• 제목/요약/키워드: research reactor HANARO

검색결과 151건 처리시간 0.031초

초음파센서를 이용한 냉중성자원 수직공 형상측정 (Measurement of the Shape of the Cold Neutron Source Vertical Hole by Ultrasonic Wave Sensor)

  • 박국남;최창웅;심철무
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2167-2173
    • /
    • 2000
  • The HANARO (High-flux Advanced Neutron Application Reactor) has operated since 1995. The Cold Neutron(CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure the exact size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersion ultrasonic technique is considered as the best method to measure the thickness and the diameter. The 4 axis manipulator of the 2 channel of a sensor module was fabricated. The transducer of 10 MHz results in 0.03 nun of resolution. The inside diameter and thickness for 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results showed that the thickness is in the range of 13-6.7 mm and inside diameter is in the range of o 156-165. These data will be a good reference in the design of a cold neutron source facility.

핵연료조사리그 냉각수 유동 모의장치 개발 (Development of Coolant Flow Simulation System for Nuclear Fuel Test Rigs)

  • 홍진태;정창용;허성호;김가혜
    • 대한기계학회논문집A
    • /
    • 제39권1호
    • /
    • pp.117-123
    • /
    • 2015
  • 핵연료 연소시험 도중 핵연료봉에서 발생하는 열을 효과적으로 제거하기 위해서는 핵연료의 발열량을 정확하게 계산하고 충분한 유속을 갖는 냉각수를 순환시켜야 한다. 하나로는 개방형 수조 형태로서 핵연료 연소시험을 위한 별도의 냉각수 순환 루프를 갖추고 있는데, 여기에 핵연료 조사리그를 장착하고 냉각수를 순환시킴으로써 조사중인 핵연료봉의 온도를 일정온도 이하로 유지시킨다. 특히 순환되는 냉각수의 유속이 매우 높은 상태에서 조사리그 내에 부착된 부품이나 센서들이 유체유발 진동에 의해 파손되거나 기능을 상실하는 경우 매우 큰 기회비용을 야기한다. 본 연구에서는 조사리그 부품의 건전성 사전 검토 및 고속 유동에서의 센서 동작 특성에 대한 사전검토를 위해 냉각수 모의 순환장치를 개발하였다.

식도암 치료용 $^{166}Ho$-Stent 개발 (Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer)

  • 박경배;김영미;김경화;신병철;박응우;한광희;정영주;최상무;이종두
    • 대한핵의학회지
    • /
    • 제34권1호
    • /
    • pp.62-73
    • /
    • 2000
  • 목적: 식도암은 종양자체 혹은 주위조직의 침범으로 인한 식도 내강의 협착으로 음식물 섭취가 곤란하고 이에 따른 영양결핍, 면역력 약화등으로 생존율이 매우 낮은 것으로 보고되고 있다. 본 연구에서는 좁아진 식도 내강을 넓혀줄 뿐만 아니라 종양에 방사선 치료도 병행할 수 있는 새로운 형태의 식도암 치료용 방사성 stent를 개발하고자 한다. 대상 및 방법: ${\ulcorner}$하나로${\lrcorner}$ 연구로를 이용하여 금속 stent 외부를 $^{166}Ho$ 동위원소가 함유된 원통형의 방사성슬리브로 덮어 씌운 방사성 stent 어셈블리($^{166}Ho$-SA)를 전 방사능화법과 후 방사능화법에 의하여 제조하였다. 결과: 폴리우레탄 :매트릭스 내에 함유되어 있는 $^{165}Ho(NO_3)_3$$^{166}Ho(NO_3)_3$의 분포도를 전자현미경 사진과 자가방사기록법으로 확인한 결과 이들 화합물이 균일하게 분포되어 있음을 알 수 있었다. 식도의 구조적 특성을 고려한 전산용 기하학적인 모델을 개발하여 식도벽에 전달되는 흡수선량을 평가하였다. 본 연구에서 개발된 방사성 stent를 황견을 대상으로 식도부위에 삽입한 결과 육안적으로 점막층의 함몰이 일어나 식도내강이 넓어짐을 확인할 수 있었다. 결론: 금속 stent 외부에 $^{166}Ho$ 동위원소가 함유된 얇은 원통형 sleeve를 덮어씌워 균일한 방사선을 방출할 수 있는 방사성 stent를 개발하였으며, 이를 좁아진 식도부위에 삽입하면 물리적 압력에 의한 식도 내강의 확장과 함께 서서히 방사선 효과에 의해 종양괴사를 유도함으로 시간이 지남에 따라 종양 크기의 증대에 의한 이차적 폐쇄를 현저히 감소시킬 수 있을 것으로 기대된다.

