• Title/Summary/Keyword: residential performance

Search Result 637, Processing Time 0.025 seconds

Evaluation on Cooling Performance of Thermally Activated Building System by Insulation and Shading Conditions in Apartments (공동주택의 단열 및 차양에 따른 구체축열시스템 냉방성능 평가)

  • Yoo, Mi-Hye;Yeo, Myoung-Souk;Lee, Yu-Ji;Chung, Woong-June;Park, Sang-Hoon;Kim, Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.23 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Thermally Activated Building System(TABS) is a radiant heating and cooling system which uses structures as thermal storage by embedding pipes in a concrete slab. Using TABS as the cooling system in residential buildings can reduce energy consumption and peak loads. But the ratio of cooling loads handled by TABS is low in the residential buildings which are significantly influenced by outside condition because condensation and over-cooling may occur. However, recent interest on energy-saving buildings is increasing and new residential buildings are expected to be less influenced by outside with high-insulation and shading. In such residential buildings, the heating and cooling loads and the range of load changes reduce. So the ratio of loads handled by TABS can increase. Therefore, this research investigates the cooling performance and energy performance of TABS in the residential buildings with less influence from outside using the simulation.

A Case Study on the Evaluation of Residential Performance for Deteriorated Multi-family Housing (노후공동주택의 거주성능 평가에 관한 사례 연구)

  • Hyun Taek-Soo;Lee Byung-Tae
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.77-85
    • /
    • 2006
  • This study aims to propose the comprehensive evaluation of performance multi-family housing. Most of the existing studies for the reproduction have evaluated by the safety of structure. Therefore those pass over the functional factors which is important for the evaluation of residential qualities. This study represents that the reproduction renovation should not be secured the safety of structure but established the quality of lift. And questionnaire asking expert's opinion also supplemented. As a result, the item for examination and the weight for evaluation are suggested in functional deterioration. The results of this study are summarized as follows: 1. Existent redevelopment criteria are not appropriate to decide the environmental comfort, the vital function of housing and the residential management finance. 2. The future criteria have to evaluate the existing environmental comfort, be reconstructed to put first general deterioration. 3. Evaluation elements was extracted throughout the document research, evaluation elements analysis system was separated in residential area, suburb of dwellings, community, and housing complexity environmental assesment, 4. Each category of influence ratio was extracted to assess total deterioration throughout the expert question survey. 5. Each category analysed (1) $0{\sim}30%$: function is good (unnecessary to improve) (2) $31{\sim}40%$: average (necessary of partial improvement) (3) $41{\sim}59%$: bad (necessary of total improvement) (4) $60{\sim}100%$: the worst (unable to improve throughout the repair)

Earthquake performance investigation of R/C residential buildings in Turkey

  • Korkmaz, Kasim Armagan;Demir, Fuat;Yenice, Tugce
    • Computers and Concrete
    • /
    • v.15 no.6
    • /
    • pp.921-933
    • /
    • 2015
  • The aim of this study is to determine the earthquake performances of reinforced concrete (R/C) residential buildings in Turkey and to analyze the parameters that affect the performance. The performance of Turkish residential buildings, determined by their levels of damage, directly relates to their structural systems. Damage parameters observed from previous earthquakes define structural parameters selected to be used in the present study. Five different types of frame R/C buildings were modeled. For the analysis, the model buildings vary according to the number of stories, column sizes, and reinforcement and concrete strength parameters. The analyses consider gravity forces and earthquake loads through 1975 and 2007 Turkish design codes. In a total of 720 different R/C buildings were investigated for the analysis to obtain capacity curves. A performance evaluation was employed by considering the Turkish design code (TDC-2007). The current study ignores irregularities such as soft stories or short columns. The study's analysis considers a comparison of the parameters' influence on the structural performance of the model buildings.

Alternative Evaluation Model in the Development of Environment-friendly Residential Land (택지개발사업의 환경친화적 대안평가모형 구축)

  • Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.1
    • /
    • pp.156-166
    • /
    • 2009
  • Residential land development projects are tending upwards recently. However, an indiscreet residential land development has tended to damage environment by destroying existing green lands and trees of target lands and generating many cut slopes with transformation of its topography. There are Prior Environmental Review(PER) for district designation and Environmental Impact Assessment(EIA) before approval on development plans. PER is implemented after developing a residential land development plan and EIA is implemented after completing a detail design. As the result, many of residential land development projects are passive to reduce potential environmental problems on the designated sites. Object of this study is to construct an evaluation system on alternatives in the early step of site designation for implementing residential land development projects with environment-friendly and sustainable way. For this, alternative evaluation model is constructed by using Fuzzy Inference and Analytic Hierarchy Process(AHP) method based on Environmental Evaluation Factors of residential land development project, which are proposed in the precedent research. If a decision maker evaluates environment damage by ten-point method, the point is transformed Environmental Performance(EP) by Fuzzy Inference, and then, applying weight that is already calculated by AHP method, Total Environmental Performance(TEP) is calculated. After all, an alternative with the highest TEP is selected as the best one. Using this evaluation system, more than two alternatives of residential land development project site, which can hold location appropriateness in the early under undecided land use plan, can be evaluated quantitatively. As environmental damages, which can be generated by implementing a residential land development project, can be detected in the early step, environmental damages can be removed or reduced at the source.

