Browse > Article
http://dx.doi.org/10.6109/jkiice.2019.23.1.63

Design and manufacture of eyeball protrusion measuring device using white light scanning interferometer  

Chang, Jung-soo (Department of Bio Medical Engineering, Ajou University)
Kim, Young-kil (Department of Electronic Engineering, Ajou University)
Abstract
The relative position of the orbital eye can be a criterion for evaluating several pathological conditions. It is especially useful to diagnose orbital fractures, thyroid eye disease, orbital tumors and to evaluate the outcome of medication and surgical treatment. Hertel and Naugle are representative measurement tools used to measure eyeball protrusion values, and have different measurement results, such as fixed orbits, every time they are inspected, even if the same inspector repeatedly measures them. Even with the same calibrator, it is inevitable that different manufacturers will change the design of the stationary part of the orbit, causing the surveyor to make a measurement error. In this paper, we designed and fabricated a protrusion measuring device using a white light interferometer and measured the protrusion of the human eye and found that the precision and repeatability were significantly higher than the manual measurement method.
Keywords
Exophthalmometric values; White light Scanning Interferometer; Image processing; Inspection System;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 K. H. Kook, Y. K. Kim, and S. Y. Lee, "Exophthalmometric values of Korean using Hertel and Naugle exophthalmometers," Opthalmological Society, vol. 44, no. 1, pp. 10-15, 2003.
2 J. H. Yum, S. K. Choi, J. H. Kim, and D. H. Lee, "Comparison of Aberrations in Korean Normal Eyes Measured With Two Different Aberrometers," Opthalmological Society, vol. 50, no. 12, pp. 1789-1794, 2009.
3 J. H. Hwang, S. Y. Lee, and S. J. Kim, "Comparison of Reproducibility between Exophthalmometer Readings Measured with Hertel and Naugle Exophthalmometer," Opthalmological Society, vol. 40, no. 2, pp. 293-298, 1999.
4 E. Nkenke, M. Benz, T. Maier, J. Wiltfang, L. M. Holbach, M. Kramer, G. Hausler, F. W. Neukam, "Relative en- and exophthalmometry in zygomatic fractures comparing optical non-contact, non-ionizing 3D imaging to the Hertel instrument and computed tomography," Journal of Cranio-Maxillofacial Surgery, vol. 31, no. 6, pp. 362-368, 2003.   DOI
5 J. S. Chang, Y. K. Kim, "Exophthalmometric values using White-light Scanning Interferometer," Journal of the Korea Institute of Information and Communication Engineering, vol. 21, no. 12, pp. 2341-2346, Dec. 2017.   DOI
6 S. H. Lee, K. W. Ko, K. C. Ko, S. Y. Cho, "Development of White Light Scanning Interferometry Autofocusing Equipment for LCD part Inspection," Proceedings of the Korean Society of Precision Engineering Conference, pp. 3-4, 2006.
7 I. B. Chyun, K. N. Joo, "Sub-sampling Technique to Improce the Measurement Speed of White Light Scanning Interferometry," Journal of the Korean Society for Precision Engineering, vol. 31, no. 11, pp. 999-1006, Nov. 2014.   DOI
8 K. W. Ko, J. H. Sim, and M. Y. Kim, "A High-Speed White-Light Scanning Interferometer for Bump Inspection of Semiconductor Manufacture," Journal of the Korean Society for Precision Engineering, vol. 30, no. 7, pp. 702-708, Jul. 2013.   DOI
9 Y. S. Ghim, A. Davies, and H. G. Rhee, "Accuracy Improvement and Systematic Bias Analysis of Scanning White Light Interferometry for Free-form Surfaces Measurements," Journal of the Korean Society for Precision Engineering, vol. 31, no. 7, pp. 605-613, Jul. 2014.   DOI
10 Y. M. Goo, K. H. Lee, "Flip Chip Bump 3D Inspection Equipment using White Light Interferometer with Large F.O.V.," Journal of the Korean Institute of Intelligent Systems, vol. 23, no. 4, pp. 286-291, Aug. 2013.   DOI
11 N. Arora, M. Martolia, A. Ashok, "A Comparative study of the Image Registration Process on the Multimodal Medical Images," Asia-pacific Journal of Convergent Research Interchange, HSST, ISSN : 2508-9080, vol. 3, no. 1, pp.1-17, Mar. 2017
12 A. S. Oh, "LED Lighting Monitoring System Using Bluetooth BLE," Journal of the Korea Institute of Information and Communication Engineering, vol. 21, no. 2, pp. 367-372, Feb. 2017.   DOI
13 C. S. Moon, "Topographic Anatomic Difference of The Eyelid According to Age in Korean," M. S. dissertation, Department of Medical Sciences, Ajou University, 2002.