• 제목/요약/키워드: removal of iron mechanism

검색결과 34건 처리시간 0.021초

Removal of TCE using zero valent iron (ZVI) with other contaminants

  • 조현희;박재우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.58-61
    • /
    • 2002
  • An alternative to pump and treat groundwater remediation is the use of reactive barriers. Zero valent iron (ZVI) is particularly useful as a reductant of chlorinated hydrocarbons because of its low cost and lack of toxicity ZVI can drive the dechlorination of chlorinated organic compounds and the reduction of chromium from the Cr(Ⅵ) to the Cr(III) state. The contaminants in subsurface environment usually exist as the mixed compounds. Therefore, the objective of this research is to study the effect of the other compounds on TCE removal by ZVI. The removal mechanism of TCE by ZVI is separated the dechlorination and sorption. TCE removal by ZVI slightly increased in presence of naphthalene as the non-reduced compound. TCE removal by ZVI remarkable decreased in presence of carbon tetrachloride, nitrate, and chromate as the reduced compounds. This research suggests that the effect of the coexisted compounds on the removal chlorinated compounds by reactive barrier technology should be considered for practical application.

  • PDF

Removal of Arsenic from Leachate of Tailing using Laboratory-synthesized Zerovalent Iron

  • Kim, Soon-Oh;Jung, Young-Il;Cho, Hyen-Goo;Park, Won-Jeong;Kim, In-Seon
    • Journal of Applied Biological Chemistry
    • /
    • 제50권1호
    • /
    • pp.6-12
    • /
    • 2007
  • Feasibility of laboratory-synthesized zerovalent iron was investigated to remove arsenic from leachates of tailings taken from an Au-Ag abandoned mine. The tailings were seriously contaminated with arsenic, and its potential adverse effect on the ecosystems around the mine seems to be significantly high. Long-term column experiments were conducted for about 3.5 months to evaluate the effectiveness of the synthesized zerovalent iron for removal of arsenic. Over than 95% removal efficiency of As was observed in the zerovalent iron mediated tests. In addition, the XRD data suggest that the corrosion products of ZVI were identified magnetite, maghemite, goethite, and lepidocrocite, all of which support Fe(II) oxidation as an intermediate step in the zerovalent iron corrosion process. The results indicate that arsenic can be removed from the tailing-leachate by the mechanism of coprecipitation and/or adsorption onto those iron oxides formed from ZVI corrosion.

Iron Mixed Ceramic Pellet for Arsenic Removal from Groundwater

  • Shafiquzzam, Md.;Hasan, Md. Mahmudul;Nakajima, Jun
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.163-168
    • /
    • 2013
  • In this study, an innovative media, iron mixed ceramic pellet (IMCP) has been developed for arsenic (As) removal from groundwater. A porous, solid-phase IMCP (2-3 mm) was manufactured by combining clay soil, rice bran, and Fe(0) powder at $600^{\circ}C$. Both the As(III) and As(V) adsorption characteristics of IMCP were studied in several batch experiments. Structural analysis of the IMCP was conducted using X-ray absorption fine structure (XAFS) analysis to understand the mechanism of As removal. The adsorption of As was found to be dependent on pH, and exhibited strong adsorption of both As(III) and As(V) at pH 5-7. The adsorption process was described to follow a pseudo-second-order reaction, and the adsorption rate of As(V) was greater than that of As(III). The adsorption data were fit well with both Freundlich and Langmuir isotherm models. The maximum adsorption capacities of As(III) and As(V) from the Langmuir isotherm were found to be 4.0 and 4.5 mg/g, respectively. Phosphorus in the water had an adverse effect on both As(III) and As(V) adsorption. Scanning electron microscopy results revealed that iron(III) oxides/hydroxides are aggregated on the surface of IMCP. XAFS analysis showed a partial oxidation of As(III) and adsorption of As(V) onto the iron oxide in the IMCP.

