• Title/Summary/Keyword: reserve capacity

Search Result 121, Processing Time 0.022 seconds

3D Hierarchical Flower-Like Cobalt Ferrite Nanoclusters-Decorated Cotton Carbon Fiber anode with Improved Lithium Storage Performance

  • Meng, Yanshuang;Cheng, Yulong;Ke, Xinyou;Ren, Guofeng;Zhu, Fuliang
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.285-295
    • /
    • 2021
  • The inverse spinel Cobalt ferrite (CoFe2O4, CFO) is considered to be a promising alternative to commercial graphite anodes for lithium ion batteries (LIBs). However, the further development of CFO is limited by its unstable structure during battery cycling and low electrical conductivity. In an effort to address the challenge, we construct three-dimensional hierarchical flower-like CFO nanoclusters (CFO NCs)-decorated carbonized cotton carbon fiber (CFO NCs/CCF) composite. This structure is consisted of microfibers and nanoflower cluster composited of CFO nanoparticle, in which CCF can be used as a long-range conductive matrix, while flower-like CFO NCs can provide abundant active sites, large electrode/electrolyte interface, short lithium ion diffusion path, and alleviated structural stress. As anode materials in LIBs, the flower-like CFO NCs/CCF exhibits excellent electrochemical performance. After 100 cycles at a current density of 0.3 A g-1, the CFO NCs/CCF delivers a discharge/charge capacity of 1008/990 mAh g-1. Even at a high current density of 15 A g-1, it still maintains a charge/discharge capacity of 362/361 mAh g-1.

Operation Planning of Reserve in Microgrid Considering Market Participation and Energy Storage System

  • Lee, Si Young;Jin, Young Gyu;Kim, Sun Kyo;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1089-1095
    • /
    • 2014
  • Innumerable microgrids would be operated independently by individual operators in a future smart grid. This kind of decentralized power system requires entirely different operation scheme in the actual power system and electricity market operation. Especially, frequency regulation is very important for successive energy trade in this multi-microgrid circumstance. This paper presents an optimal energy and reserve market participation strategy and operation strategy of energy storage system (ESS) by a microgrid operator (MGO). For definite evaluation of the proposed strategy, we postulate that the MGO should participate in the Power Exchange for Frequency Control (PXFC) market, which was devised by Maria Ilic and her coworkers and is suitable to the decentralized operation circumstances. In particular, optimal reserve capacity of the frequency control market and optimal market participation ratio of ESS between frequency control market and energy market are derived theoretically and evaluated by simulations utilizing Nordic Pool Elspot price data.

A Study on the Erection Process Modeling and Simulation considering Variability (변동성을 고려한 탑재프로세스 모델링과 시뮬레이션에 관한 연구)

  • Lim, Hyunkyu;Lee, Yonggil;Kim, Byungchul;Woo, Jonghun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.2
    • /
    • pp.101-107
    • /
    • 2016
  • Generally, the shipbuilding industry has finite resources and limited workspace. Due to finite resources, limited workspace and state of block preparation, erection process in shipbuilding industry is frequently delayed than erection process scheduling which is planned at long-term plan stage. In this study, considering variability of block reserve ratio, the degree of delay in real erection process is measured and compared to scheduling which is planned at long-term plan stage in shipbuilding industry including finite capacity and variative lead time. Also, the erection process scheduling which has minimum lead time can be checked through simulation. The results of this study could be improved the accuracy of erection process scheduling by checking the main event compliance ratio by block reserve ratio and calculating the optimum erection pitch for the main event compliance.

Influence of Home Based Exercise Intensity on the Aerobic Capacity and 1 Year Re-Hospitalization Rate in Patients with Chronic Heart Failure

  • Ryu, Ho Youl;Kim, Ki Song;Jeon, In Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.181-186
    • /
    • 2018
  • Purpose: This study investigated the effects of home-based exercise intensity on the aerobic capacity and 1 year re-hospitalization rate in patients with chronic heart failure (CHF). Methods: Forty seven patients with CHF (males 33, females 14, age $61.3{\pm}9.8years$) participated in this study. The patients were allocated randomly to 3 groups in accordance with home-based exercise intensity: no home based exercise (NHE, 40%, n=19), moderate intensity home-based exercise (MIHE, 43%, n=20), and high intensity home based exercise (HIHE, 17%, n=8). All patients completed the symptom-limited cardiopulmonary exercise (CPX) test safely at the cardiac rehabilitation hospital. Results: The NHE group significantly showed lower peak $VO_2$ and a higher $VE/VCO_2$ slope than the MIHE (p<0.05) and HIHE (p<0.01) groups. On the other hand, the NHE group did not show significant differences in the other hemodynamic responses, such as heart rate (HR) max, HR reserve, maximal systolic blood pressure (SBP), and SBP reserve. Nine out of 19 NHE patients (47%) were re-hospitalized related to heart disease and two out of 20 MIHE (10%) patients were re-hospitalized, but nobody in the HIHE group were re-hospitalized within 1 year from the CPX test. Conclusion: In patients with CHF, home-based self-exercise is one of the important factors for reducing the re-hospitalization rate. In addition, improved aerobic capacity is strongly associated with a lower re-hospitalization rate. In particular, re-hospitalized CHF patients showed significant differences in respiratory parameters and hemodynamic parameters compared to the non-re-hospitalized patients.

