• 제목/요약/키워드: repetition maximum

검색결과 146건 처리시간 0.026초

Efficient Exercise Volume Analysis through Number of Repetitions and EMG Response of Agonist Muscle During the Bench Press

  • Kim, Ki Hong
    • Medical Lasers
    • /
    • 제10권4호
    • /
    • pp.220-228
    • /
    • 2021
  • Background and Objectives In designing a resistance exercise program, intensity, rest, and exercise volume are important. Many studies have been conducted to find the most suitable resistance exercise program incorporating the above, and in particular, many prior studies have been conducted on intensity. This study attempted to determine the effective volume of exercise by analyzing the number of repetitions performed at intensities of 65% one-repetition maximum (1RM) and 75% 1RM during the bench press exercise, and the electromyography (EMG) response of the agonist muscle. Materials and Methods Eight males in their 20s were selected as study subjects and they performed five sets of bench presses at two levels of intensity (65% 1RM, 75% 1RM). The following results were obtained by measuring the number of repetitions and the EMG response according to the exercise intensity and sets during the workout. Results First, the number of repetitions showed a sharp drop from the first set to the third set at 65% 1RM intensity and showed no change in the fourth and fifth sets. At 75% 1RM intensity, the intensity of hypertrophy showed a gradual decrease from the first set to the fifth set. Second, at 75% 1RM exercise intensity, the pectoralis major, anterior deltoid and triceps brachii showed high muscle activity, and the activity of the anterior deltoid continued to increase from the first set to the fourth set at 65% 1RM intensity, and from the first set to the fifth set at 75% 1RM. Conclusion It was found that during the bench press exercise, three minutes of rest at 75% 1RM intensity, five sets of five sets, one minute rest at 65% 1RM intensity, and three sets of the exercise were effective.

Effects of whey protein supplementation prior to, and following, resistance exercise on body composition and training responses: A randomized double-blind placebo-controlled study

  • Park, Yeram;Park, Hun-Young;Kim, Jisu;Hwang, Hyejung;Jung, Yanghoon;Kreider, Richard;Lim, Kiwon
    • 운동영양학회지
    • /
    • 제23권2호
    • /
    • pp.34-44
    • /
    • 2019
  • [Purpose] The composition of protein supplements, the consumption timing immediately before and after resistance exercise training (RET), and the quantity of protein supplementation may be important factors for the im-provement of muscle mass and function. Although these factors should be considered comprehensively for effective improvement of muscular function in protein supplementation, relatively few studies have focused on this area. Therefore, this study was designed to investigate whether a protein blend supplement before and after resistance exercise for 12 weeks would be effective in increasing muscular function. [Methods] In total, 18 participants were randomly assigned to a placebo (PLA) or protein blend supplement (PRO) group. All subjects followed the same training routine 3 times per week for 12 weeks, taking placebo or protein supplements immediately before and after each exercise session. The protein supplement consisted of 40 g of blend protein, including hydrolyzed whey protein. The RET consisted of lower body (barbell squat, dead lift, seated leg extension, and lying leg curl) and upper body (bench press, barbell rowing, preacher bench biceps curl, and dumbbell shoulder press) exercises. A repetition was defined as three sets of 10-12 times with 80% of one repetition maximum (1RM). [Results] Although the PRO group had a lower protein intake in terms of total food intake than the PLA group, the mean changes in muscle circumference, strength, and exercise volume increased, especially at week 12, compared to the PLA group. [Conclusion] These results suggest that the composition and timing of protein intake are more important than the total amount.

정밀 용접용 펄스형 Nd:YAG 레이저 가공기 개발 (Development of a pulsed Nd:YAG laser materials processing system)

  • 김덕현;정진만;김철중;이종민
    • Journal of Welding and Joining
    • /
    • 제9권1호
    • /
    • pp.32-39
    • /
    • 1991
  • A 200W pulsed Nd: YAG laser for fine welding was developed. The important laser parameters such as laser peak power, average power, pulse width, and pulse energy for welding were studied. In order to obtain the sufficient laser power density for welding, thermal lensing effects were analyzed and a laser resonator with laser beam divergence was designed. The power supply unit was designed to support up to 7kW input. The pulse control unit was developed using a GTO thyristor and could control over 100kW input power to obtain 3.5kW peak power laser. Also due to the GTO thyristor the pulse width could be varied continuously from 0.1 to 20 msec and maximum repetition rate was as high as 300pps.

  • PDF

Optimized Channel Coding of Control Channels for Mobile Packet Communication

  • Song, Young-Joon
    • Journal of electromagnetic engineering and science
    • /
    • 제3권1호
    • /
    • pp.50-56
    • /
    • 2003
  • This paper proposes a coding scheme of control channel for mobile packet communication to maximize the minimum Hamming distance, which is based on shifting of basis vectors of Reed Muller code with optimized dynamic puncturing and/or(partial) sequence repetition. Since the maximum likelihood decoding can be performed using the extremely simple FHT(Fast Hadamard Transformation), it is suitable for real time optimum decoding of control channel information with very little complexity. We show applications of the proposed coding method to TFCI(Transport Format Combination Indicator) code in split and normal modes of 3GPP W-CDMA system. We also discuss how this method can reduce rate indication error over AWGN(Additive White Gaussian Noise) as well as fading channels when the proposed coding scheme is applied to 1xEV-DV system of $3^{rd}$TEX> generation partnership project 2(3GPP2) to indicate the data rate transmitted on the reverse traffic channel by a Mobile Station(MS).

