• Title/Summary/Keyword: resin-bonded wheel

Search Result 27, Processing Time 0.023 seconds

A STUDY ON THE SHEAR BOND STRENGTH OF THE COMPOSITE RESIN TO AMALGAM ACCORDING TO AMALGAM SURFACE TREATMENT METHODS (아말감의 표면처리에 따른 복합레진과의 전단결합 강도에 관한 연구)

  • Park, Mun-Hee;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.114-121
    • /
    • 1993
  • The purpose of this study was to evaluate the effect on treatment methods to shear bond strength between composite resin and amalgam when the alloy surface was finished with a diamond wheel or an sandblaster. Forty round acrylic cylinders were fabricated with a diameter of 33mm and a height of 20mm to fit into the device used during shear bond strength testing. A round undercut cavity (diameter, 8mm: depth, 2.5mm) was prepared in the center of the acrylic surface and the cavity was restored using a amalgam. A total of 40 acrylic cylinders with amalgam were divided into 4 groups according to treatment method. The group treatment were as follows : Group 1 : acid etching after finishing the amalgam with diamond wheel Group 2 : no acid etching after finishing the amalgam with diamond wheel Group 3 : acid etching after sandblasting the amalgam Group 4 : no acid etching after sandblasting the amalgam The shear bond strength of composite resin bonded to amalgam of each specimen was tested with a universal testing machine at a crosshead speed of 0.5mm/min and 500kg in full scale. The results were as follow: 1. After diamond finishing, the non-acid etching group had highest shear bond strength with 7.29kg/$cm^2$ and after sandblasting, the acidetching group had lowest shear bond strength with 4.49kg/$cm^2$. 2. In both diamond finishing and sandblasting group, acid etching of the roughened amalgam surface decreased the shear bond strength. 3. The group treated with a diamond wheel had higher shear bond strength those treated with an sandblaster but there was not significanat.

  • PDF

Magenetic Properties of Nd-Fe-B-Co-based Melt-spun Ribbons an dTheir Bonded Magents (Nd-Fe-B-Co계 급냉리본과 Bond 자석의 자기적 성질)

  • Gang, Gye-Myeong;Gang, Gi-Won;O, Yeong-Min;Song, Jin-Tae
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.175-184
    • /
    • 1993
  • Abstract Co-and/or AI-added Nd-Fe-B-based magnetic alloys were fabricated by using vacuum induction melting frunace, and melt-spun ribbons were made of the magnetic alloys with single roll rapid quenching method. The variation of magnetic properties of the melt-spun ribbons as a function of Cuwheel velocity (Vs) were investigated. Bonded magnets were made of the optimally quenched ribbon fragments, and the magnetic properties of the melt-spun ribbons and the bonded magnets were studied, relating to the microstructure and crystalline structure. Cu-wheel surface velocity had a strong effect on the magnetic properties of the melt-spun ribbons, and the maximum properties were obtained around Vs =20m/sec. The optimally quenched ribbon had a cellura-type microstructure, in which fine N$d_2$F$e_14$B grains were surrounded by thin Nd-rich phase. In case of a 2.1at% AI-added melt-spun ribbon, the magnetic properties were as follows: iHc, Br, and (BH)max were 15.5KOe, 7.8KG and 8.5MGOe respectively. And resin bonded magnets were fabricated by mixing optimally quenched ribbon fragments with 2.5wt % polyamide resin, compacting and binding at room temperature. The iHc, Br and (BH)max of bonded magnet were lO.2KOe, 4.4KG and 3.3MGOe respectively. And hot-pressed magnets were made by pressing the overquenched ribbons at high temperature. The magnetic properties of hot-pressed magnets were better than those of bonded magnets, and when the holding time was 8 minutes, the iHc, Br, and (BH)max of the hot-pressed magnet were 1O.8KOe, 7.3KG and 8.0MGOe respectively. Domain structure was mainly maze pattern, which means that the easy magnetization axis could be aligned, and the domain width of the hot-pressed magnets was smaller than that of bonded magnets.

