New maintenance method of concrete micro crack using repair stick with self-healing capability and manufacture of repair stick containing the self-healing ingredient (균열자기치유조성물을 함유한 균열보수스틱 제조 및 그를 이용한 새로운 콘크리트 미세균열 보수방법)

  • Ahn, Tae Ho;Kim, Hong Gi;Kim, Kyung Min;So, Kwang Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.111-112
    • /
    • 2014
  • This research focuses on the study that micro-crack of concrete is repaired to use self-healing technology. Self-healing concrete is widely studied in domestic and international construction field recently. Micro-crack(less than 0.3mm)of concrete is repaired using a crack repair stick which containing self-healing agents. Therefore, the crack on construction structure will be easily repaired by using a crack repair stick. Also experiment was proceeded because of evaluating the long term durability.

  • PDF

A Study of the Wall Repair Record and Construction Technology of Geungnakbojeon Hall at Muwisa Temple in Gangjin (강진 무위사 극락보전의 벽체 수리 기록과 시기별 시공기술 고찰)

  • Hong, Eunki
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.2
    • /
    • pp.140-155
    • /
    • 2020
  • The purpose of this study is to examine historical wall repair details through analysis of repair data and administrative documents of the Paradise Conservation of Gangjin Muwisa Temple. In addition, the purpose of the project is to examine the differences and commonalities between the materials and construction technology used in the building's walls. The data for repair work conducted in 1935, 1956, and 1982~3 was analyzed and the results of the research were as follows. First, data for the wall construction conducted in 1935 during the dismantling repair showed that the interior structure of the wall was found to follow that of the original, but the first, second, and final layers used different materials. The composition material of the wall consisted of clay, lime and sand, the second layer used sand and plaster, and the last layer used plaster and seaweed paste. Second, the structure of the wall interior, which was found during the 1956 repairs, consisted of wood woven horizontally and vertically. It was confirmed that this had been installed diagonally using a rope. Third, the 1982~3 repair work confirmed that the wall's interior construction conformed to the original method. The lime-sand wall was formed by mixing slacked lime, sand, soil, fodder, and seaweed grass. Fourth, when the various repairs are considered as a whole, it is clear that the interior structure of the wall was made more than 1900 years ago, and the material used in the wall changed in 1935. Fifth, the materials used for each repair differed, but each project had a common view of cultural heritage repair principles in sections that stated the significance of each project.

An Experimental Study on the Basic Properties of Penetrating repair material using Silicate-based Inorganic Materials (규산염계 무기 재료를 활용한 침투성 보수재의 기초 특성에 관한 실험적 연구)

  • Ha, Sang-Woo;Oh, Sung-Rok;Choi, Yung-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.39-45
    • /
    • 2017
  • In this study, permeable repair materials mainly composed of silicate - based inorganic materials(SIM), which are easily available domestically, were prepared as a basic study for the development of permeable repair materials using SIM. SIM were compared and examined for their performance as repair materials by selecting a product group which has many cases of use in foreign countries. The SIM used were mainly composed of sodium, potassium and lithium silicate. Performance evaluation of SIM was performed by absorption and penetration, compression and adhesion, rapid chloride ion penetration, rapid freezing and thawing, and chemical resistance test. According to the test results, SIM showed effective performance in all areas, mainly because SIM permeates into the interior of the capillary and has a dense internal microstructure. Therefore, it can be used variously to improve the durability of concrete based on the results of this experiment.

Post-fire Repair of Concrete Structural Members: A Review on Fire Conditions and Recovered Performance

  • Qiu, Jin;Jiang, Liming;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.323-334
    • /
    • 2021
  • Concrete structures may rarely collapse in fire incidents but fire induced damage to structural members is inevitable as a result of material degradation and thermal expansion. This requires certain repairing measures to be applied to restore the performance of post-fire members. A brief review on investigation of post-fire damage of concrete material and concrete structural members is presented in this paper, followed by a review of post-fire repair research regarding various types of repairing techniques (FRP, steel plate, and concrete section enlargement) and different type of structural members including columns, beams, and slabs. Particularly, the fire scenarios adopted in these studies leading to damage are categorized as three levels according to the duration of gas-phase temperature above 600℃ (t600). The repair effectiveness in terms of recovered performance of concrete structural members compared to the initial undamaged performance has been summarized and compared regarding the repairing techniques and fire intensity levels. The complied results have shown that recovering the ultimate strength is achievable but the stiffness recovery is difficult. Moreover, the current fire loading scenarios adopted in the post-fire repair research are mostly idealized as constant heating rates or standard fire curves, which may have produced unrealistic fire damage patterns and the associated repairing techniques may be not practical. For future studies, the realistic fire impact and the system-level structural damage investigation are necessary.