A Study on the Analysis of Energy Performance of High-rise Residential Buildings (초고층 주거건물의 에너지 성능 분석에 관한 연구)

  • Seok Ho-Tae;Kim Jang-Han;Chung Man-Seok
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • The environment pollution is very important problem. Even at the field of architecture, a study about method of saving energy and constructing environment friendly building will have performed with activity. But trends of Korea housing market are changed that the height of building become more higher and the level of comfort going up. Therefore, these requirements force to increase the energy usage for indoor environmental controls. Thus, the purpose of this study is to reduce the heating and cooling energy requirements of High-rise Residential Buildings by the analysis of Energy Performance. From now on, we search improvement plan for the most efficient Energy Saving at present High-rise Residential Buildings.

Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger (마이크로채널과 핀 튜브 열교환기를 적용한 가정용 에어컨디셔너의 성능 평가)

  • Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • In this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a microchannel condenser is experimentally investigated. A commercially available 7 kW capacity residential air conditioning system having a fin-and-tube condenser served as the base system. The test results show that the system with a microchannel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance is increased by 6% to 10%, and the SEER is increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kPa and the pressure drop across the condenser is decreased by 84%. The microchannel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops.

Necessity for Performance Grade for Residential Structure Waterproofing based on Application Areas - Using AHP Methodology - (공동주택 방수 시공 부위에 따른 성능등급의 필요성 확인 - AHP 분석을 중심으로 -)

  • An, Ki-Won;Oh, Kyu-Hwan;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.21-22
    • /
    • 2021
  • Domestic residential buidling grading is currently comprised of 5 fields; sound-proofing, structure, ambient condition, living environment and fire-proofing. However, factors the take up most of the civil complaints are related to leakage, and waterproofing is not listed as part of the grading system. In particular, the Ministry of Land and Transport claims that the most crucial problems are leakage related in residential structures. Therefore, this study proposes to provide such grading system for waterproofing by AHP methodology based on waterproofing application locations in residential structures.

  • PDF

Effect of Psychological Characteristics on Job Performances of Workers at Residential Homes for the Disabled

  • Seo, Kyung-seok;Cho, Sung-Je
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.4
    • /
    • pp.268-278
    • /
    • 2017
  • The purpose of this research was to analyze the effect of psychological characteristics on job performances of workers at residential homes for the disabled. For the study, a survey was conducted on 170 workers at residential homes for the disabled in Gyeongsangbuk-do (Sangjoo-si, Andong-si and Yecheon-gun) from the 7th of October to 11th of November, 2016. For the analysis, SPSS WIN 18.0 and Amos 21.0 programs were used to conduct t-test, one-way analysis of variance, correlation analysis and multiple regression analysis at a significance level of 5%. The research results were as follows. First, it was found that the psychological characteristics of workers at residential homes for the disabled vary significantly upon their work loads. Second, the differences in job performances of workers at the residential homes for the disabled with their general characteristics were analyzed: it was revealed that the job performance of the workers varies significantly with their education levels, positions and monthly incomes. Third, the job performance of workers at the residential homes for the disabled was found to be having positive correlation with their psychological characteristics as follows: self-esteem (r=.363, p<.001) and self-efficacy (r=.275, p<.001), while having negative correlation with depression (r=-.267, p<.001). This paper is required to be used as a primary source for political development on the enhancement of the psychological characteristics of workers at residential homes for the disabled.

A Study on the Heating Performance of SCW Type Geothermal Heat Pump System for Residential House (지하수 이용 지열 히트펌프 시스템의 주거용 건물 적용시 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.11-18
    • /
    • 2008
  • Geothermal heat pump system using sanding column well type with their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So in the residential house this study estimated heating coefficient of performance (COP) of geothermal heat pump system using sanding column well type which is excellent in heat recovery. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the COP is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster (재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가)

  • Park, Beungyong;Cho, Jinkyun;Jeong, Yongdae;Lee, Wonhak
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.