DOI QR코드

DOI QR Code

A Closed Counter-Current Two-Phase Thermosyphon Loop of a Cold Neutron Source in HANARO Research Reactor

하나로 원자로에 설치될 대향 이상 열사이펀 루프에 관한 실험

  • Published : 2000.08.01

Abstract

An experimental study was carried out to delineate the flow characteristics in a closed countescurrent two-phase thermo syphon with concentric tubes. This is to be installed in the HANARO research reactor as a part of a Cold Neutron Source(CNS). In the present investigation, experiments ata room temperature with Freon-II3 as a moderator were performed. Results show that, based on the magnitude of pressure fluctuation, the flow regimes could be divided into 4 distinct ones in the ($V_f,\;Q_i$) plane, where $V_f$ represents the volume of the charged liquid and $Q_i$ the heat load: a stable flow regime, an oscillatory flow regime, a restablized flow regime and a dryout flow regime. For $V_f$>2.5l, the flow is stable at low $Q_i$. However, as $Q_i$ increases, the flow becomes oscillatory and finally restablizes As $V_f$ increases, the oscillation amplitude decreases, reaching to the restablized flow region at low $Q_i$, and the liquid level in the moderator cell remains high. In the oscillatory flow regimes, for a fixed VI; the oscillating period of time varies with $Q_i$, having a minimum value at a certain value of $Q_i$. The heat load, where the oscillating period of time is minimum, decreases as $V_f$ increases.

Keywords

References

  1. 최창웅, 조만순, 이무웅, 손재민, 박선희, 박국남, 양승영, 강병위, 양성홍, 장종화, 이영욱, 장천익 및 조영식, 1996, '내중성자원 개발', KAERI/RR-1728/9
  2. Kumai, T., Sakamoto, M. and Takahashi, H., 1987, 'JRR-3 개조로 냉중성자원 장치를 위한 폐회로 열사이펀 실험 1,' JAERI Report
  3. Kumai, T., Kudo, M., Sakamoto, M., Akutsu, C. and Takahashi, H., 1989, 'JRR-3 개조로 냉중성자원 장치를 위한 폐회로 열사이펀 실험 2,' JAERI Report
  4. Siegwarth, J. D., Olson, D. A., Lewis, M. A., Rowe, J. M., Williams, R. E. and Kopetka, P., 1994, 'Thermal Hydraulic Tests of a Liquid Hydrogen Cold Neutron Source,' NISTIR 5026
  5. Hoffman, H., 1985, 'Natural Convection Cooling of a Cold Neutron Source with Vaporizing Deuterium at Temperatures of 25K,' Natural Convection: Fundamentals and Applications, S. Kaksc, W. Aung, R. Viskanta, eds., Hemisphere Publishing Corp., New York
  6. Tien, C. L., Chung, K. S. and Liu, C. P., 1979, 'Flooding in Two-Phase Countercurrent Flows,' NP-1283 Research Project 1160-1, Topical Report, Dec
  7. Nguyen-Chi, H. and Groll, M., 1981, 'Entrainment or Flooding Limit in a Closed Two-Phase Thermosyphon,' Heat Recovery Systems, 1
  8. EI-Genk, M. S. and Saber, H. H., 1997, 'Flooding Limit in Closed, Two-Phase Flow Thermosyphons,' International Journal of Heat and Mass Transfer, Vol. 40, No.9 https://doi.org/10.1016/S0017-9310(96)00269-4
  9. Kim, C. J., Moon, S. H. and Kang, H. K., 1997, 'A Study on the Pulse Boiling Occuring Inside the Liquid Pool of a Closed Two-Phase Thermosyphon,' KSME Journal, Vol. 21, No. 10, pp. 1254-1261