Improvement of Biomineralization of Sporosarcina pasteurii as Biocementing Material for Concrete Repair by Atmospheric and Room Temperature Plasma Mutagenesis and Response Surface Methodology

  • Han, Pei-pei;Geng, Wen-ji;Li, Meng-nan;Jia, Shi-ru;Yin, Ji-long;Xue, Run-ze
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.9
    • /
    • pp.1311-1322
    • /
    • 2021
  • Microbially induced calcium carbonate precipitation (MICP) has recently become an intelligent and environmentally friendly method for repairing cracks in concrete. To improve on this ability of microbial materials concrete repair, we applied random mutagenesis and optimization of mineralization conditions to improve the quantity and crystal form of microbially precipitated calcium carbonate. Sporosarcina pasteurii ATCC 11859 was used as the starting strain to obtain the mutant with high urease activity by atmospheric and room temperature plasma (ARTP) mutagenesis. Next, we investigated the optimal biomineralization conditions and precipitation crystal form using Plackett-Burman experimental design and response surface methodology (RSM). Biomineralization with 0.73 mol/l calcium chloride, 45 g/l urea, reaction temperature of 45℃, and reaction time of 22 h, significantly increased the amount of precipitated calcium carbonate, which was deposited in the form of calcite crystals. Finally, the repair of concrete using the optimized biomineralization process was evaluated. A comparison of water absorption and adhesion of concrete specimens before and after repairs showed that concrete cracks and surface defects could be efficiently repaired. This study provides a new method to engineer biocementing material for concrete repair.

The Analysis of Chloride Penetration at Concrete and Repair Material under Tidal and Splash Zone (조간대와 비말대의 콘크리트와 보수재의 염분침투 특성분석)

  • Lee, Joon-Gu;Cho, Young-Kwoun;Kim, Meyong-Won;Kim, Kwan-Ho;Joo, Jae-Hong;Kim, Han-Joung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.207-208
    • /
    • 2010
  • The building that supply tidal and splash zone was constructed near Seamangeum Gate Bridge. The specimens that will be tested for maintenance of gate bridge were exposed on the tidal and splash zone, totally about 650. The characteristics of strength, salt penetration profile, field application of surface repair material and section recover material will be acquired by periodical test. The program was developed to obtain optimal maintenance strategy of gate bridge as a marine concrete structure and to deposit experimental data, lab. test result, field test result, on its D/B. On this paper, the comparison of concrete and recover material in the salt penetration characteristics was expressed. The quantitative analysis of salt contents in concrete surface was most important so the improvement for the machine of gathering power of concrete and the apparatus of measuring chloride contents was proceeded at this time. The two conclusions were summarized like as - The resistance of chloride attack of concrete was appeared 2.5 times bigger than that of recover material - The resistance of chloride attack of polymer series was appeared more higher than that of others.

  • PDF

Structural Analysis and Safety Assessment of KS D 3631 Gas Pipeline Repaired by Carbon Fiber Composite Material Sleeve (탄소섬유복합재료 슬리브로 보수된 KS D 3631 배관의 구조 해석 및 안정성 평가)

  • Choi, Jongmin;Kim, Hansang;Cho, Sungmin;Lee, Seungkuk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.96-103
    • /
    • 2016
  • Proper repair methods of damaged city gas pipeline is important factor to safely transmit gas and to reduce economical loss caused by failure of gas pipelines. Repair methods such as surfacing, type-A and type-B welding and composite sleeve method have been used to repair damaged city gas pipelines. In this paper, among repair methods, composite sleeve repair methods were conducted since they are rather simple processes and their repair quality is not sensitive to workers' ability compared with other repair methods. We discussed composite repair processes especially using carbon fiber prepregs and the experimental results.