  • PDF

A Study on the Mirror Grinding for Mold of a Small Aspherical Lens

  • Lee, Joo-Sang;Masaru Saeki;Tsunemoto Kuriyagawa;Katsuo Syoji
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.4 no.3
    • /
    • pp.48-54
    • /
    • 2003
  • This paper deals with mirror grinding of a small-sized aspherical lens by a resin bonded diamond spherical wheel. Up to now, a spherical lens has been used for the lens of the optical communication optical part. However, recently, aspherical optical parts are mainly used in order to attempt the improvement in image quality and miniaturization of the optical device. It is possible to manufacture the aspherical lens which is presently being used in optical instrument through ultra-precision machining technology. Also, to realize compactness, efforts are being made to produce a micro aspherical lens, fur which the development of a high-precision, micro molding die is inevitable. Therefore, extensive research is being done on methods of producing a micro aspherical surface by high-precision grinding. In this paper, the spherical wheel was trued by cup-shaped truer and tool path was calculated by the radius of curvature of the wheel after truing and dressing. Then in the aspherical grinding experiment, WC material which is used as a melding die for the small-sized aspherical lens was ground. The results showed that a form accuracy of 0.1918 $\mu\textrm{m}$ P-V and a surface roughness of 0.064 $\mu\textrm{m}$ Rmax could be achieved.

A Study on the Mirror Grinding for Mold of a Small Aspherical Lens (소형 비구면 렌즈 금형의 경면 연삭 가공에 관한 연구)

  • Lee, Joo-Sang;Saeki, Masaru;Kuriyagawa, Tsunemoto;Syoji, Katsuo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.82-87
    • /
    • 2001
  • This paper deals with mirror grinding of a small-sized aspherical lens by the resin bonded diamond spherical wheel. Up to now, a spherical lens has been used for the lens of the optical communication optical part. However, recently, the aspherical optical parts are mainly used in order to attempt the improvement in image quality and miniaturization of the optical device. It is possible to manufacture the aspherical lens which is presently being used in optical instrument through ultra-precision machinery technology. Also, to realize compactability, efforts are being made to produce a micro aspherical lens, for which the development of a high-precision, micro molding die is inevitable. Therefore, extensive research is being done on methods of producing an micro aspherical surface by high-precision grinding. In this paper, the spherical wheel was trued by cup-type truer and tool path was calculated by the radius of curvature of wheel after truing and dressing. And then in the aspherical grinding experiment, WC material which is used as a molding die for the small-sized aspherical lens was ground. It results was that a form accuracy of 0.1918${\mu}m$ P-V and a surface roughness of 0.064${\mu}m$ Rmax.

  • PDF

ADAPTATION OF RESIN-MODIFIED GLASS IONOMER CEMENT TO DENTIN (상아질에 대한 광중합형 글라스 아이오노머 시멘트의 접합도)

  • Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.792-800
    • /
    • 1997
  • The purpose of this study was to evaluate the adaptation of self-cured glass ionomer cement and resin-modified glass ionomer cement and polyacid-modified resin composite, which are light-cured giass ionomer cements, to dentin surface. Twelve extracted human maxillary and mandibular molar teeth were used in this study. The entire occlusal dentin surfaces of teeth were exposed with Diamond Wheel Saw and smoothed with sand papers (300, 600, 1200grits). They were randomly assigned into 3 groups according to glass ionomer cements used; Control group- Fuji II, Expeimental group 1 - Fuji II LC, Expeimental group 2 - Dyract. According to the manufacturer's directions, three glass ionomer cements were bonded to exposed dentin surfaces of the tooth crown and cured. Crowns and glass ionomers were trimmed after 24hrs and sectioned horizontally and vertically with diamond saw. The interface of glass ionomer cements and dentin was examined under SEM. The results were as follows : 1. Good adatation between glass ionomer cement and dentin on the horizontal section was showed in control and experimental group 1, but the gap of $20{\mu}m$, which was observed distinct separation between glass ionomer cement and dentin, was showed in experimental group 2. 2. Good adatation between glass ionomer cements and dentin on the vertical section was showed in control and experimental group 1, but the gap of 80-$100{\mu}m$ was showed in experimental group 2. 3. Cohesive fracture within glass ionomer cements in control and experimental group 1 was showed, but no cohesive fracture was showed in experimental group 2.

