• 제목/요약/키워드: repeatability error

Search Result 157, Processing Time 0.022 seconds

Constitutional Classification between Tae-eumin and Soyangin Types by Measurement of the Friction Coefficient on the Skin of the Human Hand (손등 피부 마찰계수를 이용한 태음인과 소양인 간의 체질구별)

  • Song, Han-Wook;Park, Yon-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.52-61
    • /
    • 2010
  • The use of the friction coefficient is known to provide good discrimination ability in the classification of human constitutions, which are used in alternative medicine. In this study, a system that uses a multi-axis load cell and a hemi-circular probe is designed. The equipment consists of a sensor (load cell type, manufactured by the authors), an x-axis linear-bush guide motorized mobile stage that supports the hand being analyzed, and a signal conditioner. Using the proposed system, the friction coefficients from different constitutions were compared, and the relative repeatability error for the friction coefficient measurement was determined to be less than 2 %. The direction along the ring finger line was determined to be the optimum measurement region for a constitutional diagnosis between Tae-eumin and Soyangin types using the proposed system. There were some differences in the friction coefficient between the two constitutions, as reported in ancient literature. The proposed system is applicable to a quantitative constitutional diagnosis between Tae-eumin and Soyangin types within an acceptable level of uncertainty.

Design and manufacture of eyeball protrusion measuring device using white light scanning interferometer (백색광 간섭계를 이용한 안구 돌출 측정 장치 설계 및 제작)

  • Chang, Jung-soo;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2019
  • The relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure eyeball protrusion values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In this paper, we designed and fabricated a protrusion measuring device using a white light interferometer and measured the protrusion of the human eye and found that the precision and repeatability were significantly higher than the manual measurement method.

Study on Performance Variation of Machine Vision according to Velocity of an Object and Precision Improvement by Linear Compensation (측정물의 속도에 따른 머신비젼의 성능변화와 선형보상에 의한 정밀도 향상)

  • Choi, Hee-Nam;Kang, Bong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.903-909
    • /
    • 2018
  • In this paper, performance analysis of machine vision techniques is presented to improve the convenience and speed of automatic inspection in the industrial field when machine vision is applied to the image not taken in the stationary state, but in the moving state on a conveyer. When the length of cylindrical rods used for automobiles was measured using the edge detection method, the conveying speed increased, and the uncertainty of the boundary between the background and the part image increased, which resulted in a shorter image of the object taken. This paper proposes a linear compensation method to predict the biased errors of the length measurements after examining the pattern of biased and random errors, respectively, with 6 different types of specimens and 7 velocity stages. The length measurement corrected by the linear compensation method had the same accuracy as the stationary state within the speed range of 30 cm/s and could enhance the application capability in automatic inspections.

Estimation of co-variance components, genetic parameters, and genetic trends of reproductive traits in community-based breeding program of Bonga sheep in Ethiopia

  • Areb, Ebadu;Getachew, Tesfaye;Kirmani, MA;G.silase, Tegbaru;Haile, Aynalem
    • Animal Bioscience
    • /
    • v.34 no.9
    • /
    • pp.1451-1459
    • /
    • 2021
  • Objective: The objectives of the study were to evaluate reproductive performance and selection response through genetic trend of community-based breeding programs (CBBPs) of Bonga sheep. Methods: Reproduction traits data were collected between 2012 and 2018 from Bonga sheep CBBPs. Phenotypic performance was analyzed using the general linear model procedures of Statistical Analysis System. Genetic parameters were estimated by univariate animal model for age at first lambing (AFL) and repeatability models for lambing interval (LI), litter size (LS), and annual reproductive rate (ARR) traits using restricted maximum likelihood method of WOMBAT. For correlations bivariate animal model was used. Best model was chosen based on likelihood ratio test. The genetic trends were estimated by the weighted regression of the average breeding value of the animals on the year of birth/lambing. Results: The overall least squares mean±standard error of AFL, LI, LS, and ARR were 375±12.5, 284±9.9, 1.45±0.010, and 2.31±0.050, respectively. Direct heritability estimates for AFL, LI, LS, and ARR were 0.07±0.190, 0.06±0.120, 0.18±0.070, and 0.25±0.203, respectively. The low heritability for both AFL and LI showed that these traits respond little to selection programs but rather highly depend on animal management options. The annual genetic gains were -0.0281 days, -0.016 days, -0.0002 lambs and 0.0003 lambs for AFL, LI, LS, and ARR, respectively. Conclusion: Implications of the result to future improvement programs were improving management of animals, conservation of prolific flocks and out scaling the CBBP to get better results.

New Reliability Criteria for Korean Workers' Health Examination Spirometry Results (근로자건강진단 폐활량검사에서 새로운 신뢰성기준 적용 결과)

  • Yong Lim WON;Hwa-Yeon LEE;Jihye LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.276-283
    • /
    • 2023
  • The Occupational Safety and Health Research Institute is currently evaluating spirometry tests used for worker health examinations by applying the 2005 American Thoracic Society (ATS) and European Respiratory Society (ERS) spirometric test standardization guide and reviewing the application of the 2019 ATS/ERS guide. To compare results obtained using the new evaluation criteria with previous results and determine whether it is appropriate to apply them to Korean workers' health examinations, we reviewed spirometry results from 325 special health examination institutions. Although evaluation criteria such as extrapolation volume, correction error, and forced inspiratory vital capacity were applied more strictly, institutions had higher reliability scores. Primarily because the acceptability and repeatability of forced expiratory volume in 1 second and forced vital capacity were judged separately, and thus, deduction width was reduced. The study shows that adopting the new evaluation criteria would reduce the possible use of inappropriate data, increase tester and doctor understanding of result selection and interpretation, increase result reliability, and reduce the testing burden.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

