• Title/Summary/Keyword: residential height

Search Result 144, Processing Time 0.019 seconds

A Selection of Representative Type the Korean Peninsula Detached Dwelling for Estimate the Wind Load (풍하중 산정을 위한 한반도 단독주택의 대표유형 선정)

  • Park, Jong-Kil;Jung, Woo-Sik;Choi, Hyo-Jin
    • Journal of Environmental Science International
    • /
    • v.18 no.12
    • /
    • pp.1417-1426
    • /
    • 2009
  • As the damages due to natural disasters continue to increase, a growing interest is being witnessed in such studies that focus on preventive measures to reduce damages rather than on their recovery. As such, the U.S. has been actively conducting projects to develop new models that can forecast potential damages due to natural disasters and widely employing them in actual cases. With no specific models developed in Korea yet, this study aimed to introduce an overseas typhoon model as part of the advanced efforts and apply it the actual cases occurring across the nation. This model estimates wind loads by measuring the impact of a strong wind upon buildings, and measurements require a number of parameters. Those parameters should include the types and dimensions of buildings and the type of the roofs. As for the FPHLM(Florida Public Hurricane Loss Model), a precedent model for our study, we were able to take advantage of number of the statistics and detailed categorizations on the residential buildings in the U.S., which enabled us to select the representative building types and produce their wind loads. With no sufficient relevant statistics available for the nation, however, we may not be able to readily measure the wind loads on the nation's residential buildings. Therefore, this study tried to choose the representative types, heights and dimensions of the buildings for the measurement of wind loads. We consequently came up with a representative house having an area between 62.81 and $95.56m^2$, either a flat roof or hip roof, a height of 2.6 m, an side ratio of 1.5, and the width and length of the mean $85m^2$ sized house being 11,300 mm and 7,530 mm, respectively.

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

Effects of Different Averaging Operators on the Urban Turbulent Fluxes (평균 방법이 도시 난류 플럭스에 미치는 영향)

  • Kwon, Tae Heon;Park, Moon-Soo;Yi, Chaeyeon;Choi, Young Jean
    • Atmosphere
    • /
    • v.24 no.2
    • /
    • pp.197-206
    • /
    • 2014
  • The effects of different averaging operators and atmospheric stability on the turbulent fluxes are investigated using the vertical velocity, air temperature, carbon dioxide concentration, and absolute humidity data measured at 10 Hz by a 3-dimensional sonic anemometer and an open-path $CO_2/H_2O$ infrared gas analyzer installed at a height of 18.5 m on the rooftop of the Jungnang KT building located at a typical residential area in Seoul, Korea. For this purpose, 7 different averaging operators including block average, linear regression, and moving averages during 100 s, 300 s, 600 s, 900 s, and 1800 s are considered and the data quality control procedure such as physical limit check and spike removal is also applied. It is found that as the averaging interval becomes shorter, turbulent fluxes computed by the moving average become smaller and the ratios of turbulent fluxes computed by the 100 s moving average to the fluxes by the 1800 s moving average under unstable stability are smaller than those under neutral stability. The turbulent fluxes computed by the linear regression are 85~92% of those computed by the 1800 s moving average and nearly the same as those computed by 900 s moving average, implying that the adequate selection of an averaging operator and its interval will be very important to estimate more accurate turbulent fluxes at urban area.

Estimation of Velocity Pressure Exposure Coefficient using GIS (GIS를 이용한 풍속고도분포계수 산정)

  • Seong, Min-Ho;Choi, Se-Hyu
    • Spatial Information Research
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 2011
  • As an urbanization is in progress, the change of the planimetric features and topography including high-rise residential buildings commonly occur. The change of the planimetric features and topography causes occurrence of the strong wind and wind speed increase or decrease due to the effect of planimetric features and topography on the windward side even though the wind blows with the same speed. In the design standard, this change by wind speed is defined as the velocity pressure exposure coefficient, the value of coefficient is estimated and reflected by ground surface roughness, but in a reality, ground surface roughness is determined in accordance with the subjective judgement of designer and then the velocity pressure exposure coefficient is estimated, moreover the research and data for classification of ground surface roughness are insufficient. In this paper, we will estimate the velocity pressure exposure coefficient by the quantified method for classifying ground surface roughness by using GIS according to the height of a building targeting area where high-rise residential buildings are built lately. When the structure subjected to wind load is designed, reasonability of design and safety of structure will be more improved by using the estimation method of velocity pressure exposure coefficient presented in this study.

