• Title/Summary/Keyword: renewable energy island

Search Result 121, Processing Time 0.027 seconds

Emergy Carrying Capacity of Sungap-do, An Uninhabited Island in Korea (무인도서 선갑도의 에머지 환경수용력 평가)

  • Kang, Dae-Seok
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.60-67
    • /
    • 2010
  • For sustainable use of the resources of uninhabited islands of Korea, their ecological economic potential needs to be fully integrated into their management policy and the carrying capacity of the islands should be evaluated before using or developing them. The emergy methodology was used to evaluate the ecological economic value and carrying capacity of Sungap-do which is an uninhabited island in Incheon, Korea. The system boundary for the emergy evaluation of the island included the sea area within 1km from the high tide level, following the management boundary for the uninhabited islands of Korea stipulated in the Law on the Conservation and Management of Uninhabited Islands. The total renewable emergy input to Sungap-do was $1.04{\times}10^{20}$ sej/yr from tidal energy. The annual ecological economic contribution of the island was evaluated high at 29.9 billion Em₩/yr. If Sungap-do were developed to the national average, its carrying capacity was 6,586 persons at the current living standard of Korea. The carrying capacity of Sungap-do for the long-term sustainability scenario was 2,337 persons at the same living standard as in the developed scenario. When only emergy contribution of the land area was considered, the carrying capacity of Sungap-do sharply decreased to 14 persons for the developed scenario and 5 persons for the long-term sustainability scenario. The carrying capacity of the uninhabited islands of Korea including Sungap-do, thus, needs to be considered from the initial stage of utilization or development projects to sustain the ecosystem benefits and their sustainable uses.

Daily Operating Characteristics of Desalination System with Solar Energy (태양에너지 해수담수화 시스템 일일 운전 특성)

  • Kwak, Hee-Youl;Joo, Hong-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.262-265
    • /
    • 2009
  • This study was carried out to evaluate the clear day operating performances for the decentralized desalination system with the solar thermal system and the photovoltaic power system. In a clear day, we used a solar thermal system as heat source of the single-stage fresh water generator with plate-type heat exchangers and a photovoltaic power system as electric source for hydraulic pumps. The demonstration system generation was designed and installed at Jeju-island in 2006. The system was comprised of the desalination unit with daily fresh water capacity designed as $2m^3$, a $120m^3$ evacuated tubular solar collector to supply the heat, a $6m^3$ heat storage tank, and a 5.2kW photovoltaic power generation to supply the electricity of hydraulic pumps for the heat medium fluids. In a clear day, solar irradiance daily averaged was measured $518W/m^3$, the daily fresh water yield showed that about 565 liter.

  • PDF

The Effect of HVDC#3 on Jeju Power System (제주 HVDC#3 영향 분석)

  • Park, Jung-Soo;Jung, Hong-Ju;Han, Young-Seong;Kim, Rae-Young;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2196-2201
    • /
    • 2011
  • According to the 5th national plan for electric power demand and supply, the 3rd HVDC link will be installed between KEPCO and Jeju Island system and go into operation in June, 2016. However, if it adopt LCC HVDC, Jeju power system could be in voltage instable condition. In order to solve the problem, we propose the application of VSC HVDC to the 3rd HVDC project. In the past, VSC HVDC has many disadvantages such as, inefficiency in conversion, size limit, and expensiveness, compared to LCC HVDC. Recently, the new technologies and the demand for renewable energy interconnection are leading a large growth in VSC HVDC market. In this paper, we will introduce the technical and market trends of VSC HVDC and power system stability analysis results for Jeju power system having LCC and VSC HVDCs.

Design of Substructure for 3MW Offshore Wind Turbine Demonstrator Project (3MW 해상풍력발전기 기초구조물 설계)

  • Byun, Chuljin;Joo, Wandon;Jeong, Seokyong;Park, Jongpo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.185.1-185.1
    • /
    • 2010
  • The 3MW OWEC demonstrator project in Korea will be the first offshore wind project with Korean turbine, Doosan WinDS3000, and constructed on the north-eastern sea of Jeju Island as the water depth of 15m. Integrated loadings of wind and wave are investigated to describe a design loads for both extreme and fatigue conditions using GH-Bladed. A dynamic behaviour of substructure strongly affects a substructure loadings. The jacket structure is designed in accordance with DNV guidelines. The results of this paper show overall design process of offshore substructure as a complex jacket concept and this design process can be implemented on a design of monopile and tripod structures.

  • PDF

The Wind Resource Database KIER-WindJeju (제주도 풍력자원 데이터베이스 KIER-WindJeju)

  • Kim, Hyun-Goo;Lee, Jong-Nam;Jang, Moon-Seok;Kyong, Nam-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.420-422
    • /
    • 2007
  • In order to support wind power development in Jejudo, the island of winds, the wind resource database KIER-WindJeju has been established by meteor-statistical analysis on met-mast measurements of KIER. The analysis includes tower shading, exposure category, wind profile exponent for wind speed extrapolation to hub height of wind turbine, and correlation matrix between neighboring sites to assist choice of appropriate reference site for long-term correlation. KIER-WindJeju will be provided as an add-on of Google $Earth^{TM}$ and will be used as a guideline of future wind resource assessment in Jejudo.

