• 제목/요약/키워드: resistive peak

검색결과 50건 처리시간 0.026초

뇌서지가 ZnO바리스터에 미치는 영향 (Effects of Lightning Surges on the Life of ZnO Varistors)

  • 이봉;이수봉;강성만;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

YBCO 박막의 저항형 초전도 한류기에 대한 동작 특성 (Operating Properties for a Resistive SFCL of YBCO Thin Films)

  • 최효상;현옥배;김혜림;황시돌;김상준;문승현;한병성
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.537-543
    • /
    • 1999
  • We fabricated a resistive superconducting fault current limiter (SFCL) of a meander type based on a YBCO film with the meander cross section of 5 $\times$ $10^{-6}$$cm^2$, and performed current limitation experiments. The film was coated quench current was 9.6 Apeak at 60 Hz, and the fast quench time was 0.63 msec. The resistance of the limiter continuously increased for three cycles dut to the temperature rise in the gold layer. The temperature of the current limiting element reached the room temperature in 11 msec, $150^{\circ}C$ in 54 msec after quench, and was saturated afterwards. For $45^{\circ}$and $90^{\circ}$faults the fast quench times were 0.56 msec and 0.26 msec, respectively. The quench time is believed to be reduced because the fault occurred when the current was either increasing or at the peak value. This limiter effectively limited the fault current to about 1/5 of the potential current with no SFCL right after the fault and to about 1/8.5 in three cycles. We confirmed that the gold layer effectively carried out the role of heat dissipation as the SFCL was quenched.

  • PDF

Immediate Effects of High-frequency Diathermy on Muscle Architecture and Flexibility in Subjects With Gastrocnemius Tightness

  • Kim, Ji-hyun;Park, Joo-hee;Yoon, Hyeo-bin;Lee, Jun-hyeok;Jeon, Hye-seon
    • 한국전문물리치료학회지
    • /
    • 제27권2호
    • /
    • pp.133-139
    • /
    • 2020
  • Background: The gastrocnemius (GCM) is one of the lower extremity muscles that tend to tighten easily. GCM tightness results in limited ankle dorsi-flexion (DF), especially when the knee joint is fully extended. Joint flexibility is determined by the morphological and physiological characteristics of joints, muscles, tendons, and ligaments. Impaired joint flexibility can be attributed to increased susceptibility to muscle injury. High-frequency diathermy is clinically used to reduce pain and muscle tightness and to improve limited range of motion. Objects: This study aimed to investigate the immediate effects of high-frequency therapy in subjects with GCM tightness. Methods: The study was designed as a one-group before-after trial. The subjects included 28 volunteers with GCM tightness (an active ankle DF angle of less than 12°) without any known neurological and musculoskeletal pathologies in the ankle and calf areas. WINBACK Transfer Electrode Capacitive and Resistive Therapy equipment was used to apply high-frequency therapy to the subjects' GCMs for 10-15 minutes. The pennation angle and the fascicle length of the GCM were measured using ultrasonography. The flexibility of the ankle joint, peak torque to the passive ankle DF (Biodex), and soft tissue stiffness (MyotonPRO) were also measured. Results: The pennation angle was significantly decreased following the treatment; however, no significant difference in the fascicle length was found (p < 0.05). The flexibility was significantly increased and both the passive peak torque to passive ankle DF and the soft tissue stiffness significantly decreased (p < 0.05). Conclusion: High-frequency therapy is immediately effective for improving the muscle's architectural properties and functional factors in subjects with GCM tightness. Further longitudinal clinical studies are required to investigate the long-term effects of high-frequency therapy on subjects with GCM tightness from various causes.

두경부악성종양세포주의 항암제감수성 시험에 관한 실험적 연구 (CHEMOSENSITIVITY OF CANCER CELLS TO ANTICANCER DRUGS USING DYE EXCLUSION ASSAY, [3H] THYMIDINE INCORPORATION, AND CLONOGENIC ASSAY)

  • 진우정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권1호
    • /
    • pp.35-48
    • /
    • 1993
  • The in vitro predictive tests in cancer chemotherapy of cancer cell lines to anticancer drugs were determined using novel dye exclusion assay [NDEA], [3H] thymidine incorporation, and clonogenic assay [CA>. Antitumor effect of Bleomycin, Cis-platin, Vinblastine, Methotrexate to HEp-2, B16 cell lines using rapid assays was compared with [CA> in this study. In dye exclusion assay of B l6 cell line, cancer cells were sensitive to Bleomycin at all concentrations, to Vinblastine at the level of peak plasma concentration [PPC], ${\times}1/10$ [PPC](P<0.05). And Bleomycin revealed relatively good cytotoxicity than that of CDDP and vinblastine at ${\times}10$[PPC], (P<0.05). HEp-2 cells were resistive to methotrexate at the level of ${\times}100$[PPC] (P<0.05) In [3H] thymidine incorporation assay, B 16 cells were sensitive to Bleomycin, CDDP, Vinblastine at the level of [PPC], ${\times}10$ [PPC](P<0.01). Dose-dependent drugs of bleomycin, CDDP were more sensitive than Vinblastine at high concentration (P<0.05). In clonogenic assay, HEp-2 cell line was sensitive to three drugs of all concentrations except ${\times}10$ [PPC] of CDDP. B 16 cell line was sensitive to all drugs(P<0,01). In comparison of chemosensitivity tests among three assays, the results were correlated(${\gamma}=0.99$, P<0.05).