  • PDF

MACCS2 코드를 이용한 연구용원자로 '하나로' 설계기준사고시 비상대응조치 효과분석 (Analysis of the Effectiveness of Emergency Response Measures during the Design Basis Accident of the Research Reactor 'HANARO' using MACCS2 Code)

  • 이관엽;김종수;이해초;김봉석
    • Journal of Radiation Protection and Research
    • /
    • 제39권2호
    • /
    • pp.109-117
    • /
    • 2014
  • 방사선비상계획은 원자력시설에 대한 사고해석을 통해 산출한 방사선원항과 기상자료에 근거한 선량평가 결과를 기초로 비상계획이 필요한 거리를 산출하고, 비상계획이 필요한 거리 내에 거주하고 있는 거주민에 대한 옥내대피, 소개, 갑상선방호 등의 보호조치 계획을 수립하는 방식으로 이루어진다. 본 연구에서는 연구용원자로 '하나로'에서 가상할 수 있는 최대사고 조건 하에서 부지내외 거주자에 대한 보호조치 전 후의 선량변화를 1년간 기상자료에 기초하여 확률론적으로 평가하고, 국제방사선방호위원회의 2007년 권고에서 제시한, 비상피폭상황에서 보호조치 이후 잔여선량으로 정의된 참조준위 개념을 사용하여, 최적의 보호조치 유형을 도출하였다. 하나로의 경우 최대 가상사고시 최적의 보호조치 유형은 반경 300 m 이내 거주자 소개, 반경 800 m 이내 거주자 옥내대피로 평가되었으며, 갑상선방호는 반경 600 m 이내 거주자에 국한하여 해당되는데 이 지역 거주자가 소개 또는 옥내대피시는 방사능방재요원 외에 필요가 없는 것으로 평가되었다.

연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석 (Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor)

  • 최정운;이선일;박기정;서경우
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제5권2호
    • /
    • pp.135-143
    • /
    • 2017
  • 국내 유일의 연구용원자로인 하나로(Hi-flux Advanced Neutron Application ReactOr)는 다목적으로 중성자를 이용하기 위해 개방형 수조 내 노심이 존재하는 구조이며, 노심에서 발생되는 핵분열 열을 제거하기 위한 일차 냉각계통, 그리고 연결된 유체계통이 구비되어 있다. 원자로 수조 상부 근방에서 진행되는 방사성 작업 시 작업자의 방사능 피폭을 최소화하기 위해 수조고온층계통에 의해 상부에 고온층이 형성되어 있으며, 다소 저온 영역에 있는 방사능 가스 및 이물질이 상부로 올라오는 것을 방지하기 위해 수조수 온도를 $50^{\circ}C$이하로 제한하고 있으며 이를 위해 수조수관리계통이 연결되어 있다. 수조수관리계통의 구비된 판형열교환기의 열용량을 정상운전 조건에서 260 kW가 되도록 설계하여 각 수조에서 발생되는 열원을 제거하는지에 대해 평가하였고, 원자로 운전 모드와 관계없이 정상적으로 유체계통이 운전된다면 각 수조의 수조수 온도는 제한치 이하를 유지하고 있음을 확인하였다.

하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험 (A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor)

  • 황권상;조만순;성형진
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1038-1045
    • /
    • 2000
  • An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.

고방사성 산화물핵연료의 해외수송방안 분석 (The Option Study of Oversea Shipment of DUPIC Fuel Elements to Canada)