A Study on Requirement of Nuclear Power Plant Load Following Operation Condition Considering Power System Security (계통 안전성을 고려한 원자력발전의 부하추종 요건연구)

  • Lee, Hyun-Chul;Baek, Young-Sik;Lee, Geun-Joon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1565-1570
    • /
    • 2012
  • Nuclear power generation is increasing domestic power supply ratio by lower CO2 emission and fuel prices. Currently, nuclear power generator has been operated with maximum power output. Therefore, nuclear power generator could be no effect to managing the reactive power reserve on power system. The reactive power reserve is calculated to the difference between maximum facility and operation generation capacity of the power system. This paper was proposed that load following of nuclear power is control by using 15-bus power system model. In the simulation result, power system is shown to safety state by operating load following of nuclear power generator. This method has be improved the supplied reliability through economic and efficient operation.

Investment Incentive for Capacity Supply in a Period of Introduction of competition (경쟁체제 도입기의 수급안정화를 위한 설비투자 인센티브 설정 연구)

  • Kim, Chang-Soo;Rhee, Chang-Ho;Jin, Byung-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.406-408
    • /
    • 2000
  • Recently, Korea's electric industry is in the midst of a period of profound changes in the structure and function, including the introduction of market competition in the generation sector. Therefore, it is difficult to promote long-term capacity planning and new generating capacity construction which have been driven by KEPCO so far, after the introduction of market competition, so new generating capacity construction and security of reserve margin is needed through self·regulation plan of private generation producers by market mechanism. According to the competition in the generation sector, a new paradigm is necessary to the long-term capacity planning driven by the Government. This paper analyzes the plan and the incentive level able to guide the new generation capacity construction considering the uncertainty risk in a period of introduction of competition. In addition, this paper analyzes the plan able to guide the new capacity construction by market function at the stage which market become established and Government's role to solve the anxiety about the capacity supply and demand.

  • PDF

The Effect of Chest Expansion and Pulmonary Function of Stroke Patients after Breathing Exercise (호흡운동이 뇌졸중 환자의 흉곽 확장과 폐 기능에 미치는 영향)

  • Lee, Jeon-Hyeong;Kwon, Yoo-Jung;Kim, Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.3
    • /
    • pp.25-32
    • /
    • 2009
  • Purpose: This study examined whether breathing exercises might increase the chest expansion and pulmonary function of stroke patients. Methods: Twenty four patients with stroke were assigned randomly into two groups: a combination of diaphragmatic resistive breathing and pursed-lip breathing exercise (CB) group (n=10) and control group (n=14). The CB group completed a 4-week program of diaphragmatic resistive breathing and pursed-lip breathing exercise. The subjects were assessed using the pre-test and post-test measurements of the chest expansion (length for resting, deep inspiration, deep expiration, deep expiration-inspiration) and pulmonary function (forced vital capacity (FVC), forced expiratory volume at one second (FEV1), FEV1/FVC, peak expiratory flow (PEF), vital capacity (VC), tidal volume (TV), expiratory reserve volume (ERV), inspiratory reserve volume (IRV)). Results: A comparison of the chest expansion between the pre and post tests revealed similar rest, deep inspiration, deep expiration, and deep expiration-inspiration lengths in the CB and control groups (p>0.05). A comparison of the pulmonary function between pre and post tests, revealed significant improvements in the FVC, FEV, PEF, VC, IRV, and ERV in the CB group (p<0.05). There was a significant difference in the FVC, FEV1, PEF, VC and IRV between the 2 groups (p<0.05). Conclusion: These findings suggest that breathing exercise should help improve the pulmonary function, such as the volume and capacity. This suggests that the pulmonary functions of stroke patients might be improved further by a continued respiratory exercise program.