Material Properties Depending on the Maximum Aggregate Size and Fineness Modulus for Concrete Repair Materials (콘크리트 단면복구용 보수재료의 굵은 골재 최대치수 및 조립률에 따른 재료적 특성)

  • Sun-Mok Lee;Byung-Je Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.62-69
    • /
    • 2023
  • Re-damage is frequently occurring for various reasons, including material factors, external factors, and factors caused by poor construction in concrete cross-section restoration work, so it is necessary to identify the cause and improve it. Cement-based materials are the most commonly used maintenance materials for concrete structures, and in particular, additional cross-sectional restoration work may be carried out due to re-damage such as cracks and excitement due to dry contraction of the repair material. In this study, a basic study was conducted to identify the characteristics of concrete while diversifying the maximum dimensions and assembly rate of thick aggregates to examine the effects of using thick aggregates in repair materials. As a result, the slump of concrete increased as the maximum size of thick aggregates increased, and the amount of air content was measured 1.88 to 2.35 times higher in the mixing using aggregates with a maximum aggregate size of 5 mm or more compared to the mixing group with a maximum aggregate size of 10 mm or more. It was found that compressive strength was greatly affected by the performance rate of thick aggregates. The compressive strength was measured the highest in the mixture using thick aggregates with the highest performance rate of 20 mm, and the compressive strength of the mixture with the lowest performance rate was more than 45%. As a result of the dry shrinkage measurement, the dry shrinkage was the lowest as the performance rate of the thick aggregate increased according to the change in the maximum dimensions and assembly rate of the thick aggregate, and the lowest performance rate was the largest in the mix. Through this study, it was confirmed that adjusting the particle size by diversifying the maximum dimensions and assembly rate of thick aggregates used in concrete structure repair materials can improve strength and workability and reduce dry shrinkage.

Questions and Solutions on Repair of Lime-Soil Consolidation in Traditional Buildings (전통 건축물 석회다짐층 보수 시공시의 문제점 및 개선 방안)

  • Kim, Jin-Man;Kwak, Eun-Gu;Suh, Man-Cheol;Cho, Heon-Young
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2002.02a
    • /
    • pp.21-31
    • /
    • 2002
  • Lime-soil consolidations are very important as structural material, bonding material, waterproofing material, and finishing material in korea traditional buildings. In this study, we investigated site application trouble in korea traditional buildings being repaired or restored, and propose following solutions. 1) To diminish quality variation occurred by slaking quick-lime in site, it is desirable to use slaked-lime for lime-soil consolidation. 2) For uniform construction of lime-soil consolidation, we would recommend builders to use mixer to be uniform mixture, premixed type materials and compacting machine in field, 3) and to use rigid suitable temporary construction as scaffold for preventing traditional buildings from additional damage occurred in demolition and construction of a layer of lime-soil consolidation of a roofing. 4) For suitable repair of traditional buildings, it is necessary to specify definitely materials and construction methods suggested by the standard specifications for repair of the cultural property.

  • PDF

MATERIAL RELIABILITY OF Ni ALLOY ELECTRODEPOSITION FOR STEAM GENERATOR TUBE REPAIR

  • Kim, Dong-Jin;Kim, Myong-Jin;Kim, Joung-Soo;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.231-236
    • /
    • 2007
  • Due to the occasional occurrences of stress corrosion cracking(SCC) in steam generator tubing(Alloy 600), degraded tubes are removed from service by plugging or are repaired for re-use. Since electrodeposition inside a tube does not entail parent tube deformation, residual stress in the tube can be minimized. In this work, tube restoration via electrodeposition inside a steam generator tubing was performed after developing the following: an anode probe to be installed inside a tube, a degreasing condition to remove dirt and grease, an activation condition for surface oxide elimination, a tightly adhered strike layer forming condition between the electro forming layer and the Alloy 600 tube, and the condition for an electroforming layer. The reliability of the electrodeposited material, with a variation of material properties, was evaluated as a function of the electrodeposit position in the vertical direction of a tube using the developed anode. It has been noted that the variation of the material properties along the electrodeposit length was acceptable in a process margin. To improve the reliability of a material property, the causes of the variation occurrence were presumed, and an attempt to minimize the variation has been made. A Ni alloy electrodeposition process is suggested as a primary water stress corrosion cracking(PWSCC) mitigation method for various components, including steam generator tubes. The Ni alloy electrodeposit formed inside a tube by using the installed assembly shows proper material properties as well as an excellent SCC resistance.