• Title/Summary/Keyword: replacement method

Search Result 1,405, Processing Time 0.027 seconds

The Adsorption Characteristics by the Optimun Activation Process of PAN-based Carbon Fiber and SO2 Adsorption Characteristics by the Impregnated Nanoparticles (PAN계 ACF의 최적 활성화 공정에 따른 흡착특성과 나노입자 첨착에 의한 SO2 흡착특성)

  • Lee, Jin-Jae;Kim, Young-Chai
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.532-538
    • /
    • 2006
  • The carbonization and activation conditions for the PAN-based ACF of various grade were investigated to obtain the optimun activation condition with high surface area. And the surface properties and the absorption performance of toxic gas for terror were examined toward the PAN-ACF with the highest surface area. In the test results the surface area increased with increase of the activation temperature, but decreased with increase of the carbonization temperature. After carbonization condition ($900^{\circ}C$-15min) and activation condition ($900^{\circ}C$-30 min), we got the ACF with the highest surface area of $1204m^2/g$. In the absorption test of iodine and toxic gas for terror, this ACF showed more excellent absorption performance than the existing carbon-based adsorbent. Also, in order to give the function characteristic for a selective absorption, the stable nanoparticles of the Ag, Pt, Cu, Pd were prepared and impregnated on the PAN-based ACF in replacement of the existing method supporting metal catalysis. And were analyzed the surface characteristics and the $SO_{2}$ adsorption characteristics. In the $SO_{2}$ absorption performance test of the PAN-ACF with the impregnated nanoparticles, it wasn't change breakthrough time of Ag, Pt, Cu nanoparticle supported the PAN-ACF comparing with breakthrough time (326 sec) of the non supported PAN-ACF but Pd nanoparticle supported the PAN-ACF achieved excellent $SO_{2}$ absorption performance which has break-through time 925 sec.

Application of Calculation Method for Reduction Effect of Environmental Impact and Case Studies of the Vehicle Undercover (자동차 언더커버의 환경영향 감축 효과 산정방법 적용 및 사례 연구)

  • Yun, Hyeri;Park, Yoosung;Yu, Mi Jin;Bae, Hana;Lee, Hanwoong
    • Clean Technology
    • /
    • v.24 no.2
    • /
    • pp.135-145
    • /
    • 2018
  • There are various activities for reduction of the greenhouse gasses (GHG) emission around the world. The countries agreed to submit their's individual plans to the United Nations and have operated programs related to the Climate Change, in addition, the enterprises have spontaneously been developed individual calculation methodologies of GHG emission. This paper aims at examining methods for calculating the effect of the reduction of environmental impact, being divided into three categories; international standard, country, enterprise. The reduction effects of environmental impact were compared by applying an existing product of the vehicle undercover and the uni-materialized product and being selected six calculation methods of environmental footprint. There are significant differences according to the evaluation methods of product environmental footprint (PEF) reduction. Main factors of differences are a gap in system boundary, a scope of data collection and the replacement amount standard of existing products. Stakeholders are unreliable in the results of PEF reduction because of the differences in results by each methodology. Therefore, it is necessary to disclose in detail the methodologies of calculating the PEF reduction that relevant people can easily understand, also to enable comparisons of the reduction results by developing the standardization of evaluation methods of PEF in the long term.

An Efficient Management of Network Traffic using Framework-based Performance Management Tool (프레임워크 기반 성능관리 도구를 이용한 효율적인 네트워크 트래픽 관리)

  • Choi Seong-Man;Tae Gyu-Yeol;Yoo Cheol-Jung;Chang Ok-Bae
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.11 no.3
    • /
    • pp.224-234
    • /
    • 2005
  • As the network-related technology develops the number of both Internet users and the usage are explosively increasing. The networking traffic is increasing in the campus as the networking system inside universities, following the trend, adds more nodes and various networking services. Nonetheless, the quality of services for users has been degraded. Accordingly, core problems, which can cause troubles for network management, design and expansion of the network, and the cost policy, has appeared. To effectively cope with the problems with analyses a great number of technicians, tools, and budget are needed. However, it is not possible for mid and small-sized colleges to spend such a high expenditure for professional consulting. To reduce the cost and investment creating the optimized environment, the analyses on the replacement of the tools, changing the network structure, and performance analysis about capacity planning of networking is necessary. For this reason, in this paper, framework-based performance management tools are used for all steps that are related to the subject of the analysis for the network management. As the major research method, the current data in detailed categories are collected, processed, and analyzed to provide the solution for the problems. As a result we could manage the network, server, and application more systematically and react efficiently to errors and degrading of performance that affect the networking tasks. Also, with the scientific and organized analyses the overall efficiency is upgraded by optimizing the cost for managing the operation of entire system.