혼합모드(I+II)에서 피로 하중에 의한 균열진전 거동 (Crack Growth Behavior by Fatigue Load under Mixed Mode(I+II))

  • 공병채;최성대
    • 한국생산제조학회지
    • /
    • 제21권2호
    • /
    • pp.276-282
    • /
    • 2012
  • This study looked for Mode status of each for fatigue crack growth behavior about the repeat load of mode I and the static load of mode II. The experiment was performed in the state of the repetition frequency of the sine wave 10Hz, the stress ratio 0.1, maximum load 300kg.f, a static load 0, 100, 200, 300kg.f, As the experimental results, in mode of static load, while the load value increases, the crack growth rate is slower as the energy of a crack mixing grows. Mode I and the power mode II get an influence each other in the direction of crack propagation path, but as they eventually get closer to the breaking point of the crack growth, it is dominated by the mode I.

LOW CYCLE THERMAL FATIGUE OF THE ENGINE EXHAUST MANIFOLD

  • Choi, B.L.;Chang, H.;Park, K.H.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.297-302
    • /
    • 2004
  • This paper presents the low cycle thermal fatigue of the engine exhaust manifold subject to thermo-mechanical cyclic loading. As a failure of the exhaust manifold is mainly caused by geometric constraints of the less expanded inlet flange and cylinder head, the analysis is based on the exhaust system model with three-dimensional temperature distribution and temperature dependent material properties. The result show that large compressive plastic deformations are generated at an elevated temperature of the exhaust manifold and tensile stresses are remained in several critical zones at a cold condition. From the repetition of these thermal shock cycles, maximum plastic strain range (0.454%) could be estimated by the stabilized stress-strain hysteresis loops. It is used to predict the low cycle thermal fatigue life of the exhaust manifold for the thermal shock test.

펄스형 eye-safe 레이저를 이용한 거리측정 (Distance measurement using pulsed eye-safe laser)

  • 유병헌;조성학;장원석;김재구;황경현;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.106-109
    • /
    • 2004
  • In this project, we have developed the eye-safe LRF system of 1.54 ${\mu}{\textrm}{m}$ wavelength using OPO. The maximum measured distance was 3.7km in outdoor experiment. We used Nd:YAG (1064nm) as a laser medium. It was applied BBO to construct the system. We also developed a time-counter for the range finder using a method of TOF (time of flight). The counter-clock used at the time counter was 320MHz making resolution within $\pm$1m. Start and stop signals were detected by two channel systems using PIN and APD. The LRF's repetition rate was 4 times per minute. The energy was measured to be over 9mJ. And, pulse-duration was 23ns. Resolution was $\pm$2m at the distance measurement using a target.

  • PDF

LLC 공진형 컨버터를 적용한 의료용 루비 레이저 전원장치 개발 (Development of Medical Ruby Laser Power Supply using LLC Resonant Converter)

  • 김동현;정재훈;김희제
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.924-928
    • /
    • 2014
  • LLC resonant converter is used to control laser power density in ruby laser power supply. Zero voltage switching(ZVS) is implemented to minimize the switching loss by the LLC resonant converter. Laser output power is investigated and experimented by changing the output current. That current is controled by the charging voltage of capacitor. From those results, we obtained the maximum laser output of 1.94J at the discharge current of 860A and the pulse repetition rate of 1Hz.

방전여기 XeCl 엑시머레이저의 제작 및 동작특성 (Development and Operation Characteristics of XeCl Excimer Laser)

  • 진윤식;이홍식;김희제;노영수;김윤택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.268-271
    • /
    • 1993
  • Discharge pumped high power excimer laser is a very useful light source of ultraviolet region. In this paper. the design and operation characteristics of UV pre-ionized discharge pumped XeCl laser are discussed. Maximum output power of 890mJ at the efficiency of 1.4% was achieved with 35kV charging voltage, 3.4atm of total pressure and 10pps of pulse repetition rate. Optimum HCl pressure is considered to be between 2.5 and 3.5torr.

  • PDF

작업 요인이 push-pull strength와 근육 동원 패턴에 미치는 영향 (Effect of various work factors on push-pull strength and muscle recruitment pattern)

  • 심정훈;이상도
    • 산업경영시스템학회지
    • /
    • 제25권4호
    • /
    • pp.46-53
    • /
    • 2002
  • Push-pull strength has been found to be associated with various work factors such as height, distance, repetition, duration, posture and individual factors. Therefore, this study was performed to investigate the effect of various work factors on push-pull strength and muscle recruitment pattern. Work factors were consisted of grip height(elbow, shoulder), grip distance(100%, 50%, and 25% of maximum grip distance) and shoulder angle(neutral($90^{\cire}$), and abduction($45^{\cire}$, $0^{\cire}$)) during sitting work. The results showed that the normalized strength and EMG value were higher at the elbow height than the shoulder height, and increased with grip distance and shoulder adduction. The results of ANOVA showed that there was significant difference on muscle recruitment patterns among the task conditions. Therefore, it is necessary to consider work factors as well as strength to prevent workers from work-related injuries.