  • PDF

Minimization of Hydrodynamic Pressure Effect on the Ultraprecision Mirror Grinding

  • Lee, Sun-Kyu;Miyamoto, Yuji;Kuriyahawa, Tsunemoto;Syoji, Katsuo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.59-64
    • /
    • 2005
  • This paper describes an investigation about the fluid delivering method that minimizes the generation of hydrodynamic pressure and improves the grinding accuracy. Traditionally, grinding fluid is delivered for the purpose of cooling, chip flushing and lubrication. Hence, a number of conventional investigations are focused on the delivering method to maximize fluid flux into the contact arc between the grinding wheel and the work piece. It is already known that hydrodynamic pressure generates due to this fluid flux, and that it affects the overall grinding resistance and machining accuracy. Especially in the ultra-precision mirror grinding process that requires extremely small amount of cut per pass, its influence on the machining accuracy becomes more significant. Therefore, in this paper, a new delivering method of grinding fluid is proposed with focus on minimizing the hydrodynamic pressure effect. Experimental data indicates that the proposed method is effective not only to minimize the hydrodynamic pressure but also to improve the machining accuracy.

Evaluation on the Optimum Grinding of Aspheric Surface Micro Lens for Camera Phone (휴대폰 카메라용 비구면 마이크로 렌즈 최적 연삭가공 평가)

  • Baek Seung-Yub;Lee Eun-Sang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 2006
  • As consumers in optics, electronics, aerospace and electronics industry grow, the demand for ultra-precision aspheric surface lens increases higher. To enhance the precision and productivity of ultra precision aspheric surface micro lens, the development of ultra-precision grinding system and process for the aspheric surface micro lens are described. In the work reported in this paper, an ultra-precision grinding system for manufacturing the aspheric surface micro lens was developed by considering the factors affecting the ground surface roughness and profile accuracy. This paper deals with mirror grinding of an aspheric surface micro lens by resin bonded diamond wheel and spherical lens of BK7. The optimization of grinding conditions on ground surface roughness and profiles accuracy is investigated using the design of experiments.

Evaluation of the CNC grinding machine for ultra-precision machining of advanced materials (신소재 경면가공용 CNC 연삭기의 가공성능평가)

  • 김현석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.92-97
    • /
    • 1994
  • The there axis CNC grinding machine tool for ultra-precison mirror surface grinding of advanced materials such as ceramics and other hard and brittle materials was designed and manufactured. The grinding machine is composed of the air spindle, the high damping resin concrete bed, and the three axis CNC controller with the high resolution AC servo motor. To investigate the dynamic properties of the grinding machine, the natural frequencies of the spindle and the headstock were experimentally measured. The truing method using the break truer to revise the shape of the metal bonded diamond wheel was developed. Form the results of the machining using the prototype three axis CNC grinding machine manufactured, the mirror surface were achieved.

  • PDF

Selection of optimal machining condition for productivity enhancement of aspheric surface lens (비구면 렌즈의 생산성 향상을 위한 최적가공조건선정)

  • Baek S.Y.;Lee H.D.;Kim S.C.;Lee E.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.561-562
    • /
    • 2006
  • To enhance the precision and productivity of ultra precision aspheric surface micro lens, the development of ultra-precision grinding system and process for the aspheric surface micro lens are described. In the work reported in this paper, an ultra-precision grinding system for manufacturing the aspheric surface micro lens was developed by considering the factors affecting the grinding surface roughness and profile accuracy. This paper deals with mirror grinding of an aspheric surface micro lens by resin bonded diamond wheel and spherical lens of BK7. The optimization of grinding conditions on ground surface roughness and profiles accuracy is investigated using the design of experiments.

  • PDF

THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN (타액에 오염된 상아질에 대한 콤포머의 접합양상)

  • Cho, Young-Gon;Kim, Byung-Tae;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF