• Title/Summary/Keyword: resonant inverter

Search Result 601, Processing Time 0.021 seconds

Analysis of Output Characteristics for the Resonant DC Link Inverter Using PWM Inverter Modulation Methods (인버터 PWM 방식을 이용한 공진형 직류 링크 인버터의 출력 특성 해석)

  • 김윤호;윤병도;이병순
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.615-624
    • /
    • 1992
  • For the operation of the resonant DC link inverters, only limited number of modulation techniques such as the delta modulation and instantaneous current control techniques have been suggested. However, these modulation techniques have some limitations in practical operation. In this paper, the application of conventional inverter modulation techniques is suggested for the control of the resonant DC link inverter. The harmonic analysis results are presented. The results show that these modulation techniques offer good output characteristics similar to conventional inverter PWM techniques for the operation of the resonant DC link inverter. This implies that not only the delta modulation technique and instantaneous current control techniques but also various other modulation techniques can be applied to the operation of the resonant DC link inverter. This also indicates that open loop control as well as closed loop control can be used for the operation of the resonant inverter. The resonant DC link inverter with various modulation strategies is implemented using V-40 microprocessors.

  • PDF

A Study on teh Improvement of Resonant Inverter (공진형 인버터의 개성에 관한 연구)

  • Sul, Seung-Ki
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.7
    • /
    • pp.680-691
    • /
    • 1990
  • In this paper the conventional resonant inverters are compared and a novel parallel resonant dc pulse inverter for high performance motor drive system is proposed. The design method and related equations for the novel resonant inverter are derived. Also, a current controller for the resonant inverter is proposed and compared with PI current controller of the conventional PWM inverter by analog simulation. The novel resonant inverter and the current controller are implemented to verify the suggested design principles. The analog simulation and the experimental results shown the satisfactory operation of the proposed inverter and the controller.

  • PDF

A Novel Auxiliary Edge-Resonant Snubber-Assisted Soft Switching PWM High Frequency Inverter with Series Capacitor Compensated Resonant Load for Consumer Induction Heating

  • Ahmed Nabil A.;Iwai Toshiaki;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.95-103
    • /
    • 2006
  • In this paper, a novel prototype of auxiliary switched capacitor assisted voltage source soft switching PWM Single-Ended Push Pull (SEPP) series capacitor compensated load resonant inverter with two auxiliary edge resonant lossless inductor snubbers is proposed and discussed for small scale consumer high-frequency induction heating (IH) appliances. The operation principle of this inverter is described by using switching mode equivalent circuits. The newly developed multi resonant high-frequency inverter using trench gate IGBTs can regulate its output AC power via constant frequency edge-resonant associated soft switching commutation by using an asymmetrical PWM control or duty cycle control scheme. The brand-new consumer IH products which use the newly proposed edge-resonant soft switching PWM-SEPP type series load resonant high-frequency inverters are evaluated using power regulation characteristics, actual efficiency vs. duty cycle and input power vs. actual efficiency characteristics. Their operating performance compared with some conventional soft switching high-frequency inverters for IH appliances is discussed on the basis of simulation and experimental results. The practical effectiveness of the newly proposed soft switching PWM SEPP series load resonant inverter is verified from an application point of view as being suitable for consumer high-frequency IH appliances.

PLL Technique for Resonant Frequency Trancking in High Frequency Resonant Inverters (공진형 고주파 인버터에서의 공진주파수 추적을 위한 PLL 기법)

  • 김학성
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.368-371
    • /
    • 2000
  • The PLL(Phase-Locked Loop) techniques re employed to make the switching frequency of a resonant inverter follow the resonant frequency which may vary due to the load variations during operation. The conventional design guide of PLL is not suitable in these case since the inverter characteristics are not considered. In this paper the phase characteristics of a resonant inverter is analysed and added to the closed loop. And the design of PLL with digital phase detector is illustrated for the output frequency to track the resonant frequency of the inverter.

  • PDF

Series Load Resonant Soft-Switching PWM High Frequency Inverter with Auxiliary Active Edge-Resonant Snubber

  • Saha, Bishwajit;Kim, Hun-Ho;Han, Ho-Dong;Kwon, Soon-Kurl;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.278-280
    • /
    • 2006
  • In this paper, a novel type of auxiliary active snubbingcircuit assisted quasi-resonant soft-switching pulse width modulation inverter is proposed for consumer induction heating equipments. The operation principle of this high frequency inverter is described using switching modes and equivalent circuits. This newly developed series resonant high frequency inverter can regulate its high frequency output AC power under a principle of constant frequency active edge resonant soft- switching commutation by asymmetrical PWM control system. The high frequency power regulation and actual power conversion efficiency characteristics of consumer induction heating (IH) products using the proposed soft-switching pulse width modulation (PWM) series load resonant high frequency inverter evaluated. The practical effectiveness and operating performance of high frequency inverter are discussion on the basis of simulation and experimental results as compared with the conventional soft-switching high frequency inverter.

