• Title/Summary/Keyword: residential height

Search Result 144, Processing Time 0.034 seconds

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

Assessment of Hydraulic Behavior and Water Quality Variation Characteristics in Underground Reservoir (지하저수조의 수리적 거동과 수질변화 특성 평가)

  • Lee, H.D.;Bae, C.H.;Kim, J.H.;Hwang, J.W.;Hong, S.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 2005
  • The assessment on characteristics of hydraulic behavior and water quality variations of underground reservoirs of buildings were studied. Firstly, it was thought that underground reservoir capacities($m^3$) of buildings should be not determinated by the uniform and same methods but be estimated on the basis of the dwelling areas on dominated households and their residential characteristics, because these characteristics influence significantly on actual water usages and patterns of buildings. Secondly, it was likely that the average reduction rate of residual chlorine in underground reservoirs were affected from the their capacities, because the average reduction rate of residual chlorine in underground reservoirs under $1,000m^3$ was 43 percent, on the other hand, that rate of underground reservoirs over $1,000m^3$ was 60 percent. Thirdly, through the field investigation, the retention time of drinking water in underground reservoirs were in the range from 0.3 day to 3.9 day. In addition to, the average reduction rate of residual chlorine were depended largely on the retention time of drinking water. When the retention time was under 24 hours, the average reduction rate of residual chlorine was 45 percent, and in case of over 24 hours, was 49 percent. Fourth, water level in underground reservoirs was averagely varied in the range from 0.1 m to 2.65 m at the height of underground reservoirs. If considered actual height of underground reservoirs, 37.6 percent of the height of underground reservoirs was only used. Consequently, the frequency of the inflow and outflow of drinking water in underground reservoir were very increased, and had an effect on the reduction of residual chlorine. Lastly, the investigations on hydraulic structure characteristics of underground reservoirs inside showed the locations of inflow and outflow of drinking water almost were in the opposite direction. And some buildings had several baffles in the middle. Nevertheless, their installations had no beneficial for the improvement of water quality.

Analysis of Land Use Characteristics Using GIS DB - A Case Study of Busan Metropolitan City in Korea - (GIS DB를 이용한 토지이용 특성 분석 - 부산광역시 건물 높이 시뮬레이션을 중심으로 -)

  • Min-Kyoung CHUN;Tae-Kyung BAEK
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.3
    • /
    • pp.52-64
    • /
    • 2023
  • As cities continue to develop rapidly, overcrowding, pollution, and urban sanitation problems arise, and the need to separate conflicting uses is emerging. From this perspective, there is no disagreement that urban land use should be planned. Therefore, all activities in land space must be predicted in advance and planned so that land use can be rationally established. This study used the constructed data to compare and analyze the use distribution characteristics of residential, commercial, and industrial areas in Busan Metropolitan City to identify the building area status, total floor area, and floor area ratio by use zone in districts and counties in Busan Metropolitan City. As a result, it was found that the residential area accounted for the largest proportion of the area by use zone at 51%, and that the residential area accounted for the largest proportion at 63% of the total floor area by use zone. And the analysis was conducted using a specialization coefficient that can identify regional characteristics based on land use composition ratio. Because it is difficult to determine the trend of the entire region just by counting the absolute value of the area, the area composition ratio was calculated and compared. Looking at the residential facilities among the specialization coefficients by use area, it is above 1.0 except for Gijang-gun, Sasang-gu, Saha-gu, and Jung-gu. Commercial facilities are over 1.0 except for Gijang-gun, Gangseo-gu, Nam-gu, Sasang-gu, and Saha-gu. Looking at industrial facilities, you can see that the industrial complex distribution area is Gangseo-gu (2.5), Gijang-gun (1.22), Sasang-gu (2.06), and Saha-gu (1.64). In addition, it was found that business facilities and educational welfare facilities were evenly distributed. Land use analysis was conducted through simulation of the current status of building heights according to each elevation in each use area and the height of buildings in each use area. In general, areas over 80m account for more than 43% of Busan City, showing that the distribution of use areas is designated in areas with high altitude due to the influence of topographical conditions.

Comparison of Nutritional and Physical Status according to the Residental Type among College Women in Seoul Women's University and Sahmyook University (삼육대 및 서울여대 재학 중인 일부 여대생의 거주형태에 따른 영양섭취상태 및 신체계측 비교 연구)

