• 제목/요약/키워드: resin bonded bridge

검색결과 12건 처리시간 0.028초

2-unit cantilever 레진접착성 가공의치 (resin-bonded fixed partial denture) 임상의 현재 (CLINICAL PERSPECTIVES ON 2-UNIT CANTILEVERED RESIN-BONDED FIXED PARTIAL DENTURE)

  • 이양진;조리라;박찬진
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Resin-bonded bridge has been an alternative to conventional bridge, since resin-bonded bridge has many attractive advantages such as minimal tooth preparation, short chair time and low cost over conventional bridge. Unfortunately, however, it was reported that resin-bonded bridge showed high failure rate from debonding of retainer in spite of consecutive advances in preparation and materials. And it was shown that multiple abutments were more likely to fail. The majority of debonding failure was considered due to the mobility of the abutment during function. In this view, recently, modification in resin-bonded bridge design was tried. Single retainer, single pontic. 2-unit cantilevered resin-bonded bridge was applied to clinical performance and was shown as retentive or more retentive than fixed-fixed type resin-bonded bridge. This was consistent with the results of studies in 2-unit cantilevered resin-bonded bridges made with all ceramic, In-ceram. The purpose of this article was to overview principles of design and to analyze clinical results of 2-unit cantilevered resin-bonded bridge in comparison with the reports of fixed-fixed resin-bonded bridge.

수종 저 침습 고정성 국소의치의 수직하중에 대한 저항 (Fracture Resistance of Low Invasive Fixed Partial Dentures)

  • 최종인;김유리;신창용;동진근
    • 구강회복응용과학지
    • /
    • 제26권3호
    • /
    • pp.241-251
    • /
    • 2010
  • 본 연구의 목적은 4 종류의 저 침습 고정성 국소의치의 수직하중에 대한 저항을 연구하여 임상 활용에 도움을 주기 위함이다. 상악 우측 제 1 대구치 결손을 가정하여 상악 제 2 대구치와 제 2 소구치를 지대치로 하는 고정성 국소의치 금속 다이를 제작하고 4 종류의 저 침습 고정성 국소의치 (Resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest, Human Bridge with occlusal rest)를 제작하였다. 만능 시험기를 이용하여 수직하중을 가하여 실패 시의 최대 하중을 기록하고 실패 유형을 기록하였다. 평균 최대 하중은 Resin bonded FPD 군이 7,295 N, Two Key Bridge 군이 4,729 N, Human Bridge without occlusal rest 군이 2,190 N, Human Bridge with occlusal rest 군이 3,073 N 이었다. Resin bonded FPD, Two Key Bridge, Human Bridge 군 사이에는 통계학적 유의차가 있었으나 occlusal rest 의 유무에 따른 Human bridge 군 사이에서는 통계학적 유의차가 없었다. 보철물 실패양상은 Resin bonded FPD와 Two Key Bridge는 양측 지대치의 유지부 한쪽이 탈락되는 경우가 양측 모두 탈락되는 경우보다 많았으며 Human Bridge 군은 모두 지대치 양측의 유지부가 함께 탈락되는 경우가 한쪽이 탈락된 경우보다 더 많았다. 본 연구에서 저 침습 고정성 국소의치의 수직 하중에 대한 저항은 Human Bridge 군이 resin bonded FPD 군이나 Two key Bridge 군에 비하여 낮은 것으로 나타났다. 따라서 임상에 적용할 때에는 이와 같은 파절 저항을 고려하여 수복 위치의 최대 교합을 참고하는 것은 물론이고 각종 수복물의 탈락에 대한 저항, 그리고 치질의 삭제량, 환자의 협조도 등을 고려하여 각각의 환자에 적합한 수복물을 선택해야 할 것이다.

하악 4전치 상실시 치료 계획 (Treatment plan for missing mandibular 4 incisors)

  • 한광진
    • 대한심미치과학회지
    • /
    • 제25권1호
    • /
    • pp.25-34
    • /
    • 2016
  • 상실한 하악 4전치에서의 치료 계획은 어느 다른 부위보다 수술의 성공률이나 보철치료시 유리한 환경을 지니고 있다고 흔히 생각되는 부위이다. 하지만 하악 전치들의 M-D 사이즈나 crowding으로 인한 공간적 제한, 임시치아 문제, 치조골 흡수로 인해 생기는 심미적인 문제 등 의외로 까다로운 경우가 종종 발생하는 부위기도 한다. 본문에서는 하악 4전치 상실 시의 치료 계확에 대해서 케이스를 통해 알아 보겠다. 하악 4전치 상실시 가능한 옵션들: 하나 혹은 4전치중 일부 상실의 경우나 잔존 치조골의 흡수가 거의 없어 임플란트 위치 관계가 심미적으로 중요하다고 판단되는 경우라면 직경이 작은 임플란트들을 원래 발치와 중앙에 식립(Narrow type 이나 One body mini implant type) 최종 보철물 형태가 Pink porcelain을 포함하는 이미 광범위한 치조골의 흡수가 일어난 경우 즉 임플란트 식립 위치가 덜 중요한 상황이라면 regular size의 임플란트들을 측절치와 중절치의 사이 Interseptal bone위치에 식립 4전치중 하나 혹은 일부가 상실됐고 남아 있는 전치들의 예후가 불량하다고 의심되나 환자가 당장 나머지 전치들의 발치에는 동의하지 않을 때 남아 있는 전치들이 발치 될 때까지의 Tentative restoration로서 Resin Bonded Bridge(Resin Retained Bridge/Resin Bonded Fixed Partial Denture)의 적용.