  • PDF

Induction Heated Load Resonant Tank High Frequency Inverter with Asymmetrical Auxiliary Active Edge-Resonant Soft-Switching Scheme

  • Saha Bishwajit;Fathy Khairy;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.200-202
    • /
    • 2006
  • In this paper, a novel type of auxiliary active snubbing circuit assisted quasi-resonant soft-switching pulse width modulation inverter is proposed for consumer induction heating equipments. The operation principle of this high frequency inverter is described using switching modes and equivalent circuits. This newly developed series resonant high frequency inverter can regulate its high frequency output AC power under a principle of constant frequency active edge resonant soft-switching commutation by asymmetrical PWM control system. The high frequency power regulation and actual power conversion efficiency characteristics of consumer induction heating (IH) products using the proposed soft-switching pulse width modulation (PWM) series load resonant high frequency inverter evaluated. The practical effectiveness and operating performance of high frequency inverter are discussion on the basis of simulation and experimental results as compared with the conventional soft-switching high frequency inverter.

  • PDF

A New Half-bridge Resonant Inverter with Load-Freewheeling Modes

  • Yeon, Jae-Eul;Cho, Kyu-Min;Kim, Hee-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.249-256
    • /
    • 2007
  • This paper presents a new circuit topology and its digital control scheme for a half-bridge resonant inverter. As the proposed half-bridge inverter can be operated in load-freewheeling modes, the pulse-width modulation (PWM) method can be used for the output power control. The proposed half-bridge inverter is based on the resonant frequency-tracking algorithm with the goal of maintaining the unity of the output displacement factor of the load impedance even in varying conditions. In this paper, the operation principle, electrical characteristics, and detailed digital control scheme of the proposed half-bridge resonant inverter are described. The experimental results of the prototype experimental setup to verify the validity of the proposed half-bridge inverter are presented and discussed.

Cost Effective Quasi-Resonant Soft Switching PWM High Frequency Inverter With Minimum Circuit Components for Consumer IH Cooker and Steamer

  • Sugimura, Hisayuki;Eid, Ahmad-M.;Nakaoka, M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.134-139
    • /
    • 2005
  • This paper presents a cost effective quasi-resonant soft-switching PWM high frequency inverter with minimum circuit components. This inverter can achieve wider soft commutation, simpler power circuit configuration, smaller volumetric size, lower cost and wider power regulation range, higher-efficiency as compared with single ended quasi-resonant ZVS-PFM inverter and active voltage clamped quasi-resonant ZVS-PWM inverter. The operation principle of the proposed inverter is described on the basis of the simulation and experimental results, together with its operating performances in steady state. The operating performances of this unique proposed high frequency inverter based on ZVS and ZCS arms-related soft commutation principle is evaluated and discussed as compared with the active voltage-clamped ZVS-PWM inverter and a conventional single-ended ZVS-PFM inverter. The practical effectiveness of a novel type quasi-resonant soft-switching PWM high frequency inverter using IGBT is actually proved for consumer induction heated appliances as rice cooker, hot water producer, steamer and super heated steamer. The extended bidirectional circuit topology of quasi-resonant PWM high frequency inverter with minimum circuit components is demonstrated, which operate as the direct frequency changer.

  • PDF

Design of a Single-stage Electronic Ballast using a Half-Bridge Resonant Inverter

  • Son, Young-Dae
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.3
    • /
    • pp.104-111
    • /
    • 2001
  • The design procedures and experimental results of a single-stage electronic ballast using half-bridge resonant inverter are presented in this paper. The proposed topology is based on a single-stage ballast which combines a boost converter and a half-bradge series resonant inverter. High power factor is achieved by using the boost semi-stage operating in discontinuous conduction mode and inverter semi-stage operated above resonant frequency to provide zero voltage switching is empolyed to ballast the fluorescent lamp Experimental results from the ballast system with 36W fluorescent

Performance Evaluations of Digitally-Controlled Auxiliary Resonant Commutation Snubber-Assisted Three Phase Voltage Source Soft Switching Inverter

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • This paper presents a performance analysis of typical Auxiliary Resonant Commutation Snubber-assisted three phase voltage source soft switching inverter which can operate under a condition of Zero Voltage Switching (ZVS) using a digital control scheme which is suitable for high power applications compared with resonant DC link snubber assisted soft switching inverter. The system performances of this inverter are illustrated and evaluated on the basis of experimental results.