  • PDF

Development of the Small Size Wind Blade Optimized for Korean Wind (한국형 소형 풍력 블레이드 개발에 관한 연구)

  • Lee, Jang-Ho;Chang, Se-Myong;Kim, Sang-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.286-289
    • /
    • 2006
  • To get the better efficiency in Korean type wind characteristics, a new wind turbine blade was developed with some structural, vibrational, and aero-elastic analysis for the design of the full-scale blade. A series of full domestic technology from design to manufacturing was created and used in the middle of the development of nelv wind blade. And it was equipped and measured at the wind test side in the Jeju island. After test, it is verified that the blade has the regular capacity of 10kW at the air velocity of 10m/s. And it shows better capacity in the low air-velocity compared to the imported blade. therefore it can be made by only domestic technology, and used for the domestic wind distribution with the better power generation.

  • PDF

Optimal Power Flow of DC-Grid Based on Improved PSO Algorithm

  • Liu, Xianzheng;Wang, Xingcheng;Wen, Jialiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1586-1592
    • /
    • 2017
  • Voltage sourced converter (VSC) based direct-current (DC) grid has the ability to control power flow flexibly and securely, thus it has become one of the most valid approaches in aspect of large-scale renewable power generation, oceanic island power supply and new urban grid construction. To solve the optimal power flow (OPF) problem in DC grid, an adaptive particle swarm optimization (PSO) algorithm based on fuzzy control theory is proposed in this paper, and the optimal operation considering both power loss and voltage quality is realized. Firstly, the fuzzy membership curve is used to transform two objectives into one, the fitness value of latest step is introduced as input of fuzzy controller to adjust the controlling parameters of PSO dynamically. The proposed strategy was applied in solving the power flow issue in six terminals DC grid model, and corresponding results are presented to verify the effectiveness and feasibility of proposed algorithm.

Regional Distribution of Thermal Conductivity of Ground Heat Exchanger for Geothermal Heat Pump System (지열 냉난방 시스템을 위한 열전도도의 지역별 분포)

  • Lim, Hyo-Jae;Shon, Byong-Hu;Jung, Kye-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.511-514
    • /
    • 2007
  • This study was performed to construct a geothermal data base about thermal conductivity of ground heat exchanger and thermal properties of grouting material which used to refill the borehole. We have acquired geothermal data sets from 39 sites over wide area of South Korea except to Jeju island. From data analysis, the range of thermal conductivity is $1.5{\sim}4.0$ W/mK. It means that thermal conductivity varies with grouting material as well as regional geology and ground water system.

  • PDF

Airfoil design for active load control wind turbine blade (능동하중제어 블레이드 적용을 위한 에어포일 설계)

  • Shin, Hyung-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.449-452
    • /
    • 2009
  • 본 연구에서는 소형 플랩을 채용하여 능동하중제어를 이루고자하는 풍력 블레이드의 적용을 염두해 둔 에어포일 설계를 수행하였다. 블레이드 팁 부분에 플랩을 적용하고자 하는 경우 플랩의 구동장치, 연결 부위 등의 장치 설치를 위한 공간이 블레이드 내부에 필요하다. 이를 위하여 기존의 에어포일의 성능을 유지하면서 뒷전의 두께비가 증가된 에어포일 형상의 설계가 필요하다. 최적설계를 위하여는 MIGA(Multi- Island Genetic Algorithm)을 채용하였으며 에어포일의 성능 계산을 위하여는 Xfoil을 결합하였다. 또한 형상 생성을 위하여 Hick-Henne 형상 함수를 이용하였다. 위와 같은 방법으로 설계된 에어포일은 코드길이 85% 위치에서 두께비 6.3%,양항비 133을 가지게 되어 기본으로 설정한 DU180 에어포일에 비해 성능과 필요 두께비를 모두 능가하는 에어포일이 되었다.

  • PDF

Effect of amplitude modulation in wind turbine noise on noise perception and annoyance (풍력 발전기 소음의 진폭변조가 소음 인지와 불쾌감에 미치는 영향)

  • Lee, Seung-Hoon;Kim, Kyu-Tae;Lee, Soo-Gab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.491-491
    • /
    • 2009
  • Wind turbines produce aerodynamic noise which fluctuate periodically at a blade passing frequency. This sound characteristic is called amplitude modulation, or swishing sound. Several previous studies claimed that this amplitude modulation has a possibility to increase noise annoyance. Thus, this study performed a listening test to find the relationship between the amplitude modulation in wind turbine noise on noise annoyance. The stimuli for the listening test was recorded from a 1.5MW wind turbine in Jeju island. The result of the listening test shows that the amplitude modulation in wind turbine noise significantly increase noise annoyance. Moreover, this study analytically examined the effect of amplitude modulation on noise perception. The result indicates that amplitude modulated sound can be easily perceived even though the background noise level is higher than the sound level of the signal.

  • PDF