Development of hybrid resin to reduce silica in borated water

  • Ramzan Akhtar ;Shahid Latif ;Syed Aizaz Ali Shah ;Shaukat Saeed ;Abdul Aziz
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2547-2555
    • /
    • 2023
  • Amberlite IRN-78 resin was incorporated with iron to make a hybrid resin for the removal of silica from the borated water of nuclear power plants. The hybrid resin contained 0.84 wt % iron compounds upon pyrolysis. In batch experiments carried out at room temperature, 1 g of the hybrid resin removed ~60 ㎍ silica from 1 ppm borated water in ~120 min. The efficiency of the hybrid material increased with the resin quantity, decreased with silica concentration, and remained unchanged at different pH values. Freundlich and Temkin isothermal adsorption dominated the silica removal process and followed the pseudo-first-order and intra-particle diffusion mechanism simultaneously. The concentration of the leached iron remained appreciably under the safe limits of 200 ㎍/l during the experiments. This detailed study suggests the use of hybrid resin for the removal of silica from borated water streams and other similar systems.

Adaptive method for the purification of zinc and arsenic ions contaminated groundwater using in-situ permeable reactive barrier mixture

  • Njaramba, Lewis Kamande;Nzioka, Antony Mutua;Kim, Young-Ju
    • International Journal of Advanced Culture Technology
    • /
    • 제8권2호
    • /
    • pp.283-288
    • /
    • 2020
  • This study investigated the purification process of groundwater contaminated with zinc and arsenic using a permeable reactive barrier with a zero-valent iron/pumice mixture. We determined the removal rates of the contaminants for 30 days. In this study, column reactor filled with the zero-valent iron/pumice reactive mixture was used. Experimental results showed that the mixture exhibited an almost complete removal of the zinc and arsenic ions. Arsenic was removed via co-precipitation and adsorption processes while zinc ions were asorbed in active sites.The purification process of water from the metal ionscontinued for 30 days with constant hydraulic conductivity because of the enhanced porosity of the pumice and interparticle distance between the zero-valent iron and pumice. Contaminants removal rates and the remediation mechanism for each reactive system are described in this paper.

Recovery of Ammonium Salt from Nitrate-Containing Water by Iron Nanoparticles and Membrane Contactor

  • Hwang, Yu-Hoon;Kim, Do-Gun;Ahn, Yong-Tae;Moon, Chung-Man;Shin, Hang-Sik
    • Environmental Engineering Research
    • /
    • 제17권2호
    • /
    • pp.111-116
    • /
    • 2012
  • This study investigates the complete removal of nitrate and the recovery of valuable ammonium salt by the combination of nanoscale zero-valent iron (NZVI) and a membrane contactor system. The NZVI used for the experiments was prepared by chemical reduction without a stabilizing agent. The main end-product of nitrate reduction by NZVI was ammonia, and the solution pH was stably maintained around 10.5. Effective removal of ammonia was possible with the polytetrafluoroethylene membrane contactor system in all tested conditions. Among the various operation parameters including influent pH, concentration, temperature, and contact time, contact time and solution pH showed significant effects on the ammonia removal mechanism. Also, the osmotic distillation phenomena that deteriorate the mass transfer efficiency could be minimized by pre-heating the influent wastewater. The ammonia removal rate could be maximized by optimizing operation conditions and changing the membrane configuration. The combination of NZVI and the membrane contactor system could be a solution for nitrate removal and the recovery of valuable products.

강변여과수 처리를 위한 포기-모래여과공정에서 망간제거 기작에 관한 연구 (The study of manganese removal mechanism in aeration-sand filtration process for treating bank filtered water)