The Comparison of the Body Measurement of Chinese Adult Women by the Age -with the Focus on the Women Residing in Beijing and Shanghai- (중국 성인 여성의 연령별 신체 계측치 비교 -북경과 상해에 거주하는 여성을 중심으로-)

  • Im, Soon;Shon, Hee-Soon;Seok, Hye-Jung
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.6
    • /
    • pp.889-901
    • /
    • 2003
  • The purpose of this study is to look into the physical features for each residential area by the age, with the female subjects residing in Beijing and Shanghai. This would provide the specific information regarding the body types of Chinese adult women, and additionally it would assist the effective advancement into the Chinese local markets by serving as the basic data for the size development and fitting improvement of clothing products for Chinese women. The body measurements were made with 525 adult female subjects of 20 to 49 years of age, residing in Beijing and Shanghai, China. The number of measurements items was 79. The results are as follows: As they grew older, the women residing in Beijing and Shanghai all showed increases in the items of width, thickness, girth, and length, which are highly correlated with the physical obesity, while they did not show any differences by the age range in the item of height. Differences were also found in the tendency of the type distribution by the age range of Chinese adult women in each residential area. As they grew older, the women residing on Beijing showed increases in the distribution of Body type 2 and Body type 4, which clearly indicated the features of obesity. On the other hand, the women residing in Shanghai showed the almost similar distribution in their 20's and 30's, while those in their 40's showed a high frequency in Body type 2 than in Body type 4.

  • PDF

A Simulation for the Stratified Thermal Storage System in Residential Solar Energy Application (주거용 태양열 성층축열시스템의 시뮬레이션)

  • Pak, Ee-Tong;Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.44-52
    • /
    • 1991
  • The benefits of thermal stratification in sensible heat storage systems has been considered and studying by several investigators. In this paper, the basic data which is hard to obtain normally through the experiment were obtainable through the computer simulation. The major objectives of the study were to assess the benefits of stratified storage in residential solar water heating application and to suggest the optimum design parameters. From the computer simulation, following results were obtained. 1. The solar load fraction increases with increasing the number of tank segments. In these simulation, the magnitude of the improvement was about 10%. 2. The solar load fraction increases when the ratio of diameter to height of the tank(H/D) increases to 3, but H/D exceed 3 then, the solar load fraction decreases. In these simulation, the magnitude of the improvement was about 3%. 3. Increasing the collector flow rate slightly improved the performance of the mixed storage system(Node=1). But, for the stratified storage system(Node=N), the solar load fraction increases with decreasing flow rate until the point is reached at which the collector outlet temperature reaches the boiloff limit of $100^{\circ}C$ over some portion of the simulation period.

  • PDF

A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential (주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구)

  • Choi, Doo Chan;Ko, Min Hyeok;Lee, Doo Hee;Park, Kye Won;Choi, Jeong Min;Lee, Yong Kwon;Kim, Gil Nam;Sun, Kyoung Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.890-896
    • /
    • 2021
  • Purpose: The called Aero System is important to find the well detected place in the livingroom or bedroom so, it needs to the confirmation through the Fire Dynamics Simulation Method: A fire simulation of a residential space of 59 m2 was performed, and in order to find the point where the fire environment was exposed quickly, measuring points were installed at 0.6 m and 1.5 m in height for each bedroom and living room, and the point where the fire was quickly detected was confirmed. Result: It was confirmed that the temperature and carbon monoxide sensor set at a point of 1.5 m was quickly detected at the reference value. Conclusion: The Fire detection would be relatively quick if the product in which the fire extinguishing module and the AQI module were separated was installed on the wall.

The Effects of Operational and Mechanical Factors on the Performance of Rice-Husk Furnace (왕겨연소기(燃燒機)의 성능(性能)에 영향(影響)을 마치는 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究))