  • Choi, Kyung-Soon;Shin, Kyung-Ok;Huh, Seon-Min;Chung, Keun-Hee
    • Journal of Nutrition and Health
    • /
    • v.43 no.1
    • /
    • pp.86-96
    • /
    • 2010
  • This study was conducted to investigate the effects of residence types ((1) parent house, (2) dormitory or boarding home, (3) boarding home w/o food) on the dietary habits and health status of college women (20-23 y). Overall, 46.1% of college women reported that they were economically middle class and spent 200,000-390,000 won. Additionally, 17.4% of college women considered themselves healthy, while 33.8% reported that they were not healthy. Furthermore, 32.0% of college women had experience to control their weight and 39.8% reported that they exercised to control their weight. There were no significant differences in the height and weight of the subjects according to residential type, but the amount of skeletal muscles mass ($21.0\;{\pm}\;2.6\;kg$) of the subjects that lived in dormitory or boarding home was significantly higher (p < 0.05) than that of women who lived at home. Additionally, 30.8% of students that lived in private residences, 25.0% of students that dwelled in dormitory or boarding homes and 27.7% of students that boarding home w/o food had three regular meals every day (p < 0.05). It has been reported that 18.3% of college students eat processed and instant foods due to their convenience. In the present study, intakes of energy, protein, fat, vitamin A, vitamin $B_1$, vitamin $B_2$, vitamin $B_6$, niacin, vitamin C, vitamin E and folic acid for the subjects who lived in dormitory or boarding homes was significantly higher than those of students who lived in private residences (p < 0.05). Additionally, intakes of iron, calcium, and zinc were lower in the subjects that boarding home w/o food (p < 0.05). Finally, the blood glucose level was $84.7\;{\pm}\;13.0\;mg/dL$, and differed significantly by residential types (p < 0.05); however, the average glucose levels of all subjects were within the normal range (90-110 mg/dL).

Effects of Urban Greenspace on Microclimate Amelioration, $CO_2$ Sequestration and Eire Obstruction (도시녹지의 미기후개선, $CO_2$흡수 및 화재방지의 효과)

  • ;Yoshiteru Nojima
    • Korean Journal of Plant Resources
    • /
    • v.13 no.3
    • /
    • pp.162-170
    • /
    • 2000
  • This study quantified the effects of urban greenspace on microclimate amelioration and atmospheric $CO_2$ reduction for several residential districts selected in Korea and Japan. The study also explored fire obstruction by urban trees to develop systematic planting guidelines. Transpiration by a Zelkova serrata tree (diameter at breast height: 15 cm) in a day of August equaled cooling effect of about 3 air conditioners running for 12 hours. Average air temperature for the growing season was 0.5$^{\circ}C$ and 1.2$^{\circ}C$ cooler, respectively, in districts with 12% and 22% cover of woody plants than in a district with no vegetation. Annual $CO_2$ uptake and $O_2$ production by woody plants were 3 times greater in a district which was 2 times higher in their cover. Woody plants played, in a district with their 22% cover, an important role through offsetting total $CO_2$ emission from the district by about 3% annually, and through producing 10% of annual $O_2$ requirement by all residents within the district. Appropriate planning strategies of residential greenspace, including species selection, planting layout, greenspace enlargement, and maintenance were suggested to improve microclimate amelioration, air purification, and fire obstruction.

  • PDF

Radiation Flux Impact in High Density Residential Areas - A Case Study from Jungnang area, Seoul - (고밀도 주거지역에서의 복사플럭스 영향 연구 - 서울시 중랑구 지역을 대상으로 -)

  • YI, Chae-Yeon;KWON, Hyuk-Gi;Lindberg, Fredrik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.4
    • /
    • pp.26-49
    • /
    • 2018
  • The purpose of this study was to verify the reliability of the solar radiation model and discuss its applicability to the urban area of Seoul for summer heat stress mitigation. We extended the study area closer to the city scale and enhanced the spatial resolution sufficiently to determine pedestrian-level urban radiance. The domain was a $4km^2$ residential area with high-rise building sites. Radiance modelling (SOLWEIG) was performed with LiDAR (Light Detection and Ranging)-based detailed geomorphological land cover shape. The radiance model was evaluated using surface energy balance (SEB) observations. The model showed the highest accuracy on a clear day in summer. When the mean radiation temperature (MRT) was simulated, the highest value was for a low-rise building area and road surface with a low shadow effect. On the other hand, for high-rise buildings and vegetated areas, the effect of shadows was large and showed a relatively low value of mean radiation temperature. The method proposed in this study exhibits high reliability for the management of heat stress in urban areas at pedestrian height. It is applicable for many urban micro-climate management functions related to natural and artificial urban settings; for example, when a new urban infrastructure is planned.