상악 전치부 단일치 상실 환자에서 지르코니아 레진접착성 고정성 국소의치를 이용한 수복 증례 (Zirconia resin-bonded fixed partial denture in maxillary single-tooth edentulous area: A case report)

  • 오로지;장희원;김나홍;방주혁;이근우;이용상
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.135-142
    • /
    • 2023
  • 일명 '메릴랜드 브릿지'로 불리는 Resin-bonded fixed partial denture (RBFPD)는 전치부 결손부위를 수복하는데 있어 침습범위를 최소화하는 보존적 보철치료로 잘 정립되어 있다. 하지만 RBFPD의 여러 이점에도 불구하고 높은 탈락률, 비심미성, 지지체 파절 등으로 인해 보편적인 치료방법으로 선택되지는 못하였다. 최근 치과 재료의 발달과 함께 지르코니아가 RBFPD의 새로운 재료로 도입되면서 강도와 심미성이 개선된 전치부 RBFPD의 적용에 적합한 재료로 평가받고 있다. 본 증례는 상악 좌측 측절치를 상실한 환자에서 지르코니아 RBFPD를 수복한 증례로, 전치부에서 비침습적이며 심미적인 보철물을 이용하여 치아상실부위를 수복하였고, 환자와 술자 모두 만족하는 결과를 얻었기에 본 증례를 보고하는 바이다.

Resin-bonded fixed partial denture using In-Ceram and Targis-Vectris system: A clinical report

  • Cha, Young-Joo;Yang, Jae-Ho
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.375-381
    • /
    • 2000
  • The conventional approach for replacing missing maxillary lateral incisors dictates the placement of either a conventional porcelain-fused-to-metal (PFM)bridge, resin-bonded fixed partial denture, or single implant prosthesis. However, several appearance-related disadvantages have been reported in the use of a prosthesis which incorporates a metal substructure. To address these limitations, metal -free restorative alternatives have been recently developed to expand the clinical options when fabrication of these prostheses is indicated. This clinical report describes the treatment of patients with a missing maxillary lateral incisor where the dentition was non-invasively restored with resin-bonded fixed partial denture(RBFPD) using In-Ceram and Targis-Vectris system.

  • PDF

Effect of dentin surface roughness on the shear bond strength of resin bonded restorations

  • Koodaryan, Roodabeh;Hafezeqoran, Ali;Poursoltan, Sajjad
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.224-228
    • /
    • 2016
  • PURPOSE. This study aimed to investigate whether dentin surface preparation with diamond rotary instruments of different grit sizes affects the shear bond strength of resin-bonded restorations. MATERIALS AND METHODS. The buccal enamel of 60 maxillary central incisors was removed with a low speed diamond saw and wet ground with silicon carbide papers. The polished surfaces of the teeth were prepared with four groups of rotary diamond burs with super-coarse (SC), coarse (C), medium (M), and fine (F) grit sizes. Following surface preparation, 60 restorations were casted with nickel-chromium alloy and bonded with Panavia cement. To assess the shear bond strength, the samples were mounted on a universal testing machine and an axial load was applied along the cement-restoration interface at the crosshead speed of 0.5 mm/min. The acquired data was analyzed with one way ANOVA and Tukey post hoc test (${\alpha}=.05$). RESULTS. The $mean{\pm}SD$ shear bond strengths (in MPa) of the study groups were $17.75{\pm}1.41$ for SC, $13.82{\pm}1.13$ for C, $10.40{\pm}1.45$ for M, and $7.13{\pm}1.18$ for F. Statistical analysis revealed the significant difference among the study groups such that the value for group SC was significantly higher than that for group F (P<.001). CONCLUSION. Dentin surface roughness created by diamond burs of different grit sizes considerably influences the shear bond strength of resin bonded restorations.

Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.85-90
    • /
    • 2009
  • STATEMENT OF PROBLEM. Over the years, resin-bonded fixed partial dentures (RBFPDs) have gone through substantial development and refinement. Several studies examined the biomechanics of tooth preparation and framework design in relation to the success rate of RBFPDs and considered retention and resistance form essential for increase of clinical retention. However, these criteria required preparations to be more invasive, which violates not only the original intentions of the RBFPD, but may also have an adverse effect on retention due to loss of enamel, an important factor in bonding. PURPOSE. The object of this in vitro study was to compare the dislodgement resistance of the new types of RBFPDs, the conventional three-unit fixed partial denture, and conventional design of RBFPD (Maryland bridge). MATERIAL AND METHODS. Fifty resin mandibular left second premolars and second molars were prepared on dentiforms, according to the RBFPD design. After model fabrication (five group, n = 10), prostheses were fabricated and cemented with zinc phosphate cement. After cementation, the specimens were subjected to tensile loading at a cross head speed of 4 mm/min in a universal testing machine. The separation load was recorded and analyzed statistically using one-way analysis of variance followed by Duncan's multiple range test. RESULTS. Group V, the pin-retained RBFPDs, had the highest mean dislodgement resistance, whereas specimens of group II, the conventional RBFPDs, exhibited a significantly lower mean dislodgement resistance compared to the other 4 groups (P <.05). There were no significant differences between group I, III, and IV in terms of dislodgement resistance (P>.05). Group V had the highest mean MPa (N/$mm^2$) (P <.05). There was no significant difference between groups I, II, III and IV (P > .05). CONCLUSION. Within the limits of the design of this in vitro study, it was concluded that: 1. The modified RBFPDs which utilizes the original tooth undercuts and requires no tooth preparation, compared with the conventional design of RBFPDs, has significantly high dislodgement resistance (P < .05). 2. The modified RBFPDs which utilizes the original tooth undercuts and requires minimal tooth preparation, compared with the conventional FPDs, has significantly no difference in retention and dislodgement resistance)(P>.05). 3. The pin-retained FPDs showed a high dislodgement resistance compared to the conventional three-unit FPDs (P<.05).

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.