  • Park, Seung Je;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.39-48
    • /
    • 1983
  • This study was performed to obtain the basic data which could be used for the modification of the manual center-burner-type rice-husk furnace into a small scale automatic type for the multi-purpose use in the farm. For this purpose, first, the utilization feasibility of the rice-husk furnace in the farm was analyzed briefly in aspects of available amount of rice-husk for the fuel, annual operation time and replaceble amount of residential heating energy with rice-husk in the farm. For the experiment a prototype furnace geared with an automatic feeding device was fabricated, and feed rate, mold size and chimney height were changed to investigate the combustion efficiency of rice-husk and thermal efficiency of the furnace. Also, optimum and limiting operational factors were observed in each treatments. The results obtained are summarized as follows. 1. If the rice-husk is intensively used for residential heating in the farm for winter season, on an average 51 percent of the total heating energy can be replaced with the rice-husk. Therefore, development of a small scale automatic rice-husk furnace was recognized to be feasible. 2. The operational condition depending on husk-feed rates was very important factor for successive steady burning operation of the given furnace. When the feed-rate was 1.5 kg/hr, the top of the burning zone should be kept at the position about 55 cm from the bottom of the combustion chamber with the periodic removal of ash (termed as steady state position), which was 18 cm above the mold waist. When the feed rates were 2.4 kg/hr and 3.0 kg/hr, the steady state position was at about 4 cm above the mold waist. 3. The mold size affected inflow rate of air into the furnace and consequently CO content in the exhaust gas. The relatively bigger mold gave positive effect on the air-inflow rate. 4. When the husk-feed rates were 1.5 kg/hr, 2.4 kg/hr, 3.0 kg/hr, the combustion efficiencies of the rice-husk were 98.5%, 97.4% and 95.0%, the thermal efficiencies of the furnace were 93.4%, 93.2% and 87.6%, and CO content in the exhaust gas were 1.21%, 1.03%, and 2.43%, respectively. The air-inflow rates were decreased with the increase of feed rates. When the amount of excess air was 30-40%, the CO content in the exhaust gas was at the minimum level. 5. When the chimney height was lowered from 260 cm to 96 cm, the air-inflow rate was slightly decreased, but the average temperature in the combustion chamber, CO content in the exhaust gas and combustion and thermal efficiencies were not changed significantly. 6. The incidental problems associated with the protytype furnace were accumulation of the ash inside the mold, accumulation of the cinder between the outer-drum of the furnace and the combustion chamber wall, and accumulation of the cinder in the chimney.

  • PDF

A Study on the Correlation between Spatial Distance and Cognitive Intensity of High-rise Buildings - Focusing on High-rise Buildings of More than 30 Stories in Seoul - (초고층 랜드마크의 공간적 거리 및 인지강도와의 상관성 분석 - 서울시 30층 이상 고층건물을 대상으로 -)

  • Byeon, Jae-Sang;Im, Seung-Bin;Joo, Shin-Ha
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.4
    • /
    • pp.90-104
    • /
    • 2007
  • Landmarks like high-rise building are one of the important elements for the enhancement of city identity and provides the hierarchy of city streets, playing a central and symbolic role in cities. Research on physical attribute of landmarks, such as height, distance, location and shape, which are suitable for a city scale, can help a city create a distinct image and maintain comprehensible structure. To achieve this purpose, it is necessary to understand the spatial and cognitive characteristics of a landmark for the establishment and management of it. The results of this study can be summarized as follows: 1. The level of representativeness of a landmark increases in proportion to the degree of cognitive intensity on it. The relation between representativeness and cognitive intensity can be explained as the log-function as follows: Log(the number of people who respond "It has representativeness")=$-1.2579+1.5908{\times}$(cognitive intensity); 2. There are a few differences based on the attributes of respondents: while gender has no distinct influence, residential period and age show statistically meaningful influence on cognitive intensity of a vertical landmark Cognitive intensity of an individual landmarks especially, differs according to the class of main users. Because of frequent changes in occupation or employment, respondents consider the distance from a residential area more important than the distance from a working area in evaluating cognitive intensity of landmarks; 3. landmark can be classified into two kinds: a district landmark and an urban landmark A district landmark is closely connected with physical attributes of the landmark itself, such as distance, size and height. An urban landmark is mainly related to cognitive attributes such as the image and identity of a city as a whole. As a result, the landmark analysis data in this research provides spatial order and identity in a city. It is difficult to establish and reinforce the image of a city as a single element ike a landmark. However, withy steady follow-up research, this study could be seen as a systematic and logical model to improve urban landscape and image.

The Geomorphic Characteristics of the Location of the 4 Traditional Settlements in Youngnam District (영남지방 4대 전통취락의 지형적 입지 특성)

  • Choe, Hee-Man
    • Journal of the Korean association of regional geographers
    • /
    • v.9 no.4
    • /
    • pp.413-424
    • /
    • 2003
  • This study aims to interpret the location of 4 traditional settlements in the Youngnam district of Korea in view of geomorphology. For this study, GIS techniques were used to analyse quantitatively the degree of slope, slope aspect and the relation with river/stream of these regions. Yugok is located on pediment in the valley basin. Cheonjeon is located in the end part of the hill. Hahoe is located on the convex natural levee of the flood plain. Yangdong is located on a hillside. Houses are mostly distributed with south, southeast, and southwest aspect, but in Hahoe face all sides. Also, the settlements are located on average $10{\sim}20m$ above river bed. This indicates a safe height above river bed for avoiding an flood damage. These results imply that the location of the traditional settlement is based on a scientific logic and rationale. It is thus argued that the settlements satisfy exellent geomorphic conditions from the perspective of modern theories of residential location.

  • PDF