Comparison of behavior of high-rise residential buildings with and without post-tensioned transfer plate system

  • Byeonguk Ahn;Fahimeh Yavartanoo;Jang-Keun Yoon;Su-Min Kang;Seungjun Kim;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • v.31 no.4
    • /
    • pp.337-348
    • /
    • 2023
  • Shear wall is commonly used as a lateral force resisting system of concrete mid-rise and high-rise buildings, but it brings challenges in providing relatively large space throughout the building height. For this reason, the structure system where the upper structure with bearing, non-bearing and/or shear walls that sits on top of a transfer plate system supported by widely spaced columns at the lower stories is preferred in some regions, particularly in low to moderate seismic regions in Asia. A thick reinforced concrete (RC) plate has often been used as a transfer system, along with RC transfer girders; however, the RC plate becomes very thick for tall buildings. Applying the post-tensioning (PT) technique to RC plates can effectively reduce the thickness and reinforcement as an economical design method. Currently, a simplified model is used for numerical modeling of PT transfer plate, which does not consider the interaction of the plate and the upper structure. To observe the actual behavior of PT transfer plate under seismic loads, it is necessary to model whole parts of the structure and tendons to precisely include the interaction and the secondary effect of PT tendons in the results. This research evaluated the seismic behavior of shear wall-type residential buildings with PT transfer plates for the condition that PT tendons are included or excluded in the modeling. Three-dimensional finite element models were developed, which includes prestressing tendon elements, and response spectrum analyses were carried out to evaluate seismic forces. Two buildings with flat-shape and L-shape plans were considered, and design forces of shear walls and transfer columns for a system with and without PT tendons were compared. The results showed that, in some cases, excluding PT tendons from the model leads to an unrealistic estimation of the demands for shear walls sit on transfer plate and transfer columns due to excluding the secondary effect of PT tendons. Based on the results, generally, the secondary effect reduces shear force demand and axial-flexural demands of transfer columns but increases the shear force demand of shear walls. The results of this study suggested that, in addition to the effect of PT on the resistance of transfer plate, it is necessary to include PT tendons in the modeling to consider its effect on force demand.

Comparison of Seedling Survival Rate and Growth among 8 Different Tree Species in Seosan Reclamation Area (서산 간척지에서 8개 교목 수종의 묘목 생육 비교)

  • Park, Pil Sun;Kim, Kyung Yoon;Jang, Woongsoon;Han, Ahreum;Jo, Jaechang;Kim, Jun-Beom;Kim, Jee-han
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.4
    • /
    • pp.496-503
    • /
    • 2009
  • Reclamation area is characterized by high soil salinity and high ground water table that are not favorable environment for tree growth. However, the increasing demand to convert the reclamation area from rice cultivation fields to industrial or residential complex, or parks accompanies the idea of introduction of trees in the area. This study aimed to suggest better performed tree species for the tree planting in the Seosan reclamation area, Chungchungnam-do. Seedlings of 8 tree species (Pinus densiflora, Pinus thunbergii, Metasequoia glyptostroboides, Chionanthus retusus, Cornus kousa, Prunus sargentii, Quercus acutissima, and Zelkova serrata) were planted in 4 types of 10 m ${\times}$ 10 m experimental plots. The survival rate and the height growth of seedlings were measured from April 2006 to November 2008 on an annual basis. The experimental plots were constructed using 2 different soil material (dredged sand and dredged sand + forest soil), and 2 soil covering depth (1.5 m and 2.0 m). The tree species showed different survival rates for 3 years since planting (F = 9.632, P < 0.001). C. kousa, Q. acutissima, and P. sargentii showed high mortality rate while P. thunbergii, M. glyptostroboides and Z. serrata showed lower mortality rates. The seedling height growth for 3 years was also significantly different among species (F=4.749, P=0.002). Most of seedlings showed lower height growth in the second year, and the growth began to recover in the third year after transplanting. The survival rate and the growth of the seedlings were better in higher soil covering depth and forest soil material plots regardless of species. The combination of rank orders in survival rate and relative height growth indicates that P. thunbergii, M. glyptostroboides and Z. serrata would perform better than other species used in the experiment, while C. retusus, C. kousa and P. sargenti may not adapt well to this area.

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

Analysis of Daylight Availability Rights using 3D City-Model (3차원 도시모델을 이용한 건물 일조권 분석)

  • Yoo, Hwan-Hee;Goo, Sin-Hoi;Cho, Eun-Rae;Kim, Seong-Sam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.2
    • /
    • pp.165-175
    • /
    • 2007
  • Nowadays, architecture in urban areas is dominated by the goal of spanning wide spaces and creating openings large enough to distribute daylight to building interiors. Daylight availability of building in city strongly depends not only on the building's height but also on spaces between buildings. Recently numbers of disputes over the daylight availability are increasing in high density developed areas because residents' demand for pleasant residential environment is getting stronger. Therefore in this study we constructed the three-dimensional information of buildings using LiDAR data connected with digital map and then suggested conclusions by applying it to daylight availability analysis. This study presents an approach to judge accurately the violation of a right to enjoy sunshine by using altitude and azimuths of the sun, simulating three-dimensional urban space precisely, and classifying the total duration of sunshine and the continuous duration of sunshine each householder. We expect that local government performs precisely the confirmation and permission business about urban planning and design by advising this approach.