  • PDF

자속구속형 초전도 전류제한기의 용량증대를 위한 동작특성 (Operating Characteristics of Capacity Increase in a Flux-Lock Type Superconducting Fault Current Limiter)

  • 남긍현;최효상;박형민;조용선;이나영;한태희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.200-202
    • /
    • 2006
  • We investigated the operating characteristics of a flux-lock type superconducting fault current limiters according to the number of the serial connection each the superconducting element at the additive polarity winding of a transformer. This SFCL consists of two coils wound in parallel on the same iron core, and the secondary coil is connected to the elements in series. Operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. It turns ratio between the primary and the secondary coils is 63:21. The analysis of voltage, current, and resistance in serial connection each element was performed to increase the applied voltage of flux-lock type SFCL. When the applied voltage was 200/$\sqrt{3}[V_{rms}]$ with three elements connected in seres, the peak value of the line current increased up to 26,24[A]. On the other hands, resistive SFCL increased up to 36.35[A], under the same conditions. This enabled the flux-lock type SFCL to be easy to increase the capacity of power system.

  • PDF

저항성 홀배열이 적용된 볼로미터의 적외선 흡수 특성 변화 (Variation in IR Absorption Characteristics of a Bolometer by Resistive Hole-array Patterns)

  • 김태현;오재섭;박종철;김희연;이종권
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.306-310
    • /
    • 2018
  • In order to develop a highly sensitive infrared sensor, it is necessary to develop techniques for decreasing the rate of heat absorption and the transition of the absorption wavelength to a longer wavelength, both of which can be induced by decreasing the pixel size of the bolometer. Therefore, in this study, $1{\mu}m$ hole-arrays with a subwavelength smaller than the incident infrared wavelength were formed on the amorphous silicon-based microbolometer pixels in the absorber, which consisted of a TiN absorption layer, an a-Si resistance layer and a SiNx membrane support layer. We demonstrated that it is possible to reduce the thermal time constant by 16% relative to the hole-patternless bolometer, and that it is possible to shift the absorption peak to a shorter wavelength as well as increase absorption in the $4-8{\mu}m$ band to compensate for the infrared long-wavelength transition. These results demonstrate the potential for a new approach to improve the performance of high-resolution microbolometers.

자연 산화막과 엑시머 레이저를 이용한 Poly-Si/a-Si 이중 박막 다결정 실리콘 박막 트랜지스터 (Poly-Si Thin Film Transistor with poly-Si/a-Si Double Active Layer Fabricated by Employing Native Oxide and Excimer Laser Annealing)

  • 박기찬;박진우;정상훈;한민구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.24-29
    • /
    • 2000
  • We propose a simple method to control the crystallization depth of amorphous silicon (a-Si) deposited by PECVD or LPCVD during the excimer laser annealing (ELA). Employing the new method, we have formed poly-Si/a-Si double film and fabricated a new poly-Si TFT with vertical a-Si offsets between the poly-Si channel and the source/drain of TFT without any additional photo-lithography process. The maximum leakage current of the new poly-Si TFT decreased about 80% due to the highly resistive vertical a-Si offsets which reduce the peak electric field in drain depletion region and suppress electron-hole pair generation. In ON state, current flows spreading down through broad a-Si cross-section in the vertical a-Si offsets and the current density in the drain depletion region where large electric field is applied is reduced. The stability of poly-Si TFT has been improved noticeably by suppressing trap state generation in drain region which is caused by high current density and large electric field. For example, ON current of the new TFT decreased only 7% at a stress condition where ON current of conventional TFT decreased 89%.

  • PDF

고온초전도 한류기의 전력계통 적용에 관한 연구 (A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter)

  • 배형택;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

Electrical Behaviors of ZnO Elements under Combined Direct and Alternating Voltages

  • Yang, Soon-Man;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.111-117
    • /
    • 2009
  • This paper presents the characteristics of leakage currents flowing through zinc oxide (ZnO) surge arrester elements under the combined direct-current (DC) and 60 Hz alternating-current (AC) voltages. The current-voltage characteristic curves (I-V curves) of the commercial ZnO surge arrester elements were obtained as a function of the voltage ratio a. At constant peak value of the combined DC and AC voltage, the resistive leakage current of the ZnO blocks was significantly increased as the voltage ratio $\alpha$ increased. The I-V curves under the combined DC and AC voltages were placed between the pure DC and AC characteristics, and the cross-over phenomenon in both the I-V curves and R-V curves was observed at the low current region. The ZnO power dissipation for DC voltages was less than that for AC voltage in the pre-breakdown region and reversed at higher voltages.

색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별 (Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography)

  • 이강대;이봉희;이윤우;이환호;안경모;이영수
    • 대한두경부종양학회지
    • /
    • 제17권1호
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF