• Title/Summary/Keyword: resistance force

Search Result 1,434, Processing Time 0.036 seconds

Normalized Contact Force to Minimize "Electrode-Lead" Resistance in a Nanodevice

  • Lee, Seung-Hoon;Bae, Jun;Lee, Seung Woo;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2415-2418
    • /
    • 2014
  • In this report, the contact resistance between "electrode" and "lead" is investigated for reasonable measurements of samples' resistance in a polypyrrole (PPy) nanowire device. The sample's resistance, including "electrode-lead" contact resistance, shows a decrease as force applied to the interface increases. Moreover, the sample's resistance becomes reasonably similar to, or lower than, values calculated by resistivity of PPy reported in previous studies. The decrease of electrode-lead contact resistance by increasing the applying force was analyzed by using Holm theory: the general equation of relation between contact resistance ($R_H$) of two-metal thin films and contact force ($R_H{\propto}1/\sqrt{F}$). The present investigation can guide a reliable way to minimize electrode-lead contact resistance for reasonable characterization of nanomaterials in a microelectrode device; 80% of the maximum applying force to the junction without deformation of the apparatus shows reasonable values without experimental error.

The Parameter Study on the Characteristics of Axial Force in Turnout with Continuous Welded Rail (분기부(分岐部) 장대(長大)레일화시의 축력거동특성(軸力擧動特性) 해석(解析))

  • Kim, Doo-Hwan;Ko, Sang-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.163-174
    • /
    • 2001
  • This paper is to study the characteristics of axial force behavior that operates to the part of turnout when it makes the turnout and the continuous welded rail unifying. The study is to model by using the 50kgN rail No. 15 turnout used in the domestic national railway and the UIC60 rail No. 18 turnout used in the rapid transit railway as the finite elements for analyzing the axial force behavior of the turnout by the continuous welded rail. It is to analyze the characteristics of behavior according to the change of creep resistance, ballast resistance and the change of parameter valuables of heel joint by the axial force simulation in making the continuous welded rail and then, it is to present the result. As the result of research on the parameter valuables through the analysis, it shows that the maximum axial force of turnout by the continuous welded rail are largely subordinated to the maximum resistance of heel joint and the fitting devices than the ballast resistance. Also it shows that the maximum axial force produced changes a lot according to the characteristics of creep resistance of the fitting part and the ballast resistance.

  • PDF

Analysis for Force Distribution on Surface Between Busbar Contacts (부스바 접점 가동시 접촉면에서 압점력 해석)

  • Oh, Y.H.;Song, K.D.;Kim, K.S.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.82-84
    • /
    • 2003
  • In case contact between point of contacts is not achieved well, contact resistance is grown, and by current concentration at current conducting contacts can weld. In order to decrease contact resistance between contacts in case of busbar, installing spring between fixed contact and moving contact. and then force on faying surface of contacts increase and contact resistance decrease. But, in case increase force of spring to widen contact area, operating force moving contact can grow, on the contrary force of spring is small, contact resistance becomes low. Therefore, need to optimize force and number of spring. position, and also need to examine force change on contact surface at point of contact moving. In this paper, dynamic kinetics analysis for force on faying surface of contacts is performed at unsteady state. It is showed to not uniform force on surface between contacts, and we can got more uniform force by means of change spring position.

  • PDF

Experimental Planning for Realistic Force Feedback in a Bicycle Simulator

  • Hun, Yang-Gi;Soo, Kwon-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.117.5-117
    • /
    • 2001
  • This paper presents the key idea of handlebar reaction force and pedal resistance force generation in creating life-like feeling in KAIST bicycle simulator. Also, it provides methods to evaluate its reality level with given reaction force profile. In KAIST bicycle simulator, the pedal resistance force and the handlebar reaction force are calculated using the bicycle dynamic model. With the information handlebar angle, rider´s pedaling torque and road profile transmitted from the handlebar system, the pedal system and the visual part, the bicycle dynamics engine calculates the handlebar reaction force and the pedal velocity. The handlebar system and the pedal resistance system generate reaction force and resistance force transmitted from dynamics engine. However to make more realistic riding feeling ...

  • PDF

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

Measuring Experiment of Resistance Force on a Reciprocating Motion of Rod Type Piston (로드형 피스톤의 왕복운동 저항력 측정실험)

  • 함영복;박경민;김성동;최병오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.486-489
    • /
    • 2003
  • To reduce lateral force of traditional plunger type piston in the swash plate type hydraulic piston pumps and motors, we have proposed rod type piston with ball joint on both ends. We have studied the theoretical reaction force on two types of piston moving in the cylinder block bore. and made an experiment for the resistance force measurement on a reciprocating motion of plunger and rod type piston, changing the test condition such as swash plate angel and supply oil pressure and so on. As a result. a rod type piston has more smaller resistance force, about 29%. than a plunger type one.

