발생되는 호흡 신호를 이용한 호흡모사 팬톰은 장기의 운동을 실시간으로 잘 모사하였다. 호흡모사전통은 호흡동기치료 등 다양한 치료법의 평가에 응용할 수 있을 것으로 기대한다.

배추흰나비의 變態에 따른 血蛋白質과 酸素消費量의 變化 (Changes in Hemolymph Protein Concentration and Oxygen Consumption during the Metamorphosis in pieris rapae L.)

  • Kim, Chang-Whan;Lee, Kyung-Ro;Kim, Hak-Ryul
    • 한국동물학회지
    • /
    • 제12권2호
    • /
    • pp.60-66
    • /
    • 1969
  • 배추흰나비(Pieris rapae Linne)의 變態에 따른 hemolymph protein 의 濃度變化와 酸素消費量 및 5齡의 呼吸基質에 對한 活性度를 各各 Biuret method 와 Warburg manometric method 로 測定하여 形態的 變化를 比較하였다. 1. Hemolymph protein 의 濃度는 終齡幼蟲에서 가장 높으며 變態에 따라 감소하여 용기말에서 다시 增加한다. 2. Endogenous respiration은 전용기에서 가장 높은 酸素消費量을 보이며 變態에 따라 감소하여 용기말에서 다시 增加한다. 3. Glucose 는 全變態期를 通하여 다른 呼吸期質보다도 가장 큰 活性을 보이며 전용과 용기말에서 현저하게 영향을 미친다. 4. Hemolymph protein 의 濃度變化와 酸素消費量은 全變態期를 通하여 밀접한 연관을 가지며 幼蟲器官의 解消와 成蟲器官의 新生에 따라 U字型을 나타낸다.

  • PDF

호흡경로 상에 감지소자가 없는 새로운 호흡기류 계측기술 (Respiratory air flow measuring technique without sensing element on the flow stream)

  • 이인광;박준오;이수옥;신은영;김경천;김경아;차은종
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.294-300
    • /
    • 2009
  • Cardiopulmonary resuscitation(CPR) is performed by artificial ventilation and thoracic compression for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Quality of the pre-hospital CPR not only significantly affects the patient's survival rate but also minimizes side effects caused by CPR. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are located on the flow axis. The present study developed a new technique with no physical object on the flow stream but enabling the air flow measurement and easily incorporated with the CPR devices. A turbulence chamber was formed in the middle of the respiratory tube by locally enlarging the cross-sectional area where the flow related turbulence was generated inducing energy loss which was in turn converted into pressure difference. The turbulence chamber was simply an empty enlarged air space, thus no physical object was placed on the flow stream, but still the flow rate could be evaluated. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1 %. The present results can be usefully applied to accurately monitor the air flow rate during CPR.

인공심폐소생술에 활용 가능한 호흡기류센서 (Respiratory Air Flow Transducer Applicable to Cardiopulmonary Resuscitation Procedure)

  • 김경아;이인광;이유미;유희;김영일;한상현;차은종
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.833-839
    • /
    • 2013
  • Cardiopulmonary resuscitation (CPR) is performed by thoracic compression and artificial ventilation for the patient under emergent situation to maintain at least the minimum level of respiration and blood circulation for life survival. Good quality CPR requires monitoring respiration, however, traditional respiratory air flow transducers cannot be used because the transducer elements are facing the whole area perpendicular to the flow axis. The present study developed a new air flow transducer conveniently applicable to CPR. Specially designed "sensing rod" samples the air velocity at 3 different locations of the flow cross-section, then transforms into average dynamic pressure by the Bernoulli's law. The symmetric structure of the sensing holes of the sensing rod enables bi-directional measurement simply by taking the difference in pressure by a commercial differential pressure transducer. Both inspiratory and expiratory flows were obtained with symmetric measurement characteristics. Quadratic curve fitting provided excellent calibration formula with a correlation coefficient>0.999 (P<0.0001) and the mean relative error<1%. The present results can be usefully applied to accurately monitor the air flow rate during CPR.