  • 최승철;김세환;양해진;임재림;왕창근;정관수
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.341-349
    • /
    • 2010
  • It is well known that manganese is hard to oxidize under neutral pH condition in the atmosphere while iron can be easily oxidized to insoluble iron oxide. The purpose of this study is to identify removal mechanism of manganese in the D water treatment plant where is treating bank filtered water in aeration and rapid sand filtration. Average concentration of iron and manganese in bank filtered water were 5.9 mg/L and 3.6 mg/L in 2008, respectively. However, their concentration in rapid sand filtrate were only 0.11 mg/L and 0.03 mg/L, respectively. Most of the sand was coated with black colored manganese oxide except surface layer. According to EDX analysis of sand which was collected in different depth of sand filter, the content of i ron in the upper part sand was relatively higher than that in the lower part. while manganese content increased with a depth. The presence of iron and manganese oxidizing bacteria have been identified in sand of rapid sand filtration. It is supposed that these bacteria contributed some to remove iron and manganese in rapid sand filter. In conclusion, manganese has been simultaneously removed by physicochemical reaction and biological reaction. However, it is considered that the former reaction is dominant than the latter. That is, Mn(II) ion is rapidly adsorbed on ${\gamma}$-FeOOH which is intermediate iron oxidant and then adsorbed Mn(II) ion is oxidized to insoluble manganese oxide. In addition, manganese oxidation is accelerated by autocatalytic reaction of manganese oxide. The iron and manganese oxides deposited on the surface of the sand and then are aged with coating sand surface.

Modeling As(III) and As(V) adsorption and transport from water by a sand coated with iron-oxide colloids

  • Ko, Il-Won;Lee, Cheol-Hyo;Kim, Kyoung-Woong
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.243-247
    • /
    • 2004
  • Tile development of a porous iron-oxide coated sand filter system can be modelled with the analytical solution of tile transport equation in order to obtain the operating parameters and investigate the mechanism of arsenic removal. The adsorbed amount from the model simulation showed the limitation of adsorption removal during arsenic transport. A loss reaction term in the transport equation plays a role in the mass loss in column conditions, and then resulted into the better model fitting, particularly, for arsenate. Further, the competitive oxyanions delayed the breakthrough near MCL (10 $\mu$g/L) due to the competitive adsorption. This is the reason why arsenate can be strongly attracted in tile interface of an iron-oxide coated sand, and competing oxyanions can occupy the adsorption sites. Therefore, arsenic retention was regulated by non-equilibrium of arsenic adsorption in a porous iron-oxide coated sand media. The transport-limited process seemed to be affect the arsenic adsorption by coated sand.

  • PDF

Degraded Paddy Soils. I. Theoretical Analysis on the Sultide Formation and the Effect of Iron Hydroxide Upon Removal of Sulfide from Solution

  • Cho, Chai-Moo
    • Applied Biological Chemistry
    • /
    • 제2권
    • /
    • pp.9-14
    • /
    • 1961
  • The formation of sulfide from sulfate has been discussed from the thermodynamic principles. No mechanism of the reaction has been presented. From the stoichiometric and Nernst equations for the conversion of sulfate into sulfide, it was concluded that the formation of sulfide from sulfate can take place more readily if pH of a medium is low. The difficulty of this conversion increases with increasing pH. As pH of a medium increases, the degree of dissociation of H₂S into S= increases and this, in turn, renders the chance of precipitation of sulfide as FeS easier. Higher the pH of a soil or medium, greater is the S= concentration. The concentration of ferrous ion required to remove dissolved sulfide in a medium by forming insoluble FeS decreases with increasing pH. From the theory it was pointed out that an application of lime and iron rich foreign substances to a soil may be effective in causing the removal of dissolved sulfide from solution.

  • PDF

Enhanced Removal of Phenol from Aquatic Solution in a Schorl-catalyzed Fenton-like System by Acid-modified Schorl

  • Xu, Huan-Yan;Prasad, Murari;Wang, Peng
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권4호
    • /
    • pp.803-807
    • /
    • 2010
  • Schorl modified by $H_2SO_4$ has been successfully developed to enhance schorl-catalyzed Fenton-like reaction for removal of phenol in an aqueous solution. The phenol removal percentage can be increased from 4% to 100% by the system of modified schorl and $H_2O_2$. Batch experiments indicate that the percent increases in removal of phenol by increasing the dosage of catalyst, temperature and initial concentration of $H_2O_2$. The results of XRD, FT-IR and SEM suggest that no new phases are formed after removal of phenol by modified schorl. ICP-AES results reveal that more dissolution of iron results in higher catalytic oxidant activity in the system of modified schorl and $H_2O_2$. Besides minor adsorption, mineral-catalyzed Fenton-like reaction governs the process.