  • 이호희;박장진;양명승;서기석
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.614-620
    • /
    • 2003
  • 원자력연구소에서는 국내 원전에서 배출된 사용후핵연료를 IMEF M6 핫셀에서 건식 재가공하여 건식공정 산화물핵연료를 개발하였다. 개발된 핵연료의 성능을 검증하기 위해서는 실제 상용로와 동일한 고온고압 조건하에서 조사시험이 필요하나 국내에는 이러한 조사시설을 갖추지 못하고 있으므로 핵연료 성능의 검증이 어렵던 차에 한$\cdot$$\cdot$미 IAEA간의 국제공동연구 과제진도회의에서 AECL측은 중성자비를 받지 않고 캐나다 NRU에서 건식공정 산화물핵연료를 조사시험을 할 수 있다고 제안하였다. NRU 조사시험을 하고자 하는 핵연료는 건식공정 산화물핵연료봉 10개(약 6kgU)이며 운반물 분류등급에 따라 제7종 위험물로 핵분열성물질에 해당한다. 일반적으로 소량의 방사성물질을 운반할 경우에는 비용뿐 아니라 수송기간 측면에서 항공수송이 선박수송에 비해 유리한 것으로 알려져 있어 항공기를 이용한 건식공정 산화물핵연료의 해외 수송방안을 검토하였다. 검토결과, 현재 건식공정 산화물핵연료봉 10개를 운반할 수 있는 적절한 항공수송용 수송용기가 없어 항공수송이 불가능한 것으로 조사되었다. 선박을 이용한 해외 수송방안은 가능하나 이 경우에는 전용선박을 사용해야 함으로 비용이 많이 수요되는 것으로 분석되었다.

  • PDF

조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구 (A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test)

  • 김웅기;김수성;이철용;이도연;이정원
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

Fluence Monitor를 이용한 HANARO 노심 내 중성자 플루언스 측정 (Neutron fluence measurement at HANARO using fluence monitor method)

  • 이승규;조광호;주기남;박진석;김용균
    • Journal of Radiation Protection and Research
    • /
    • 제36권4호
    • /
    • pp.200-208
    • /
    • 2011
  • Fluence monitor(F/M)는 조사 시편을 원자로의 노심에 넣은 후 방사화 된 조사 시편의 방사능을 측정한 후 역산하여 중성자의 선량을 계산하는 기법으로 원자로내의 중성자 분포를 조사하기 위하여 반드시 필요한 기술이다. 이 기술은 중성자에 대한 에너지 스펙트럼 측정이 간접적으로 가능하며, 현존하는 중성자 분포 측정 기법 중에서 우수한 정밀도를 지니고 있다. 하나로(HANARO)에서 수행하는 재료조사 시험에서의 중성자량 측정을 위하여 본 연구에서는 지름 0.1 mm, 길이 3 mm 미만의 질량 150~200 ${\mu}g$ 범위, 순도 99.9% 이상의 Fe, Ni, Ti 와이어를 F/M 시편으로 사용하였다. 이 시편은 알루미늄 캡슐에 봉입하여 30 MW 의 하나로 OR5공에 약 25일간 조사하였다. 조사를 마친 시편은 high purity germanium (HPGe) detector를 이용하여 감마선을 측정하였고, SAND-II code로 reaction rate와 중성자 cross-section등을 고려하여 fluence monitor 위치에서의 중성자 플루언스를 계산하였다. F/M이 장착 되었던 하나로 OR5공의 중성자 플루언스 값은 MCNP 코드를 이용하여 계산된 결과를 사용하였으며, SAND-II code로 장착된 F/M 위치에서의 중성자 플루언스를 계산하여 적용된 시편의 reaction에 따른 결과값의 차이를 비교 분석하였다.

요르단 연구용원자로 제어봉구동장치의 성능검증시험 (Performance Qualification Test of the CRDM for JRTR)

  • 최명환;조영갑;김정현;이관희
    • 한국소음진동공학회논문집
    • /
    • 제25권12호
    • /
    • pp.807-814
    • /
    • 2015
  • A control rod drive mechanism(CRDM) is a reactor regulating system, which inserts, withdraws or maintains a control rod containing a neutron absorbing material within a reactor core to control the reactivity of the core. The top-mounted CRDM for Jordan Research and Training Reactor(JRTR) with 5 MW power has been designed and fabricated based on the HANARO's experience through KAERI and DAEWOO consortium project. This paper describes the performance qualification test results to demonstrate the operability of a prototype and four production CRDMs during the reactor lifetime. The driving performance, the drop performance and the endurance tests for CRDM are carried out at a test rig simulating the actual reactor conditions. A vibration of internal components due to the coolant flow is also measured using a laser vibrometer. As a result, the CRDMs are driven having a good driving performance without a malfunction between command and output signals for the stepping motor. Also, the pure drop time and the impact acceleration are within 0.72 s and 4.2 g to meet the design requirements, and the vibrational displacement of control rod is measured as maximum $5.2{\mu}m$.