A Study on Techniques of the construction and Space Structure of Nam-hea city walls (남해읍성의 공간구성과 축조기법에 관한 연구)

  • Kwon, Soon-Kang;Lee, Ho-Yeol
    • Journal of architectural history
    • /
    • v.18 no.5
    • /
    • pp.59-80
    • /
    • 2009
  • The purpose of this study is to investigate the history, space structures, blueprint, and techniques of the construction of Nam-hea city walls. Nam-hea city walls were relocated in 1439 from Whagumhun-Sansung(火金峴山城) to the present site, nearby Nam-hea Um.(南海邑) The city walls were rebuilt after they were demolished during Japanese invasion on Korea in 1592 and their reconstruction was also done in 1757. At present, the city walls only partially remained due to the urbanization of the areas around them. A plane form of the City wall is a square, and the circumference os approximately 1.3km. According to the literature, the circumference of the castle walls is 2,876尺, the height is 13尺, and the width is 13尺 4寸. Hang-Kyo(鄕校). SaGikDan(社稷壇), YoeDan(厲壇), SunSo(船所) which is a harbor, as well as government and public offices such as Kaek-Sa(客舍) and Dong-Hun(東軒) existed inside the castle walls. Inside the castle walls were one well, five springs, one ditch, and one pond, and in the castle walls, four castle gates, three curved castle walls, and 590 battlements existed. The main government offices inside castle walls were composed of Kaek-Sa, Dong-Hun, and Han-Chung(鄕廳) their arrangements were as follows. Kaek-Sa was situated toward North. Dong-Hun was situated in the center of the west castle walls. The main roads were constructed to connect the North and South castle gate, and subsidiary roads were constructed to connect the East and West castle gate. The measurement used in the blueprint for castle wall was Pobaek-scale(布帛尺:1尺=46.66cm), and one side of it was 700尺. South and North gate were constructed in the center of South and North castle wall, and curved castle walls was situated there. One bastion was in the west of curved castle walls and two bastions were in the east of curved castle walls. The east gate was located in the five eighths of in the east castle wall. Two bastions were situated in the north, on bastion in the south, one bastion in the south, and four bastions in the west castle wall. The castle walls were constructed in the following order: construction of castle field, construction of castle foundation, construction of castle wall, and cover the castle foundation. The techniques used in the construction of the castle walls include timber pile(friction pile), replacement method by excavation.

  • PDF

A Study on the Correlation of Hormonal Status with Depression - Anxiety Traits in Menopausal Women (폐경기 여성에서 호르몬 상태와 우울 및 불안 성향간의 상관관계 연구)

  • Seo, Jeong-Seok;Kee, Baik-Seok;Lee, Sang-Hoon;Lee, Jae-Kwang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.96-101
    • /
    • 1996
  • Objects : There has been the controversy that menopause may or may not influence the psychological distresses. The purpose of this study was to investigate the correlation between the hormonal status and traits of depression & anxiety in menopausal women. Method : Among the women attending menopausal clinic. menopausal women, defined as who having a amenorrhea for more than 12 months, were selected as a study group(n=83). The control group(n=73), who visited to screen the cervix cancer with regular menstruation, hod no history of hormone replacement therapy. Individual data were collected by self-reporting questionnaires. Depression state was evaluated by Beck Depression Inventory(BDI) and anxiety state by Stale Trail Anxiety Inventory(STAI), and the female hormones such as E2, FSH, and LH were obtained by blood sampling at visting clinic. Statistically the data were processed by t-test and pearson correlation analysis(p<0.05). Results : 1) The mean age of menopausal was 45.3 years. 2) In menopausal women the scores of BDI & STAI were significantly higher than in control group(p<0.05). 3) There were significant differences between menopausal and control group by E2 & FSH. 4) There was no correlation between female hormonal status and the STAI & BDI scores in both groups. Conclusion : Although menopausal women had more traits of depression & anxiety than control group, it was difficult to insist that the lack of estrogen was the only etiological factor for the traits of depression & anxiety in menopausal period. In further studies, we must consider another factors, including biological, sociocultural, psychological factor, as the cause of psychological symptoms during menopausal period.

  • PDF

Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions (상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구)

  • Park, Kyung-Ah;Jeong, Cheol-Woong;Ryoo, Gyeong-Ho;Park, Kwang-Bum;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.

Design and Properties of Laminating Waterborne PSA for Eco-friendly Flexible Food Packaging (식품연포장용 라미네이트 수성 감압점착제의 친환경적 적용에 대한 연구)

  • Lee, Jin-Kyoung;Shim, Myoung-Sik;Chin, In-Joo
    • Journal of Adhesion and Interface
    • /
    • v.17 no.2
    • /
    • pp.49-55
    • /
    • 2016
  • In this study, we designed an environment friendly, water-based adhesive using the acrylic emulsion method as a replacement for solvent-based adhesives, which are most commonly used in layered laminates for flexible food packaging. We designed adhesives with different combinations of anionic, non-ionic, and phosphoric ester surfactants, and with different concentrations of chain transfer agent (CTA). We also examined the effect of the degree of cross-linking by synthesizing and comparing 8 test group adhesives with different types of functional monomers. Additionally, we synthesized 2 other test group pressure-sensitive adhesives (PSA) using styrene/alpha-methyl styrene/acrylic acid (SAA) semipolymer dispersing agents (with molecular weights of 13,000 g/mol and 8,600 g/mol, respectively) to replace the conventional surfactants. We evaluated whether the 10 test group pressure-sensitive adhesives met the basic physical property criteria required for flexible food packaging by carrying out a physical analysis of their glass transition temperature (Tg), particle size, adhesion, and molecular weight. In our test, 2 test group adhesives manufactured with the combination of anionic and non-ionic surfactants, CTA concentration of 0.2%, and functional monomers of hydroxyethyl acrylate (HEA) and glycidyl methacrylate (GMA) demonstrated molecular weight and flexibility suitable for flexible packaging, with low adhesiveness and small particle size.