  • PDF

Effect of Frictional Resistance Force on a Liquid Pool Spreading Model with Continuous and Instantaneous Release (마찰저항이 연속누출과 순간누출을 가지는 액체 풀의 확산에 미치는 영향에 대한 해석적 연구)

  • Kim, Tae Hoon;Choi, Byung-Il;Kim, Myungbae;Do, Kyu Hyung;Han, Yong-Shik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.487-494
    • /
    • 2013
  • In this study, solutions for a liquid pool spreading model with continuous and instantaneous release are discussed based on the model used in the FERC's report. The effects of the release time on the liquid pool volume and radius are investigated for the continuous release. For the continuous release with the frictional resistance force in the liquid pool spreading model, the vaporization time decreases as the release time increases. On the other hand, for the continuous release without the frictional resistance force in the liquid pool spreading model, the vaporization time increases as the release time increases. These phenomena are deeply related to the pool radius. In addition, the effects of the initial pool radius for the instantaneous release in the liquid pool spreading model are discussed. For the case with the frictional resistance force in the liquid pool spreading model, as reducing release time in the model with the frictional resistance force for the continuous release, the solution for a continuous release approaches to that for an instantaneous release. On the contrary to this, the pool volume and radius for the instantaneous release without the frictional resistance force are totally different from those for the continuous release without the frictional resistance force.

The Study on Inverter DC Resistance Spot Welding Character & Mechanical Property of DP60 Steels (DP60강의 인버터 DC 저항 용접의 용접 특성 및 기계적 성질에 관한 연구)

  • Kim, In-Ju
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12b
    • /
    • pp.604-606
    • /
    • 2011
  • Purpose This study analyzes resistance spot weldability of DP60 steels. Methodology To compare the resistance spot weldability of DP60 steels, tensile strength test and macro-section test were conducted for the resistance spot welds. Acceptable welding conditions were determined as a function of the resistance spot welding process parameters such as electrode force, welding time, and welding current. The lower limit of the welding lobe was the minimum shear tension strength for 590MPa-grade steel while the upper limit was determined whether or not expulsion was detected. Findings Welding force is 200kgf more appropriate in terms of 300kgf the larger the width of the welding zone. Acceptable welding current condition and welding lobe were changed depending on welding force. Research limitations This study is forced on inverter DC resistance spot weldability of 590Mpa-grade steels for automotive application. Practical implications This study confirms the weldability of DP60 steel by comparing resistance spot weldability depending on welding force. Originality This study analysed resistance spot weldability depending on welding force. wedability of DP60 steel were determined by welding lobes.

  • PDF

Microstructural Characteristics of Zircaloy-4 Nuclear Fuel Cladding Welds by Resistance Upset Welding Processes (저항 업셋 용접방식에 따른 Zircaloy-4 핵연료 피복재 용접부의 미세조직 특성)

  • 고진현;김상호;박춘호;김수성
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.98-104
    • /
    • 2002
  • A study on microstructures of welds for Zircaloy-4 sheath end closure by the resistance upset welding methods was carried out. Two upset welding process variations such as magnetic farce and multi-impulse resistance welding were used. Grain size and microhardness across welds were analysed in terms of welding parameters. Magnetic farce resistance weld with one cycle of unbalanced mode has smaller upset length and $\alpha-grain$ size in heat affected zone than those of multi-impulse resistance weld because of lower heat input and shorter welding time. Heat affected zone formed by two upset resistance welding variations revealed fine Widmanstatten structure or martensitic ${\alpha}'$ structure due to the high heating rate and foster cooling rate. Magnetic force resistance welds showed recrystallized grains before grain growth, whereas multi-impulse resistance welds showed full grain growth.

A Study on the Calculation of Towing Force for the Disabled Ship and Its Experiments (사고 선박의 예인력 계산 및 실험에 관한 연구)

  • Nam, Taek-Kun;Jung, Chang-Hyun;Kim, Jin-Man;Choi, Hyuek-Jin
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.463-470
    • /
    • 2014
  • In this paper, calculation of towing force required to tow the ship and experiments to verify its appropriacy are discussed. Friction, wind and wave-making resistance of vessel are considered to calculate towing force of specified vessel. Propeller resistance is also reflected and it is assumed that the propellers are locked. Node analysis to estimate additional resistance on towline is applied. Total towing force could be obtained by adding the ship's resistance and towline resistance. Experiments with training ship SAE YU DAL was executed to check the effectiveness of calculation methods and some comparison between experiments and calculation results was also done. From the comparative analysis, we confirmed that towing speed is primary terms in the calculation of towing force and propeller resistance is a major elements of ship's resistance with the increasing of towing speed. We can see that additional resistance induced by yawing of ship during towing have to be considered for total tow resistance.