• 제목/요약/키워드: resonance test

검색결과 980건 처리시간 0.029초

공진조건을 이용한 미소신호 안정도 해석 (Analysis of Small Signal Stability Using Resonance Conditions)

  • 조성진;장길수;윤태웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.535-543
    • /
    • 2002
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be identified well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range is found by the analysis of resonance condition, and it is shown that reactive power compensation may solve the problem in the weak points. The proposed method is applied to test systems, and the results illustrate its capabilities.

공기압축기의 진동분석 및 진단 (Vibration analysis and diagnosis of air-compressor)

  • 이정환;김병수;구동식;김효중;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.994-999
    • /
    • 2008
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. Because vibration diagnosis can avoid sudden breakdown of machine and reduce the maintenance costs. In the factory, Air-Compressor which can affect the performance and capacity of output is important machine. Therefore, in this paper, The measuring and analyzing is carried out for air-compressor in order to the factor of resonance and resonance avoidance for air-compressor. The result of diagnosis and solution is discussed in this paper.

  • PDF

에어컨 홴 BLDC 전동기의 음향공진에 관한 연구 (Study on Acoustic Resonance of Air-conditioner Fan BLDC Motor)

  • 이홍주;권중학;이창민;황건용;황상문
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.863-869
    • /
    • 2009
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. This paper analyzes noise characteristics of a brushless DC motor for air-conditioner fan, and proves that the test motor noise originates from acoustic modes of airspace in the motor. The motor noise sensitivity analysis by design of experiments reveals that the noise characteristics are closely related to switching frequency and frame thickness.

온도 변화가 승용차용 레이디얼 타이어의 공기공동 공명 및 타이어의 진동특성에 미치는 영향에 관한 실험 (Experiments on Temperature Effect on Air Cavity Resonance and Tire's Vibration Characteristics of a Radial Tire)

  • 김용우
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.102-110
    • /
    • 2008
  • It is well known that the acoustic cavity inside the tire-wheel assembly contributes to vehicle interior noise and ride comfort. In this paper, we performed acoustic and structural modal testings by varying the temperature ranging from $20^{\circ}\;to\;45^{\circ}C$ to investigate the effects of temperature on acoustic cavity resonance and structural vibration characteristics for unloaded and loaded tires. The testing has given us some findings, which are reported in this paper.

내부 공동과 간극이 종 음향에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Influence of the Internal Cavity and Gap on the Bell Acoustics)

  • 정원태;강연준;김석현
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.822-827
    • /
    • 2010
  • In this study, it is experimentally investigated how bell acoustics are influenced by the internal cavity of the bell and the gap between the bell bottom and the floor. Acoustic transmission function and natural frequency of a test bell are measured and analysed. Experimental study is conducted to evaluated how the resonance effect influences the bell sound and how the bell sound is different according to the striking condition and the measurement direction. Acoustic resonance frequency of the cavity-gap system is predicted by boundary element analysis using SYSNOIS and the validity of the predicted result is verified by experiment. The result of the study could be applied to determine the optimal gap size which makes the bell sound strong and long.

박용 발전기세트 진동 제어를 위한 강성 조절형 마운트 개발 (Development of stiffness adjustable mount for vibration control of marine diesel generator set)

  • 김원현;주원호;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 2012
  • Marine diesel generator(D/G) set which is supported with resilient mounts for vibration isolation has been experienced the resonance problem by the main engine or propeller excitations and rigid body modes. Then the avoidance of resonance is difficult because the several excitations and 6 rigid body modes have to be considered simultaneously. In this paper, stiffness adjustable mounts was developed and proposed to control the natural frequencies of installed D/G set. Operating concept of the mount is that the total stiffness of mount can be changed according to the engagement of secondary rubber element in addition to primary one. The performance of mount was verified with the test rig and actual experiment in D/G set.

  • PDF

공진 조건을 이용한 미소신호 안정도 해석 (Analysis of small signal stability using resonance condition)

  • 조성진;장길수;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.109-111
    • /
    • 2001
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be predicted well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range can be identified by the analysis of resonance condition. The proposed method is applied to test systems, and the results illustrate its capabilities.

  • PDF

몰드변압기의 소음 원인 분석 (Analysis of Noise Source for Mold Transformer)

  • 최원호;김원철
    • 동력기계공학회지
    • /
    • 제4권4호
    • /
    • pp.59-64
    • /
    • 2000
  • Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

  • PDF

암반상 토노반 구간에서의 공진 속도 및 주파수에 대한 이론적 연구 (Theoretical Study for the Resonance Speed and Frequency in Roadbed on the Base Rock)

  • 이일화;황선근;이수형;최찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.443-447
    • /
    • 2005
  • When the high-speed train running on the track, there is a speed band which track distortion is unusually increased according to the condition of track and roadbed. This speed is called critical velocity and physical parameter value increased greatly. These phenomenon happened as high-speed train were developed, studied regularly through TGV 100 running test in France. As research result until now, the main reason is soft roadbed's capacity. Wave propagation and track support capacity is varied by the site characteristics. This paper achieved theoretical examination about resonance band(speed and frequency) that occurred in roadbed on the base rock in point of geotechnical engineering. The examination of resonance divides with ground response analysis, critical band analysis by the shear wave velocity of roadbed, train critical speed through the ground stratum.

  • PDF

저압 터빈용 Finger 형 블레이드의 공진 방지를 위한 개선 및 시험 (Modification and Testing to Prevent the Resonance in a Finger-type Low Pressure Turbine Blade)

  • 하현천;이동진;류석주;정희찬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.612-617
    • /
    • 2000
  • This paper describes the experience gained from the treatments for prevention of blade failure occurred in the low-pressure turbine. Some cracks due to high cycle fatigue were found at the blades in low-pressure turbines after long time operation. Such failure was mainly caused by the resonance of the blade with the vane passing frequency excitation. If a natural frequency of the blade exists near the excitation frequency, a resonant vibration can occur and leads to a large amount of stress which may cause fatigue failures in turbine blades. To avoid the resonance of the blade, some modifications have been performed and full-scaled mockup testing has been done to confirm the verification for modification. Test result shows that enlarging the span cover is very useful to change the natural frequency of the grouped blades effectively.

  • PDF