A Study on the Changes in Heavy Metal Emissions when Using Mixed Fuel in a Thermal Power Plant (화력발전소의 혼합연료 사용에 따른 중금속 배출량 변화 연구)

  • Song, Youngho;Kim, Ok;Park, Sanghyun;Lee, Jinheon
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.1
    • /
    • pp.63-75
    • /
    • 2018
  • Objectives: The aim of this research is to explore the total heavy metals from a coal-fired power plant burning bituminous coal with wood pellets due to the implementation of the Renewable Portfolio Standard policy (RPS, 10% of electricity from renewable energy resources by 2023). Methods: The research was carried out by collecting archival data and using the USEPA's AP-42 & EMEP/EEA compilation of emission factors for use in calculating emissions. The Monte Carlo method was also applied for carrying out the calculations of measurement uncertainty. Results: In this paper, the results are listed as follows. Sb was measured at 110 kg (2015) and calculated as 165 kg (2019) and 201 kg (2023). Cr was measured at 1,597 kg (2015) and calculated as 1,687 kg (2019) and 1,728 kg (2023). Cu was measured at 2,888 kg (2015) and calculated as 3,133 kg (2019) and 3,264 kg (2023). Pb was measured at 2,580 kg (2015) and calculated as 2,831 kg (2019) and 2,969 kg (2023). Mn was measured at 3,011 kg (2015) and calculated as 15,034 kg (2019) and 23,014 kg (2023). Hg was measured at 510 kg (2015) and calculated as 513 kg (2019) and 537 kg (2023). Ni was measured at 1,720 kg (2015) and calculated as 1,895 kg (2019) and 1,991 kg (2023). Zn was measured at 7,054 kg (2015) and calculated as 9,938 kg (2019) and 11,778 kg (2023). Se was measured at 7,988 kg (2015) and calculated as 7,663 kg (2019) and 7,351 kg (2023). Conclusion: This shows that most heavy metals would increase steadily from 2015 to 2023. However, Se would decrease by 7.9%. This analysis was conducted with EMEP/EEA's emission factors due to the limited emission factors in South Korea. Co-firewood pellets in coal-fired power plants cause the emission of heavy metals. For this reason, emission factors at air pollution control facilities would be presented and the replacement of wood pellets would be needed.

Fire Extinguishing Ability of Binary Gaseous Extinguishing Agents Evaluated by Cup Burner and Numerical Studies (이성분계 가스계소화약제 소화성능의 컵버너실험 및 이론적 고찰)

  • Kwon, Kyung-Ok;Won, Dong-Bin;Choi, Keun-Joo;Kim, Jong-Won;Shin, Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.7-12
    • /
    • 2007
  • The search for a new fire-extinguishing agent with all the desirable properties of halon 1301 has not been successful. To study binary gaseous extinguishing agents instead, one has to determine the extinguishing concentrations for several compositions of a given chemical in an inert gas. This process is expensive and time consuming. The fire suppression efficiencies of gas mixtures of HFC 125 and HFC 227ea with nitrogen as total flooding agents were studied by cup burner method. It was shown that addition of small amounts of those extinguishants to nitrogen can enhance the suppression effectiveness of the inert gas. As expected, the degree of synergism was highest at low concentrations of the chemical. For each binary system, extinguishing concentrations of the pure compounds and one binary data were used to predict the extinguishing concentrations for the entire range of binary composition. The predicted values were very close to experimental data.

  • PDF

A Study on the Smart Home Safety Management System Based on NIALM (NIALM 기반의 스마트 홈 안전관리시스템에 관한 연구)

  • Jeong, Han-Sang;Sung, Kyung-Sang;Oh, Hae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.8
    • /
    • pp.55-63
    • /
    • 2017
  • Due to spatial problems and system size,conventional measurement methods used to acquire the information needed for existing electrical energy and management have been limited to new buildings or areas where replacement is possible. This electric load management method is problematic when applying it to energy and safety management of vulnerable areas or existing homes or offices. The problem with installing a measurement module in every branch is that the system is too large. Even if the measurement module is installed, the type of load is not recognized, and efficient management is not performed. In particular, it is very difficult to apply it to traditional markets and backward facilities in Korea. In this paper, we apply NIALM technology and arc detection technology to solve these problems and verify the feasibility of NIALM for normal arc generation. Also, based on the verification results, we propose a new smart home safety management system that can effectively manage electrical safety and that can be applied to conventional market and existing home safety management systems. The proposed system conducts a comparative performance test with an existing safety management system. In addition, it achieves 95% or more load recognition for four loads, which is impossible in 40% of the existing systems, and the arc detection function was confirmed.