Interobserver and Intraobserver Reproducibility of SUL Measurements in Reference Organs on FDG PET/CT (FDG PET/CT 검사 시 참고장기에서 측정한, 제지방체중으로 표준화한 표준화 섭취계수의 관찰자 사이 및 관찰자 내 재현성에 대한 연구)

  • Kim, Seong Su;Shin, Yong Cheol;Lee, Sun Do;Lee, Nam Ju;Kim, Jong Cheol;Lee, Chun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • Purpose: The use of SUV which should be normalized by lean body mass (LBM) is recommended for PET response criteria in solid tumors. LBM which was determined by whole body CT was used for SUV normalization (SUL) in this study. The purpose of the present study was to assess interobserver and intraobserver reproducibility of SUL measurements in reference organs. Materials and Methods: F-18 FDG PET/CT was conducted on 52 subjects and LBMs were directly determine by whole body CT for normalization of SUV. The 3 cm diameter spherical VOI, $1\times2$ cm cylindrical VOI, 2 cm diameter spherical VOI were placed in the liver, descending aorta and spleen, respectively. Experienced two observers measured SULmax and SULmean in each organ. Repeated measurements were conducted two weeks apart by observer 1 blind to previous results. Similarly, measurements were conducted on the same patients by observer 2. For assessing reproducibility(or repeatability), the paired t-test, Pearson's correlation coefficients (CC), and technical error of measurement (TEM) were calculated. Results: For interobserver reproducibility in liver SULmax and SULmean, no significant differences were found between observers(paired t-test, P=0.536, 0.293, respectively). CC and TEM for liver SULmean were 0.909 (P=0.000) and 0.067 SUL unit, respectively. Corresponding figures for liver SULmax were 0.882 (P=0.000) and 0.117 SUL unit, respectively. For intraobserver reproducibility in liver SULmax and SULmean, no significant differences were observed within observer1 (paired t-test, P=0.374, 0.268, respectively). CC and TEM for liver SULmean were 0.924 (P=0.000) and 0.061 SUL, respectively. Corresponding figures for liver SULmax were 0.908 (P=0.000) and 0.104 SUL, respectively. Similarly, no significant differences were found in SULmax and SULmean of the spleen and aorta between observers. Conclusion: The current study demonstrated that both SULmean and SULmax measurements in normal reference organs are highly reproducible. Reproducibility of SULmean in reference organs were slightly better than SULmax. Interobsever technical error of measurement was less than 0.10 SUL unit for liver SULmean, and 0.12 SUL unit for liver SULmax. Intraobsever technical error of measurement was less than 0.07 SUL unit for liver SULmean, and 0.11 SUL unit for liver SULmax.

  • PDF

Determination of Natural Gas Components by Gas Chromatographic Multicolumn System (기체 크로마토그래피 복합컬럼 시스템에 의한 천연가스 성분의 정량)

  • Choi, Yong-Wook;Choe, Kun-Hyung
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.339-347
    • /
    • 1994
  • A multicolumn system consisted of two valve(10-port and 6-port valve)-three column (28% DC 200, SP 1700 and Chromosorb 102 column) was developed. Nine natural gas components composed of $N_2$, $CH_4$, $CO_2$, $C_2H_6$, $C_3H_8$, $i-C_4H_{10}$, $n-C_4H_{10}$, $i-C_5H_{12}$$n-C_5H_{12}$ completed all the baseline separation within 18 minutes. The accuracy and the precision of this system was tested. The retention times and the peak areas were determined with a repeatability between 0.02 and 0.16%, and less than 1%, respectively. Calibration curves for natural-gas components were plotted by the partial pressure injection method of pure gases, and good linear relationships for each component were presented. By using these calibration curves the accuracy of the multicolumn system compaired with that of the single column system for a certified standard gas of natural gas. As a result, relative error in the single and the multicolumn system was less than 0.5% and 0.04%, respectively. The result of application of this system in the analysis of importing LNG composition showed that the heating values calculated by the multicolum system were estimated lower compared with those calculated by the single column system and consequently, the importing price of LNG was able to be cut down.

  • PDF

Comparison of Predicted and Measured ASF (ASF 예측치와 실측치 비교)

  • Shin, Mi-Young;Hwang, Sang-Wook;Yu, Dong-Hui;Park, Chan-Sik;Lee, Chang-Bok;Lee, Sang-Jeong
    • Journal of Navigation and Port Research
    • /
    • v.34 no.3
    • /
    • pp.175-180
    • /
    • 2010
  • In the almost application parts, GNSS being used the primary navigation system on world-widely. However, some of nations attempt or deliberate to enhance current Loran system, as a backup to satellite navigation system because of the vulnerability to the disturbance signal. Loran interests in supplemental navigation system by the development and enhancement, which is called eLoran, and that consists of advancement of receiver and transmitter and of differential Loran in order to increase the accuracy of current Loran-C. A significant factor limiting the ranging accuracy of the eLoran signal is the ASF in the TOAs observed by the receiver. The ASF is mostly due to the fact that the ground-wave signal is likely to propagate over paths of varying conductivity and topography. This paper presents comparison results between the predicted ASF and the measured ASF in a southern east region of Korea. For predicting ASF, the Monteath model is used. Actual ASF is measured from the legacy Loran signal transmitted Pohang station in the GRI 9930 chain. The test results showed the repeatability of the measured ASF and the consistent characteristics between the predicted and the measured ASF values.

Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors (공압 실린더 액츄에이터 위치제어)

  • Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won;Park, Jong-Min;Kwon, Soon-Goo;So, Jung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.