  • PDF

A Study on the Effect of Time Lapse After Position Change and Abdominal Band on Pulmonary Function in the Cervical Cord Injuries (척수손상 환자의 자세 변화 후 시간경과와 복대사용이 폐기능에 미치는 영향)

  • Lee, Jae-Ho;Park, Chang-Il;Chon, Joong-Sun
    • Physical Therapy Korea
    • /
    • v.4 no.3
    • /
    • pp.17-33
    • /
    • 1997
  • The objective of this study was to identify pulmonary functional variations in relation to postural changes, lapse after changing position, and the use of abdominal band in the cervical cord injured. The subjects of this study were 19 quadriplegic patients who had been admitted to the department of the Rehabilitation Hospital, College of Medicine, Yousei University, from April, 1997 through May 3, 1997. A spiroanalyzer was used to measure pulmonary function in supine, standing, time after changing position, and recording to the position, application method, and tightness of the abdominal band. The data were analyzed by the repeated measure one-way ANOVA, and Wilcoxon signed rank test. The findings were as follows: 1. All phase of the patients' pulmonary function improved significantly in supine posture in contrast to standing (vital capacity by $0.46{\ell}$ and expiratory reserve volume by $0.09{\ell}$). 2. The longer the time lapsed from supine posture to standing, the patient's expiratory reserve volume, maximum ventilation volume, vital capacity, and forced expiratory volume increased. 3. When the patient lay in supine position, the maximum ventilation volume, vital capacity, and the forced vital capacity increased then the center line of the abdominal band was placed along iliac crest; on the other hand, when the patient was standing, placing the bottom line of the abdominal band along iliac crest increased the maximum ventilation volume, vital capacity, and forced expiratory volume. 4. In placing the abdominal band in the patients, leaving space between the top and bottom lines of the band helped increased in maximum ventilation volume, vital capacity, and forced vital capacity for patient in supine as well as in standing. 5. When placing the abdominal band to patients in supine posture, reducing the length of the band by 2.5% along the patient's waist line increased the patients' vital capacity, while reducing the length by 10% to patients in standing increased the maximum ventilation volume. The abdominal band should be placed in such a way that the bottom part of the band should be more tightly fastened while leaving enough room for a hand to be placed in between the body and the band for the top part of the hand. It should also be noted that in a supine position, the bottom line of the band should be placed along the iliac crest, while in standing, the center line should be placed along the iliac crest. The length of the band should also be reduced by 2.5% of the waist line in supine position, and in standing, the length should be reduced by 10%. It should also be noted that the pulmonary function of the patients should be measured at least 10 minutes after one position change.

  • PDF

Evaluation of Ultimate Pressure Capacity of Wolsong Containment Structure (월성 원자력발전소 격납건물의 극한내압평가)

  • Kwak Hyo-Gyoung;Kim Jae Hong;Kim Sun-Hoon;Chung Yun-Suk
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.183-189
    • /
    • 2005
  • Nuclear containment structure is the last barrier for being secure from any nuclear power plant accident. Even though the safety requirements of nuclear power plant have been focused on removing accidental situations, nuclear containment structure must reserve the sufficient resisting capacity to any accident because it works as the last barrier. The acceptable nuclear containment structure makes possible to limit the effect of internal accidents and to avoid radioactive release. In this study, to conduct the numerical analysis for the structural safety of a containment structure, loss of coolant accident (LOCA) is considered as the basic accidental load, and Wolsong containment structure is considered as a target structure. The CANDU containment structure, such as Wolsong containment structure, is a prestressed concrete shell structure which has dome and is reinforced with bonded tendons. The evaluation of ultimate pressure capacity was conducted by nonlinear analysis of a prestressed concrete containment structure.

  • PDF

A Study on Establishing Operation Mathematical Model for Optimum Capacity Estimation of the ESS Applications for each in the Nationwide Perspective (국가적 관점에서 용도별 ESS 적정용량 산정을 위한 운전수리모델 수립에 대한 연구)

  • Kim, Jung-Hoon;Youn, Seok-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.969-978
    • /
    • 2016
  • Around the world are increasing the demand for ESS. Currently, the domestic is expected to benefit by operating ESS. In the domestic, it is expected to benefit from operations of the installed ESS because of the introduction of ESS less capacity. However ESS capacity to the maximum profit occurs is unknown. ESS is different from the charge-discharge characteristics and the reserve to replace, depending on the application. Therefore, it should be established in accordance with the ESS optimal capacity according to the purpose used because it can maximize the quality and efficiency of the electric energy. To the ESS optimal capacity estimation by the purpose used, It should compare the investment cost caused by ESS facility installation and operation cost caused by operating ESS. In this paper, the operation mathematical model for estimating marginal operation costs established. In operation mathematical model, operating cost is considered fuel cost and no-load cost start-up cost. Because no-load cost and start-up cost are not related to cost and power plant output, there are expressed an integer variable costs as a step function.